InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Fountain Valley, CA 92708-9885
Page 3
ii
LIMITED WARRANTY
STORCASE TECHNOLOGY, Incorporated (StorCase) warrants that its products will be free
from defects in material and workmanship, subject to the conditions and limitations set forth
below. StorCase will, at its option, either repair or replace any part of its product that proves
defective by reason of improper workmanship or materials. Repair parts or replacement
products will be provided by StorCase on an exchange basis, and will be either new or
reconditioned to be functionally equivalent to new.
This warranty does not cover any product damage that results from accident, abuse, misuse,
natural or personal disaster, external power surge or failure, or any unauthorized disassembly, repair or modification. StorCase will not be responsible for any software, firmware or other
customer data stored within, or interfacing with a StorCase product.
Duration of Warranty
Seven-Year Warranty: The following StorCase products are covered by this warranty for
a period of seven (7) years from the original date of purchase from StorCase or its authorized
reseller: all Data Express® removable device enclosures and all StorCase interface cables and
accessories specifically intended for use with these products. Data Silo®, Data Stacker® and
InfoStation® products are covered by this warranty for a period of seven (7) years, excepting
the RAID controller, power supply, fan and blower components, which are covered by the
three-year warranty described below.
Three-Year Warranty: The following StorCase products are covered by this warranty for
a period of three (3) years from the original date of purchase from StorCase or its authorized
reseller: all Rhino®JR external expansion chassis, all RhinoJR removable drive enclosures,
and all RAID controller modules. In addition, the following components of the Data Express,
Data Silo, Data Stacker, InfoStation products are subject to warranty for a period of three (3)
years: all power supplies, fans and blowers.
Warranty Claim Requirements
To obtain warranty service, the defective product must be returned to your local authorized
StorCase dealer or distributor, or, with prior StorCase approval, to the StorCase factory
service center.
For defective products returned directly to StorCase, a Return Material Authorization (RMA)
number must be obtained by calling StorCase Customer Service at (714) 445-3455. The RMA
number must be prominently displayed on the outside of the return package. Shipments must
be freight-prepaid and insured, and must include the product serial number, a detailed
description of the problem experienced, and proof of the original retail purchase date. Products
must be properly packaged to prevent damage in transit. Damage resulting from improper
packaging will not be covered by this warranty. The StorCase factory service center is located
at 3400 S. Susan Street, Storage RMA Dept., Santa Ana, California 92704, U.S.A.
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 4
Free Technical Support
StorCase provides free technical support. If you experience any difficulty during the
installation or subsequent use of a StorCase product, please contact StorCases Technical
Support Department prior to servicing your system. This warranty covers only repair or
replacement of defective StorCase products, as described above. StorCase is not liable for,
and does not cover under warranty, any costs associated with servicing and/or installation
of StorCase products.
StorCase Technical Support can be reached in the U.S. at (714) 438-1858 or toll-free at (888)
435-5460 (U.S. and Canada only). StorCase European Technical Support can be reached in
the U.K. at +44 (0) 1932 738900.
Disclaimers
The foregoing is the complete warranty for the products identified above and
supersedes all other warranties and representations, whether oral or written.
StorCase expressly disclaims all warranties for the identified products, which are
not stated herein, including, to the extent permitted by applicable law, any implied
warranty of merchantability or fitness for a particular purpose. In no event will
StorCase be liable to the purchaser, or to any user of a StorCase product, for any
damages, expenses, lost revenues, lost savings, lost profits, or any other
incidental or consequential damages arising from the purchase, use or inability
to use a StorCase product, even if StorCase has been advised of the possibility
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 5
iv
Declaration of Conformity
Company Name:
Corporate Office Address:
Manufacturing Address:
Product Name:
Model Number:
Conforms to the following standards:
EMC Directives:
(89/336/EEC)
Safety Standards:
CSA (NRTL/C)
TUV
EMI Standards:
StorCase Technology, Inc.
17600 Newhope Street
Fountain Valley, CA 92708
17600 Newhope Street
Fountain Valley, CA 92708
InfoStation 14-Bay Fibre Channel
S10D106, S10D111
ITE Emission
- EN 55022: 1998
- EN 61000-3-2 Harmonic Current
- EN 61000-3-3 Voltage Fluctuations and Flicker
EN 55024: 1998 ITE Immunity
- IEC 61000-4-2- IEC 61000-4-6
- IEC 61000-4-3- IEC 61000-4-8
- IEC 61000-4-4- IEC 61000-4-11
- IEC 61000-4-5
CAN/CSA-C22.2 No. 60950
UL 60950, Third Edition
EN 60950: 2000
FCC Part 15, Class A
EMC Standards:
Year of Manufacture:
Signature:___________________
Full Name: Dieter Paul
Position: President
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
AS/NSZ 3548 Information Technology Equipment
Supplier's Code Number N10664
2002
Page 6
Federal Communications Commission (FCC) Statement
RADIO FREQUENCY INTERFERENCE STATEMENT
You are cautioned that changes or modifications not expressly approved by the party
responsible for compliance could void your authority to operate that equipment.
