DE300i-SW User's Guide - Rev. A01StorCase Technology, Inc.
ii
LIMITED WARRANTY
STORCASE TECHNOLOGY, Incorporated (StorCase) warrants that its products will be free
from defects in material and workmanship, subject to the conditions and limitations set forth
below. StorCase will, at its option, either repair or replace any part of its product that proves
defective by reason of improper workmanship or materials. Repair parts or replacement
products will be provided by StorCase on an exchange basis, and will be either new or
reconditioned to be functionally equivalent to new.
This warranty does not cover any product damage that results from accident, abuse, misuse,
natural or personal disaster, external power surge or failure, or any unauthorized disassembly, repair or modification. StorCase will not be responsible for any software, firmware or other
customer data stored within, or interfacing with a StorCase product.
Duration of Warranty
Seven-Year Warranty: The following StorCase products are covered by this warranty for
a period of seven (7) years from the original date of purchase from StorCase or its authorized
reseller: all Data Express® removable device enclosures and all StorCase interface cables and
accessories specifically intended for use with these products. Data Silo®, Data Stacker® and
InfoStation® products are covered by this warranty for a period of seven (7) years, excepting
the RAID controller, power supply, fan and blower components, which are covered by the
three-year warranty described below.
Three-Year Warranty: The following StorCase products are covered by this warranty for
a period of three (3) years from the original date of purchase from StorCase or its authorized
reseller: all Rhino®JR external expansion chassis and all RAID controller modules. In addition,
the following components of the Data Silo®, Data Stacker®, InfoStation® products are subject
to warranty for a period of three (3) years: all power supplies, fans and blowers.
Warranty Claim Requirements
To obtain warranty service, the defective product must be returned to your local authorized
StorCase dealer or distributor, or, with prior StorCase approval, to the StorCase factory
service center.
For defective products returned directly to StorCase, a Return Material Authorization (RMA)
number must be obtained by calling StorCase Customer Service at (714) 445-3455. The RMA
number must be prominently displayed on the outside of the return package. Shipments must
be freight-prepaid and insured, and must include the product serial number, a detailed
description of the problem experienced, and proof of the original retail purchase date. Products
must be properly packaged to prevent damage in transit. Damage resulting from improper
packaging will not be covered by this warranty. The StorCase factory service center is located
at 17650 Newhope Street, Receiving Dock, Gate #4, Fountain Valley, CA 92780, U.S.A.
StorCase provides free technical support. If you experience any difficulty during the
installation or subsequent use of a StorCase product, please contact StorCases Technical
Support Department prior to servicing your system. This warranty covers only repair or
replacement of defective StorCase products, as described above. StorCase is not liable for,
and does not cover under warranty, any costs associated with servicing and/or installation
of StorCase products.
StorCase Technical Support can be reached in the U.S. at (714) 438-1858 or toll-free at (888)
435-5460 (U.S. and Canada only). StorCase European Technical Support can be reached in
the U.K. at +44 (0) 1932 738900.
Disclaimers
The foregoing is the complete warranty for the products identified above and
supersedes all other warranties and representations, whether oral or written.
StorCase expressly disclaims all warranties for the identified products, which are
not stated herein, including, to the extent permitted by applicable law, any implied
warranty of merchantability or fitness for a particular purpose. In no event will
StorCase be liable to the purchaser, or to any user of a StorCase product, for any
damages, expenses, lost revenues, lost savings, lost profits, or any other
incidental or consequential damages arising from the purchase, use or inability
to use a StorCase product, even if StorCase has been advised of the possibility
efforts have been made to ensure the accuracy of this document, StorCase
Technology, Inc. assumes no liability resulting from errors or omissions in this
publication, or from the use of the information contained herein.
Please check the StorCase web site at http://www.storcase.com or contact your
StorCase representative for the latest revision of this document.
Introduction1
INTRODUCTION
PackagingInformation
The StorCase Technology Data Express® system is shipped in a container designed to provide
protection and prevent damage during shipment. The Data Express unit was carefully
inspected before and during the packing procedure at the factory. Bent or broken connectors,
or evidence of other damage to the Data Express should be reported to the shipper immediately.
Refer to Figure 1 for the package contents.
If the wrong Data Express model has been received, please call your reseller or StorCase at
(800) 435-0642 to arrange for a Return Material Authorization (RMA). StorCase cannot accept returns which do not display an RMA number on the outside of the package. Return the
unit with all the original packing materials.
