StorCase Technology 12-Bay 4U Fibre SATA JBOD User Manual

StorCase® Technology
InfoSt ation
12-Bay FC-to-Serial ATA JBOD External Expansion Chassis
User's Guide
®
StorCase® Technology
InfoSt ation
®
12-Bay FC-to-Serial ATA JBOD
External Expansion Chassis
User's Guide
Part No. D89-0000-0251 A00 April 2004
StorCase Technology, Inc.
17600 Newhope Street
Phone (714) 438-1850 Fax (714) 438-1847
InfoStation 12-Bay JBOD User's Guide - Rev. A00 StorCase Technology, Inc.
Fountain Valley, CA 92708-9885
ii
LIMITED WARRANTY
STORCASE TECHNOLOGY, Incorporated (StorCase) warrants that its products will be free from defects in material and workmanship, subject to the conditions and limitations set forth below. StorCase will, at its option, either repair or replace any part of its product that proves defective by reason of improper workmanship or materials. Repair parts or replacement products will be provided by StorCase on an exchange basis, and will be either new or reconditioned to be functionally equivalent to new.
This warranty does not cover any product damage that results from accident, abuse, misuse, natural or personal disaster, external power surge or failure, or any unauthorized disassem­bly, repair or modification. StorCase will not be responsible for any software, firmware or other customer data stored within, or interfacing with a StorCase product.
Duration of Warranty
Seven-Year Warranty: The following StorCase products are covered by this warranty for a
period of seven (7) years from the original date of purchase from StorCase or its authorized resellers: all Data Express® removable device enclosures and all Data Silo®, Data Stacker® and InfoStation® external expansion chassis, except for those components integrated into or purchased separately for use with these products which are identified and covered by the three­year or hard drive warranties described below. All StorCase interface cables and other accessories specifically intended for use with the StorCase products identified above are also covered by this (7) year warranty.
Three-Year Warranty: The following components integrated into or purchased separately for use with StorCase Data Express, Data Silo, Data Stacker and/or InfoStation products are subject to warranty for a period of three (3) years from the original date of purchase from StorCase or its authorized resellers: all RAID controllers, power supplies, fans and blowers.
Two-Year Warranty: The following StorCase products are covered by this warranty for a period of two (2) years from the original date of purchase from StorCase or its authorized resellers: all Rhino®JR fixed external expansion chassis (model types FJR) and all RhinoJR removable device enclosures (model types RJR).
One-Year Warranty: All StorCase products identified as Reconditioned or Special Inventory are covered by this warranty for a period of one (1) year from the original date of purchase from StorCase or its authorized resellers. Reconditioned products may only be exchanged for reconditioned products.
Hard Disk Drive Warranty: All hard disk drives purchased from StorCase or through its authorized resellers, whether purchased separately or integrated into StorCase products, are subject to the warranty terms and conditions provided by the drive manufacturer.
StorCase Technology, Inc. InfoStation 12-Bay JBOD User's Guide - Rev. A00
Warranty Claim Requirements
To obtain warranty service, the defective product must be returned to your local authorized StorCase dealer or distributor, or, with prior StorCase approval, to the StorCase factory service center.
For defective products returned directly to StorCase, a Return Material Authorization (RMA) number must be obtained by calling StorCase Customer Service at (714) 445-3455. The RMA number must be prominently displayed on the outside of the return package. Shipments must be freight-prepaid and insured, and must include the product serial number, a detailed description of the problem experienced, and proof of the original retail purchase date. Products must be properly packaged to prevent damage in transit. Damage resulting from improper packaging will not be covered by this warranty. The StorCase factory service center is located at 17650 Newhope Street, Receiving Dock, Gate #4, Fountain Valley, CA 92780, U.S.A.
Free Technical Support
StorCase provides free technical support. If you experience any difficulty during the installation or subsequent use of a StorCase product, please contact StorCases Technical Support Department prior to servicing your system. This warranty covers only repair or replacement of defective StorCase products, as described above. StorCase is not liable for, and does not cover under warranty, any costs associated with servicing and/or installation of StorCase products.
