StorCase Technology 14-Bay 3U Fibre User Manual

StorCase® Technology
InfoSt ation
14-Bay 2Gbps Fibre Channel External Expansion Chassis
User's Guide
®
StorCase® Technology
InfoSt ation
®
14-Bay 2Gbps Fibre Channel
External Expansion Chassis
User's Guide
Part No. D89-0000-0210 B00 October 2003
StorCase Technology, Inc.
17600 Newhope Street
Phone (714) 438-1850 Fax (714) 438-1847
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
Fountain Valley, CA 92708-9885
ii
LIMITED WARRANTY
STORCASE TECHNOLOGY, Incorporated (StorCase) warrants that its products will be free from defects in material and workmanship, subject to the conditions and limitations set forth below. StorCase will, at its option, either repair or replace any part of its product that proves defective by reason of improper workmanship or materials. Repair parts or replacement products will be provided by StorCase on an exchange basis, and will be either new or reconditioned to be functionally equivalent to new.
This warranty does not cover any product damage that results from accident, abuse, misuse, natural or personal disaster, external power surge or failure, or any unauthorized disassem­bly, repair or modification. StorCase will not be responsible for any software, firmware or other customer data stored within, or interfacing with a StorCase product.
Duration of Warranty
Seven-Year Warranty: The following StorCase products are covered by this warranty for
a period of seven (7) years from the original date of purchase from StorCase or its authorized reseller: all Data Express® removable device enclosures and all StorCase interface cables and accessories specifically intended for use with these products. Data Silo®, Data Stacker® and InfoStation® products are covered by this warranty for a period of seven (7) years, excepting the RAID controller, power supply, fan and blower components, which are covered by the three-year warranty described below.
Three-Year Warranty: The following StorCase products are covered by this warranty for a period of three (3) years from the original date of purchase from StorCase or its authorized reseller: all Rhino®JR external expansion chassis, all RhinoJR removable drive enclosures, and all RAID controller modules. In addition, the following components of the Data Express, Data Silo, Data Stacker, InfoStation products are subject to warranty for a period of three (3) years: all power supplies, fans and blowers.
Warranty Claim Requirements
To obtain warranty service, the defective product must be returned to your local authorized StorCase dealer or distributor, or, with prior StorCase approval, to the StorCase factory service center.
For defective products returned directly to StorCase, a Return Material Authorization (RMA) number must be obtained by calling StorCase Customer Service at (714) 445-3455. The RMA number must be prominently displayed on the outside of the return package. Shipments must be freight-prepaid and insured, and must include the product serial number, a detailed description of the problem experienced, and proof of the original retail purchase date. Products must be properly packaged to prevent damage in transit. Damage resulting from improper packaging will not be covered by this warranty. The StorCase factory service center is located at 3400 S. Susan Street, Storage RMA Dept., Santa Ana, California 92704, U.S.A.
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Free Technical Support
StorCase provides free technical support. If you experience any difficulty during the installation or subsequent use of a StorCase product, please contact StorCases Technical Support Department prior to servicing your system. This warranty covers only repair or replacement of defective StorCase products, as described above. StorCase is not liable for, and does not cover under warranty, any costs associated with servicing and/or installation of StorCase products.
StorCase Technical Support can be reached in the U.S. at (714) 438-1858 or toll-free at (888) 435-5460 (U.S. and Canada only). StorCase European Technical Support can be reached in the U.K. at +44 (0) 1932 738900.
Disclaimers
The foregoing is the complete warranty for the products identified above and supersedes all other warranties and representations, whether oral or written. StorCase expressly disclaims all warranties for the identified products, which are not stated herein, including, to the extent permitted by applicable law, any implied warranty of merchantability or fitness for a particular purpose. In no event will StorCase be liable to the purchaser, or to any user of a StorCase product, for any damages, expenses, lost revenues, lost savings, lost profits, or any other incidental or consequential damages arising from the purchase, use or inability to use a StorCase product, even if StorCase has been advised of the possibility
of such damages.
iii
Copyright © 2003 StorCase Technology. All rights reserved. All registered trademarks are the property of StorCase Technology. All other logos and trademarks are properties of their respective companies.