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) This device must
accept any interference received, including interference that may cause undesired operation.
Important Safety Instructions
1.Read all these instructions.
2.Save these instructions for later use.
3.Follow all warnings and instructions marked on the product.
4.Do not use this product near water.
5.This product should be operated from the type of power source indicated on the
marking label. If you are not sure of the type of power available, consult your dealer
or local power company.
6.Do not attempt to service this product yourself, as opening or removing covers may
expose you to dangerous voltage points or other risk. Refer all servicing to service
personnel.
v
7.Handling certain plastic coated cords or cables associated with this product may
expose you to lead, a chemical known to cause birth defects or other reproductive
harm. Wash your hands after handling cable(s).
Wichtige Sicherheitshinweise
1.Diese Hinweise sollten vollständig durchgelesen werden.
2.Diese Hinweise für einen späteren Gebrauch aufbewahren.
3.Allen auf dem Gerät angebrachten Warnungen und Hinweisen folgen.
4.Das Gerät nicht in der Nähe von Wasser verwenden.
5.Das Gerät nur mit dem Aufkleber bezeichneten Netzspannung betreiben. Bei Fragen
über die Art der Netzspannung sollte der Händler oder das
Energieversorgungsunternehmen zu rate gezogen werden.
6.Nicht versuchen das Produkt selbst zu reparieren. In allen Produkten existieren
gefährliche elektrische Spannugen. Nicht das Gehäuse öffnen.
7.Wartungsarbeiten nur von qualifiziertern Kundendienstpersonal ausführen laßen.
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
NOTICE: This User's Guide is subject to periodic updates without notice. While reasonable
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
efforts have been made to ensure accuracy of this document, Storcase Technology, Inc. assumes no liability resulting from errors or omissions in this publication,
or from the use of the information contained herein.
Please check the StorCase web site at http://www.storcase.com or contact your
StorCase representative for the latest revision of this document.
Page 10
Introduction1
INTRODUCTION
CAUTION:The InfoStation contains NO USER SERVICEABLE parts inside the unit. Refer ALL
NOTES:The installation, configuration, and use of the StorCase InfoStation chassis
servicing to qualified service personnel!
This unit has more than one power supply cord. Disconnect two power supply
cords before servicing to avoid electric shock.
requires a certain level of expertise and experience on the part of the user/
integrator. Since there are many configuration options and variables (ie. host
platforms, applications, etc), only general/typical configuration guidelines will
be discussed in this User's Guide.
For installation information, refer to the InfoStation Installation Guide.
PackagingInformation
The StorCase Technology InfoStation external expansion chassis is shipped in a container
designed to provide protection and prevent damage during shipment, as confirmed by the
International Safe Transit Association (ISTA Procedure 1A). The InfoStation was carefully
inspected before and during the packing procedure at the factory. Evidence of any damage
to the InfoStation should be reported to the shipper immediately.
If the wrong InfoStation model has been received, please call your reseller or StorCase at
(800) 435-0642 to arrange for a Return Material Authorization (RMA). StorCase cannot accept returns which do not display an RMA number on the outside of the package. Return the
unit with all the original packing materials.
Before removing any component from its packaging, discharge any static electricity by
touching a properly grounded metal object.
Serial Number
The InfoStation is labeled with a serial number. This number must be reported to the StorCase
Customer Service Representative in order to receive a Return Material Authorization (RMA)
for warranty claims. Locate the serial number label and record the number in the space
provided below.
InfoStation Serial Number:
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 11
2Introduction
GeneralDescription
The StorCase® Technology InfoStation® intelligent 3U rack-mount expansion chassis is
designed to support the latest high-density, high-speed 2Gbps/1Gbps Fibre ChanneI disk
drive technologies for use in network server, fault-tolerant and/or mission-critical applications. The InfoStation is designed to support 3.5" form factor, low profile (1" high) Fibre
Channel drives.
The InfoStation's dual backplane design can accommodate up to fourteen (14) Fibre Channel
drives (Figure 1) and up to four (4) Fibre Channel Arbitrated Loops (FC-ALs) with 2Gbps
operation. Each chassis is constructed of rugged steel and lightweight aluminum, and is
equipped with either one (1) or two (2) 650 watt redundant, hot-swappable power supply/
blower modules, and a User Interface designed to provide visual chassis feedback.