StorCase Technical Support can be reached in the U.S. at (714) 438-1858 or toll-free at (888) 435-5460 (U.S. and Canada only). StorCase European Technical Support can be reached in the U.K. at +44 (0) 1932 738900.
iii
Disclaimers
The foregoing is the complete warranty for the products identified above and supersedes all other warranties and representations, whether oral or written. StorCase expressly disclaims all warranties for the identified products, which are not stated herein, including, to the extent permitted by applicable law, any implied warranty of merchantability or fitness for a particular purpose. In no event will StorCase be liable to the purchaser, or to any user of a StorCase product, for any damages, expenses, lost revenues, lost savings, lost profits, or any other incidental or consequential damages arising from the purchase, use or inability to use a StorCase product, even if StorCase has been advised of the possibility
of such damages.
Copyright © 2004 StorCase Technology. All rights reserved. All registered trademarks are the property of StorCase Technology. All other logos and trademarks are properties of their respective companies.
InfoStation 12-Bay JBOD User's Guide - Rev. A00 StorCase Technology, Inc.
iv
Declaration of Conformity
Company Name:
Corporate Office Address:
Manufacturing Address:
Product Name:
Model Number:
Conforms to the following standards:
EMC Directives: (89/336/EEC)
Low Voltage Directive: (73/23/EEC)
Safety Standards: CSA (NRTL/C)
StorCase Technology, Inc.
17600 Newhope Street Fountain Valley, CA 92708
17600 Newhope Street Fountain Valley, CA 92708
InfoStation 12-Bay FC-to-SATA JBOD Chassis
S10K105, S10K106
ITE Emission
- EN 55022: 1998
- EN 61000-3-2 Harmonic Current
- EN 61000-3-3 Voltage Fluctuations and Flicker EN 55024: 1998 ITE Immunity
- IEC 61000-4-2 - IEC 61000-4-5
- IEC 61000-4-3 - IEC 61000-4-6
- IEC 61000-4-4 - IEC 61000-4-8
- IEC 61000-4-11
EN 60950
CAN/CSA-C22.2 No. 60950 UL 60950, Third Edition
TUV
EMI Standards:
EMC Standards:
Year of Manufacture:
Signature:___________________ Full name: Dieter Paul Position: President
StorCase Technology, Inc. InfoStation 12-Bay JBOD User's Guide - Rev. A00
EN 60950: 2000
FCC Part 15, Class A
AS/NSZ 3548 Information Technology Equipment Supplier's Code Number N10664
2004
Federal Communications Commission (FCC) Statement
RADIO FREQUENCY INTERFERENCE STATEMENT
You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate that equipment.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Important Safety Instructions
1. Read all these instructions.
2. Save these instructions for later use.
3. Follow all warnings and instructions marked on the product.
4. Do not use this product near water.
5. This product should be operated from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company.
6. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous voltage points or other risk. Refer all servicing to service personnel.
v
Wichtige Sicherheitshinweise
1. Diese Hinweise sollten vollständig durchgelesen werden.
2. Diese Hinweise für einen späteren Gebrauch aufbewahren.
3. Allen auf dem Gerät angebrachten Warnungen und Hinweisen folgen.
4. Das Gerät nicht in der Nähe von Wasser verwenden.
5. Das Gerät nur mit dem Aufkleber bezeichneten Netzspannung betreiben. Bei Fragen über die Art der Netzspannung sollte der Händler oder das Energieversorgungsunternehmen zu rate gezogen werden.
6. Nicht versuchen das Produkt selbst zu reparieren. In allen Produkten existieren gefährliche elektrische Spannugen. Nicht das Gehäuse öffnen.
7. Wartungsarbeiten nur von qualifiziertern Kundendienstpersonal ausführen laßen.
InfoStation 12-Bay JBOD User's Guide - Rev. A00 StorCase Technology, Inc.