Before removing any component from its packaging, discharge any static electricity by
touching a properly grounded metal object.
Serial Numbers
Both the Data Express receiving frame and carrier are labeled with serial numbers. These
numbers must be reported to the StorCase Customer Service Representative in order to
receive a Return Material Authorization (RMA) for warranty claims. Locate the serial number
labels and record the numbers in the spaces provided below.
Receiving Frame:
Drive Carriers:
DE300i-SW User's Guide - Rev. A01StorCase Technology, Inc.
2Introduction
PackageContents
The DE300i-SW package contents include the following items. If any item is missing or
damaged, contact your StorCase dealer for a replacement.
The StorCase Technology Data Express® DE300i-SW is a durable removable enclosure for
three low-profile (1" high), 3.5" form factor SCSI drives. The DE300i-SW is composed of a
receiving frame with 68-pin SCSI Wide I/O connectors which contains three (3) removable
drive carriers and fits within 5.25" full-height peripheral slots.
The DE300i-SW allows a drive to be removed and transported to another DE300i-SW-equipped
computer or expansion chassis, and also provides the ability to secure sensitive data by
removing and storing the drive safely for future use.
This User's Guide describes the steps required to install the StorCase Data Express
DE300i-SW removable enclosure inside a computer peripheral bay or external expansion
chassis. This guide supplements documentation provided with the host computer system,
operating system, and the drive to be installed within the Data Express carrier.
0510
Receiving
Frame
Drive
Carrier
Figure 2: DE300i-SW Receiving Frame and Carrier
DE300i-SW User's Guide - Rev. A01StorCase Technology, Inc.
4Introduction
ReceivingFrameFrontPanel
(Figure 3)
Key Lock/Drive Power Switch (Figure 3) - This key switch assures proper
seating of the drive carrier within the receiving frame, turns power to the drive carrier
on and off, and prevents unauthorized removal or installation of the carrier.For the
computer to access data on the DE300i-SW drive, the key must be turned
counterclockwise to the locked position. The key can be configured as either fixed
or removable as shown in Appendix C.
Unit ID Number Indicator (Figures 3 & 4) - This LED displays the physical address
of the DE300i-SW device carrier if the carrier is installed and locked in the receiving
frame or if the carrier is removed from the receiving frame. If the carrier is installedbut not locked in the receiving frame, a "u" will be displayed to indicate an unlocked
condition. The unit number is selected by means of the unit ID select switch inside
the receiving frame using a special alignment tool supplied with the DE300i-SW (see
Figure 10).
The Activity Indicator (Figures 3 & 4) - A small dot next to the unit ID number
illuminates to indicate when the host computer is accessing the data on the
DE300i-SW carrier. This dot will flash during communication with the host computer.
Device Spin Down/Up Timer (Figure 3) - This timer controls the length of time that
the unit number display flashes during device spin down/up, providing a visual
indication of drive activity. Refer to Figure 11 for switch settings.
Figure 4: Receiving Frame Unit ID Number and Activity Display
ReceivingFrameRearPanel
(Figure 5)
I/O Connectors (J3, J4, & J5) - These connectors provide a standard interface for all
SCSI signals (Figure 5). See Table 2 for pin assignments.
DC Power Connector (J6) - A standard 4-pin DC power connector is used to accept
DC power.
ID Select Connectors (J3A, J3B & J3C) - Pins 1-8 of these connectors provide unit
SCSI ID selection for the computer system or expansion chassis. For remote ID selection
through an expansion chassis, an appropriate cable must be attached to these pins and
the unit ID must be set to "0". The unit ID can be set with a rotating switch located inside
the receiving frame (Figure 10).
Disable Termination (DT) - A factory installed jumper on these pins disables
termination. Removing this jumper will enable termination. Remove this jumper if the drive
is physically located at the end of a SCSI daisy chain.
Remote Activity LED (RLED) - These pins provide power for a remote LED device
While performing the steps in this section, work on a soft surface to prevent excessive shock
to the drive being installed. Also refer to the manufacturer's documentation provided with the
drive.
NOTE: A #2 Phillips screwdriver will be required during this procedure.
1.Remove the drive from its protective packaging.
2.Plastic Drive Bezel: If the drive to install is equipped with a plastic front bezel,
remove it.
3.SCSI Drive Termination: Disable or remove the termination resistor packs
from the drive. Termination is performed by an external terminator in the
DE300i-SW receiving frame (Figure 5). Refer to the documentation provided by
the drive manufacturer for the location of these terminators or jumpers.