The InfoStation options include an FC Port Bypass Module and Small Form-Factor Pluggable
(SFP) Modules, for quad FC loop configurability. Additional PBP and SFP modules are available
to accommodate a variety of configurations, interfaces, and applications. Refer to Appendix
B for further information on optional InfoStation accessories.
The InfoStation also incorporates "Soft Start" circuitry which eliminates in-rush current to each
of the installed drives during spin-up, as well as avoid power arcing during drive insertion.
Another unique feature of the InfoStation is the InfoMon® monitoring utility program. InfoMon
is a console utility that provides the InfoStation with web-based monitoring capability via a serial
connection. InfoMon also provides the User the ability to easily configure both device and
chassis settings with a few clicks of the mouse!
In addition, InfoMon allows the User to monitor the statuses and temperatures of individual
InfoStation modules and drive bays, etc., and can provide "real-time" updates via an Internet
connection. With the recent addition of the InfoMon Call Home feature, this information can
also be sent to a specific site for access by StorCase technical support staff in order to assist
with system troubleshooting. The Call Home feature also provides the ability to set-up a paging
function for notification of environmental alarm or warning conditions.
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 12
Introduction3
The latest versions of the InfoMon utility program and User's Guide can be downloaded (free
of charge) from the StorCase web site (http://www.storcase.com). Contact StorCase for
further information. Refer to Appendix B for further information on optional InfoStation
accessories.
Using a modular approach supported by redundant features and hot swapping capabilities,
the InfoStation will provide continued data availability and allow for ease of maintenance and
minimal system down time.
The modular and scalable design of the InfoStation chassis also allows a variety of future
product upgrades to be offered. Upgrade modules (providing remote diagnostics capabilities
and SES or SNMP compliance) will also be available as options in the near future.
This User's Guide describes the steps required for installing drive(s) into the InfoStation
external expansion chassis. This guide is intended to supplement documentation provided with
the host computer system, the operating system, and the drive(s) to be installed within the
InfoStation.
Features:
3U rack mount chassis
Fourteen (14) removable low-profile drive carriers
Capable of 2Gbps or 1Gbps FC-AL/FC-SW operation
Supports single, dual, or quad FC-AL configurations
Configurable for 7 or 14 drive loops
Connection flexibility with optical or copper SFP Modules
Supports clustering
Supports daisy-chaining
Supports drive hot swapping
User Interface Panel provides configuration and communication status
RS-232 serial port provides interface for monitoring, configuration, and control
Scalable backplane design
Corrosion-resistant steel construction
One (1) or two (2) 650W hot-swappable power supply/blower modules (depending on
model). P.S. Module contains two (2) high-pressure/variable-speed blowers.
Status indicators on each drive carrier
7-year limited warranty* and free 24/7 technical support
* 3 year limited warranty on Power & Cooling Modules
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 13
4Introduction
FrontPanel
(Figure 2)
LED Indicator and Control Panel - LED panel displays system statuses, alarms,
and warnings. Refer to section "InfoStation User Interface" for further information.
SCA Drive Carrier(s) - Accommodate up to fourteen (14) 3.5" low-profile Fibre
Channel devices. Backplane design with direct-connect SCA connectors eliminates
cable connections to FC drives, increases data integrity, and supports drive hot
swappability.
Drive Carrier LED(s) - Provides the following information:
Drive Ready -Indicates that the drive is properly installed and ready for
Drive Activity -Indicates that the drive is being accessed.
Drive Fault -Indicates a drive failure.
Key Lock(s) - Assure proper seating of the drive carrier within the chassis and
prevent unauthorized removal or installation of the carrier.
access.
NOTE:The key lock is only to prevent unauthorized removal or installation of the
drive carrier. Locking the key lock is not requried for drive carrier operation.
Chassis Handle(s) - Provide a sturdy grip for the installation and removal of the
rack-mount chassis.
SCA Drive
Carrier
Drive Carrier
Handle
LED Indicator and
Control Panel
RS-232
Serial Port
Key
Lock
Drive Carrier
LEDs
Chassis
Handle
14FC_02
Figure 2: InfoStation Front Panel
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 14
Introduction5
RearPanel
(Figure 3)
NOTE:Blank plate (provided) must be installed if any module slot is left empty. Instal-
Port Bypass Module "A" (Figure 4)- InfoStation comes equipped with one (1) Port
Port Bypass Module "B" Option - Allows the installation of an optional PBP
Power Supply/Blower Module(s) - Depending on the model, either one (1) or
lation of the blank plate is necessary for proper cooling inside chassis.
