StorCase Technology Data Express DE110, Data Express Ultra320 DE110 User Manual

StorCase® T echnology
Data Express
®
Ultra320 DE110
Removable SCSI Wide Ultra320
Drive Enclosure
User's Guide
i
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
StorCase Technology, Inc.
17600 Newhope Street
Fountain Valley, CA 92708-9885
Phone (714) 438-1850 Fax (714) 438-1847
StorCase® Technology
Data Express
®
Ultra320 DE110
Removable
SCSI Wide Ultra320
Drive Enclosure
User's Guide
Part No. D89-0000-0245 A03 August 2006
ii
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
LIMITED WARRANTY
STORCASE TECHNOLOGY, Incorporated (“StorCase”) warrants that its products will be free from defects in material and workmanship, subject to the conditions and limitations set forth below. StorCase will, at its option, either repair or replace any part of its product that proves defective by reason of improper workmanship or materials. Repair parts or replacement products will be provided by StorCase on an exchange basis, and will be either new or reconditioned to be functionally equivalent to new.
This warranty does not cover any product damage that results from accident, abuse, misuse, natural or personal disaster, external power surge or failure, or any unauthorized disassem­bly, repair or modification. StorCase will not be responsible for any software, firmware or other customer data stored within, or interfacing with a StorCase product.
Duration of Warranty Twelve-Year Warranty: The following StorCase products are covered by this warranty for
a period of twelve (12) years from the original date of purchase from StorCase or its authorized resellers: all Data Express® Profile (model types "DX") removable device enclosures.
Seven-Year Warranty: The following StorCase products are covered by this warranty for a period of seven (7) years from the original date of purchase from StorCase or its authorized resellers: all Data Express Classic (model types "DE") removable device enclosures and all Data Silo®, Data Stacker® and InfoStation® external expansion chassis, except for those compo­nents integrated into or purchased separately for use with these products which are identified and covered by the three-year or hard drive warranties described below. All StorCase interface cables and other accessories specifically intended for use with the StorCase products identified above are also covered by this (7) year warranty.
Three-Year Warranty: The following components integrated into or purchased separately for use with StorCase Data Express, Data Silo, Data Stacker and/or InfoStation products are subject to warranty for a period of three (3) years from the original date of purchase from StorCase or its authorized resellers: all RAID controllers, power supplies, fans and blowers.
Two-Year Warranty: The following StorCase products are covered by this warranty for a period of two (2) years from the original date of purchase from StorCase or its authorized resellers: all Rhino®JR fixed external expansion chassis (model types “FJR”) and all RhinoJR removable device enclosures (model types “RJR”).
One-Year Warranty: All StorCase products identified as Reconditioned or “Special Inventory” are covered by this warranty for a period of one (1) year from the original date of purchase from StorCase or its authorized resellers. Reconditioned products may only be exchanged for reconditioned products.
Hard Disk Drive Warranty: All hard disk drives purchased from StorCase or through its authorized resellers, whether purchased separately or integrated into StorCase products, are subject to the warranty terms and conditions provided by the drive manufacturer.
Third Party Software Warranty: All third party software purchased from StorCase for use with and/or as part of StorCase products is subject to the warranty terms and conditions provided by the software manufacturer.
iii
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
Warranty Claim Requirements
To obtain warranty service, the defective product must be returned to your local authorized StorCase dealer or distributor, or, with prior StorCase approval, to the StorCase factory service center.
For defective products returned directly to StorCase, a Return Material Authorization (“RMA”) number must be obtained by calling StorCase Customer Service at (714) 445-3455. The RMA number must be prominently displayed on the outside of the return package. Shipments must be freight-prepaid and insured, and must include the product serial number, a detailed description of the problem experienced, and proof of the original retail purchase date. Products must be properly packaged to prevent damage in transit. Damage resulting from improper packaging will not be covered by this warranty. The StorCase factory service center is located at 17650 Newhope Street, Receiving Dock, Gate #4, Fountain Valley, CA 92780, U.S.A.
Free Technical Support
StorCase provides free technical support. If you experience any difficulty during the installation or subsequent use of a StorCase product, please contact StorCase’s Technical Support Department prior to servicing your system. This warranty covers only repair or replacement of defective StorCase products, as described above. StorCase is not liable for, and does not cover under warranty, any costs associated with servicing and/or installation of StorCase products.
StorCase Technical Support can be reached in the U.S. at (714) 438-1858 or toll-free at (888) 435-5460 (U.S. and Canada only). StorCase European Technical Support can be reached in the U.K. at +44 (0) 1932 738900.
