STIEBEL ELTRON Tempra 36 User Manual [en, es, fr]

English
TM 22, TempraTM 24, TempraTM 29, TempraTM 36
TANKLESS ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER AND ELECTRICIAN
Español
CALENTADORES DE AGUA SIN TANQUE INSTRUCCIONES PARA LA INSTALACIÓN POR UN PLOMERO Y ELECTRICISTA AUTORIZADO
Français
CHAUFFE-EAU INSTANTANÉS ÉLECTRIQUES INSTRUCTIONS DE MONTAGE POUR PLOMBIERS ET ÉLECTRICIENS AGRÉÉSN
TEMPRA 12, TEMPRA 15, TEMPRA 20, TEMPRA 24
P ow
er
°C
26_02_02_0604
TEMPRA 22, TEMPRA 29, TEMPRA 36
Pow
er
°C
26_02_02_0605
English Table of contents
Table showing temperature increase above ambient water temperature 2 General 6 Mounting the unit 6 Water connections 6 Electrical connections 7 Putting the water heater into operation 7 Normal maintenance 7 Technical Data 7 Troubleshooting 8 Spare parts 8 Warranty 16
Español Índice de materias
Aumento máximo de temperatura del agua fría entrante 2 Características generales de la unidad 9 Colocación y montaje 10 Conexiones de agua 10 Conexión eléctrica 10 Arranque inicial 10 Mantenimiento rutinario 10 Datos técnicos 11 Identificación y resolución de problemas 11 Repuestos 11 Garantía 15
Français Sommaire
Tableau indiquant montée en température au-dessus de la température d’eau ambiante 2 Généralités 9 Montage de l’appareil 9 Raccords d’eau 9 Connexions électriques 10 Mise en service du chauffe-eau 10 Entretien de routine 10 Caractéristiques techniques 11 Dépannage 11 Pièces de rechange 12 Garantie 16
264655
English
Maximum temperature increase above ambient water temperature
Español
Français
Warm water fl ow rate Flujo de agua caliente Débit d‘eau chaude
Warm water outlet temperature Temperatura del agua caliente Température de sortie d‘eau chaude
Cold water inlet temperature °F °C agua fría temperatura de entrada
Température d‘entrée d‘eau froide 39 50 59 68 77 4 10 15 20 25
TEMPRA 12 @ 208 V 9 kW 0.95 1.14 1.36 1.70 2.27 3.58 4.30 5.16 6.44 8.59 @ 220 - 240 V 12 kW 1.26 1.51 1.82 2.27 3.03 4.77 5.73 6.87 8.59 11.46
TEMPRA 15 @ 208 V 10,8 kW 1,14 1,36 1,63 2,04 2,72 4,30 5,16 6,19 7,73 10,31 @ 220 - 240 V 14,4 kW 1,51 1,82 2,18 2,72 3,63 5,73 6,87 8,25 10,31 13,75
TEMPRA 20 @ 208 V 14.4 kW 1.51 1.82 2.18 2.72 3.63 5.73 6.87 8.25 10.31 13.75 @ 220 - 240 V 19.2 kW 2.02 2.42 2.91 3.63 4.84 7.64 9.16 11.00 13.75 18.33
TEMPRA 22 @ 208 V 16,2 kW 1,70 2,04 2,45 3,06 4,09 6,44 7,73 9,28 11,60 15,47 @ 220 - 240 V 21,6 kW 2.27 2.72 3.27 4.09 5.45 8.59 10.31 12.37 15.47 20.62
TEMPRA 24 @ 208 V 18 kW 1.89 2.27 2.72 3.41 4.54 7.16 8.59 10.31 12.89 17.18 @ 220 - 240 V 24 kW 2.52 3.03 3.63 4.54 6.05 9.55 11.46 13.75 17.18 22.91