Bypass (PBP) Module, for dual FC loop configurability.
Module, for quad loop configurability. Refer to Appendix B for further information.
two (2) 650W redundant, hot swappable power supply modules. Each module
features overvoltage and overcurrent protection, total usage hours, and power
supply fault detection.
Each module also contains two (2) high-pressure, variable-speed blowers for ample
chassis cooling (79 CFM per module).
WARNING:DO NOT USE MODULE HANDLES TO LIFT CHASSIS! These
handles are specifically designed for the installation and removal of modules only!
Module LED(s) -
Green LED -Steady glow indicates normal power supply operation.
No glow indicates no A/C power or abnormal DC voltage range.
Red LED -Flashing indicates temperature or over/undervoltage condi-
tions.
Power Switch(es) - Rocker switch(es) control power to the power supply
module(s).
A/C Power In - Accepts U.S. and other available international standard power
cords.
Module Option - Allows the installation of StorCase upgrade products such as an
optional SNMP upgrade module. Refer to Appendix B for further information.
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 15
6Introduction
Power Supply
Handle
Captive
Screw
Power Supply
Module #2
A/C
Power In
Blower
Vent
Power
Switch
Module
Option
Port Bypass
Module A
Port Bypass
Module B
Option
Figure 3: InfoStation Rear Panel
(Dual Power Supply/Blower Module Version shown)
Power Supply
Module #1
Power Supply
Module LEDs
14FC_03
Loop BLoop A
InInOutOut
PBP Module
Handle
Locking
Thumbscrew
SFP
Cages
HSSDC2
SFP Module
(Optional)
14FC_04
LEDs
Figure 4: Port Bypass Module
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 16
User Interface7
INFOSTATION USER INTERFACE
LED Indicator and Control Panel
Each InfoStation provides the user with a visual indication of chassis configurations and
communication statuses, in addition to providing an RS-232 connection for system environmental monitoring, configuration, and control (Figure 5).
Warning
Mute
2Gbps
RS-232
Serial Port
RB Com
Power
Fault
Override
Bypass
Reset
RA Com
Select
14FC_06
Figure 5: LED Indicator and Control Panel
LED Indicator/Control Panel Components
Power (Green)-ON = Power to the chassis is on.
Warning (Amber) -ON = One or more warning conditions
Fault (Red) -ON = One or more fault conditions
Mute (Amber) -ON = Audible alarm is disabled
Override (Amber) -ON = Warning condition commands are overridden
NOTE:Factory default is OFF (recommended).
2Gbps -ON = 2Gbps operation (Factory Default)
OFF = 1Gbps operation
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 17
8User Interface
Bypass -ON = One or more drives are being bypassed
Reset -Resets InfoStation User Interface Module (will not reset FC
RS-232 Serial Port -RS-232 serial connection used for InfoStation external monitor-
RA Com -Factory Reserved
RB Com -Factory Reserved
Select Button -Factory Reserved
loops)
ing and configuration
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 18
User Interface9
Drive Carrier Interface Panel
Each InfoStation drive carrier provides a User interface for individual carrier operation.
LEDs
Drive
Drive
Drive
Fault
Carrier
Handle
Ready
Activity
Figure 6: InfoStation Drive Carrier Interface
The Drive Carrier Interface consists of the following indicators:
Table 1: Drive Carrier Interface Components
Key
Lock
IFS14_3
Drive Ready LED
Drive Activity LED
Drive Fault LED
Steady glow indicates that drive is inserted
and ready for access.
Flashing indicates that drive is inserted and
in the process of being powered up.
Steady glow indicates drive is being accessed.
Steady glow indicates drive failure.
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 19
10User Interface
Inserting a Drive Carrier (with Drive Installed)
NOTES:A new drive can be inserted into an empty bay at anytime. However, the drive
1. Simply insert the drive carrier into the empty bay.
2. Drive is ready to be accessed when the Drive Ready LED glows.
.
will not be ready for access until the following procedure is followed.
The key lock is only to prevent unauthorized removal or installation of the drive
carrier. Locking the key lock is not required for drive carrier operation.
Removing a Drive Carrier (with Drive Installed)
CAUTION:Proper procedure must be followed when removing a disk drive from the drive
NOTE:Refer to the InfoStation Installation Guide for detailed information on inserting/
1. Verify that the Drive Activity LED is OFF before removing drive.
bay. It is the responsibility of the operator to ensure that the host does not
access the drive while attempting to remove the disk drive, and to follow the
procedure outlined below. Failure to do so may result in loss of data and/or
damage to the drive itself!
removing drives from the InfoStation chassis.
