All units are recommended for indoor use. Unit must be tested periodically to
verify the life of battery. STI recommends you change the 9 Volt battery twice
a year. When purchasing a siren/strobe alarm, you will need to periodically
test the connections to make sure audibles function at a sound level to alert
staff. Installer may need to purchase a simple audio-meter, typically available
at your local electronics store, to measure the sound in areas where the alarm
is expected to be heard during normal noise environment. Results from this
test may prove it beneficial to purchase additional siren/strobe alarm units.
All specifications and information shown are current as of publication and
subject to change without notice.
CLEANING
1. Rinse cover with water to remove abrasive dust and dirt.
2. Wash with soap or mild detergent using a soft cloth. (DO NOT SCRUB.)
3. Rinse once more, then dry with a soft cloth or chamois.
4. To remove grease or wet paint, rub gently with a cloth wetted thoroughly
with naphtha, then wash and rinse. (DO NOT USE RAZOR BLADES.)
2
Page 3
DIMENSIONS
1
4
.
2
in
.
(
3
6
0
m
m
)
1
2
.2
in.
(
3
1
0
mm)
BOTTOM VIEW
F
RONT VIEW
6.44 in.
(
164mm)
2
3
.
5
in
.
(
5
9
7
m
m
)
1
6
.
5
in
.
(
4
1
9
m
m
)
1
/4
”
D
I
A
M
E
T
ER
SPECIFICATIONS
OPERATING VOLTAGEInternal power 9 VDC battery (not included)
OPERATING TEMPERATURE32°F -120°
POWER CONSUMPTIONStand by: 50µA
SIREN VOLUMELow: 85 dB
ALARM TIMINGIndependent control for siren and strobe:
LOW BATTERY WARNINGLED flash once every 30 seconds
FORM C DRY CONTACTS0-30VAC/DC, 1 Amp
RATED FORContacts reset after longest alarm setting
KEY SWITCHAlarm on: normally closed
ALARM SWITCHStand by: normally open contact required
POLYCARBONATEUL94V-2
FLAMMABILITY RATING
Remote power 12-30 VDC
Siren low volume: 85mA
Siren high volume: 90mA
Strobe: 25mA
High: 100 dB
15s, 30s, 60s, continuous
3
Page 4
DRILL
3-/16 DIA HOLES
19018 ANCHOR
#8-10
(2) PROVIDED
19039 SCREW
#6 x 1 1/4 in.
(2) PROVIDED
BASE PLATE
18074 SWITCH LOCK
SUB-SA505 KEY SWITCH
MOUNTING BRACKET
3 9/32 in.
18075 REPLACEMENT
#801 KEY
ENCLOSURE
ROUTE THE TWO KEY
SWITCH WIRES THROUGH
THE HOLE AS SHOWN
WIRE ACCESS HOLE
ROUTE THE TWO REED
SWITCH WIRES FROM
CABINET THROUGH THE
HOLE AS SHOWN
M
19033 ANCHOR
(4) PROVIDED
04875 MOUNTING PLATE
PROVIDED
19002 SCREW
#8-32 x 3/8 in.
(4) PROVIDED
OPTIONAL SHELF
MOUNTING POSITION
0
7530WR
ADJUSTABLE SHELF
INCLUDED WITH
STI-7531AED ONLY
07530 CABINET
ASSEMBLY
6297530
GASKET PROVIDED
06298
M
OUNTING TABS (4) PROVIDED
19013 SCREW
#10 x 1 1/2 in.
(
4) PROVIDED
MOUNTING
TAB SLOTS
STI-7530 KEYLOCK
STI-7531 AND
STI-7531AED THUMBLOCK
INSTALLATION OF CABINET
Note: Installation of cabinet
should be before
installation of alarm
because the mounting
bracket butts up to
cabinet.
1. Insert the (4) 06298
mounting tabs fully into
backbox mounting tab
slots. Use rubber mallet if
necessary.
2. After selecting a suitable
location, place cabinet in
closed position, against the wall. Mark and drill (4) 1/4 in. diameter holes.
Insert the (4) 19033 anchors. Mount cabinet by driving in the four #10 x
1 1/2 in. screws.
3. For STI-7531AED select one of the two shelf mounting locations, install
shelf. Close and lock cabinet.