4.SCSI Drive ID Select Jumpers: Locate the SCSI ID select jumper positions on
the drive, and remove any jumper plugs in this area. The SCSI ID cable will be
installed into this section of each drive (Figure 6).
5.SCSI ID Cable: Each DE300i-SW carrier is supplied with one (1) 5-wire cable.
This cable carries the SCSI ID signal between the drive and the carrier. The signal
is then transferred to/from the receiving frame via the carrier and receiving frame
mating connectors. The ID cable permits easy unit ID selection via a small switch
located on the inside of the receiving frame (Figure 10). The cable is designed
to connect to drives with 2mm ID select connectors. Attach five (5) connectors
from the carrier SCSI unit ID cable to the appropriate drive pins (Figure 7).
The unit ID cable contains black, brown, red, orange, and yellow wires. The
black wire plugs into the drive pin used to select ID0, the brown wire plugs into
the drive pin for ID1, the red wire plugs into the drive pin for ID2, and the orange
wire connects to ID3. Most drive manufacturers label these pins as ID0, ID1, ID2
and ID3, or similar identification. The yellow wire plugs into the drive activity
LED pin.
Drives use a row of pins to provide ground to the ID signals. This row of pins
is not used for the DE300i-SW installation. One end of the unit ID cable connects
to the signal row of ID pins on the drive. The other end of this cable attaches
to the ID select connector on the inside of the carrier (Figures 6 & 7). Refer to
the drive manufacturer's documentation for more information.
DE300i-SW User's Guide - Rev. A01StorCase Technology, Inc.
8Installation
Installation
1.Attach the I/O cable from the DE300i-SW carrier board to the drive (Figure 6).
2.Attach the 4-pin power cable from the carrier board to the drive (Figure 6).
3.Install the 5-pin ID select cable into the carrier board connector (Figure 7).
4.Carefully insert the drive into the carrier at an angle, cable-end first. Make surethat none of the cables are pinched. Lower the front of the drive carefully
into place. Fasten the drive into the carrier with four (4) #6-32 Phillips Flat Hd.
screws provided.
5.Attach the provided drive cover with two #6-32 Phillips Flat Hd. screws.
Figure 7 illustrates a typical SCSI ID select connection to a drive with 2mm ID select pins. In
most cases, the drive manufacturer labels each pair of SCSI ID select pins in their significant
bit order (0, 1, 2, 3 as shown in Figure 7). In other cases, the manufacturer does not label
these pins in their significant bit order, but instead, assigns pin numbers only. In any case,
all odd numbered pins or all even numbered pins will be the signal row. The wires on the wire
harness connect to the positive pin (or signal pins) on the drive. Refer to the device
manufacturer's documentation for additional pin numbering and jumper option information.
Attach the ID select cable to the drive using the 2mm connectors. Align the ID0 pin with the
black wire. Attach the other end of the ID select cable to the ID select connector located on
the carrier board, inside the carrier. Refer to the manufacturers documentation to disable
termination on the drive.
Figure 7: Typical SCSI ID Select Connections (2mm Drive Pins)
DE300i-SW User's Guide - Rev. A01StorCase Technology, Inc.
10Installation
InstallingtheReceivingFrame
The drive should be installed into the carrier before installing the receiving frame into the
mounting bay of a computer or expansion chassis.
NOTE:Use a #2 Phillips screwdriver during this procedure.
1.Turn OFF power to the computer.
2.Open the computer system according to the manufacturers instructions. If
necessary, temporarily remove any expansion boards that may make installation
difficult.
3.To select the DE300i-SW unit ID remotely through the computer system or external
expansion chassis, the appropriate cable from the system must be connected to
option pins (1-8 on connectors J3A, J3B, J3C) on the rear of the receiving frame
(Figure 8). Set the unit ID to "0" for remote ID selection (Figure 10).
Table 1: J3A, J3B, J3C Option Pin Signal Descriptions
PINSignalFunction
1ID0SCSI ID
2GNDGround
3ID1SCSI ID
4GNDGround
5ID2SCSI ID
6GNDGround
7ID3SCSI ID
8GNDGround
9DTDisable On Board Terminator
10GNDGround
11RLEDCRemote LED Cathode
12RLEDARemote LED Anode
13DFAULTForce Drive Fault Signal to Display
14GNDGround
15SYNCDrive Synchronization Signal
16GNDGround
17TPWRTerminate Power To/From SCSI Bus
18GNDGround
19WTPReserved
20GNDGround
21LKADisable Isolator Functions
22LKBDisable Isolator Functions
4. With the drive carriers locked into place inside the receiving frame, install the
DE300i-SW receiving frame into the drive opening in the computer or expansion chassis.