2. Unlock the key lock (if locked) and remove the drive carrier by pulling on carrier handle.
Configuring Device and Chassis Settings
NOTE:Refer to the InfoMon User's Guide for further information.
If necessary, use InfoMon to change any factory default device or chassis settings. Please
refer to the InfoMon User's Guide for further information.
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 20
Fibre Channel Configurations11
FIBRE CHANNEL CONFIGURATIONS
Port Bypass (PBP) Module
CAUTION:DO NOT bend the LC (optical) cable beyond the cable's minimum bend radius,
data transmission degradation may occur. Follow cable manufacturer's
guidelines for bend radius limitation.
WARNING:DO NOT look directly into the open end of an active LC (optical) cable or optical
SFP module (with plugs removed)! Serious eye damage can occur from direct
exposure to the infrared light!
NOTES:PBP Module is NOT hot-swappable! Remove ALL power to chassis before
removing and installing the PBP Module. Refer to the InfoStation Installation
Guide for further information.
SFP Module is hot-swappable. The chassis may remain on when removing and
installing the SFP Module.
HSSDC2 (copper) SFP Modules support 1Gbps operation only.
LC (optical) SFP Modules support both 2Gbps and 1Gbps operation.
Auto Loopback is enabled when there are no SFP Modules installed in the open
Host ports.
An additional PBP Module is available as an upgrade. Contact StorCase for
further ordering information.
Loop BLoop A
InInOutOut
PBP Module
Handle
LEDs
14FC_04
Locking
Thumbscrew
SFP
Cages
HSSDC2
SFP Module
(Optional)
Figure 7: PBP Module
SFP Cages -Four (4) cages accept optional SFP Modules and allow for two (2) FC-AL
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 21
12Fibre Channel Configurations
DIAG
Loop A
Data In Error
Loop B
Data In Error
All Bypass
Loop A
Data Out Error
Loop B
Data Out Error
Figure 8: PBP Module LEDs
PBP Module LEDs
DIAGON =Communication link to UI has failed
OFF =Normal operation
All BypassON =All drives are forced into bypass
Loop AON =Error detected in the Loop A data input
Data In Error
Loop AON =Error detected in the Loop A data output
Data Out Error
Loop BON =Error detected in the Loop B data input
Data In Error
Loop BON =Error detected in the Loop B data output
Data Out Error
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 22
Fibre Channel Configurations13
SFP Module and Cable Installation
CAUTION:DO NOT bend the LC (optical) cable beyond the cable's minimum bend radius,
WARNING:DO NOT look directly into the open end of an active LC (optical) cable or optical
NOTES:SFP Module is hot-swappable. The chassis may remain on when removing and
Depending on model, your InfoStation may or may not have been shipped with SFP Modules
already installed. If already installed, skip Step 1 and proceed with Step 2.
1.Carefully insert SFP Module(s) into the appropriate SFP cages (depending on FC
data transmission degradation may occur. Follow cable manufacturer's
guidelines for bend radius limitation.
SFP module (with plugs removed)! Serious eye damage can occur from direct
exposure to the infrared light!
installing the SFP Module.
HSSDC2 (copper) SFP Modules support 1Gbps operation only.
LC (optical) SFP Modules support both 2Gbps and 1Gbps operation.
Auto Loopback is enabled when there are no SFP Modules installed in the open
Host ports.
An additional PBP Module is available as an upgrade. Contact StorCase for
further ordering information.
configuration) located on the PBP Module (Figures 9A & 9B). Insert and push the
SFP Module until it "clicks" into place.
WARNING:To avoid possible damage to the LC (optical) SFP Module, make sure the Release
Refer to Figures 11-16 for further information on FC configurations.
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Lever is on top before inserting SFP Module into the PBP Module (Figure 9A)!
To avoid possible damage to the HSSDC2 (copper) SFP Module, make sure the
Release Tab is on the bottom before inserting the SFP Module into the PBP
Module (Figure 9B)!
Page 23
14Fibre Channel Configurations
Figure 9A: Installing the LC (optical) SFP Module into the PBP Module
Figure 9B: Installing the HSSDC2 (copper) SFP Module into the PBP Module
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 24
Fibre Channel Configurations15
2.Remove the SFP plugs (Figure 9A) and install the cables into the SFP Modules (Figure
WARNING:DO NOT look directly into the open end of an active LC (optical) cable or optical
10). Make sure to remove any cable plugs from the cables prior to installation (if
necessary). Save SFP and cable plugs for future use!
SFP module (with plugs removed)! Serious eye damage can occur from direct
exposure to the infrared light!
Figure 10: Installing the Cables into the SFP Modules
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 25
16Fibre Channel Configurations
3.To remove SFP Module from PBP Module, remove any cables installed in the SFP
WARNING:DO NOT look directly into the open end of an active LC (optical) cable or optical
Module.