vi
Table of Contents
INTRODUCTION ..................................................................................................................... 1
Packaging Information .................................................................................................. 1
Serial Number................................................................................................................ 1
General Description ...................................................................................................... 2
Front Panel ............................................................................................................ 5
Rear Panel............................................................................................................. 6
LED Indicator and User Interface Panel ...................................................................... 8
LED Indicator/UI Panel Components .................................................................... 8
Drive Carrier Interface Panel ............................................................................... 9
Inserting a Drice Carrier (with Drive Installed) ................................................. 10
Removing a Drive Carrier (with Drive Installed) ............................................... 10
Configuring Device and Chassis Settings ........................................................ 10
TYPICAL SCSI CHANNEL CONFIGURATION ..................................................................... 11
TYPICAL FIBRE CHANNEL CONFIGURATION .................................................................... 12
JBOD CONTROLLER CONFIGURATION ............................................................................. 13
Configuration Overview ............................................................................................. 13
Operation Mode........................................................................................................... 15
Mode Operation........................................................................................................... 16
Self-Diagnostic Mode ......................................................................................... 16
Configuration Mode ............................................................................................ 16
Configuring the JBOD Controller ................................................................................ 17
0 JBOD Params .................................................................................................. 18
0.1 Stripe Size ........................................................................................... 18
0.2 Performance ........................................................................................ 18
1 JBOD Info ........................................................................................................ 19
1.1 Disk Info ............................................................................................... 19
1.2 Environment Info ................................................................................. 19
2 System Params .............................................................................................. 20
2.1 Terminal Port........................................................................................ 21
2.1.1 Baud Rate .................................................................................... 21
2.1.2 Stop Bit ......................................................................................... 21
2.1.3 Data Bit ......................................................................................... 21
2.1.4 Parity Bit ....................................................................................... 21
2.2 UPS Port Set ........................................................................................ 21
2.2.1 UPS Interrupt ................................................................................ 21
2.2.2 UPS Port 1 .................................................................................... 22
2.2.3 UPS Port 2 .................................................................................... 22
2.2.4 UPS Port 3 .................................................................................... 22
2.2.5 UPS Port 4 .................................................................................... 22
2.3 Password Info .................................................................................... 22
2.3.1 Password Check ......................................................................... 22
2.3.2 Set Password .............................................................................. 22
2.4 Beeper ................................................................................................. 22
2.5 Update ROM ........................................................................................ 22
StorCase Technology, Inc. InfoStation 12-Bay JBOD User's Guide - Rev. A00
3 NVRAM ........................................................................................................... 23
3.1 Update NVRAM ................................................................................... 23
3.2 Erase NVRAM ..................................................................................... 23
3.3 Restart ................................................................................................. 23
Starting the Monitor Utility................................................................................................... 24
Selecting Menu Options.............................................................................................. 26
Using DataMaster Storage Manager ................................................................. 26
APPENDICES ........................................................................................................................ 27
Appendix A - Specifications/Dimensions .................................................................. 28
Appendix B - Optional Accessories.......................................................................... 30
Slide Rail Kit ......................................................................................................... 31
Optional Power Supply Module .......................................................................... 32
Replacement Fan Module ................................................................................... 33
Drive Carrier ........................................................................................................ 34
SFP Module ......................................................................................................... 35
Carrying Case ..................................................................................................... 36
InfoStation Monitoring Utility (InfoMon) .............................................................. 37
Reader's Comments............................................................................................................ 39
vii
InfoStation 12-Bay JBOD User's Guide - Rev. A00 StorCase Technology, Inc.
viii
List of Figures
Figure 1: InfoStation 12-Bay JBOD Chassis ................................................................. 4
Figure 2: Front Panel ...................................................................................................... 5
Figure 3: Rear Panel ...................................................................................................... 7
Figure 4: UI Module ......................................................................................................... 8
Figure 5: InfoStation Drive Carrier Interface ................................................................ 9
Figure 6: FC Ports and LEDs ....................................................................................... 11
Figure 7: Typical Dual FC Loops Connection to InfoStation ...................................... 12
Figure 8: LCD Display and Control Panel .................................................................... 13
Figure 9: DB9 Port Location......................................................................................... 24
Figure 10: Monitor Utility Screen ................................................................................... 25
Figure A-1: InfoStation Physical Dimensions.................................................................. 30
Figure B-1: Rack Mount Slide Rail Kit .............................................................................. 31
Figure B-2: Power Supply Module .................................................................................. 32
Figure B-3: Fan Module ................................................................................................... 33
Figure B-4: Drive Carrier ................................................................................................. 34
Figure B-5: LC (optical) SFP Module ............................................................................... 35
Figure B-6: Carrying Case ............................................................................................... 36
List of Tables
Table 1: Drive Carrier Interface Components ................................................................... 9
Table 2: LCD Display Components ................................................................................... 14
Table 3: Main Menu Options ............................................................................................. 17
Table 4: Terminal Program Communications Parameters ............................................... 25
Table 5: Selecting Menu Options ..................................................................................... 26
NOTICE: This User's Guide is subject to periodic updates without notice. While reason-
StorCase Technology, Inc. InfoStation 12-Bay JBOD User's Guide - Rev. A00
able efforts have been made to ensure accuracy of this document, Storcase Technology, Inc. assumes no liability resulting from errors or omissions in this publication, or from the use of the information contained herein.