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
iv
Declaration of Conformity
Company Name:
Corporate Office Address:
Manufacturing Address:
Product Name:
Model Number:
Conforms to the following standards:
EMC Directives: (89/336/EEC)
Safety Standards: CSA (NRTL/C)
TUV
EMI Standards:
StorCase Technology, Inc.
17600 Newhope Street Fountain Valley, CA 92708
17600 Newhope Street Fountain Valley, CA 92708
InfoStation 14-Bay Fibre Channel
S10D106, S10D111
ITE Emission
- EN 55022: 1998
- EN 61000-3-2 Harmonic Current
- EN 61000-3-3 Voltage Fluctuations and Flicker EN 55024: 1998 ITE Immunity
- IEC 61000-4-2 - IEC 61000-4-6
- IEC 61000-4-3 - IEC 61000-4-8
- IEC 61000-4-4 - IEC 61000-4-11
- IEC 61000-4-5
CAN/CSA-C22.2 No. 60950 UL 60950, Third Edition
EN 60950: 2000
FCC Part 15, Class A
EMC Standards:
Year of Manufacture:
Signature:___________________ Full Name: Dieter Paul Position: President
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
AS/NSZ 3548 Information Technology Equipment Supplier's Code Number N10664
2002
Federal Communications Commission (FCC) Statement
RADIO FREQUENCY INTERFERENCE STATEMENT
You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate that equipment.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Important Safety Instructions
1. Read all these instructions.
2. Save these instructions for later use.
3. Follow all warnings and instructions marked on the product.
4. Do not use this product near water.
5. This product should be operated from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company.
6. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous voltage points or other risk. Refer all servicing to service personnel.
v
7. Handling certain plastic coated cords or cables associated with this product may expose you to lead, a chemical known to cause birth defects or other reproductive harm. Wash your hands after handling cable(s).
Wichtige Sicherheitshinweise
1. Diese Hinweise sollten vollständig durchgelesen werden.
2. Diese Hinweise für einen späteren Gebrauch aufbewahren.
3. Allen auf dem Gerät angebrachten Warnungen und Hinweisen folgen.
4. Das Gerät nicht in der Nähe von Wasser verwenden.
5. Das Gerät nur mit dem Aufkleber bezeichneten Netzspannung betreiben. Bei Fragen über die Art der Netzspannung sollte der Händler oder das Energieversorgungsunternehmen zu rate gezogen werden.
6. Nicht versuchen das Produkt selbst zu reparieren. In allen Produkten existieren gefährliche elektrische Spannugen. Nicht das Gehäuse öffnen.
7. Wartungsarbeiten nur von qualifiziertern Kundendienstpersonal ausführen laßen.
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
vi
Table of Contents
INTRODUCTION ..................................................................................................................... 1
Packaging Information .................................................................................................. 1
Serial Number ................................................................................................................ 1
General Description ...................................................................................................... 2
Front Panel ............................................................................................................ 4
Rear Panel ............................................................................................................. 5
INFOSTATION USER INTERFACE ......................................................................................... 7
LED Indicator and Control Panel ................................................................................... 7
LED Indicator/Control Panel Components ............................................................ 7
Drive Carrier Interface Panel ............................................................................... 9
Inserting a Drive Carrier (with Drive Installed) .......................................................... 10
Removing a Drive Carrier (with Drive Installed) ....................................................... 10
Configuring Device and Chassis Settings ................................................................. 10
FIBRE CHANNEL CONFIGURATIONS ................................................................................. 11
Port Bypass (PBP) Module ......................................................................................... 11
PBP Module LEDs ............................................................................................... 12
SFP Module and Cable Installation ............................................................................. 13
FC Loop and Speed Configuration ............................................................................. 17
Hardware Compatibility .............................................................................................. 17
TYPICAL FIBRE CHANNEL CONFIGURATIONS ................................................................. 18
APPENDICES ........................................................................................................................ 25
Appendix A - Specifications/Dimensions .................................................................. 26
Appendix B - Optional Accessories ......................................................................... 30
Port Bypass Module ........................................................................................... 30
SFP Modules ....................................................................................................... 31
HSSDC2 (Copper) SFP Module.................................................................. 31
