All units are recommended for indoor use. Unit must be tested periodically to
verify the life of battery. STI recommends you change the 9 Volt battery twice
a year. When purchasing a siren/strobe alarm, you will need to periodically
test the connections to make sure audibles function at a sound level to alert
staff. Installer may need to purchase a simple audio-meter, typically available
at your local electronics store, to measure the sound in areas where the alarm
is expected to be heard during normal noise environment. Results from this
test may prove it beneficial to purchase additional siren/strobe alarm units.
All specifications and information shown are current as of publication and subject to change without notice.
CLEANING
1. Rinse cover with water to remove abrasive dust and dirt.
2. Wash with soap or mild detergent using a soft cloth. (DO NOT SCRUB.)
3. Rinse once more, then dry with a soft cloth or chamois.
4. To remove grease or wet paint, rub gently with a cloth wetted thoroughly
with naphtha, then wash and rinse. (DO NOT USE RAZOR BLADES.)
2
DIMENSIONS
3
.29 in.
(83.95mm)
19.46 in.
(
494.34mm)
4.80 in.
(121.84mm)
7.11 in.
(180.64mm)
1
2.49 in.
(317.35mm)
1
/4”
DIAMETER
SPECIFICATIONS
OPERATING VOLTAGE Internal power 9 VDC battery (not included)
Remote power 12-30 VDC
OPERATING TEMPERATURE 32°F -120°
POWER CONSUMPTION Stand by: 50µA
Siren low volume: 85mA
Siren high volume: 90mA
Strobe: 25mA
SIREN VOLUME Low: 85 dB
High: 100 dB
ALARM TIMING Independent control for siren and strobe:
15s, 30s, 60s, continuous
LOW BATTERY WARNING LED flash once every 30 seconds
FORM C DRY CONTACTS 0-30VAC/DC, 1 Amp
RATED FOR Contacts reset after longest alarm setting
KEY SWITCH Alarm on: normally closed
ALARM SWITCH Stand by: normally open contact required
POLYCARBONATE UL94V-2
FLAMMABILITY RATING
3
DRILL
3-/16 DIA HOLES
19018 ANCHOR
#8-10
(2) PROVIDED
19039 SCREW
#6 x 1 1/4 in.
(2) PROVIDED
BASE PLATE
18074 SWITCH LOCK
SUB-SA505 KEY SWITCH
MOUNTING BRACKET
3 9/32 in.
18075 REPLACEMENT
#801 KEY
ENCLOSURE
ROUTE THE TWO KEY
SWITCH WIRES THROUGH
THE HOLE AS SHOWN
WIRE ACCESS HOLE
ROUTE THE TWO REED
SWITCH WIRES FROM
CABINET THROUGH THE
HOLE AS SHOWN
INSTALLATION OF CABINET
Note: Installation of cabinet
should be before installation of alarm because
the mounting bracket
butts up to cabinet.
1. Insert the (4) 06298 mounting tabs fully into
back box mounting tab slots. Use rubber mallet
if necessary.
2. After selecting a suitable location, place cabinet in closed position, against the wall. Mark
and drill (4) 1/4 in. diameter holes. Insert the
(4) 19033 anchors. Mount cabinet by driving
in the four #10 x 1 1/2 in. screws.
INSTALLATION OF ALARM
STEP 1 - MOUNTING OPTIONS
TO KEY MOUNT PLATE OR INTO WALL WITHOUT ELECTRICAL BOX
4
1
ALARM TIMING
VOLUME
STROBE TIMING
ON
OFF
1
2
3
4
5
0
S1
ALARM TONE
S
2
A
LARM TIMING
STROBE TIMING
VOLUME
L
ED QTY 10
LOW BATTERY
I
NDICATOR LED
T
ERMINAL STRIP
TAMPER SWITCH
(
REAR VIEW)
W
IRE ENTRY
B
ATTE RY
BATTERY CABLE
S
IREN
O
STEP 2 - ELECTRONIC SETUP - SELECT ALARM TONE
O
O
AND TIMING SEQUENCE
NOTE: Select-Alert must be on a flat surface and lens must be
installed or the tamper switch will trigger the alarm.