Use the appropriate guides to position the DE300i-SW, and fasten it into place with eight
(8) #6-32 Phillips screws provided. Figure 9 illustrates the location of the mounting
holes. Mounting holes are provided on each side and the bottom of the receiving frame
to accommodate a variety of mounting configurations. Use the mounting holes which
best suit the computer or expansion chassis configuration.
DE300i-SW User's Guide - Rev. A01StorCase Technology, Inc.
12Installation
Front of Unit
Mounting
Holes
(Right)
Mounting
Holes
(Bottom)
0520
Figure 9: Receiving Frame Mounting Holes
5. Adjust the front of the receiving frame so the carrier slides freely in and out on the
receiving frame guides. The position of adjoining peripheral units may require
adjustment.
6. To connect a drive to a remote activity LED in the computer system or expansion chassis,
connect the appropriate cable(s) to the receiving frame motherboard connectors J3A,
J3B, and J3C Pins 11 & 12 as shown in Figure 5.
7. Connect the I/O cable from the host adapter to the receiving frame. The Pin 1 indicator
on the cable must be properly aligned. Refer to Figure 5 for the correct Pin 1 location.
8. When installing the DE300i-SW into a computer system, make sure that only the last SCSI
device is terminated. If the DE300i-SW is at the end of a daisy chain, the receiving frame
termination for the last device mustbe enabled by removing the appropriatejumper. If the DE300i-SW is in the middle of a daisy chain, termination should be
disabled (factory installed jumper) at J3A, J3B, and J3C, Pins 9 & 10 (Figure 8).
In most cases, if installing the DE300i-SW into an external expansion chassis, the
factory-installed jumpers at J3A, J3B and J3C, Pins 9 & 10 (disable termination) should
be left in place. Termination will be handled by an external terminator on the expansion
chassis.
9. Connect the power cable from the DC power supply in the computer or expansion
chassis to the power connector on the DE300i-SW receiving frame. Refer to Figure
5 for the receiving frame power connector location.
10.Replace any expansion boards that may have been removed earlier. Replace the
system cover according to the manufacturers instructions.
11.Reconnect any system or peripheral cables removed earlier.
12.If the DE300i-SW has been installed into an external expansion chassis, connect the
SCSI and power cables to the chassis. If the expansion chassis is at the end of a
daisy chain, make certain that it is properly terminated. Refer to the computer system
and expansion chassis manuals for information on how to do this. Turn on the
expansion chassis power before turning on the computer system power.
13.Turn ON power to the computer. If the installation has been successful, and all cables
have been properly attached, the system should boot normally. Although the
computer may not recognize the DE300i-SW yet, the appropriate front panel LED
indicators on the Data Express should illuminate. If the system does not boot properly,
there could be a SCSI ID conflict. Refer to the following section "Selecting the UnitID Number".
NOTE: The lock on the DE300i-SW receiving frame functions as a lock and a DC
power switch for the carrier unit. The lock must be engaged (turned
counterclockwise) in order to supply power to the carrier and installed drive
unit.
14.The new drives may need to be formatted or initialized prior to use with the operating
system and applications software. Additionally, an appropriate driver may need to
installed for the host controller to recognize the newly installed device. Refer to the
drive and/or computer manufacturer's documentation for formatting information.
Refer to the host controller instructions for driver information.
SelectingtheUnitID Number
Each SCSI device on the computer system requires a separate SCSI ID number.
16-bit SCSI interface protocol permits 16 (0-15) unique SCSI ID numbers. Usually, ID7 is
reserved for the host controller. If the computer system has any internal or external SCSI
devices, some ID numbers may already be reserved. For instance, if the computer system
is already equipped with an internal SCSI hard drive, the drive may be designated as SCSI
device "0". Refer to the computer system documentation for additional information.
1. Verify that power is turned on to the DE300i-SW receiving frame by turning on the
computer or external expansion chassis. A number should appear in the unit ID display
window if the carrier is locked into place.
2. Unlock the DE300i-SW carrier from the receiving frame. The unit ID number will begin
flashing, indicating that the drive is spinning down. DO NOT REMOVE THE CARRIER
FROM THE RECEIVING FRAME WHILE THE UNIT ID NUMBER IS FLASHING. The length
of time that the unit ID number flashes is controlled by a small timing switch located on
the side of the receiving frame. Refer to Appendix B for information on adjusting the
timer (Figure B-3).