LC (Optical) SFP Module ............................................................................ 31
Patch Cable Kit ................................................................................................... 32
Slide Rail Kit......................................................................................................... 33
Optional Power Supply/Blower Module ............................................................ 34
Drive Carrier ........................................................................................................ 35
Carrying Case ..................................................................................................... 36
Rack-to-Tower Conversion Kit .......................................................................... 37
InfoStation Monitoring Utility (InfoMon) .............................................................. 38
Reader's Comments............................................................................................................ 39
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
List of Figures
Figure 1: InfoStation 14-Bay FC Chassis ..................................................................... 2
Figure 2: InfoStation Front Panel ................................................................................... 4
Figure 3: InfoStation Rear Panel .................................................................................... 6
Figure 4: Port Bypass Module ....................................................................................... 6
Figure 5: LED Indicator and Control Panel .................................................................... 7
Figure 6: InfoStation Drive Carrier Interface ................................................................ 9
Figure 7: PBP Module ................................................................................................... 11
Figure 8: PBP Module LEDs ......................................................................................... 12
Figure 9A: Installing the LC (optical) SFP Module into the PBP Module ....................... 14
Figure 9B: Installing the HSSDC2 (copper) SFP Module into the PBP Module............. 14
Figure 10: Installing the Cables into the SFP Modules ................................................. 15
Figure 11: Removing the Optical SFP Module from the PBP Module ........................... 16
Figure 12: Typical Single Loop 1x14 Configuration (Single Chassis) ......................... 18
Figure 13: Typical Single Loop 1x14 Configuration (Multiple Chassis) ....................... 19
Figure 14: Typical Dual Loop 1x14 Configuration with Loop Redundancy ................ 20
Figure 15: Typical Dual Loop 1x7 Configuration .......................................................... 21
Figure 16: Typical Dual Loop 1x7 Configuration with Loop Redundancy .................. 22
Figure 17: Typical Quad Loop 1x7 Configuration ........................................................ 23
Figure A-1: InfoStation Physical Dimensions.................................................................. 29
Figure B-1: PBP Module ................................................................................................... 30
Figure B-2: HSSDC2 (copper) SFP Modules .................................................................. 31
Figure B-3: LC (optical) SFP Modules ............................................................................. 31
Figure B-4: Patch Cable Kit ............................................................................................. 32
Figure B-5: Rack Mount Slide Rail Kit .............................................................................. 33
Figure B-6: Power Supply/Blower Module..................................................................... 34
Figure B-7: Drive Carrier ................................................................................................. 35
Figure B-8: Carrying Case ............................................................................................... 36
Figure B-9: Rack-to-Tower Conversion Kit .................................................................... 37
vii
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
viii
List of Tables
Table 1: Drive Carrier Interface Components ................................................................... 9
NOTICE: This User's Guide is subject to periodic updates without notice. While reasonable
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
efforts have been made to ensure accuracy of this document, Storcase Technol­ogy, Inc. assumes no liability resulting from errors or omissions in this publication, or from the use of the information contained herein.
Please check the StorCase web site at http://www.storcase.com or contact your StorCase representative for the latest revision of this document.
Introduction 1
INTRODUCTION
CAUTION: The InfoStation contains NO USER SERVICEABLE parts inside the unit. Refer ALL
NOTES: The installation, configuration, and use of the StorCase InfoStation chassis
servicing to qualified service personnel!
This unit has more than one power supply cord. Disconnect two power supply cords before servicing to avoid electric shock.
requires a certain level of expertise and experience on the part of the user/ integrator. Since there are many configuration options and variables (ie. host platforms, applications, etc), only general/typical configuration guidelines will be discussed in this User's Guide.
For installation information, refer to the InfoStation Installation Guide.