For Optical SFP Modules, lower the Release Lever and pull the SFP Module from PBP
Module (Figure 11).
For HSSDC2 SFP Modules, squeeze the Release Tab while pulling the SFP Module
from the PBP Module.
SFP module (with plugs removed)! Serious eye damage can occur from direct
exposure to the infrared light!
Figure 11: Removing the Optical SFP Module from the PBP Module
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 26
Fibre Channel Configurations17
FC Loop and Speed Configuration
NOTES:Factory default configuration is Dual Loop at 2Gbps.
Refer to the InfoMon User's Guide for further information.
If necessary, use InfoMon to change any factory default device or chassis settings. Please
refer to the InfoMon User's Guide for further information.
Hardware Compatibility
To assure maximum system compatibility and performance, StorCase recommends Seagate
Fibre drives for use in our InfoStation Fibre backplane enclosures.
Please contact StorCase Technical Support to obtain specific part numbers for the latest
StorCase-qualified Fibre drives, as well as recommendations regarding the compatibility of
specific RAID controllers with the InfoStation enclosure.
®
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 27
18Fibre Channel Configurations
TYPICAL FIBRE CHANNEL CONFIGURATIONS
NOTES:The installation, configuration, and use of the StorCase InfoStation chassis
requires a certain level of expertise and experience on the part of the user/
integrator. Since there are many configuration options and variables (ie. host
platforms, applications, etc), only general/typical configuration guidelines will
be discussed in this User's Guide.
For redundant loop configurations, make sure your O/S supports disk duplexing/
mirroring. Refer to O/S manufacturer's documentation for further information.
An additional PBP Module is available as an upgrade. Contact StorCase for
further ordering information.
NOTES:Auto Loopback is enabled when there are no SFP Modules installed in the open
Host ports.
SFP modules are optional. Contact StorCase for further ordering information.
Up to 9 InfoStations or 126 FC Drives maximum.
FC-AL #1
FC HBA
Host 0
= No SFP
Module Installed
(Auto Loopback)
= SFP Module
PC
Installed
Figure 12: Typical Single 14-Device Loop Configuration (Single Chassis)
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 28
Fibre Channel Configurations19
NOTES:Auto Loopback is enabled when there are no SFP Modules installed in the open
Host ports.
SFP modules are optional. Contact StorCase for further ordering information.
Up to 9 InfoStations or 126 FC Drives maximum.
FC-AL #1
FC HBA
Host 0
= No SFP
Module Installed
(Auto Loopback)
= SFP Module
PC
Installed
Figure 13: Typical Single 14-Device Loop Configuration (Multiple Chassis)
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 29
20Fibre Channel Configurations
NOTES:Auto Loopback is enabled when there are no SFP Modules installed in the open
Host ports.
SFP modules are optional. Contact StorCase for further ordering information.
Up to 9 InfoStations or 126 FC Drives maximum.
For redundant loop configurations, make sure your O/S supports disk
duplexing/mirroring. Refer to O/S manufacturers documentation for further
information.
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 31
22Fibre Channel Configurations
NOTES:Auto Loopback is enabled when there are no SFP Modules installed in the open
Host ports.
SFP modules are optional. Contact StorCase for further ordering information.
Up to 9 InfoStations or 126 FC Drives maximum.
For redundant loop configurations, make sure your O/S supports disk
duplexing/mirroring. Refer to O/S manufacturers documentation for further
information.
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 32
Fibre Channel Configurations23
NOTES:Auto Loopback is enabled when there are no SFP Modules installed in the open
Host ports.
SFP modules are optional. Contact StorCase for further ordering information.
Up to 9 InfoStations or 126 FC Drives maximum
FC-AL #2
FC HBA
Host 3
FC-AL #4
FC HBA
Host 2
FC HBA
Host 1
FC-AL #3
FC-AL #1
FC HBA
Host 0
PC
PC
= No SFP
Module Installed
(Auto Loopback)
= SFP Module
Installed
PC
PC
Figure 17: Typical Quad Loops Configuration
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 33
24Fibre Channel Configurations
This Page Left Blank Intentionally.
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 34
Appendix A - Specifications/Dimensions25
APPENDICES
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 35
26Appendix A - Specifications/Dimensions
Appendix A - Specifications/Dimensions
The following InfoStation specifications and dimensions are provided for reference only.