Disclaimers
The foregoing is the complete warranty for the products identified above and supersedes all other warranties and representations, whether oral or written. StorCase expressly disclaims all warranties for the identified products, which are not stated herein, including, to the extent permitted by applicable law, any implied warranty of merchantability or fitness for a particular purpose. In no event will StorCase be liable to the purchaser, or to any user of a StorCase product, for any damages, expenses, lost revenues, lost savings, lost profits, or any other incidental or consequential damages arising from the purchase, use or inability to use a StorCase product, even if StorCase has been advised of the possibility
of such damages.
Copyright © 2006 StorCase Technology. All rights reserved. All registered trademarks are the property of StorCase Technology. All other logos and trademarks are properties of their respective companies.
iv
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
Declaration of Conformity
StorCase Technology, Inc.
17600 Newhope Street Fountain Valley, CA 92708
17600 Newhope Street Fountain Valley, CA 92708
Data Express Ultra320 DE110 S21A100, S21A101, S21A102, S21A103,
S21A104, S21A105
ITE Emission
- EN55022: 1998
- EN 61000-3-2 Harmonic Current
- EN 61000-3-3 Voltage Fluctuations and Flicker EN 55024: 1998 ITE Immunity
- IEC 61000-4-2 - IEC 61000-4-6
- IEC 61000-4-3 - IEC 61000-4-8
- IEC 61000-4-4 - IEC 61000-4-11
- IEC 61000-4-5
CAN/CSA-C22.2 No. 950-95 UL 1950
EN 60950: 2000 FCC Part 15, Class B AS/NZS 3548 Information Technology Equipment
Supplier's Code Number N10664 2003
Company Name:
Corporate Office Address:
Manufacturing Address:
Product Name:
Model Number:
Conforms to the following standards:
EMC Directives: (89/336/EEC)
Safety Standards: CSA (NRTL/C)
TUV
EMI Standards:
EMC Standards:
Year of Manufacture:
Signature:___________________ Full name: Dieter Paul Position: President
v
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
Table of Contents
INTRODUCTION ........................................................................................................................ 1
Packaging Information ................................................................................................... 1
Serial Numbers............................................................................................................... 1
Package Contents ......................................................................................................... 2
General Description....................................................................................................... 3
Receiving Frame Front Panel .............................................................................. 4
Drive Carrier ........................................................................................................ 5
Receiving Frame Rear Panel............................................................................... 6
INSTALLATION ........................................................................................................................ 7
Preparation..................................................................................................................... 7
Installing the Drive into the Carrier................................................................................ 7
Installing the Receiving Frame .................................................................................... 10
Spacer Plates (Optional) .............................................................................. 11
Selecting the Unit ID Number....................................................................................... 12
APPENDICES ...................................................................................................................... 15
Appendix A - Specifications/Dimensions ................................................................... 16
Appendix B - Optional Accessories ........................................................................... 18
Carrying Case.................................................................................................... 18
Appendix C - Field-Replacing the Carrier Fan ........................................................... 19
Reader's Comments............................................................................................................... 21
vi
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
List of Figures
Figure 1: Package Contents .............................................................................................. 2
Figure 2: Ultra320 DE110 Receiving Frame and Carrier .................................................. 3
Figure 3A: Receiving Frame Front Panel............................................................................. 4
Figure 3B: Receiving Frame Unit ID Number and Activity Display ..................................... 5
Figure 4: Drive Carrier ....................................................................................................... 5
Figure 5: Receiving Frame Motherboard (Rear View) ..................................................... 6
Figure 6: Drive Installation Assembly ................................................................................ 8
Figure 7: Drive Cover Installation ...................................................................................... 9
Figure 8A: Receiving Frame Mounting Holes .................................................................... 10
Figure 8B: Spacer Plate Installation (Optional) ................................................................. 11
Figure 9: Unit ID Select Switch Location ........................................................................ 13
Figure A-1: Ultra320 DE110 Physical Dimensions.............................................................. 17
Figure B-1: Carrying Case................................................................................................... 18
Figure C-1: Removing the Fan from the Carrier ................................................................. 19
NOTICE: This User's Guide is subject to periodic updates without notice. While reason-
able efforts have been made to ensure the accuracy of this document, Stor­Case Technology, Inc. assumes no liability resulting from errors or omissions in this publication, or from the use of the information contained herein.
Please check the StorCase web site at http://www.storcase.com or contact your StorCase representative for the latest revision of this document.