PackagingInformation
The StorCase Technology InfoStation external expansion chassis is shipped in a container designed to provide protection and prevent damage during shipment, as confirmed by the International Safe Transit Association (ISTA Procedure 1A). The InfoStation was carefully inspected before and during the packing procedure at the factory. Evidence of any damage to the InfoStation should be reported to the shipper immediately.
If the wrong InfoStation model has been received, please call your reseller or StorCase at (800) 435-0642 to arrange for a Return Material Authorization (RMA). StorCase cannot ac­cept returns which do not display an RMA number on the outside of the package. Return the unit with all the original packing materials.
Before removing any component from its packaging, discharge any static electricity by touching a properly grounded metal object.
Serial Number
The InfoStation is labeled with a serial number. This number must be reported to the StorCase Customer Service Representative in order to receive a Return Material Authorization (RMA) for warranty claims. Locate the serial number label and record the number in the space provided below.
InfoStation Serial Number:
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
2 Introduction
GeneralDescription
The StorCase® Technology InfoStation® intelligent 3U rack-mount expansion chassis is designed to support the latest high-density, high-speed 2Gbps/1Gbps Fibre ChanneI disk drive technologies for use in network server, fault-tolerant and/or mission-critical applica­tions. The InfoStation is designed to support 3.5" form factor, low profile (1" high) Fibre Channel drives.
The InfoStation's dual backplane design can accommodate up to fourteen (14) Fibre Channel drives (Figure 1) and up to four (4) Fibre Channel Arbitrated Loops (FC-ALs) with 2Gbps operation. Each chassis is constructed of rugged steel and lightweight aluminum, and is equipped with either one (1) or two (2) 650 watt redundant, hot-swappable power supply/ blower modules, and a User Interface designed to provide visual chassis feedback.
The InfoStation options include an FC Port Bypass Module and Small Form-Factor Pluggable (SFP) Modules, for quad FC loop configurability. Additional PBP and SFP modules are available to accommodate a variety of configurations, interfaces, and applications. Refer to Appendix B for further information on optional InfoStation accessories.
The InfoStation also incorporates "Soft Start" circuitry which eliminates in-rush current to each of the installed drives during spin-up, as well as avoid power arcing during drive insertion.
Another unique feature of the InfoStation is the InfoMon® monitoring utility program. InfoMon is a console utility that provides the InfoStation with web-based monitoring capability via a serial connection. InfoMon also provides the User the ability to easily configure both device and chassis settings with a few clicks of the mouse!
In addition, InfoMon allows the User to monitor the statuses and temperatures of individual InfoStation modules and drive bays, etc., and can provide "real-time" updates via an Internet connection. With the recent addition of the InfoMon Call Home feature, this information can also be sent to a specific site for access by StorCase technical support staff in order to assist with system troubleshooting. The Call Home feature also provides the ability to set-up a paging function for notification of environmental alarm or warning conditions.
14FC_01
Figure 1: InfoStation 14-Bay Fibre Channel Chassis
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Introduction 3
The latest versions of the InfoMon utility program and User's Guide can be downloaded (free of charge) from the StorCase web site (http://www.storcase.com). Contact StorCase for further information. Refer to Appendix B for further information on optional InfoStation accessories.
Using a modular approach supported by redundant features and hot swapping capabilities, the InfoStation will provide continued data availability and allow for ease of maintenance and minimal system down time.
The modular and scalable design of the InfoStation chassis also allows a variety of future product upgrades to be offered. Upgrade modules (providing remote diagnostics capabilities and SES or SNMP compliance) will also be available as options in the near future.
This User's Guide describes the steps required for installing drive(s) into the InfoStation external expansion chassis. This guide is intended to supplement documentation provided with the host computer system, the operating system, and the drive(s) to be installed within the InfoStation.
Features:
 3U rack mount chassis  Fourteen (14) removable low-profile drive carriers  Capable of 2Gbps or 1Gbps FC-AL/FC-SW operation  Supports single, dual, or quad FC-AL configurations  Configurable for 7 or 14 drive loops  Connection flexibility with optical or copper SFP Modules  Supports clustering  Supports daisy-chaining  Supports drive hot swapping  User Interface Panel provides configuration and communication status  RS-232 serial port provides interface for monitoring, configuration, and control  Scalable backplane design  Corrosion-resistant steel construction  One (1) or two (2) 650W hot-swappable power supply/blower modules (depending on
model). P.S. Module contains two (2) high-pressure/variable-speed blowers.
