STIEBEL ELTRON MEGABOOST Operation And Installation

OPERATION AND INSTALLATION
TANKLESS ELECTRIC BOOSTER FOR TANK WATER HEATERS
»MEGABOOST
Max. power, below set temp.
Modulating power
86°F - 105°F Hand Washing 105°F - 120°F Residential Use 120°F - 140°F Commercial Only
F
C
Tankless electric booster
for tank water heaters
Off
The MegaBoost is tested and certifi ed by WQA against NSF/ ANSI 372 for lead free compliance.
STIEBEL ELTRON, Inc.
17 West Street | West Hat fi eld, MA 01088 Tel. 413-247-3380 | Fax 413-247-3369 Email info@stiebel-eltron-usa.com www.stiebel-eltron-usa.com
2 | DHC-E WWW.STIEBEL-ELTRON-USA.COM
CONTENTS | OPERATION
OPERATION
1. General information ___________________________________________ 2
1.1 Safety information __________________________________________________ 2
1.2 Other symbols in this document _________________________________ 2
2. Safety ____________________________________________________________ 3
2.1 Intended use _________________________________________________________ 3
2.2 General Information________________________________________________ 3
2.3 Safety Precautions __________________________________________________ 3
3. Register your product _________________________________________ 3
4. General __________________________________________________________ 4
5. Troubleshooting ________________________________________________ 4
INSTALLATION
6. Safety ____________________________________________________________ 5
6.1 General safety instructions _______________________________________ 5
7. Appliance description _________________________________________ 5
7.1 Standard delivery ___________________________________________________ 5
8. Mounting the appliance _______________________________________ 5
8.1 Application ___________________________________________________________ 5
8.2 Choosing installation confi guration _____________________________ 5
8.3 Typical installation confi gurations ______________________________ 5
8.4 Mounting _____________________________________________________________ 6
9. Water connections _____________________________________________ 6
10. Electrical connection ___________________________________________ 6
10.1 Temperature setting/anti-scalding protection _______________ 7
10.2 Terminal block _______________________________________________________ 7
11. Commissioning _________________________________________________ 8
11.1 Appliance handover ________________________________________________ 8
12. Troubleshooting ________________________________________________ 8
12.1 Display options LED diagnostic „traffi c lights“ ________________ 8
12.2 Fault table ____________________________________________________________ 8
13. Normal maintenance ___________________________________________ 8
14. Technical Data __________________________________________________ 9
14.1 Dimensions ___________________________________________________________ 9
14.2 Wiring diagram _____________________________________________________ 9
14.3 Data table ____________________________________________________________ 9
14.4 Spare parts__________________________________________________________10
15. Warranty _______________________________________________________ 11
OPERATION
1. General information
Note
Read these instructions carefully before using the applian­ce and familiarize yourself with its functions. Keep these instructions safe. Pass on the instructions to a new user if required.
1.1 Safety information
1.1.1 Structure of safety information
KEYWORD: Type of risk Here, possible consequences are listed that may result from not observing the safety information.
 Steps to prevent the risk are listed.
1.1.2 Symbols. type of risk
Symbol Type of risk
!
Injury
Electrocution
Burns or scalding
1.2 Other symbols in this document
Note
Notes are bordered by horizontal lines above and below the text. General information is identifi ed by the symbol shown on the left.
 Read these notes carefully.
Symbol
!
Damage to the appliance and environment
Appliance disposal
 This symbol indicates that you have to do something. The ac-
tion you need to take is described step by step.
OPERATION
SAFETY
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM DHC-E | 3
2. Safety
Observe the following safety information and regulations.
Operate the appliance only when fully installed and with all safety equipment fi tted.
2.1 Intended use
The appliance is intended to boost domestic hot water output of a tank water heater.
Any other use beyond that described shall be deemed inappropriate.
Observation of these instructions is also part of the correct use of this appliance.
2.2 General Information
Read this entire manual. Failure to follow all the guides, instructions and rules could cause personal injury or property damage. Improper installation, adjustment, alteration, service and use of this appliance can result in serious injury.
This appliance must be installed by a licensed electrician and plumb­er. The installation must comply with all national, state and local plumbing and electric codes. Proper installation is the responsibility of the installer. Failure to comply with the installation and operating instructions or improper use voids the warranty.
Save these instructions for future reference. Installer should leave these instructions with the consumer.