INSTALLATION OF ALARM
STEP 1 - MOUNTING OPTIONS
TO KEY MOUNT PLATE OR INTO WALL WITHOUT ELECTRICAL BOX
4
Page 5
1
ALARM TIMING
VOLUME
STROBE TIMING
ON
OFF
1
2
3
4
5
0
S1
ALARM TONE
S
2
ALARM TIMING
S
TROBE TIMING
V
OLUME
LED QTY 10
LOW BATTERY
INDICATOR LED
TERMINAL STRIP
T
AMPER SWITCH
(REAR VIEW)
WIRE ENTRY
BATTERY
B
ATTE RY CABLE
SIREN
O
STEP 2 - ELECTRONIC SETUP -
O
SELECT ALARM TONE AND TIMING SEQUENCE
NOTE: Select-Alert must be on a flat surface and lens must be
installed or the tamper switch will trigger the alarm.
17 0 0 0 01STANDARD ALARM
18 1 0 0 0 1#3 FAST
19 0 1 0 0 1#5 SLOW
20 1 1 0 0 1FAST BEEP
21 0 0 1 0 1SOUND A
22 1 0 1 0 1SOUND B
23 0 1 1 0 1SOUND C
24 1 1 1 0 1SOUND D
25 0 0 0 1 1SOUND D LOUD
26 1 0 0 1 1SOUND E
27 0 1 0 1 1SOUND F
28 1 1 0 1 1SOUND G
29 0 0 1 1 1SOUND H
30 1 0 1 1 1#4 LOW
31 0 1 1 1 1SOUND K
32 1 1 1 1 1CONTINUOUS FAST
NOTE: Sound may be disabled by clipping
wires to the siren. THIS WILL VOID ALL
WARRANTIES. Remove two screws on
circuit board; leave enough length of
wire to possibly reattach in the future.
Then insulate wires to prevent shorting
to electronic components.
05050- LENS COLORS
A - AMBER
B - BLUE
G - GREEN
R - RED
W - WHITE
1
9002 SCREW
#8-32 x 3/8 in.
(
4) PROVIDED
E
LECTRONICS
I
NSTALL ED
BASE PLATE
WIRE ACCESS HOLE
1
9016 TAMPER-PROOF
TOOL (1) PROVIDED
19011 TAMPER-PROOF
SCREW
ROUTE WIRES
THRU HOLE
REMOTE POWER IN
12-24 VDC, 125mA
(OPTIONAL)
+
-
OFF ON
MAIN POWER
CONTROL TO
KEY SWITCH
STAND
BY
REED
SWITCH FROM CABINET
FORM "C"
DRY CONTACTS
NORMALLY OPEN
COM
+
-
D
C
I
N
K
E
Y
S
W
I
T
C
H
A
L
A
R
M
S
WI
T
C
H
N
C
C
O
M
N
O
NORMALLY CLOSED
ACTIVE
STEP 5 - ELECTRONICS ASSEMBLY
Wiring: After mounting circuit board assembly, connect wires. Refer to terminal strip connections (step 6).
ens installation: Slide lip of lens behind circuit board mounting plate. Rotate lens into position. Secure with
L
amperproof screw and special wrench. Unit will not operate properly if lens cover is not installed.
t
!
STEP 6 - TERMINAL STRIP CONNECTIONS
6
NOTE: “DC IN” are the only
polarity sensitive
terminals. When
external power is
used, battery will
act as a backup.
“Dry Contacts: NC,
COM, NO” are used
for remote alarm
monitoring.
Page 7
ASSEMBLY PARTS LIST
SIREN/STROBE ALARM
QTY. PART #DESCRIPTION
1 05000Electronics assembly (includes base plate & electronics assembly)
1 05050-RRed lens (unless otherwise specified)
1 09723Key switch mounting bracket
2 18075#801 key
1 18074Switch lock
1 18151N.C. reed switch and magnet (installed in cabinet)
4 19002Screw #8-32 x 3/8 in.
2 19039Screw #6 x 1 1/4 in.
2 19018Anchor #8-10
1 19011#8-32 x 1/2 in. tamper screw
1 19016Tamper wrench
1 BAT-9VDC 9 volt battery