Please check the StorCase web site at http://www.storcase.com or contact your StorCase representative for the latest revision of this document.
Introduction 1
INTRODUCTION
PackagingInformation
The StorCase Technology InfoStation external expansion chassis is shipped in a container designed to provide protection and prevent damage during shipment, as confirmed by the International Safe Transit Association (ISTA Procedure 1A). The InfoStation was carefully inspected before and during the packing procedure at the factory. Evidence of any damage to the InfoStation should be reported to the shipper immediately.
If the wrong InfoStation model has been received, please call your reseller or StorCase at (800) 435-0642 to arrange for a Return Material Authorization (RMA). StorCase cannot ac­cept returns which do not display an RMA number on the outside of the package. Return the unit with all the original packing materials.
Before removing any component from its packaging, discharge any static electricity by touching a properly grounded metal object.
Serial Number
The InfoStation is labeled with a serial number. This number must be reported to the StorCase Customer Service Representative in order to receive a Return Material Authorization (RMA) for warranty claims. Locate the serial number label and record the number in the space provided below.
InfoStation Serial Number:
InfoStation 12-Bay JBOD User's Guide - Rev. A00 StorCase Technology, Inc.
2 Introduction
GeneralDescription
CAUTION: The InfoStation chassis contains NO USER SERVICEABLE parts inside the unit.
NOTES: The configuration and use of the InfoStation JBOD Controller requires a certain
InfoStation 12-bay FC-to-Serial ATA JBOD enclosures (P/Ns S10K105 & S10K106) are designed to support low-profile Serial ATA (SATA) or Parallel ATA (Ultra ATA/100) drives for JBOD applications and support dual Fibre Channel Arbitrated Loops (FC-ALs) with 2Gbps operation.
Each standard 4U rack mount 12-bay JBOD InfoStation chassis comes equipped with a JBOD controller, (12) removable drive carriers and an open 5.25" half-height device bay. These enclosures are constructed of corrosion-resistant steel and each include (2) hot-swappable, redundant 460W power supply modules and (2) hot-swappable, redundant, variable-speed fan modules.
An audible alarm on the InfoStation alerts the User to system hardware failures and warning conditions. LED indicators at each drive bay provide additional User feedback for drive activity, drive readiness and drive faults.
The InfoStation also incorporates "Soft Start" circuitry which eliminates in-rush current to each of the installed drives during spin-up, as well as avoid power arcing during drive insertion.
Refer ALL servicing to qualified personnel!
level of expertise and experience on the part of the user/integrator. Since there are many configuration options and variables (ie. host platforms, applications, etc.), only general guidelines will be discussed in this User's Guide.
Refer to the disk manufacturer's documentation for specific information re­garding the disks.
A User Interface Module on the 12-bay InfoStation provides the User with a visual indication of chassis configurations and communication statuses, in addition to providing an RS232 connection for system environmental monitoring, configuration and control. InfoMon®, a downloadable chassis monitoring utility program, provides the InfoStation with a customizable, web-based monitoring capability via the RS-232 serial connection. InfoMon includes a Call Home feature, which enables chassis log information to be conveniently sent to a predeter­mined FTP site for trouble shooting and analysis. InfoMon also provides the User the ability to easily configure both device and chassis settings with a few clicks of the mouse! Refer to Appendix B for further information on InfoMon.
StorCase Technology, Inc. InfoStation 12-Bay JBOD User's Guide - Rev. A00
Introduction 3
The latest versions of the InfoMon utility program and User's Guide can be downloaded (free of charge) from the StorCase web site (http://www.storcase.com). Contact StorCase for further information. Refer to Appendix B for further information on optional InfoStation accessories.
Using a modular approach supported by redundant features and hot swapping capabilities, the InfoStation will provide continued data availability and allow for ease of maintenance and minimal system down time.
The modular and scalable design of the InfoStation chassis also allows a variety of future product upgrades to be offered. Upgrade modules are anticipated InfoStation options.