List of Tables
Table 1: Unit ID Display Hex Reference Table .............................................................. 13
Introduction 1
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
INTRODUCTION
Packaging Information
The StorCase Technology Data Express® system is shipped in a container designed to provide protection and prevent damage during shipment. The Data Express unit was carefully inspected before and during the packing procedure at the factory. Bent or broken connectors, or evidence of other damage to the Data Express should be reported to the shipper immediately. Refer to Figure 1 for the package contents.
If the wrong Data Express model has been received, please call your reseller or StorCase at (800) 435-0642 to arrange for a Return Material Authorization (RMA). StorCase cannot ac­cept returns which do not display an RMA number on the outside of the package. Return the unit with all the original packing materials.
Before removing any component from its packaging, discharge any static electricity by touching a properly grounded metal object.
Serial Numbers
Both the Ultra320 DE110 receiving frame and carrier are labeled with serial numbers. These numbers must be reported to the StorCase Customer Service Representative in order to receive a Return Material Authorization (RMA) for warranty claims. Locate the serial number labels and record the numbers in the spaces provided below.
Receiving Frame:
Device Carrier:
2 Introduction
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
Package Contents
NOTE: Package contents may vary, depending on model.
The Ultra320 DE110 package contents include the following items. If any item is missing or damaged, contact your StorCase dealer for a replacement.
Figure 1: Package Contents
Data Express
Drive
Carrier
D isk
Drive
(N ot Inclu
ded
)
Powe
r C
ab le
I/O Ca
ble
D rive Mou
ntin
g
Hardwa
re (4ea)
Phillips #
6-32 x
3 /16
Flat H
D
ID Select Ca
bl e
0 1 5 1
Ca
ble
Cover
(P
rovid
ed)
C able Cover
Screws (2
plcs)
# 6-32 x 3/16
Flat HD
1
0834D
3
2
4
5
6
7
8
9
One Data Express Ultra320 Removable Enclosure
Carrier & Rec. Frame
Carrier Only
Rec. Frame Only
1. Drive Carrier
2. Receiving Frame
3. Drive Cover
4. #6-32 Phillips Machine Hd. Screws
5. #6-32 Phillips Flat Hd. Screws
6. Alignment Tool
7. Drive Lock Keys
8. Spacer Plates
0834K
1
1
1
4
8
1
1 Set
2
1
1
8
4
1 Set
1
1
2
9. Insert Sheet
1
1
1
Introduction 3
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
Figure 2: Ultra320 DE110 Receiving Frame and Carrier
General Description
NOTES: Ultra320 DE110 receiving frames are indicated by their AMBER LED, while the
Ultra320 DE110 carriers are indicated by the Ultra320 logo. For SCSI Ultra320 operation, the Ultra320 DE110 requires Ultra320 drives,
Ultra320 HBA, and Ultra320-compliant cabling (internal and external).
The StorCase Technology Data Express® Ultra320 DE110 is a removable drive carrier and receiving frame, designed to provide durable and reliable mounting for one (1) low-profile (up to 1" high) 3.5" Ultra320 drive within a 5.25" half-height peripheral slot (Figure 2).
A field-replaceable fan in the front of the drive carrier provides enhanced heat dissipation (3.5 CFM). Refer to Appendix C for further information.
The Ultra320 DE110 allows a drive to be removed and transported to another Ultra320 DE110­equipped computer or expansion chassis, and also provides the ability to secure sensitive data by removing and storing the drive safely for future use.
This User's Guide describes the steps required to install the Ultra320 DE110 removable enclosure inside a computer peripheral bay or external expansion chassis. This guide supplements documentation provided with the host computer system, operating system, and the drive to be installed within the carrier.
Drive
Carrier
0834J
Receiving
Frame
4 Introduction
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
Receiving Frame Front Panel
(Figures 3A & 3B)
Unit ID Number Indicator - This AMBER LED displays the status of the Ultra320 DE110 device carrier if the carrier is Installed and Locked in the receiving frame or if the carrier is removed from the receiving frame. If the carrier is Installed but not Locked in the receiving frame, a "u" will be displayed to indicate an unlocked condition. The unit ID number is selected by means of the unit ID select switch inside the receiving frame using a special alignment tool supplied with the Ultra320 DE110 (Figure 9).
The Activity Indicator - A small AMBER dot next to the unit ID number illuminates to indicate when the host computer is accessing the data on the Ultra320 DE110 carrier. This dot will flash during communication with the host computer.