DE300i-SW User's Guide - Rev. A01StorCase Technology, Inc.
14Installation
WARNING: Unlocking the carrier unit switches DC power off to the drive. Since drives
require a short amount of time to spin down, allow at least 15 seconds before pulling
the carrier unit out of the receiving frame to avoid possible damage to the drive.
3. A "u" will be displayed once the drive has completed spin down and is ready to be
removed from the receiving frame. The indicator will return to the SCSI ID number when
the carrier is removed from the receiving frame.
4. Use the alignment tool supplied with the DE300i-SW to select the ID number of the disk
drive. Refer to Figure 10 for the location of the unit ID select switch inside the receiving
frame.
WARNING: Selecting an invalid ID number, or selecting the same unit ID number on different
5. After selecting an appropriate unit ID number, replace the DE300i-SW carrier in the
receiving frame, and LOCK IT IN PLACE.
6. If the DE300i-SW has been installed into an external expansion chassis, verify that
power is on to the chassis and that the last device in the SCSI daisy chain is properly
terminated.
7. Reboot the computer system.
devices may cause unpredictable results and the computer system may not
recognize the installed device(s). If the computer system can not recognize
the boot disk, the computer system may fail to start-up properly.
NOTE: The hyphen preceding a signal name indicates that the signal is active low.
Pin Assignments
DE300i-SW User's Guide - Rev. A01StorCase Technology, Inc.
16Installation
Adjusting the Spin Down/Up Timer
NOTE:The timer for device spin down is controlled by a small selector, located in a cutout
on the side of the DE300 receiving frame as shown in Figure 11. The amount of
time required for a drive to spin down is approximately 15 seconds or more. This
number can vary depending on the type of SCSI device and manufacturer (some
drives may require 45 seconds or more). The factory configuration is set for 20
seconds. A different delay time may be selected with the provided alignment tool.
Refer to the SCSI device manufacturers manual for more information on required
device spin down time.
DE300i-SW User's Guide - Rev. A01StorCase Technology, Inc.
20Appendix B - Factory-Installed Options
Appendix B - Factory-Installed Options
Hot Swap Board
The DE300i-SW/H SCSI Hot Swap Board allows the installation, removal or exchange of
DE300i-SW carriers while your computer system is operating by monitoring and protecting the
computer system and other peripheral devices on the SCSI Bus. The Hot Swap option
eliminates the need to shut down your system when adding or removing a SCSI device by
performing two functions:
1. Delays power up/down of the drive until the time period between SCSI bus cycles. This
prevents the interruption of any SCSI bus activity being done by other devices on the
bus.
2. Prevents drive power sequencing from generating noise on the SCSI bus, thus
preventing data transfer corruption on other devices.
Please note that, whereas UNIX and Apple-based systems provide mount/dismount drive
commands, most PC systems do not provide such a feature. When using one of these operating
systems, it may be necessary to reboot the computer after adding or changing a drive. This
reboot activity will force the SCSI host adapter to rescan its SCSI bus for physically attached
drives, and will then be able to access the new or changed drive.
Attaching the Hot Swap Board
If the Hot Swap Board is not already attached to the DE300 receiving frame, follow the steps
below for installation instructions. Otherwise, proceed to the "Using the Hot Swap Board"
section for usage instructions.
IMPORTANT NOTE: The device carriers should be locked into the receiving frame prior to the
following procedure to maintain proper connector alignment between the
Appendix B - Factory-Installed Options21
Figure B-1: Attaching the Hot Swap Board
Jumper Options
Most jumper options are configurable via the receiving frame motherboard (Figures 5 & 8).
The Hot Swap Board provides three configurable jumpers, DTA, DTB, and DTC (Figure B-2).
When installed (factory default), these jumpers disable onboard termination at drives A, B, and
C, respectively. If a DE300 drive will be physically located at the end of a SCSI daisy chain,
remove the appropriate jumper to enable termination.
Using the Hot Swap Board
Carrier Removal
Follow the procedures below to remove the Data Express carrier from the receiving frame
equipped with the Hot Swap option.
1. Verify that the drive is not active. If the system is on a network, make certain other users
are not accessing the target drive, then disable it from the network. Dismount the drive.