TEMPRA 29 @ 208 V 21.6 kW 2.27 2.72 3.27 4.09 5.45 8.59 10.31 12.37 15.47 20.62 @ 220 - 240 V 28.8 kW 3.03 3.63 4.36 5.45 7.26 11.46 13.75 16.50 20.62 27.49
TEMPRA 36 @ 208 V 27 kW 2.84 3.41 4.09 5.11 6.81 10.74 12.89 15.47 19.33 25.78
@ 220 - 240 V 36 kW 3.78 4.54 5.45 6.81 14.32 17.18 20.62 25.78
Warm water outlet temperature Temperatura del agua caliente Température de sortie d‘eau chaude
Cold water inlet temperature °F °C agua fría temperatura de entrada
Température d‘entrée d‘eau froide 39 50 59 68 77 4 10 15 20 25
TEMPRA 12 @ 208 V 9 kW 0.83 0.97 1.14 1.36 1.70 3.14 3.68 4.30 5.16 6.44 @ 220 - 240 V 12 kW 1.11 1.30 1.51 1.82 2.27 4.19 4.91 5.73 6.87 8.59
TEMPRA 15 @ 208 V 10,8 kW 1,00 1,17 1,36 1,63 2,04 3,77 4,42 5,16 6,19 7,73 @ 220 - 240 V 14,4 kW 1.33 1.56 1.82 2.18 2.72 5.03 5.89 6.87 8.25 10.31
TEMPRA 20 @ 208 V 14.4 kW 1.33 1.56 1.82 2.18 2.72 5.03 5.89 6.87 8.25 10.31 @ 220 - 240 V 19.2 kW 1.77 2.08 2.42 2.91 3.63 6.71 7.86 9.16 11.00 13.75
TEMPRA 22 @ 208 V 16,2 kW 1,49 1,75 2,04 2,45 3,06 5,66 6,63 7,73 9,28 11,60 @ 220 - 240 V 21.6 kW 1.99 2.33 2.72 3.27 4.09 7.54 8.84 10.31 12.37 15.47
TEMPRA 24 @ 208 V 18 kW 1.66 1.95 2.27 2.72 3.41 6.29 7.36 8.59 10.31 12.89 @ 220 - 240 V 24 kW 2.21 2.59 3.03 3.63 4.54 8.38 9.82 11.46 13.75 17.18
TEMPRA 29 @ 208 V 21.6 kW 1.99 2.33 2.72 3.27 4.09 7.54 8.84 10.31 12.37 15.47 @ 220 - 240 V 28.8 kW 2.66 3.11 3.63 4.36 5.45 10.06 11.78 13.75 16.50 20.62
TEMPRA 36 @ 208 V 27 kW 2.49 2.92 3.41 4.09 5.11 9.43 11.05 12.89 15.47 19.33 @ 220 - 240 V 36 kW 3.32 3.89 4.54 5.45 6.81 12.57 14.73 17.18 20.62 25.78
Aumento máximo de temperatura del agua fría entrante Maximum temperature increase above ambient water temperature
GPM
105 °F
l/min
40 °C
113 °F 45 °C
Warm water outlet temperature Temperatura del agua caliente Température de sortie d‘eau chaude
Cold water inlet temperature °F °C agua fría temperatura de entrada
Température d‘entrée d‘eau froide 39 50 59 68 77 4 10 15 20 25
TEMPRA 12 @ 208 V 9 kW 0.71 0.81 0.92 1.06 1.26 2.69 3.07 3.48 4.03 4.77 @ 220 - 240 V 12 kW 0.95 1.08 1.23 1.42 1.68 3.58 4.09 4.64 5.37 6.36
TEMPRA 15 @ 208 V 10,8 kW 0,85 0,97 1,10 1,28 1,51 3,22 3,68 4,18 4,83 5,73 @ 220 - 240 V 14.4 kW 1.14 1.30 1.47 1.70 2.02 4.30 4.91 5.57 6.44 7.64
TEMPRA 20 @ 208 V 14.4 kW 1.14 1.30 1.47 1.70 2.02 4.30 4.91 5.57 6.44 7.64 @ 220 - 240 V 19.2 kW 1.51 1.73 1.96 2.27 2.69 5.73 6.55 7.43 8.59 10.18
TEMPRA 22 @ 208 V 16,2 kW 1,28 1,46 1,66 1,92 2,27 4,83 5,52 6,27 7,25 8,59 @ 220 - 240 V 21.6 kW 1.70 1.95 2.21 2.55 3.03 6.44 7.36 8.36 9.67 11.46