Fan Failure LED - The unit ID number indicator will display a flashing "F" and an audible alarm will sound to indicate a fan failure.
Figure 3A: Receiving Frame Front Panel
0840B
Receiving Frame
2.
AMBER Unit ID
Number Indicator
AMBER Activity
Indicator
Introduction 5
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
Figure 3B: Receiving Frame Unit ID Number and Activity Display
Drive Carrier
(Figure 4)
Key Lock/Drive Power Switch - Performs three functions. The key switch assures proper seating of the drive carrier within the receiving frame, turns power to the drive carrier ON and OFF, and prevents unauthorized removal or installation of the carrier. For the computer to access data on the disk drive, the key must be turned counterclock­wise to the locked position.
Front-Mounted Fan - Provides enhanced heat dissipation (3.5 CFM).
Figure 4: Drive Carrier
0841C
Key Lock/Drive
Power Switch
Ultra320
Logo
Front-Mounted
Fan
Carrier Installed
(unlocked)
Carrier Installed
(locked)
Carrier Removed
from Receiving Frame
The number "2" shown above is for illustration purposes only. It can be any valid unit ID number. The letter "u" and F will appear as illustrated.
0064c
Activity Indicator
Fan Failure
6 Introduction
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
Figure 5: Receiving Frame Motherboard
(Rear View)
Receiving Frame Rear Panel
(Figure 5)
I/O Connector (J3) - The input/output connector provides a standard interface for all Ultra320 signals (Figure 5).
DC Power Connector (P1) - A standard 4-pin DC power connector is used to accept DC power.
Option Pin Connector (W1) Remote Unit ID Selection: Pins 1-8 of this connector are provided for remote unit
SCSI ID selection through the computer system. Remote ID selection requires that the unit ID switch located on the inside of the receiving frame be set to "0" (onboard ID selection is set with a switch located on the inside of the receiving frame as shown in Figure 10).
Factory-Installed Jumpers: There are two (2) jumpers factory-installed on W1 (Pins 9 & 10 and 21 & 22). DO NOT remove these jumpers!
P1
DC Power Connector
(P1)
68-Pin I/O Connector
(J3)
Option Pin Connector
(W1)
Buzzer
21
22
910
Factory-Installed
Jumpers
(Do Not Remove!)
J3
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
Installation 7
INSTALLATION
NOTES: Ultra320 DE110 receiving frames are indicated by their AMBER LED, while the
Ultra320 DE110 carriers are indicated by the Ultra320 logo. For SCSI Ultra320 operation, the Ultra320 DE110 requires Ultra320 drives,
Ultra320 HBA, and Ultra320-compliant cabling (internal and external).
Preparation
NOTE: A #2 Phillips screwdriver will be required during this procedure.
While performing the steps in this section, work on a soft surface to prevent excessive shock to the drive being installed. Also refer to the manufacturer's documentation provided with the
drive.
1. Remove the drive from its protective packaging.
Installing the Drive into the Carrier
1. Carefully insert the drive into the carrier. Slide the drive towards the Drive Carrier Board, so that the I/O, DC power, and ID select connectors on the drive mate with their respective connectors on the drive carrier board (Figure 6).
2. Fasten the drive into place with four (4) #6-32 Phillips Flat Hd. screws (Figure 6).
3. Install the provided drive cover (Figure 7).
8 Installation
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
Figure 6: Drive Installation Assembly
Ultra320 Drive (Not Included)
Drive Carrier
Board
#6-32 Phillips
Flat Hd. Screw
(4 each)
Drive
Carrier
0835C
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
Installation 9
Figure 7: Drive Cover Installation
0836A
2 Slide the cover towards the back of the carrier
1 Insert this end into the carrier first
3 Secure with #6-32 Phillips Flat Hd. screws (2 Total)
10 Installation
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
Figure 8A: Receiving Frame Mounting Holes
Mounting
Holes
(Right)
Mounting
Holes
(Left)
0837
Mounting
Holes
(Bottom)
Front of Unit
Installing the Receiving Frame
NOTE: Use a #2 Phillips screwdriver for this procedure.
The drive should be installed into the carrier before installing the receiving frame into the mounting bay of a computer or expansion chassis.
1. Turn OFF power to the computer.
2. Open the computer system according to the manufacturer’s instructions. If necessary, temporarily remove any expansion boards that may make installation difficult.
