STI 7535 User Manual

Page 1
Protective Cabinet
STI-7534, STI-7535 and STI-7535AED
Features
Clear, protective polycarbonate cover with siren/strobe alarm.
Design allows visibility at any angle.
Complete with mounting hardware and gasket.
Includes wire shelf, backing plate and siren/strobe alarm — AED models
External mounting tabs or internal drill dimples.
enamel finish.
Siren/strobe alarm lens is red. Also available with amber, green, blue or white lens.
Siren offers 32 user selectable tones.
Alarm can be set for a piercing 100 dB or 85 dB.
Independent strobe and siren timing of 15 seconds, 30 seconds, 60 seconds or
continuous.
Powered by a 9 VDC battery or external 12-30 volts.
Low battery indicator.
We protect the things that protect you.
Page 2
CONTENTS
Warnings ..................................................................................................page 2
Cleaning Instructions ..............................................................................page 2
Dimensions ..............................................................................................page 3
Specifications ..........................................................................................page 3
Installation of Cabinet ............................................................................page 4
Installation of Alarm ................................................................................page 4
Alarm Electronic Setup ............................................................................page 5
Alarm Tones ............................................................................................page 5
Alarm Timing and Volume ......................................................................page 5
Alarm Terminal Strip Connections ..........................................................page 6
Alarm Electronics Assembly ....................................................................page 6
Assembly Parts List ................................................................................page 7
Operation ................................................................................................page 7
Warranty ..................................................................................................page 7
Accessories & Replacement Parts............................................................page 8
WARNINGS
All units are recommended for indoor use. Unit must be tested periodically to verify the life of battery. STI recommends you change the 9 Volt battery twice a year. When purchasing a siren/strobe alarm, you will need to periodically test the connections to make sure audibles function at a sound level to alert staff. Installer may need to purchase a simple audio-meter, typically available at your local electronics store, to measure the sound in areas where the alarm is expected to be heard during normal noise environment. Results from this test may prove it beneficial to purchase additional siren/strobe alarm units.
All specifications and information shown are current as of publication and subject to change without notice.
CLEANING
1. Rinse cover with water to remove abrasive dust and dirt.
2. Wash with soap or mild detergent using a soft cloth. (DO NOT SCRUB.)
3. Rinse once more, then dry with a soft cloth or chamois.
4. To remove grease or wet paint, rub gently with a cloth wetted thoroughly with naphtha, then wash and rinse. (DO NOT USE RAZOR BLADES.)
2
Page 3
DIMENSIONS
1
4
.
2
in
.
(
3
6
0
m
m
)
1
2
.2
in.
(
3
1
0
mm)
BOTTOM VIEW
F
RONT VIEW
6.44 in.
(
164mm)
2
3
.
5
in
.
(
5
9
7
m
m
)
1
6
.
5
in
.
(
4
1
9
m
m
)
1
/4
D
I
A
M
E
T
ER
SPECIFICATIONS
OPERATING VOLTAGE Internal power 9 VDC battery (not included)
OPERATING TEMPERATURE 32°F -120° POWER CONSUMPTION Stand by: 50µA
SIREN VOLUME Low: 85 dB
ALARM TIMING Independent control for siren and strobe:
LOW BATTERY WARNING LED flash once every 30 seconds
FORM C DRY CONTACTS 0-30VAC/DC, 1 Amp RATED FOR Contacts reset after longest alarm setting
KEY SWITCH Alarm on: normally closed ALARM SWITCH Stand by: normally open contact required POLYCARBONATE UL94V-2
FLAMMABILITY RATING
Remote power 12-30 VDC
Siren low volume: 85mA Siren high volume: 90mA Strobe: 25mA
High: 100 dB
15s, 30s, 60s, continuous
3
Page 4
DRILL
3-/16 DIA HOLES
19018 ANCHOR
#8-10
(2) PROVIDED
19039 SCREW #6 x 1 1/4 in. (2) PROVIDED
BASE PLATE
18074 SWITCH LOCK
SUB-SA505 KEY SWITCH MOUNTING BRACKET
3 9/32 in.