TEMPRA 24 @ 208 V 18 kW 1.42 1.62 1.84 2.13 2.52 5.37 6.14 6.97 8.06 9.55 @ 220 - 240 V 24 kW 1.89 2.16 2.45 2.84 3.36 7.16 8.18 9.29 10.74 12.73
TEMPRA 29 @ 208 V 21.6 kW 1.70 1.95 2.21 2.55 3.03 6.44 7.36 8.36 9.67 11.46 @ 220 - 240 V 28.8 kW 2.27 2.59 2.94 3.41 4.04 8.59 9.82 11.15 12.89 15.27
TEMPRA 36 @ 208 V 27 kW 2.13 2.43 2.76 3.19 3.78 8.06 9.21 10.45 12.08 14.32 @ 220 - 240 V 36 kW 2.84 3.24 3.68 4.26 5.04 10.74 12.27 13.93 16.11 19.09
125.6 °F 52 °C
– 2 –
TEMPRA 12, TEMPRA 15, TEMPRA 20, TEMPRA 24
8
A
TEMPRA 22, TEMPRA 29, TEMPRA 36
8
B
2
7
9
2
7
9
4
6
5
Power
3
°C
4
Power
°C
2
1
26_02_02_0602
Tempra 22, 29, 36
6
(552)
21 /
8
Tempra 12,15, 20, 24
5
(372)
14 /
8
6
5
3
2
1
26_02_02_0603
5
(116)
4/
8
(367)
8
4
14 /
(42)
8
5
1/
3/4”
NPT
Tempra 22, 29, 36
6
(400)
15 /
8
Tempra 22, 29, 36
2
(310)
12 /
8
Power
°C
Tempra 12, 15, 20, 24
5
(220)
8/
8
10
Tempra 12, 15, 20, 24
1
(130)
5/
8
3/4”
NPT
2/
2 (50)
4
(65)
8
4 (102)
8786.02
– 3 –
1
2
2x
C
1
2
3
D
5
12/
(320)
8
a.
2x
b.
a.
2x (Tempra 22, 29, 36=3x)
P o
w e
r
°
C
b.
8789.02
1
(320)
8
5
12/
(22)
8
/
7
(24,5)
19 /
5
(500)
8
2
12/
(310)
8
(295)
8
5
11 /
(47)
8
/
7
1
15 (4x)
26_02_02_0601
15 (4x)
E
1
(320)
8
5
12 /
(22)
8
/
7
(24,5)
19 /
2
(490)
8
(295)
8
5
11 /
(47)
8
/
7
1
8790.02
F
14 13
r
e
w
o
P
C °
14 13
12
11
8788.02
26_02_02_0606
er
w
o
P
C
°
12
11
8787.01
– 4 –
2
TEMPRA 12
1
1
2
3
2
3
1
3
G
12
4
56
3
26_02_02_0599
>
CKT 1
ON
OFF
ON
OFF
H
TEMPRA 15, TEMPRA 20, TEMPRA 24
26_02_02_0600
2
3
220 - 240 V / 208 V AC
CKT 1
CKT 2
56
4
1
L
L
CKT 1
12
4
56
3
>
26_02_02_0608
>
12
4
56
3
ON
OFF
ON
OFF
ON
OFF
ON
OFF
8794.02 8794.02
2
3
I
TEMPRA 22, TEMPRA 29, TEMPRA 36
56
4
1
L
2
3
L
CKT 1 CKT 2
220 - 240 V / 208 V AC
56
4
1
L
L
8793.02
12
4
56
3
12
4
56
3
12
4
56
3
CKT 1
CKT 2
OFF
OFF
OFF
OFF
OFF
OFF
8791.02
ON
ON
ON
ON
ON
ON
8794.02
>
56
2
3
4
1
L
L
CKT 1 CKT 2 CKT 3
220 - 240 V / 208 V AC
>
56
2
3
4
1
L
L
>
56
2
3
4
1
L
L
8792.02
– 5 –
THIS MANUAL MUST BE READ CAREFULLY BEFORE ATTEMPTING TO INSTALL THE TEMPRA
1
2
1
WATER HEATER. IF YOU DO NOT FOLLOW THE SAFETY RULES OR THE INSTRUCTIONS OUTLINED IN THIS MANUAL, THE UNIT MAY NOT OPERATE PROPERLY AND IT COULD CAUSE PROPERTY DAMAGE, SERIOUS BODILY INJURY AND/OR DEATH.
STIEBEL ELTRON, INC. WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OUTLINED IN THIS MANUAL OR BECAUSE OF IMPROPER USE. IMPROPER USE INCLUDES THE USE OF THIS APPLIANCE TO HEAT ANY LIQUID OTHER THAN WATER. FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OR IMPROPER USE VOIDS WARRANTY. NEVER REMOVE THE UNIT’S COVER UNLESS THE ELECTRICITY IS TURNED OFF.
IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OR OPERATION OF THIS WATER HEATER, OR IF YOU NEED AN ADDITIONAL INSTALLATION MANUALS, PLEASE CALL OUR TECHNICAL SERVICE LINE AT 800-582-8423 (USA AND CANADA ONLY). IF YOU ARE CALLING FROM OUTSIDE THE U.S. OR CANADA, PLEASE CALL USA 413-247-3380 AND WE WILL REFER YOU TO A QUALIFIED STIEBEL ELTRON SERVICE REPRESENTATIVE IN YOUR AREA.
Legend to fi gures
1 Temperature adjustment knob 2 Temperature display 3 „Power“ light 4 Hot water connection 5 Cold water connection 6 Wiring block 7 Electronic control unit 8 Safety thermal cut out 9 Heating system 10 Knock-outs for wires 11 Water supply line for faucet installation 12 Sink 13 Cold valve (right) 14 Hot valve (left) 15 Screws and plastic wall anchors
General
The TEMPRA units are designed to supply hot water for a house, apartment or certain com­mercial applications. Unlike a conventional storage type water heater the TEMPRA tan­kless water heater does not store hot water. Instead, water is heated instantaneously as it flows through the unit. The TEMPRA offers greater energy efficiency than storage type water heaters due to the absence of stand-by losses and reduced hot water pipe runs.
The input of heat into the water is controlled electronically. The TEMPRA will deliver any water temperature between 86 ºF (30 ºC) and 125 ºF (52 ºC). Please set the desired temperature using the knob on the front cover. The LED displays the temperature that the unit will produce in °C. Please use the conversion table on the unit in order to obtain degree Fahrenheit. The maximum temperature is electronically limited to 125 °F (52 °C).
Recommended is a setting of 108 °F (42 °C) to 116 °F (47 °C).
In case the “Power” light is flashing while the unit operates, the water flow rate exceeds the heating capacity of the unit. Reduce the hot water flow rate in order to let the unit achieve the set point temperature.
In case you have questions regarding the way you plan to use the TEMPRA, please call our technical service line at 800-582-8423 (USA and Canada). For service outside the U.S. and Canada, please call us at USA 413-247-3380. You can also e-mail us at info@stiebel-eltron-usa.com or fax us at USA 413-247-3369.
One TEMPRA can be used for the following applications.
F
Typical residential installation
F
Typical commercial installation
Mounting the unit
UNIT MUST BE INSTALLED IN A
VERTICAL POSITION WITH THE WATER FITTINGS POINTING DOWN­WARD. DO NOT INSTALL UNIT WHERE IT WOULD ROUTINELY BE SPLASHED WITH WATER. ELECTRIC SHOCK MAY RESULT.
1. Install TEMPRA as close as possible to the main hot water draw-off points.
2. Install TEMPRA in a frost free area. If frost may occur, remove unit before freezing temperatures set in.
3. Leave a minimum of 5“ of clearance on all sides for servicing.
C
– 6 –
.
D
.
4. Remove the cover
5. Mount unit securely to wall by putting four screws through mounting holes
Screws and plastic wall anchors for moun-
ting on masonry or wood are provided.
Water connections
1. All plumbing work must comply with natio­nal and applicable state and local plumbing codes.
2. A pressure reducing valve must be installed if the cold water supply pressure exceeds 150 PSI (10 bar).
3. Make certain that the cold water supply line has been flushed to remove any scale and dirt.
4. An isolating valve of the cold water inlet. This valve allows the unit to be isolated for maintenance pur­poses.
5. The cold water connection (inlet) is on the right side of the unit, and the hot water connection (outlet) is on the left side of the unit.
NOTE: EXCESSIVE HEAT FROM
SOLDERING ON COPPER PIPES NEAR THE TEMPRA MAY CAUSE DAMAGE.
6. Tankless water heaters such as the TEMPRA are not required to be equipped with a Pressure and Temperature Relief Valve (P&T). If the local inspector will not pass the installation without a P&T, it should be installed on the hot water outlet side of the unit.
7. The TEMPRA is designed for connection to copper tubing, PEX tubing or a braided stainless steel hose with a 3/4“ NPT female tapered thread. If soldering near the unit is necessary, please direct the flame away from the housing of the unit in order to avoid damage.
8. When all plumbing work is completed, check for leaks and take corrective action before proceeding.
E
is an integral part
Loading...
+ 14 hidden pages