3. With the drive carrier locked in place inside the receiving frame, install the Ultra320 DE110 into the 5.25” drive opening in the computer or expansion chassis. Use the appropriate guides to position the Data Express, and fasten it into place with the four (4) #6-32 Phillips screws provided. Figure 8A illustrates the location of the mounting holes. Mounting holes are provided on each side and the bottom of the receiving frame to accommodate a variety of mounting configurations. Use the mounting holes which best suit the computer or expansion chassis configuration. Note that bottom mounting holes require self-tapping screws (not provided).
4. Adjust the front of the receiving frame so the carrier slides freely in and out on the receiving frame guides. The position of adjoining peripheral units may require adjustment.
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
Installation 11
5. Connect the I/O cable from the host adapter to the receiving frame. The Pin 1 indicator on the cable must be properly aligned.
6. Connect the power cable from the DC power supply in the computer or expansion chassis to the power connector on the Ultra320 DE110 receiving frame. Refer to Figure 5 for the Ultra320 DE110 receiving frame power connector location.
7. Replace any expansion boards that may have been removed earlier. Replace the system cover according to the manufacturer’s instructions.
Spacer Plates (Optional)
NOTE: Depending on the computer system, spacer plates may be positioned on the
receiving frame to utilize either top or bottom row of side-mounting holes (Figure 8B).
The Ultra320 DE110 is designed to fit most computer systems with standard 5.25" peripheral slots. The installation of the spacer plates (provided) may or may not be necessary.
Figure 8B: Spacer Plate Installation (Optional)
Spacer Plate
(2 Total)
OR
0869
12 Installation
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
8. Reconnect any system or peripheral cables removed earlier.
9. Turn ON power to the computer. If the installation has been successful, and all the cables have been properly attached, the system should boot normally. Although the computer may not recognize the Ultra320 DE110 yet, the front panel display on the Ultra320 DE110 receiving frame should illuminate.
10. The new drive may need to be formatted or initialized prior to use with the operating system and applications software. Refer to the drive and/or computer manufacturer's documentation for formatting information.
Selecting the Unit ID Number
1. Verify that power is turned ON to the Ultra320 DE110 receiving frame by turning on your computer. A number will appear in the unit ID display window if the carrier is locked in place.
2. Unlock the Ultra320 DE110 drive carrier and remove it from the receiving frame. A "u" will be displayed initially when the unit is unlocked but will return to a number when the carrier is removed from the receiving frame.
WARNING: Unlocking the carrier unit switches DC power OFF to the drive. Since
disk drives require a short amount of time to spin down, allow about 15 seconds before pulling the carrier unit out of the receiving frame to avoid possible damage to the drive.
3. Use the alignment tool supplied with the Ultra320 DE110 to select the ID number of the disk drive. Refer to Figure 9 for the location of the ID Select Switch inside the receiving frame.
4. After you have selected an appropriate unit ID number, replace the Ultra320 DE110 carrier in the receiving frame, and LOCK IT IN PLACE.
NOTE: The lock on the Ultra320 DE110 carrier functions as a lock and a DC
power switch for the carrier unit. The lock must be engaged in order to supply power to the carrier and installed drive.
5. Reboot the computer. The new disk is now ready for use, although it may have to be formatted or initialized prior to use with your operating system and applications software.
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
Installation 13
Figure 9: Unit ID Select Switch Location
Drive Carrier
Guide
Typical Data Express
Receiving Frame
0087a
Unit ID Select Rotating Switch
Table 1: Unit ID Display Hex Reference Table
DISPLAY
(HEX)
UNIT
NUMBER (
10
)
DISPLAY
(HEX)
UNIT
NUMBER (
10
)
0 1 2 3 4 5 6 7
8
9 10 11 12 13 14 15
014
7
14 Installation
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
This Page Left Blank Intentionally.
Appendix A - Specifications/Dimensions 15
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
APPENDICES
16 Appendix A - Specifications/Dimensions
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
Appendix A - Specifications/Dimensions
Specifications and dimensions below are for reference only.
Chassis Reliability/Maintainability
MTBF
500,000 Hours
Preventive Maintenance
None
MTTR
5 minutes
Environmental Specifications
Operating
Storage
Ambient Temperature
0° C to 50° C
-40° C to 70° C
Relative Humidity
(1)
10% to 80% 10% to 90%
Altitude
-1000 to 10,000 ft
-1000 to 40,000 ft
-305m to 3048m -305m to 12195m
Shock
(2)
10g 60g
(1)
Non-condensing with maximum gradient of 10% per hour.
(2)
11 msec pulse width 1/2 sine wave.