If you have any questions regarding the installation, use or opera­tion of this water heater, or if you need any additional installation manuals, please call our technical service line, see last side.
2.3 Safety Precautions
!
DANGER: Injury Please read and follow these instructions. Failure to follow these instructions could result in serioius personal injury or death.
!
Damage to the appliance and the environment
The appliance must be installed by a licensed electrician and plumber. The installation must comply with all national, state and local plumbing and electric codes. Service of the appliance must be performed by qualifi ed service technicians.
DANGER: Electrocution Before proceeding with any installation, adjustment. al­teration, or service of this appliance all circuit breakers and disconnect switches servicing the appliance must be turne d of f. Failure to do so could result in serious personal injury or death.
DANGER: Electrocution Never remove the appliance cover unless the electricity servicing the appliance is turned off. Failure to do so could result in personal injury or death.
DANGER: Electrocution The appliance must be properly grounded. Failure to elec­trically ground the product could result in serious personal injury or death.
DANGER: Burns Water temperatures over 125°F (52°C)can cause severe burns instantly or death from scalding. A hot water scal­ding potential exists if the thermostat on the appliance is set too high. Households with small children, disabled or elderly persons may require that the thermostat be set at 113°F (45°C) or lower to prevent possible injury from hot water.
!
WARNING: Injury Where children or persons with limited physical, sensory or mental capabilities are to be allowed to control this appliance, ensure that this will only happen under super­vision or after appropriate instructions by a person res­ponsible for their safety. Children should be supervised to ensure that they never play with the appliance.
3. Register your product
YOU MUST REGISTER THIS PRODUCT WITHIN 90 DAYS OF PURCHASE ON OUR WEB SITE IN ORDER TO ACTIVATE THE STANDARD
WARRANTY OR TO BE ELIGIBLE FOR THE EXTENDED WARRANTY. GO TO OUR WEB SITE AT WWW.STIEBEL-ELTRON-USA.COM AND CLICK ON REGISTER YOUR PRODUCT.
Before beginning the registration process, we suggest that you gather the necessary information which will be as follows:
Number listed after “Nr.” Place of Purchase Purchase Date First & Last Name Email address Physical Address Phone Number Installation Date
IF YOU HAVE ANY QUESTIONS CONCERNING THE REGISTRATION PROCESS OR WARRANTY OPTIONS, PLEASE CONTACT STIEBEL ELTRON USA DIRECTLY AT (800)-582-8423.
OPERATION
GENERAL
4 | DHC-E WWW.STIEBEL-ELTRON-USA.COM
4. General
The tankless water heater differs from conventional storage type water heaters in several ways. It does not store hot water. Instead, water is heated instantaneously as it fl ows through the appliance. Due to the absence of stand-by losses, the appliance offers greater energy effi ciency than storage type water heaters.
The MegaBoost should be installed in conjunction with a storage tank water heater.
MegaBoost can be installed on the cold water inlet or on the hot water outlet of the tank water heater. Installation at either location will greatly increase the amount of hot water the tank is able to de­liver (fi rst hour rating). Either installation location will also shorten the recovery time necessary for the tank to recharge, but this effect is far greater with installation on the cold water inlet.
°
F
°
C
26_02_02_1086
The input of heat into the water is electronically controlled. The appliance will deliver any water temperature between 86°F (30°C) and 140°F (60°C). Please set the desired temperature using the knob on the front cover.
Note:
For reasons of appliance effi ciency and durability (scaling), the optimum temperature setting lies between 86°F (30°C) and 120°F (50°C).
In case the “Power” light is fl ashing while the appliance operates, the water fl ow rate exceeds the heating capacity of the appliance. Reduce the hot water fl ow rate in order to let the appliance achieve the set point temperature. The maximum temperature is electroni­cally limited to 140°F (60°C). In case you have questions regarding the way you plan to use the appliance, please call our technical service line, see last side.
5. Troubleshooting
Symptom Possible Cause Solut ion
No hot water not enough flow rate
to activate appliance
clean faucet aerator or shower head
Water not hot enough
water flow too high reduce water flow rate until light on
front cover stops blinking
If you cannot remedy the fault, notify the contractor who installed the appliance. To facilitate and speed up your enquiry, please pro­vide the serial number from the type plate (000000-0000-000000).
Loading...