2. Turn the DE300 key lock mechanism (located on the front of the receiving frame),
clockwise to the OFF position. This unlocks the drive from the receiving frame and
activates the Hot Swap Board. The unit ID number on the display will begin flashing.
WARNING:Be careful not to remove or disturb the carrier unit at this point. Although
DE300i-SW User's Guide - Rev. A01StorCase Technology, Inc.
the carrier is physically unlocked, the drive requires a minimum of 15
seconds to spin down and is subject to vibration and possible damage
during this period.
22Appendix B - Factory-Installed Options
I/O Connector
Pin 1
Hot Swap
Board
(Installed)
Carriers
(Installed)
DRIVE A
DRIVE B
DRIVE C
Receiving Frame
Motherboard
JP1
DTA
JP2
DTB
JP3
DTC
Figure B-2: Hot Swap Board Termination Jumpers
Disable On Board
Termination Jumpers
(Installed at Factory)
0518
3. As the unit ID number flashes, the Hot Swap Board monitors the activity of the SCSI
bus. When activity is no longer present, the Hot Swap Board will remove power from
the drive and then remove the device from the SCSI Bus. The unit number will continue
to flash during this period.
4. After a short length of time the unit ID display will turn from a flashing unit ID number
to a steady u, indicating that the device is powered down, unlocked and ready to be
removed from the receiving frame.
Follow the procedures below to install the DE300i-SW Carrier into the receiving frame equipped
with the Hot Swap option.
1. Install the Carrier into the Receiving Frame. A "u" will be present on the front panel.
2. Turn the key lock mechanism, located on the front of the receiving frame, counter
clockwise to the ON position. This locks the drive into the receiving frame and activates
the Hot Swap Board. The drive will begin to spin up and the unit number on the display
will begin flashing.
3. After a short length of time the unit display will stop flashing, indicating that the device
is ready to be used.
DE300i-SW User's Guide - Rev. A01StorCase Technology, Inc.
24Appendix C - Attaching the ON/OFF Key
Appendix C - Attaching the ON/OFF Key
The following information will provide the necessary steps to attach the ON/OFF key to the
key lock mechanism so that it is non-removable, preventing accidental key loss. The procedure
can be reversed at a later date to revert back to a removable key.
1. Make certain power is OFF to the receiving frame.
Locate the rectangular shaped key lock mechanism access hole on the inside of the receiving
frame. Note that the pawl is in an upright position.
Insert the key into the key lock.
2. Rotate the key 90 degrees counterclockwise so
that the pawl is visible in the access hole as
shown in the figure at left.
3. Using the provided alignment tool, unscrew and
remove the pawl from the access hole.
4. Rotate the key 180 degrees clockwise.
5. Reinstall the pawl into the access hole with the
alignment tool.
Your key is now attached to the key lock mechanism.
The optional molded plastic carrying case is designed to transport the DE300i-SW carrier from
one location to another in a safe, impact and moisture resistant environment. Its compact
dimensions, 7 long x 9 wide x 3.5 high, make it easy to carry and to store. The foam lining
is contoured to fit a single Data Express carrier with a 1-inch form factor. Contact StorCase
for further details and ordering information.
DE300i-SW User's Guide - Rev. A01StorCase Technology, Inc.
Please take a few moments when your computer system is up and running to send us your
ideas and suggestions for improving our products and documentation. Did the installation go
smoothly for you? Are there any changes you would like us to make, either with the hardware
itself, or with the installation instructions? Everyone at StorCase Technology is working
toward the goal of providing you with the highest quality, most cost effective, products
available on the market, and we need your comments to guide our efforts. We look forward
to hearing from you soon!
Date:
Your Name:
Address:
Telephone: ()
To mail this page, carefully remove it from the manual, fold it, staple or tape it shut, and drop
it in the mail. To FAX this page, carefully remove it from the manual (or make a photocopy) and
FAX it to us at (714) 438-1847. Thank you for taking the time to help us make our products
better.
DE300i-SW User's Guide - Rev. A01StorCase Technology, Inc.
28Reader's Comments
FOLD ALONG THIS LINE AND STAPLE SHUT
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
CUTALONG THIS LINE FROM BOTTOM TOTOP OF PAGE
BUSINESS REPLY MAIL
FIRST CLASS MAIL PERMIT NO. 10686 SANTA ANA, CA
POSTAGE WILL BE PAID BY ADDRESSEE
TECHNOLOGY CORPORATION
17600 NEWHOPE STREET
FOUNTAIN VALLEY CA 92708-9885