Sterling XF150A1NS111 Specifications Sheet

STERLING “XF” SERIES CONVERTIBLE VENTING TYPE TUBULAR PROPELLER UNIT HEATER
DESCRIPTION
The Sterling “XF” Series Convertible Venting Type Tubular Propeller Gas­Fired Unit Heater offers a highly efficient, extremely durable alternative to the traditional clam shell design. These propeller type units combine the latest tubular heat exchanger and in-shot burner technology with the quality and reliability you have come to know from Sterling. Units are available in sizes 100 to 400 MBH and have been certified by ETL as providing 83% thermal (combustion) efficiency.
CONVERTIBLE VENTING - STANDARD OR SEPARATED COMBUSTION
Notably, the Sterling “XF” unit heater is designed so it can be installed in either standard or separated combustion venting configurations without requiring modification to the unit itself. Located on the rear cover panel of each unit, combustion air inlet collars are left open in a standard combustion venting configuration. When set up for separated combustion, combustion air piping is connected to the inlet collars so that the burners, spark ignitor, and flue system are enclosed within the unit, allowing the entire combustion process to remain unaffected by the atmosphere in the space where the heater is located. Separated combustion venting configurations should be used where dusty, dirty or mildly corrosive conditions exist, or where high humidity or slightly negative pressures prevail.
ADDITIONAL VENTING FLEXIBILITY
The Sterling “XF” unit heater is ETL certified in accordance with categories I and III venting requirements. This certification allows units to be vented both vertically and horizontally using either single wall or double wall venting materials. Available as an accessory option, Sterling offers a Combustion Air Inlet Kit that allows for concentric venting of both combustion and exhaust air systems through one termination.
TUBULAR HEAT EXCHANGER
The Sterling tubular heat exchanger has been designed to provide maximum and uniform heat transfer. The low pressure drop associated with this design enables heated air to be evenly distributed to the conditioned space. This curved, non-welded serpentine design experiences less thermally induced stress making it highly durable for significantly longer service life. All Sterling tubular heat exchangers are constructed of heavy duty 20-gauge aluminized steel. Optional 409 stainless steel heat exchangers are also available.
DIRECT SPARK IGNITION SYSTEM & CONTROL ACCESSIBILITY
Sterling “XF” units utilize a direct spark pilotless ignition of the burner, providing fast heat delivery. This highly reliable and efficient ignition system incorporates an integrated electronic control board to regulate the system sequence of operation, including an externally mounted LED indicator for simple troubleshooting. Designed with the service person in mind, ignition and fan controls are located in one centrally located control panel.
CAUTIONS
Combustion air and vent systems must be installed in accordance with current National Fuel Gas Code or Installation Code, Installation Code for Natural Gas Burning Appliances and Equipment (Canada) and any local and state codes. Units should not be installed where negative pressures are significant, where vapor containing chlorine or fluorine may be present or in any areas classified as "hazardous."
STANDARD FEATURES
• Designed for either standard or separated combustion
• 20-gauge aluminized steel tubular heat exchanger
• 83% thermal efficiency
• ODP propeller motor (with overload protection)
• Power venter
• Combustion air pressure switch
• 20-gauge steel cabinetry with baked enamel finish
• Direct spark ignition system
• 115/24 volt control transformer
• 115/1/60 supply voltage
• Redundant single stage gas valve
• Rear access to in-shot burners
• Individually adjustable and removable horizontal louvers
• Complete fan guard
• Main control panel
• 10 year heat exchanger, flue collector and burner warranty
OPTIONAL FEATURES
• Stainless steel heat exchanger, burners, and/ or flue collector
• Two stage and various electronic modulation gas controls
• Discharge nozzles (30°, 60° & 90°)
• Combustion air inlet kits (allows concentric venting with horizontal or vertical termination)