18075 REPLACEMENT #801 KEY
ENCLOSURE
ROUTE THE TWO KEY SWITCH WIRES THROUGH THE HOLE AS SHOWN
WIRE ACCESS HOLE
ROUTE THE TWO REED SWITCH WIRES FROM CABINET THROUGH THE HOLE AS SHOWN
M
19033 ANCHOR
(4) PROVIDED
04875 MOUNTING PLATE
PROVIDED
19002 SCREW #8-32 x 3/8 in. (4) PROVIDED
OPTIONAL SHELF MOUNTING POSITION
0
7530WR ADJUSTABLE SHELF INCLUDED WITH STI-7531AED ONLY
07530 CABINET ASSEMBLY
6297530 GASKET PROVIDED
06298 M
OUNTING TABS (4) PROVIDED
19013 SCREW #10 x 1 1/2 in. (
4) PROVIDED
MOUNTING TAB SLOTS
STI-7530 KEYLOCK
STI-7531 AND
STI-7531AED THUMBLOCK
INSTALLATION OF CABINET
Note: Installation of cabinet
should be before installation of alarm because the mounting bracket butts up to cabinet.
1. Insert the (4) 06298 mounting tabs fully into backbox mounting tab slots. Use rubber mallet if necessary.
2. After selecting a suitable location, place cabinet in closed position, against the wall. Mark and drill (4) 1/4 in. diameter holes. Insert the (4) 19033 anchors. Mount cabinet by driving in the four #10 x 1 1/2 in. screws.
3. For STI-7531AED select one of the two shelf mounting locations, install shelf. Close and lock cabinet.
INSTALLATION OF ALARM
STEP 1 - MOUNTING OPTIONS
TO KEY MOUNT PLATE OR INTO WALL WITHOUT ELECTRICAL BOX
4
Page 5
1
ALARM TIMING
VOLUME
STROBE TIMING
ON
OFF
1
2
3
4
5
0
S1
ALARM TONE
S
2
ALARM TIMING S
TROBE TIMING
V
OLUME
LED QTY 10
LOW BATTERY
INDICATOR LED
TERMINAL STRIP
T
AMPER SWITCH
(REAR VIEW)
WIRE ENTRY
BATTERY
B
ATTE RY CABLE
SIREN
O
STEP 2 - ELECTRONIC SETUP -
O
SELECT ALARM TONE AND TIMING SEQUENCE
NOTE: Select-Alert must be on a flat surface and lens must be
installed or the tamper switch will trigger the alarm.
STEP 3 - ALARM TONES - S1
1 2 3 4 5
1 0 0 0 0 0 BUZZ
*
2 1 0 0 0 0 SLOW ON/OFF 3 0 1 0 0 0 SLOW SIREN 4 1 1 0 0 0 3 BEEP/PAUSE/REPEAT 5 0 0 1 0 0 UFO FAST 6 1 0 1 0 0 FAST SIREN 7 0 1 1 0 0 #5 FAST 8 1 1 1 0 0 #2 MEDIUM 9 0 0 0 1 0 #5 MEDIUM
10 1 0 0 1 0 SWOOP MEDIUM 11 0 1 0 1 0 #3 MEDIUM 12 1 1 0 1 0 BUZZ TONE 13 0 0 1 1 0 STEADY FAST 14 1 0 1 1 0 SWOOP SLOW 15 0 1 1 1 0 CONTINUOUS 16 1 1 1 1 0 FAST REPEAT
WIRES TO SIREN
1 2 3 4 5
17 0 0 0 01 STANDARD ALARM 18 1 0 0 0 1 #3 FAST 19 0 1 0 0 1 #5 SLOW 20 1 1 0 0 1 FAST BEEP 21 0 0 1 0 1 SOUND A 22 1 0 1 0 1 SOUND B 23 0 1 1 0 1 SOUND C 24 1 1 1 0 1 SOUND D 25 0 0 0 1 1 SOUND D LOUD 26 1 0 0 1 1 SOUND E 27 0 1 0 1 1 SOUND F 28 1 1 0 1 1 SOUND G 29 0 0 1 1 1 SOUND H 30 1 0 1 1 1 #4 LOW 31 0 1 1 1 1 SOUND K 32 1 1 1 1 1 CONTINUOUS FAST
NOTE: Sound may be disabled by clipping
wires to the siren. THIS WILL VOID ALL WARRANTIES. Remove two screws on circuit board; leave enough length of wire to possibly reattach in the future. Then insulate wires to prevent shorting to electronic components.