Physical Specifications
Height Width
Depth
1.52 (38.6mm)
4.73 (120.1mm)
Weight
Receiving Frame
Carrier
8.60 (218.4mm)
5.81 (147.6mm)
1.61 (40.9mm)
7.94 (201.7mm)
1.3lb (0.59kg) 1.4lb (0.64kg)
(1)
(1)
With carrier removed.
0832C
Electrical Specifications
Input
+5V 65mA +12V 400mA
Insertion Rating
25,000
3.5 CFM
Fan Airflow
1 Fan
Appendix A - Specifications/Dimensions 17
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
Figure A-1: Ultra320 DE110 Physical Dimensions
(Dimensions are for reference only)
Receiving Frame with Carrier Installed
Carrier Only
0838B
4.73
(120.1mm)
1.52
(38.6mm)
1.75
(44.5mm)
3.75
(95.3mm)
7.94
(201.65mm)
3.12
(79.2mm)
5.81
(147.6mm)
1.61
(40.9mm)
3.12
(79.2mm)
2.06
(52.3mm)
0.47 (11.9mm)
8.60
(218.44mm)
4.19
(106.43mm)
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
18 Appendix B - Optional Accessories
Figure B-1: Carrying Case
The optional molded plastic carrying case (P/N S20E101) is designed to transport one (1) DE110 carrier from one site to another in a safe, impact and moisture-resistant environment. Its compact dimensions, 10” long x 11” wide x 4.5” high, make it easy to carry and to store. The foam lining is contoured to fit a single Data Express carrier. Contact your StorCase dealer for further details and ordering information.
Appendix B - Optional Accessories
Carrying Case
320FW_13
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
Appendix C - Field-Replacing the Carrier Fan 19
Figure C-1: Removing the Fan from the Carrier
Appendix C - Field-Replacing the Carrier Fan
NOTE: A #2 Phillips screwdriver will be required during this procedure.
While performing steps in this section, work on a soft surface to prevent ex­cessive shock to the drive and carrier.
The Ultra320 DE110 drive carrier contains one (1) front-mounted drive carrier fan for en­hanced heat dissipation. Should the fan ever fail, the unit ID number indicator (located on the front of the receiving frame) will display a flashing "F" and an audible alarm will sound. Refer to section "Receiving Frame Front Panel" in the Introduction for further information.
In the case of failure, the fan is easily field-replaceable as outlined in the steps below.
1
Remove
Screws
(2 per Side)
Front
Assembly
2
Remove
Screws
(2 Total)
Fan
3
Disconnect
Fan Cable
20 Appendix C - Field-Replacing the Carrier Fan
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
1. Carefully uninstall drive (if still installed in carrier). Refer to section "INSTALLATION" for further information.
2. Loosen and remove the four (4) #6-32 Phillips Flat Hd. screws securing the front assembly to the carrier (Step 1 of Figure C-1). Carefully remove the front assembly.
3. Uninstall the faulty fan by removing the two (2) Philips Pan Hd. screws securing the fan to the carrier (Step 2 of Figure C-1).
4. Carefully disconnect the fan power cable (Step 3 of Figure C-1).
5. To install the new fan, simply reverse above mentioned steps.
Ultra320 DE110 User's Guide - Rev. A03 StorCase Technology, Inc.
Reader's Comments 21
Reader's Comments
Please take a few moments when your computer system is up and running to send us your ideas and suggestions for improving our products and documentation. Did the installation go smoothly for you? Are there any changes you would like us to make, either with the hardware itself, or with the installation instructions? Everyone at StorCase Technology is working toward the goal of providing you with the highest quality, most cost effective, products available on the market, and we need your comments to guide our efforts. We look forward to hearing from you soon!
Date:
Your Name: Address:
Telephone: ( )
To mail this page, carefully remove it from the manual, fold it, staple or tape it shut, and drop it in the mail. To FAX this page, carefully remove it from the manual (or make a photocopy) and FAX it to us at (714) 438-1847. Thank you for taking the time to help us make our products better!
22 Reader's Comments
StorCase Technology, Inc. Ultra320 DE110 User's Guide - Rev. A03
FOLD ALONG THIS LINE AND STAPLE SHUT
CUT ALONG THIS LINE FROM BOTTOM TO TOP OF PAGE
BUSINESS REPLY MAIL
POSTAGE WILL BE PAID BY ADDRESSEE
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
FIRST CLASS MAIL PERMIT NO. 10686 SANTA ANA, CA
TECHNOLOGY CORPORATION
17600 NEWHOPE STREET FOUNTAIN VALLEY CA 92708-9885
Loading...