STI STI-6400, STI-6403, STI-6404, STI-6402, STI-6405 Instruction Manual

STI-6400 Exit Stopper
®
INSTRUCTION MANUAL
“We Protect The Things That Protect You.”
Safety Technology International, Inc.
Features:
• Helps prevent both unauthorized exits and entries through emergency exit doors.
• Easy to install.
• Less expensive than heavy horizontal bar type units and practical for all emergency doors.
• May be mounted on top, right, left or next to almost any door.
• User can select onsite whether to use an alarm or annunciator.
• Contact STI for custom applications .
2
TABLE OF CONTENTS
WARNINGS
All units are recommended for indoor use. Unit must be tested periodically to verify the life of battery. STI recommends you change the 9 Volt battery twice a year. Installer may need to purchase a simple audio-meter, typically available at your local electronics store, to measure the sound in areas where the alarm is expected to be heard during normal noise environment. Results from this test may prove it beneficial to purchase additional exit stopper units. When purchasing a remote unit (STI-6403) you will need to periodically test the connections to make sure audibles function at a sound level to alert staff. Maximum of three STI-6403 may be used in parallel.
All specifications and information shown are current as of publication and subject to change without notice.
• Warnings and Cautions ................................................................................................Page 2
• Warranty Information ..................................................................................................Page 2
• Specifications ................................................................................................................Page 3
1. Dimensions ..............................................................................................................Page 3
2. Polycarbonate ..........................................................................................................Page 3
3. Electronics ................................................................................................................Page 3
4. Remote Horn ............................................................................................................Page 3
• Circuit Board Set-Up......................................................................................................Page 4
• Terminal Strip Layout....................................................................................................Page 4
• Switch Settings..............................................................................................................Page 4
• Alarm Feature Description............................................................................................Page 5
• Installation Instructions All Units / STI-6400 ..............................................................Page 5
• Mounting Options ........................................................................................................Page 6
• STI-6402 Double Door additional install notes ........................................................Page 7
• STI-6403 Remote Horn additional install notes ......................................................Page 7
• STI-6404 Double Door with Remote Horn additional install notes ........................Page 7
• STI-6405 Exit Stopper with Momentary Reset ........................................................Page 7
WARRANTY INFORMATION
Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components).
3
SPECIFICATIONS
Polycarbonate Enclosure:
Dimensions 5.375” W x 5.375” H x 2 “ D (137mm x 137mm x 51mm)
Flammability: UL94 V-2
Wall Thickness: 0.12 in (3.05mm)
Electronics: STI-6400 - All Units
9 VDC Alkaline or 9V-24VDC wired
Class II UL Listed transformer
Horn Volume at 1 ft. 95 dB low / 105 dB high
Relay Output Form C Dry Contacts 0-30 VDC or VAC, 1 Amp
Stand by Current 10uA
Alarm Current 130mA at 95 dB / 200mA at 105 dB
Electronics: STI-6403 and STI-6404 - Remote Horn Unit
Power Source 9 VDC Operating Power* only
Horn Volume at 1 ft. 95 dB low / 105 dB high
Stand by Current 0 A
Alarm Current 50mA at 95 dB/ 200 mA at 105 dB
*Power source for the STI-6403 Remote Horn uses a separate power source from the STI-6400
alarm. The Remote Horn contains an internal 9 volt battery. Horn operates when the Form C contact at main unit is activated on alarm.