• TE propeller motor
• Supply voltages: 208 & 230/1/60 and 208, 230, 460, 575/3/60
XFS-1
08/19
PROJECT:
UNIT TAG:
260 North Elm St., Westfield, MA 01085
(413) 564-5540 Fax: (413) 562-5311
www.sterlinghvac.com
“XF” CONVERTIBLE VENTING TUBULAR PROPELLER
(Hanging)
M
PERFORMANCE AND DIMENSIONAL DATA
Unit Capacity (MBH) 100 125 150 175 200 250 300 350 400 PERFORMANCE DATA†
Input - BTU/Hr. 100,000 125,000 150,000 175,000 200,000 250,000 300,000 350,000 400,000 (kW) (29.3) (36.6) (43.9) (51.2) (58.6) (73.2) (87.8) (102.5) (117.1) Output - BTU/Hr. 83,000 103,750 124,500 145,250 166,000 207,500 249,000 290,500 332,000 (kW) (24.3) (30.4) (36.4) (42.5) (48.6) (60.7) (72.9) (85.1) (97.2) Thermal Efficiency - % 83 83 83 83 83 83 83 83 83 Free Air Delivery - CFM 1,600 2,200 2,400 2,850 3,200 3,450 5,000 5,600 5,800
(cu. m/s) (0.756) (1.039) (1.133) (1.346) (1.511) (1.629) (2.361) (2.644) (2.738)
Air Temperature Rise -Deg. F 47 42 47 46 47 54 45 47 51
(Deg. C) (26) (23) (26) (26) (26) (30) (24) (26) (28) Full Load Amps at 120V 6.4 6.9 6.9 8.0 8.0 8.0 11.6 13.8 13.8 Min. Circuit Amps at 120V 7.5 8.1 8.1 9.5 9.5 9.5 12.8 15.3 15.3
MOTOR DATA:
Motor HP 1/10 1/4 1/4 1/3 1/3 1/3 1/4 (2) 1/3 (2) 1/3 (2) Motor kW (0.08) (0.19) (0.19) (0.25) (0.25) (0.25) (0.19) (0.25) (0.25) Motor Type (ODP)
SP PSC PSC PSC PSC PSC PSC PSC PSC RPM 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 Amps @ 115V 4.2 4.7 4.7 5.8 5.8 5.8 9.4 11.6 11.6
DIMENSIONAL DATA - inches (mm)
"A" Overall Height to Top of Flue 33-3/4 33-3/4 33-3/4 33-3/4 33-3/4 33-3/4 34 34 34
(857) (857) (857) (857) (857) (857) (864) (864) (864)
"B" Jacket Width of Unit 20-3/4 20-3/4 20-3/4 32-3/4 32-3/4 32-3/4 50-3/4 50-3/4 50-3/4
(527) (527) (527) (831) (831) (831) (1289) (1289) (1289)
"C" Width to CL Flue 13-3/8 13-3/8 13-3/8 19-3/8 19-3/8 19-3/8 28-3/8 28-3/8 28-3/8
(340) (340) (340) (492) (492) (492) (721) (721) (721)
"D" Depth to Rear of Housing 11 11 11 11 11 11 12-1/4 12-1/4 12-1/4
(279) (279) (279) (279) (279) (279) (311) (311) (311)
"E" Hanging Distance Width 18-5/8 18-5/8 18-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8
(473) (473) (473) (778) (778) (778) (1235) (1235) (1235)
"F" Discharge Opening Width 18-3/4 18-3/4 18-3/4 30-3/4 30-3/4 30-3/4 48-3/4 48-3/4 48-3/4
(476) (476) (476) (781) (781) (781) (1238) (1238) (1238)
"G" Depth to CL Flue 4-3/4 4-3/4 4-3/4 4-3/4 4-3/4 4-3/4 5-1/8 5-1/8 5-1/8
(121) (121) (121) (121) (121) (121) (130) (130) (130)
"L" Overall Unit Width 25-1/4 25-1/4 25-1/4 37-1/4 37-1/4 37-1/4 55-1/4 55-1/4 55-1/4
(641) (641) (641) (946) (946) (946) (1403) (1403) (1403)
Combustion Air Inlet Dia. (Qty) - in 5 5 5 5 5 5 5 (2) 5 (2) 5 (2)
(mm) (127) (127) (127) (127) (127) (127) (127) (127) (127) "M" Flue Size Diameter* - in 5 5 5 5 5 5 6 6 6
(mm) (127) (127) (127) (127) (127) (127) (152) (152) (152) Gas Inlet, Natural Gas - in 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 Gas Inlet, LP Gas - in 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 Approximate Unit Weight - lb 135 147 157 194 204 214 311 325 339
(kg) (61) (67) (71) (88) (93) (97) (141) (147) (154) Approximate Ship Weight - lb 175 187 197 244 254 264 371 385 399
(kg) (79) (85) (89) (111) (115) (120) (168) (175) (181)
† Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 610m). For unit installations in U.S.A. above 2,000 ft. (610m), the unit input must be field derated 4% for each
1,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223.1 (N.F.P.A. No. 54).
For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (610m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (610 to 1372m), the unit must be field derated
and be so marked in accordance with the ETL certification. See unit installation manual for field deration information.
* Flue collar is factory supplied with unit; to be field installed per included instructions.
** LEGEND: SP = SHADED POLE PSC = PERMANENT SPLIT CAPACITOR ODP = OPEN DRIP PROOF
1
1
8
(29mm)
(Flue Diameter)
"
(Hanging)
C
E
D
G
5
11
8
(295mm)
(Hanging)
"
1
32
2
(826mm)
"
L
B
Combustion Air Inlet
Rear View
Electrical Control Panel
Gas Valve Connection
Side View
High Limit Access
F
(Discharge
Opening)
Front View
1
24
2
(622mm)
(Discharge
Opening)
1"
(25mm)
CAT-10364_A
33"
(838mm)
"
A