17 0 0 0 01 STANDARD ALARM
18 1 0 0 0 1 #3 FAST
19 0 1 0 0 1 #5 SLOW
20 1 1 0 0 1 FAST BEEP
21 0 0 1 0 1 SOUND A
22 1 0 1 0 1 SOUND B
23 0 1 1 0 1 SOUND C
24 1 1 1 0 1 SOUND D
25 0 0 0 1 1 SOUND D LOUD
26 1 0 0 1 1 SOUND E
27 0 1 0 1 1 SOUND F
28 1 1 0 1 1 SOUND G
29 0 0 1 1 1 SOUND H
30 1 0 1 1 1 #4 LOW
31 0 1 1 1 1 SOUND K
32 1 1 1 1 1 CONTINUOUS FAST
NOTE: Sound may be disabled by clipping
wires to the siren. THIS WILL VOID ALL
WARRANTIES. Remove two screws on circuit board; leave enough length of wire
to possibly reattach in the future. Then
insulate wires to prevent shorting to
electronic components.
Wiring: After mounting circuit board assembly, connect wires. Refer to terminal strip connections (step 6).
Lens installation: Slide lip of lens behind circuit board mounting plate. Rotate lens into position. Secure with
tamperproof screw and special wrench. Unit will not operate properly if lens cover is not installed.
!
STEP 6 - TERMINAL STRIP CONNECTIONS
6
NOTE: “DC IN” are the only
polarity sensitive
terminals. When
external power is
used, battery will
act as a backup.
“Dry Contacts: NC,
COM, NO” are used
for remote alarm
monitoring.
ASSEMBLY PARTS LIST
SIREN/STROBE ALARM
QTY. PART # DESCRIPTION
1 05000 Electronics assembly (includes base plate & electronics assembly)
1 05050-R Red lens (unless otherwise specified)
1 09723 Key switch mounting bracket
2 18075 #801 key
1 18074 Switch lock
1 18151 N.C. reed switch and magnet (installed in cabinet)
4 19002 Screw #8-32 x 3/8 in.
2 19039 Screw #6 x 1 1/4 in.
2 19018 Anchor #8-10
1 19011 #8-32 x 1/2 in. tamper screw
1 19016 Tamper wrench
1 BAT-9VDC 9 volt battery
CABINET
1 07520 Hinged polycarbonate enclosure
4 06298 Mounting tabs
4 19013 #10 x 1 1/2 in. screw
4 19033 Plastic anchor
1 04874 Mounting plate
4 19002 #8-32 x 3/8 in. screw
1 06297520 Gasket
1 07503 Thumb lock - STI-7525 models
1 18050 Key lock
2 18054 CH751 Key
STI-7524 models
}
STEP 7 - OPERATION
• Turn key switch on to arm.
• Cycle key switch to reset alarm.
• Alarm will sound when cabinet is opened (alarm switch is electronically
closed), alarm cover is removed or unit is removed from the wall.
• To service, turn key switch off.
WARRANTY INFORMATION
• Three year guarantee against breakage of polycarbonate in normal use
(one year on electro mechanical and electronic components).
• Electronic warranty form at www.sti-usa.com/wc14.
7
ACCESSORIES AND REPLACEMENT PARTS
STI-SA5000-R Replacement Siren/Strobe Alarm
18054 Replacement key for cabinet lock on STI-7524
18075 Replacement key for Siren/Strobe Alarm
2306 Airport Road • Waterford, MI 48327
Phone: 248-673-9898 • Fax: 248-673-1246
info@sti-usa.com • www.sti-usa.com
Safety Technology International (Europe) Ltd.
Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch