Stiebel Eltron MHG, MHJ, MHS, MHD, MHR User guide

...
Page 1
Technik zum Wohlfühlen
MHG; MHJ; MHS; MHD; MHR; SPH komfotherm
Deutsch
Natursteinheizung Gebrauchs- und Montageanweisung
English
Natural stone heating Operation and installation instructions
Radiateur à Pierre Naturelle Notice d’utilisation et de montage
Nederlands
Natuur steen verwarming Gebruiks- en installatieaanwijzing
7829.01
167102
Page 2
Inhaltsverzeichnis
Deutsch Seite 4 - 7
1. Gebrauchsanweisung 4
1.1 Gerätebeschreibung
1.2 Bedienung
1.3 Sicherheitshinweise
1.4 Pflege und Wartung
1.5 Was tun wenn ...?
1.6 Wichtiger Hinweis
2.Montageanweisung 4
2.1 Geräteaufbau
2.2 Vor schriften und Bestimmungen
2.3 Montageort
2.4 Gerätemontage
2.5 Erstinbetriebnahme
2.6 Übergabe
2.7 Sonderzubehör Technische Daten
Umwelt und Recycling 6 Kundendienst und Garantie 6
Table of contents
English page 8 - 9
1. Operation instructions 8
1.1 Unit description
1.2 Operation
1.3 Safety guidance
1.4 Care and maintenance
1.5 What shall i do if ...?
1.6 Important note
2. Installation instructions 8
2.1 Unit construction
2.2 Provisions and regulations
2.3 Installtion location
2.4 Installtion of the unit
2.5 First start-up
2.6 Handover
2.7 Special accessoriers Technical data
Environment and recycling 9 Guarantee 9
Contenu
Français page 10 - 11
1. Notice d’utilisation 10
1.1 Description de l’appareil
1.2 Commande
1.3 Règles de sécurité
1.4 Entretien et maintenance
1.5 Que faire, si ...?
1.6 Remarque importante
2.Notice de montage 10
2.1 Composition de l’appareil
2.2 Prescriptions et dispositions réglementaires
2.3 Lieu de montage
2.4 Montage de l’appareil
2.5 Première mise en service
2.6 Remise
2.7 Accessoires spéciaux
Caractéristiques techniques
Environnement et recyclage 11 Garantie 11
Inhoudsoverzicht
Nederlands bladzijde 12 - 13
1. Gebruiksaanwijzing 12
1.1 Beschrijving van het toestel
1.2 Bediening
1.3 Veiligheidsvoorschriften
1.4 Onderhoud en reiniging
1.5 Wat te doen indien ...?
1.6 Belangrijke aanwijzing
2. Montageaanwijzing 12
2.1 Opbouw van het toestel
2.2 Voorschriften en bepalingen
2.3 Plaats van montage
2.4 Montage van het toestel
2.5 Eerste ingebruikneming
2.6 Overdracht
2.7 Speciale accessoires
Technische gegevens
Milieu en recycling 13 Garantie 13
2
Page 3
100
mm
300
300
mm
100
L N
PE
100 mm
4/N 4/N 2/LE 6/L
100 mm
m
m
m
m
RTA-S
100 mm
100 mm
100 mm
MHG; MHJ; MHS; MHD; MHR; SPH
8675.01
500 mm
7834.02
632
8676.01
L N
PE
< 1500 W
4/N 4/N 2/LE 1/L
> 1500 W
MHG; MHJ; MHS; MHD; MHR; SPH
5
7922.02
4
B
RTA 3000
70
8677.01
a
40
b
35
H
230 V
7
1
7831.03
3
Page 4
1. Operation instructions for the user and the professional
1.1 Unit description
The natural stone heating unit is an electrical­ly heated marble or soapstone slab, which is controlled via a wall-mounted room thermo­stat.
For this, a heating conductor is let into the back of a high-grade 30 mm thick natural stone slab (1), this serves to heat the slab uniformly.
The heat stored in the natural stone slab is given off in the form of long-wave rays (com­parable with the sun’s rays) and thus warms the people and objects located within the room equally, without causing air turbulence. Unwanted radiation towards the rear is pre­vented by a 4 mm thick large-surface insula­ting board on the rear of the slab.
By using special dowels to secure the wall mountings (2) to the natural stone slab, the securing points are not visible from the front, which means that the structure of the slab is not interrupted. The wall mountings can be changed round in such a way that the natural stone heating unit can be installed both hori­zontally and vertically.
1.2 Operation
The natural stone heating unit is controlled exclusively by wall mounted room thermos-
tats (surface or concealed mounting). The operating and installation instructions of the respective control unit are to be obser ved in this process.
1.3 Safety guidance
The installation (electrical installation), as well as the first start-up and maintenance of this unit, may only be carried out by a registered qualified installer in accordance with these instructions.
Under no circumstances must the unit be operated if work such as the laying, san­ding, sealing, cleaning with petrol and care of floors (spr ay, floor wax) and the like is being carried out.
During operation the surface of the natur al stone will be hot (approx. 80°C). Danger
of burning !
Keep children away from heater!
No objects must be placed on the unit, leaned against it, or placed between the heating unit and the wall (e.g. to dry was­hing). Moreover, no flammable, ignitable or heat insulating objects or materials such as washing, blankets, magazines, containers of floor wax or petrol, spray cans and the like, must be placed in the immediate vicinity of the unit. Danger of fire!
For objects of all kinds, such as for example furniture, drapes, curtains and textiles or
other flammable or non-flammable materi­als, a minimum distance of 100 mm from all sides of the unit, and 500 mm from the front of the unit, must be adhered to.
1.4 Care and maintenance
A moist cloth is sufficient for care and clea­ning of the natural stone heating unit in the cooled down state. Abrasive and corrosive cleaning products are to be avoided.
1.5 What shall I do if.......?
If the natural stone heating unit fails to warm up, check whether the relevant fuses in the fuse box or the fault-current circuit breaker have cut out. Rectify the cause!
If the cause cannot be rectified, the qualified installer must be informed.
1.6 Important note
Keep these instructions carefully, and
hand them to your successor in the event of a change in ownership. In the event of any repair work, pass them to the qualified installer for his inspection.
2. Installation instructions for the professional
Installation, electrical connection, and first start-up must be carried out by a qualified installer who is registered by the appropriate electricity supply company, under observance of these installation instructions.
2.1 Unit construction
1 Natural stone slab 2 Wall mountings 3 Insulating board 4 Mains connection cable 5 Spacer bolts 6 Wall mounting securing screw 7 Hexagonal screw
A channel system is cut into the back of the natural stone slab, into which a heating con­ductor with two automatic-reset safety ther­mal cut-out is inserted. To cover this over, the channel system is final­ly filled with marble bonding cement and an insulating board is bonded over it.
2.2 Pro visions and r egulations
The unit may only be fitted on a vertical wall which is temperature resistant to at least 90°C.
8
Minimum distances to the surfaces of adja­cent objects must be adhered to.
The unit rating plate is to be noted. The stated voltage must correspond to the mains voltage.
All electrical connection and installation work is to be carried out in accordance with the VDE (Association of Ger man Electrical Engineers) regulations (DIN VDE 0100 T520 A3), the provisions of the ap­propriate electricity supply companies, and the relevant national and regional provisi­ons.
Connection to the mains network is only possible in the form of a fixed connection.
The unit must not be fitted directly bene­ath a wall electrical socket.
It must be possible to isolate the unit from the mains network on all poles with an isolating distance of at least 3 mm. Installa­tion using a permanently laid connection lead is not permissible.
If the heating unit is installed in rooms with a bath and/or a shower, the protection zone according to VDE 0100 Part 701, in conformity with the information on the unit rating plate, is to be taken into account.
The unit is to be fitted in such a way that switching and control devices cannot be touched by anyone in the bath or under the shower.
The supply equipment is to be rated in ac­cordance with the rated input of the unit.
Installation of the connection box in rooms with a bath and/or shower not in protec­tion zones 1 and 2.
2.3 Installation location
The natural stone heating unit is designed exclusively for fixed wall mounting. In this re­gard, care is to be taken to ensure that a wall with a sufficient load bearing capacity is avai­lable.
Installation is possible in all rooms, in ba­throoms the natural stone heating unit can be installed in protection zone 2.
2.4 Installation of the unit
The unit is set up at the factory for horizon­tal installation.
In the event of vertical installation of the na­tural stone heating unit, the following changes
Page 5
are to be made prior to starting the installati­on: the wall mounting (2) lying above the
mains connection lead must be exchanged with the spacer bolt lying diagonally(5).
Care is to be taken to ensure that the mains connection cable is always
located at the bottom edge;
rotate both wall mountings with the slotted hole openings to face downwards.
Tighten the securing screws (6) in
the natural stone heating unit care­fully, as the dowels in the natural stone slab can otherwise be turned excessively.
2.4.1 Securing on the wall
The natural stone heating unit must
only be secured to a level wall, since cracks can otherwise occur in the natural stone slab as the result of stresses. In the event of any unevenness, the surface must be levelled prior to tightening the se­curing screws.
Measure out dimensions a and b for the
drilled holes, on the natural stone heating unit.
Drill holes, based on the noted dimensi-
ons, in a wall with a sufficient load-bearing capacity, taking care to ensure that a safety distance of 100 mm on all sides is adhe­red to (e.g. dimension b + 100 mm).
Screw the hexagonal screws (7) into the
drilled holes up to the point at which the natural stone heating unit with the open slotted holes in its wall mountings (2) can still be hooked on behind the screw head.
Hang the natural stone heating unit (do
not allow to topple or tilt - danger of bre­akage) and tighten up the hexagonal screws. In this process, take care to ensure that any stresses which occur are com­pensated for by slightly loosening the se­curing screws (6) in the natural stone slab. These should subsequently be retightened up to the stop point (overtightening can cause dowels to become loose).
2.4.2 Electrical connection
Connect the natural stone heating unit only to a 230 V 50 Hz alternating current supply.
If the mains connection lead is shortened, take care to ensure that the natural stone heating unit can be taken off again, even wit­hout disconnecting the connection lead.
2.5 First start-up
When the natural stone heating unit
is heated up for the first time, a hea­ting-up time of 20 minutes should not be exceeded. The slab must then cool down for at least 60 minutes. This measure is to be repeated one further time.
In the first two days, the heating should be built up to the desired room temperature in stages. This avoids hairline cracks developing. If hairline cracks should nevertheless develop, this is not dangerous and impairs neither the functioning nor the safety of the natural stone heating unit.
2.6 Handov er
Explain the functions of the unit to the user. Draw his or her attention to the safety in­structions, in particular. Hand the operating and installation instructions to the user.
2.7 Special accessories
Control of the natural stone heating unit is effected using the room thermostat.
RTA-S: Room thermostat with thermal feed­back, switching capacity 10A 250V.
RTA 3000: as RTA-S but without switch and a switching capacity of 3000 W.
In the event of a heating capacity of
more than 1500 W, the neutral con­ductor (N) is to be routed directly to the mains terminal, do not connect to the con­trol unit.
RTU-S: Room thermostat with built-in syn-
chronous timer (24 hr.) for automatic tempe­rature reduction.
3. Envir onment and recycling
Please help us to protect the environment by disposing of the packaging in accordance with the national regulations for waste processing.
4. Guarantree
For guarantees please refer to the respective terms and conditions of supply for your country.
The installation, electrical connection
and first operation of this appliance should be carried out by a qualified installer.
The company does not accept liability for failure of any goods supplied which are not installed in accordance with the manufacturer's instructions.
English
Technical data
Type MHG 55 MHG 90 MHG 120 MHG 140
MHJ 55 MHJ 90 MHJ 120 MHJ 140
MHS 55 MHS 90 MHS 120 MHS 140
MHD 55 MHD 90 MHD 120 MHD 140
MHR 55 MHR 90 MHR 120 MHR 140
SPH 55 SPH 90 SPH 120 SPH 140
Rated power W 550 900 1200 1400
Rated voltage 1/N ~ 230 V 50 Hz Dimensions H x W x D mm 500 x 750 x 30 500 x 1000 x 30 500 x 1230 x 30 550 x 1230 x 30 Weight kg approx. 30 approx. 40 approx. 55 approx. 60 Mains connection Connection lead approx. 100 cm; permanent connection Protection class II Protection mode IP 25, water jet protection
9
Page 6
Technik zum Wohlfühlen
Adressen und Kontakte www.stiebel-eltron.com
Zentrale Holzminden Stiebel Eltron GmbH & Co. KG
Dr.-Stiebel-Str. 37603 Holzminden Telefon 05531 / 702-0 Fax Zentrale 0 5 531 / 7 02-4 80 E-Mail info@stiebel-eltron.com Internet www.stiebel-eltron.com
Stiebel Eltron International GmbH
Dr.-Stiebel-Str. 37603 Holzminden Telefon 05531 / 702-0 Fax 05531/7 02-479 E-Mail info@stiebel-eltron.com Internet www.stiebel-eltron.com
Unseren zentralen Service erreichen Sie unter 0 180 3...
... in der Zeit von:
Montag bis Donnerstag 715 bis 1800 Uhr Freitag 715 bis 1700 Uhr
Info-Center
allgemeine Information und technische Auskunft
Telefon 0 180 3 - 70 20 10
Telefax 0 180 3 / 70 20 15 E-Mail: info-center@stiebel-eltron.com
Kundendienst
Telefon 0 180 3 - 70 20 20
Telefax 0 180 3 / 70 20 25 E-Mail: kundendienst@stiebel-eltron.com
Ersatzteil-Verkauf
Telefon 0 180 3 - 70 20 30
Telefax 0 180 3 / 70 20 35 E-Mail: ersatzteile@stiebel-eltron.com
0,09 /min (Stand: 3/04)
Gedruckt auf
100% Recycling-Papier.
Aktiv im Umweltschutz.
7938
Stiebel Eltron Vertriebszentren
Dortmund
Oespel (Indupark) Brennaborstr. 19 44149 Dortmund Telefon 0231/ 9650 22-10 E-Mail: dortmund@stiebel-eltron.com
Frankfurt
Rudolf-Diesel-Str. 18 65760 Eschborn Telefon 0617 3 /6 02-10 E-Mail: frankfurt@stiebel-eltron.com
Hamburg
Georg-Heyken-Straße 4a 21147 Hamburg Telefon 040/ 752018-10 E-Mail: hamburg@stiebel-eltron.com
Holzminden/Info-Center Berlin/Hannover/Nürnberg
Dr.Stiebel-Straße 37603 Holzminden Telefon 0 1803 / 70 20 10 E-Mail: info-center@stiebel-eltron.com
Köln
Ossendorf (Butzweiler Hof) Mathias-Brüggen-Str. 132 50829 Köln Telefon 0221 /59 7 71-10 E-Mail: koeln@stiebel-eltron.com
Leipzig
Airport Gewerbepark/Glesien Ikarusstr. 10 04435 Schkeuditz-Glesien Telefon 03 42 07/755-10 E-Mail: leipzig@stiebel-eltron.com
München
Hainbuchenring 4 82061 Neuried Telefon 0 89/89 9156-10 E-Mail: muenchen@stiebel-eltron.com
Stuttgart
Weilimdorf Motorstr. 39 70499 Stuttgart Telefon 07 11/9 8867-10 E-Mail: stuttgart@stiebel-eltron.com
Tochtergesellschaften und Vertriebs­zentren Europa und Übersee
Belgique
Stiebel Eltron Sprl /Pvba Rue Mitoyenne 897 B-4840 Welkenraedt
087-88 14 65 Fax 087-88 15 97 E-Mail stiebel@skynet.be Internet www.stiebel-eltron.com
∨∨
∨∨
C
eská republika
Stiebel Eltron spol. s r.o.
oo
o
oo
K Háju
m 946 C
∨∨
∨∨
Z-15500 Praha 5-Stodulky
2-511 16 111 Fax 2-355 1 2 122 E-Mail info@stiebel-eltron.cz Internet www.stiebel-eltron.cz
France
Stiebel Eltron S.A.S. 7-9, rue des Selliers B.P. 85107 F-57073 Metz-Cédex
03-87-74 38 88 Fax 03-87-74 68 26 E-Mail secretcom@stiebel-eltron.fr Internet www.stiebel-eltron.fr
Great Britain
Stiebel Eltron Ltd. Lyveden Road Brackmills GB-Northampton NN47ED
016 04-76 64 21 Fax 016 04-76 52 83 E-Mail info@stiebel-eltron.co.uk Internet www.stiebel-eltron.co.uk
Magyarország
Stiebel Eltron Kft. Pacsirtamezo´´u.41 H-1036 Budapest
012 50-60 55 Fax 013 68-80 97 E-Mail info@stiebel-eltron.hu Internet www.stiebel-eltron.hu
Nederland
Stiebel Eltron Nederland B.V. Daviottenweg 36 Postbus 2020 NL-5202 CA's-Hertogenbosch
073-6 23 00 00 Fax 073-6 23 11 4 1 E-Mail stiebel@stiebel-eltron.nl Internet www.stiebel-eltron.nl
Österreich
Stiebel Eltron Ges.m.b.H. Eferdinger Str. 73 A-4600 Wels
072 42-4 73 67-0 Fax 072 42-4 73 67-42 E-Mail info@stiebel-eltron.at Internet www.stiebel-eltron.at
Polska
Stiebel Eltron sp.z. o.o ul. Instalatorów 9 PL-02-237 Warszawa
022-8 46 48 20 Fax 022-846 67 03 E-Mail stiebel@stiebel-eltron.com.pl Internet www.stiebel-eltron.com.pl
Sverige
Stiebel Eltron AB Box 206 SE-641 22 Katrineholm
0150-48 7900 Fax 0150-48 7901 E-Mail info@stiebel-eltron.se Internet www.stiebel-eltron.se
Schweiz
Stiebel Eltron AG Netzibodenstr. 23 c CH-4133 Pratteln
061-8 16 93 33 Fax 061-8 16 93 44 E-Mail info@stiebel-eltron.ch Internet www.stiebel-eltron.com
Thailand
Stiebel Eltron Ltd. 469 Building 77, Bond Street Tambon Bangpood Ampur Pakkred Nonthaburi 11120
02-960 1602-4 Fax 02-960 1605 E-Mail stiebel@loxinfo.co.th Internet www.stiebeleltronasia.com
USA
Stiebel Eltron Inc. 242 Suffolk Street Holyoke MA 01040
04 13-5 38-78 50 Fax 04 13-5 38-85 55 E-Mail info@stiebel-eltron-usa.com Internet www.stiebel-eltron-usa.com
CAP 167102/33654/3/7955 · Roll · Änderungen vorbehalten· These instructions are subject to alteration notice! · Sous réserve de modifications! · Wijzigingen voorbehouden!