Environmental Specifications
Ambient Temperature0° C to 35° C-40° C to 70° C
Relative Humidity
Altitude
(2)
Shock
(1)
Non-condensing with maximum gradient of 10% per hour
(2)
11 msec pulse width 1/2 sine wave
(1)
10% to 80%10% to 90%
-1000 to 10,000 ft-1000 to 40,000 ft
-305m to 3048m-305m to 12195m
10g60g
Operating
Storage
Physical
Specifications
Height
Width
Rack Mount
5.21" (132.3mm)
16.92" (429.8mm)
Depth20.98" (532.9mm)
Weight
(1)
Weight of empty chassis (no drives installed) and 1
P. S. Module. 62.0 lbs with 2 P. S. Modules
52.0 lbs (28.6kg)
Chassis Reliability/Maintainability
MTBF100,000 Hours
Preventive
Maintenance
Power Supply Module
I/O Module
Electrical
Specifications
(1)
(per 650W Power Supply Module)
AC Input
100 to 120VAC or 200 to 240VAC, 50/60 Hz
DC Output
Cooling
(per Blower Module)
5V at 53A, 12V at 32A
79 CFM
14FC_specs1
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 36
Appendix A - Specifications/Dimensions27
StorCase InfoStation
Fibre Channel
Rack Mount Enclosure
14 Bay
# of BaySupported14
# of Drive Carriers Included14
Max. # of Drives Supported14
Max. Storage Capacity2.05TB
(Based on 147GB Drives)
Hot SwappableYes
LED Status IndicatorsYes
InterfaceSCA
ProtocolFibre Channel
Transfer Rate2 Gbps
User Interface LED Read-Out andYes
Control Panel
# of Power Supply/Blower Modules1 or 2
RedundantYes
Hot SwappableYes
Speed-VariableAuto
Blowers/Fans2 Blowers/Module
# of PBP Modules1 or 2
Max. # of Configurable FC Loops4
Data Rate
HSSDC2 (copper)1Gbps
LC (optical)2Gbps/1Gbps
Maximum Cable Length
HSSDC2 (copper)5m
LC (optical) -62.5/125 um150m
-50/125 um300m
(2Gbps)
(2Gbps)
/ 300m
/ 500m
(1Gbps)
(1Gbps)
Optical Wavelength (LC only)850 nm
Distributed Environmental MonitoringYes
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 37
28Appendix A - Specifications/Dimensions
StorCase InfoStation
Fibre Channel Rack Mount Enclosure
External Monitoring UtilityYes
via RS-232 Port
Power-On-Hour (POH)Yes
Monitoring
Audible AlarmYes
Standard 19 Rack-MountHeight = 3U
Technical SupportToll-Free
Limited Warranty7 Years*
Regulatory Approvals
EMIFCC/CE/C-tick
Safety AgencyCSA/CSA US/TUV
* 3 year limited warranty on Power & Cooling Modules.
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 38
Appendix A - Specifications/Dimensions29
16.92
(429.8mm)
18.98
(482.1mm)
20.57
(522.5mm)
Top View
Right Side ViewFront View
(532.9mm)
20.98
14FC_dims
5.21
(132.3mm)
Figure A-1: InfoStation Physical Dimensions
(Dimensions are for reference only)
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 39
30Appendix B - Optional Accessories
Appendix B - Optional Accessories
Port Bypass Module
The InfoStation's scalable backplane design allows additional modules to be offered,
supporting a variety of FC configurations. An additional PBP module (P/N S10D107) is available to upgrade the InfoStation for quad loop applications.
Contact StorCase for further ordering information.
14FC_12
Figure B-1: PBP Module
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 40
Appendix B - Optional Accessories31
SFP Modules
HSSDC2 (Copper) SFP Module
(P/N S10D108)
14FC_14
Figure B-2: HSSDC2 (Copper) SFP Modules
LC (Optical) SFP Module
(P/N S10D114)
14FC_15
Figure B-3: LC (Optical) SFP Modules
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 41
32Appendix B - Optional Accessories
Patch Cable Kit
(P/N S90D100)
Figure B-4: Patch Cable Kit
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 42
Appendix B - Optional Accessories33
Slide Rail Kit
The optional slide rail kit (P/N DXRCK-SLIDE) provides a convenient method to attach the
InfoStation to a rack mount enclosure (Figure B-5). These high quality, durable rails provide
24 ball bearing rollers and have a quick-release button which allows quick and easy installation
and removal of the InfoStation unit from its rack enclosure. Contact StorCase for further
ordering information.
IFS14_29
Figure B-5: Rack Mount Slide Rail Kit
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 43
34Appendix B - Optional Accessories
Optional Power Supply/Blower Module
CAUTION:The power supply/blower module contains NO USER SERVICEABLE
PARTS inside the unit. Warranty is VOID if module is opened. Refer ALL
servicing to qualified service personnel!