This User's Guide describes the steps required for installing drive(s) into the InfoStation external expansion chassis. This guide is intended to supplement documentation provided with the host computer system, the operating system, and the drive(s) to be installed within the InfoStation.
Features:
4U Rack Mount Chassis One (1) 5.25" half-height bay (for canister-type SCSI device) Supports dual FC-ALs Supports either twelve (12) Serial ATA or Ultra ATA/100 drives Corrosion-resistant steel construction Two (2) 460W hot-swappable power supply modules Two (2) hot-swappable variable-speed fan modules Audible alarm Status indicators at each bay "Soft Start" circuitry Web-based monitoring utility (InfoMon) Data Master® Storage Manager GUI  Fax/Pager notification OS independent (no software or special drivers required) RS-232 connector for system environmental monitoring, configuration, and control 128MB PC2100 DDR SODIMM memory 7-year limited warranty* and free 24/7 technical support
* 3-year limited warranty on JBOD controller and Power & Cooling Modules
InfoStation 12-Bay JBOD User's Guide - Rev. A00 StorCase Technology, Inc.
4 Introduction
Figure 1: InfoStation 12-Bay JBOD Chassis
StorCase Technology, Inc. InfoStation 12-Bay JBOD User's Guide - Rev. A00
Introduction 5
FrontPanel
(Figure 2)
5.25" Bay - One bay can accommodate one (1) half-height SCSI device.
JBOD Control Panel - Refer to Figure 8.
Drive Carrier(s) - Accommodate up to twelve (12) 3.5" low-profile Parallel ATA or
Serial ATA devices. Backplane design eliminates cable connections to drives, increases data integrity, and supports drive hot swappability.
Drive Carrier LED(s) - Provides the following information:
Drive Ready (Blue) - Indicates that the drive is properly installed and ready
Drive Fault (Red) - Indicates a drive failure.
Drive Activity (Amber) - Indicates that the drive is being accessed.
Refer to Figure 5 & Table 1 for further information.
Key Lock(s) - Assure proper seating of the drive carrier within the chassis and
prevent unauthorized removal or installation of the carrier.
for access.
NOTE: The key lock is only to prevent unauthorized removal or installation of the
drive carrier. Locking the key lock is not requried for drive carrier oper­ation.
Chassis Handle(s) - Provide a sturdy grip for the installation and removal of the
rack-mount chassis.
5.25 Bay
Panel
Drive Carrier
Drive Carrier
LEDs
Handle
Key
Lock
Chassis
Handle
JBOD
Control
Figure 2: Front Panel
InfoStation 12-Bay JBOD User's Guide - Rev. A00 StorCase Technology, Inc.
6 Introduction
RearPanel
(Figure 3)
NOTE: Blank plate (provided) must be installed if any module slot is left empty. Instal-
UI Module - LED panel displays system statuses, alarms, and warnings. Refer to
I/O Panel - Provides two (2) DB9 connectors for RS-232 and Modem, and two (2)
Power Supply Module(s) - Two (2) 460W redundant, hot swappable power
lation of the blank plate is necessary for proper cooling inside chassis.
section "User Interface Module" for further information.
FC ports for dual FC-ALs. Also provides space for up to four (4) extra I/Os if desired.
supply modules. Each module features overvoltage and overcurrent protection, total usage hours, and power supply fault detection.
Module LED(s) -
Green LED - Steady glow indicates normal power supply operation.
No glow indicates no A/C power.
Red LED - Steady glow indicates either:
Power supply failure.
or
A/C cord is plugged in, but power switch is in the OFF position.
WARNING: DO NOT USE MODULE HANDLES TO LIFT CHASSIS! These
handles are specifically designed for the installation and re­moval of modules only!
Power Switch(es) - Rocker switch(es) control power to the power supply module(s).
A/C Power In - Accepts U.S. and other available international standard power cables.
Fan Module(s) - Two (2) redundant, hot swappable fan modules. Each module
contains two (2) high-pressure, variable-speed fans for ample chassis cooling (160 CFM per module).
Module Option - Allows the installation of StorCase upgrade products such as an
optional SNMP upgrade module. Contact StorCase for further information.
StorCase Technology, Inc. InfoStation 12-Bay JBOD User's Guide - Rev. A00