STEP 4 - ALARM TIMING AND VOLUME - S2
ALARM
*
15 seconds 1111 High 30 seconds 1010 1 60 seconds 0101 Low Continuous 00 00 0
TIMING
1 = ON 0 = OFF
*Factory default settings
5
1 2
STROBESIREN
3 4 5
VOLUME
Page 6
05050- LENS COLORS A - AMBER B - BLUE G - GREEN R - RED W - WHITE
1
9002 SCREW #8-32 x 3/8 in. (
4) PROVIDED
E
LECTRONICS
I
NSTALL ED
BASE PLATE
WIRE ACCESS HOLE
1
9016 TAMPER-PROOF
TOOL (1) PROVIDED
19011 TAMPER-PROOF SCREW
ROUTE WIRES THRU HOLE
REMOTE POWER IN
12-24 VDC, 125mA
(OPTIONAL)
+
-
OFF ON
MAIN POWER
CONTROL TO KEY SWITCH
STAND
BY
REED
SWITCH FROM CABINET
FORM "C"
DRY CONTACTS
NORMALLY OPEN
COM
+
-
D
C
I
N
K
E
Y
S
W
I
T
C
H
A
L
A
R
M
S
WI
T
C
H
N
C
C
O
M
N
O
NORMALLY CLOSED
ACTIVE
STEP 5 - ELECTRONICS ASSEMBLY
Wiring: After mounting circuit board assembly, connect wires. Refer to terminal strip connections (step 6).
ens installation: Slide lip of lens behind circuit board mounting plate. Rotate lens into position. Secure with
L
amperproof screw and special wrench. Unit will not operate properly if lens cover is not installed.
t
!
STEP 6 - TERMINAL STRIP CONNECTIONS
6
NOTE: “DC IN” are the only
polarity sensitive terminals. When external power is used, battery will act as a backup. “Dry Contacts: NC, COM, NO” are used for remote alarm monitoring.
Page 7
ASSEMBLY PARTS LIST SIREN/STROBE ALARM
QTY. PART # DESCRIPTION
1 05000 Electronics assembly (includes base plate & electronics assembly) 1 05050-R Red lens (unless otherwise specified) 1 09723 Key switch mounting bracket 2 18075 #801 key 1 18074 Switch lock 1 18151 N.C. reed switch and magnet (installed in cabinet) 4 19002 Screw #8-32 x 3/8 in. 2 19039 Screw #6 x 1 1/4 in. 2 19018 Anchor #8-10 1 19011 #8-32 x 1/2 in. tamper screw 1 19016 Tamper wrench 1 BAT-9VDC 9 volt battery
CABINET
1 07530 Hinged polycarbonate enclosure 4 06298 Mounting tabs 4 19013 #10 x 1 1/2 in. screw 4 19033 Plastic anchor 1 07530WR Wire shelf (Included with AED models only) 1 04875 Mounting plate 4 19002 #8-32 x 3/8 in. screw 1 06297530 Gasket 1 07503 Thumb lock - STI-7535 models 1 18050 Key lock 2 18054 CH751 Key
}
STI-7534 models
STEP 7 - OPERATION
• Turn key switch on to arm.
• Cycle key switch to reset alarm.
• Alarm will sound when cabinet is opened (alarm switch is electronically closed), alarm cover is removed or unit is removed from the wall.
• To service, turn key switch off.
WARRANTY INFORMATION
• Three year guarantee against breakage of polycarbonate in normal use
(one year on electro mechanical and electronic components).
• Electronic warranty form at www.sti-usa.com/wc14.
7
Page 8
ACCESSORIES AND REPLACEMENT PARTS
AED-LBL AED label - 2 included (applied to sides of
cabinet; must be factory installed)
STI-SA5000-R Replacement Siren/Strobe Alarm 18054 Replacement key for cabinet lock on STI-7534 18075 Replacement key for Siren/Strobe Alarm 07530WR Wire shelf (included with AED models)
2306 Airport Road
Waterford, Michigan 48327-1209
Phone: 248-673-9898 • Toll Free: 800-888-4784 • Fax: 248-673-1246
www.sti-usa.com
Safety Technology International (Europe) Ltd.
Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch
Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only)
E-mail: info@sti-europe.com • Web: www.sti-europe.com
Printed in USA SUBJECT TO CHANGE WITHOUT NOTICE Inst. Sht. STI-7535/STI-7535AED, JAN2014
Loading...