 Audible alarm
"Soft Start" circuitry Web-based monitoring utility (InfoMon)
 Status indicators on each drive carrier  7-year limited warranty* and free 24/7 technical support
* 3 year limited warranty on Power & Cooling Modules
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
4 Introduction
FrontPanel
(Figure 2)
LED Indicator and Control Panel - LED panel displays system statuses, alarms,
and warnings. Refer to section "InfoStation User Interface" for further information.
SCA Drive Carrier(s) - Accommodate up to fourteen (14) 3.5" low-profile Fibre
Channel devices. Backplane design with direct-connect SCA connectors eliminates cable connections to FC drives, increases data integrity, and supports drive hot swappability.
Drive Carrier LED(s) - Provides the following information:
Drive Ready - Indicates that the drive is properly installed and ready for
Drive Activity - Indicates that the drive is being accessed. Drive Fault - Indicates a drive failure.
Key Lock(s) - Assure proper seating of the drive carrier within the chassis and
prevent unauthorized removal or installation of the carrier.
access.
NOTE: The key lock is only to prevent unauthorized removal or installation of the
drive carrier. Locking the key lock is not requried for drive carrier oper­ation.
Chassis Handle(s) - Provide a sturdy grip for the installation and removal of the
rack-mount chassis.
SCA Drive
Carrier
Drive Carrier
Handle
LED Indicator and
Control Panel
RS-232
Serial Port
Key
Lock
Drive Carrier
LEDs
Chassis
Handle
14FC_02
Figure 2: InfoStation Front Panel
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Introduction 5
RearPanel
(Figure 3)
NOTE: Blank plate (provided) must be installed if any module slot is left empty. Instal-
Port Bypass Module "A" (Figure 4) - InfoStation comes equipped with one (1) Port
Port Bypass Module "B" Option - Allows the installation of an optional PBP
Power Supply/Blower Module(s) - Depending on the model, either one (1) or
lation of the blank plate is necessary for proper cooling inside chassis.
Bypass (PBP) Module, for dual FC loop configurability.
Module, for quad loop configurability. Refer to Appendix B for further information.
two (2) 650W redundant, hot swappable power supply modules. Each module features overvoltage and overcurrent protection, total usage hours, and power supply fault detection.
Each module also contains two (2) high-pressure, variable-speed blowers for ample chassis cooling (79 CFM per module).
WARNING: DO NOT USE MODULE HANDLES TO LIFT CHASSIS! These
handles are specifically designed for the installation and re­moval of modules only!
Module LED(s) -
Green LED - Steady glow indicates normal power supply operation.
No glow indicates no A/C power or abnormal DC voltage range.
Red LED - Flashing indicates temperature or over/undervoltage condi-
tions.
Power Switch(es) - Rocker switch(es) control power to the power supply module(s).
A/C Power In - Accepts U.S. and other available international standard power cords.
Module Option - Allows the installation of StorCase upgrade products such as an
optional SNMP upgrade module. Refer to Appendix B for further information.
InfoStation 14-Bay FC User's Guide - Rev. B00 StorCase Technology, Inc.
6 Introduction
Power Supply
Handle
Captive
Screw
Power Supply
Module #2
A/C
Power In
Blower
Vent
Power Switch
Module
Option
Port Bypass
Module A
Port Bypass
Module B
Option
Figure 3: InfoStation Rear Panel
(Dual Power Supply/Blower Module Version shown)
Power Supply
Module #1
Power Supply Module LEDs
14FC_03
Loop B Loop A
In InOut Out
PBP Module
Handle
Locking
Thumbscrew
SFP
Cages
HSSDC2
SFP Module
(Optional)
14FC_04
LEDs
Figure 4: Port Bypass Module
StorCase Technology, Inc. InfoStation 14-Bay FC User's Guide - Rev. B00
Loading...
+ 34 hidden pages