NOTE:Refer to the InfoStation Installation Guide for further information.
An optional second 650W power supply module (P/N S10D109) is available for the InfoStation
chassis as shown in Figure B-6. Contact StorCase for further ordering information.
14FC_13
Figure B-6: Power Supply/Blower Module
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 44
Appendix B - Optional Accessories35
Drive Carrier
Spare drive carriers (P/N S10A116) are available for the InfoStation chassis as shown in Figure
B-7. Contact StorCase for further ordering information.
IFS14_25
Figure B-7: Drive Carrier
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 45
36Appendix B - Optional Accessories
Carrying Case
(Figure B-8)
The optional molded plastic carrying case (P/N S20E104) is designed to transport the
InfoStation drive carrier from one site to another in a safe, impact and moisture resistant
environment. Its compact dimensions, 7" long x 9" wide x 4" high, make it easy to carry and
store. The foam lining is contoured to fit a single InfoStation carrier. Contact your StorCase
dealer for further details and ordering information.
320FW_13
Figure B-8: Carrying Case
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 46
Appendix B - Optional Accessories37
Rack-to-Tower Conversion Kit
This kit (P/N S10E100) provides all the parts necessary to convert an existing rack mount
InfoStation to a tower conversion as shown in Figure B-9. Contact StorCase for further
ordering information.
Pan Hd.
Screw
(1 Total)
Pan Hd.
Screw
(4 Total)
Hex Nut*
(4 Total)
Right Cover
F.H. Screw
(1 per Side)
Left
Cover
Bezel*
Top Cover
Base
To p
Cover
F.H. Screw*
(4 Total)
Base
Pan Hd.
Screw
(4 Total)
* Chassis handles and mounting flanges must be removed prior to installation.
Figure B-9: Rack-to-Tower Conversion Kit
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 47
38Appendix B - Optional Accessories
InfoStation Monitoring Utility (InfoMon®)
InfoMon is a web-based monitoring utility that runs under the Windows O/S. This free utility
(and its accompanying User's Guide) is available for download at the StorCase web site
(http://www.storcase.com).
The primary purpose of InfoMon is to continuously monitor the environmental status and
indicate alarm conditions inside the InfoStation chassis via a serial connection to a PC. InfoMon
also provides the User the ability to easily configure both device and chassis settings with
a few clicks of the mouse!
In addition, InfoMon allows the User to monitor the statuses and temperatures of individual
InfoStation modules and drive bays, etc., and can provide "real-time" updates via an Internet
connection. With the recent addition of the InfoMon Call Home feature, this information can
also be sent to a specific site for access by StorCase technical support staff in order to assist
with system troubleshooting. The Call Home feature also provides the ability to set-up a paging
function for notification of environmental alarm or warning conditions.
To install and operate the InfoMon software, the computer system must meet the following
requirements:
Operating System:Microsoft® Windows® 95/98/NT/2000/XP
CPU:IBM-compatible 486 or higher
Memory:32MB RAM
Hard Disk Space:12MB
Internet Connection:Required only if monitoring via the web
Internet Browser:Microsoft Internet Explorer 5.0 (or higher) or
Netscape Communicator 4.7 (or higher)
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Page 48
Reader's Comments39
Reader's Comments
Please take a few moments when your computer system is up and running to send us your
ideas and suggestions for improving our products and documentation. Did the installation go
smoothly for you? Are there any changes you would like us to make, either with the hardware
itself, or with the installation instructions? Everyone at StorCase Technology is working
toward the goal of providing you with the highest quality, most cost effective, products
available on the market, and we need your comments to guide our efforts. We look forward
to hearing from you soon!
Date:
Your Name:
Address:
Telephone: ()
To mail this page, carefully remove it from the manual, fold it, staple or tape it shut, and drop
it in the mail. To FAX this page, carefully remove it from the manual (or make a photocopy) and
FAX it to us at (714) 438-1847. Thank you for taking the time to help us make our products
better!
InfoStation 14-Bay FC User's Guide - Rev. B00StorCase Technology, Inc.
Page 49
40Reader's Comments
FOLD ALONG THIS LINE AND STAPLE SHUT
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
CUTALONG THIS LINE FROM BOTTOM TOTOP OF PAGE
BUSINESS REPLY MAIL
FIRST CLASS MAIL PERMIT NO. 10686 SANTA ANA, CA
POSTAGE WILL BE PAID BY ADDRESSEE
TECHNOLOGY CORPORATION
17600 NEWHOPE STREET
FOUNTAIN VALLEY CA 92708-9885
StorCase Technology, Inc.InfoStation 14-Bay FC User's Guide - Rev. B00
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.