7 0 1 1 0 0 #5 FAST
8 1 1 1 0 0 #2 MEDIUM
9 0 0 0 1 0 #5 MEDIUM
10 1 0 0 1 0 SWOOP MEDIUM
11 0 1 0 1 0 #3 MEDIUM
12 1 1 0 1 0 BUZZ TONE
13 0 0 1 1 0 STEADY FAST
14 1 0 1 1 0 SWOOP SLOW
15 0 1 1 1 0 CONTINUOUS
16 1 1 1 1 0 FAST REPEAT
STEP 3 - A
STEP 4 - T
LARM TIMING AND VOLUME - S2
ERMINAL STRIP CONNECTIONS
WIRES TO SIREN
1 2 3 4 5
17 0 0 0 01 STANDARD ALARM
18 1 0 0 0 1 #3 FAST
19 0 1 0 0 1 #5 SLOW
20 1 1 0 0 1 FAST BEEP
21 0 0 1 0 1 SOUND A
22 1 0 1 0 1 SOUND B
23 0 1 1 0 1 SOUND C
24 1 1 1 0 1 SOUND D
25 0 0 0 1 1 SOUND D LOUD
26 1 0 0 1 1 SOUND E
27 0 1 0 1 1 SOUND F
28 1 1 0 1 1 SOUND G
29 0 0 1 1 1 SOUND H
30 1 0 1 1 1 #4 LOW
31 0 1 1 1 1 SOUND K
32 1 1 1 1 1 CONTINUOUS FAST
NOTE: Sound may be disabled by clipping wires to
the siren. THIS WILL VOID ALL WARRANTIES.
Remove two screws on circuit board; leave
enough length of wire to possibly reattach in
the future. Then insulate wires to prevent
shorting to electronic components.
ALARM
TIMING
15 seconds 1 1 1 1 High
*
30 seconds 1 0 1 0 1
1 2
STROBESIREN
3 45
VOLUME
60 seconds 0 1 0 1 Low
Continuous 0 0 0 0 0
1 = ON0 = OFF
*Factory default settings
**Shipped with jumper
wire installed. Remove
to add key switch or
other main power
on/off switch.
NOTE: “DC IN” are the
only polarity
5
sensitive terminals.
When external
power is used,
battery will act as
a backup. “Dry
Contacts: NC, COM,
NO” are used for
remote alarm
monitoring.
Page 6
D
RILL (4) 3/16 in. DIA. HOLES IF USING #8-10 ANCHORS.
DRILL (4) 3/32 in. DIA. HOLES WHEN USING #6 SCREWS ONLY.
19018 ANCHOR
#
8-10
(4) PROVIDED
SUB-71100A-W
19039 SCREW
#6 x 1 1/4 in.
(4) PROVIDED
19060 SCREW
#
6-32 x 1 in.
(2) PROVIDED
BASE PLATE
STEP 5 - MOUNTING OPTIONS
DRILL
3-/16 DIA HOLES
19018 ANCHOR
#8-10
(2) PROVIDED
19039 SCREW
#6 x 1 1/4 in.
(2) PROVIDED
BASE PLATE
18074 SWITCH LOCK
SUB-SA505 KEY SWITCH
MOUNTING BRACKET
3 9/32 in.
18075 REPLACEMENT
#801 KEY
ENCLOSURE
ROUTE THE TWO KEY
SWITCH WIRES THROUGH
THE HOLE AS SHOWN
WIRE ACCESS HOLE
ROUTE THE TWO REED
SWITCH WIRES FROM
CABINET THROUGH THE
HOLE AS SHOWN
A) TO STI BACKBOX SUB-71100A-W
1. Using 5/32 drill, drill through the (4) existing holes in back box (one in each corner).
2. Place back box on wall and mark the mounting hole positions.
3. If using #8-10 anchors, drill 3/16 dia. holes 1 in. deep into wall and press anchor into hole.
If using #6 screws only, drill 3/32 dia. holes 1 ¼ in. deep.
4. Mount back box to wall using #6 x 1 ¼ in. screws.
5. Mount base plate as shown using (2) #6-32 x 1 in. screws.
NOTE: If not using STI back box, make sure surface will depress tamper switch.
O KEY MOUNT PLATE OR INTO WALL WITHOUT ELECTRICAL BOX
B) T
NOTE: For bare wall installation, wire access hole may need to be drilled.
6
Page 7
S
INGLE GANG
ELECTRICAL BOX
19062 SCREW
#6-32 x 1 1/2 in.
(2) PROVIDED
BASE PLATE
05050- LENS COLORS
A - AMBER
B - BLUE
G - GREEN
R - RED
W - WHITE
19002 SCREW
#8-32 x 3/8 in.
(4) PROVIDED
05000 ELECTRONICS
INSTALLED
BASE PLATE
WIRE ACCESS HOLE
19016 TAMPER-PROOF
TOOL (1) PROVIDED
19011 TAMPER-PROOF
SCREW
ROUTE WIRES
THRU HOLE
C) TO SINGLE GANG ELECTRICAL BOX
STEP 6 - ELECTRONICS FINAL ASSEMBLY
Wiring: After mounting circuit board assembly, connect wires. Refer to terminal strip connections (step 4).
Lens installation: Slide lip of lens behind circuit board mounting plate. Rotate lens into position. Secure with
tamperproof screw and special wrench.
7
Page 8
STEP 7 - OPERATION
• Turn key switch on to arm.
• Cycle key switch to reset alarm.
• Alarm will sound when cover is removed, unit is removed from the wall or
cabinet is opened (alarm switch is electronically closed).