Product Data
GGPD-5
INDUSTRIAL, COMMERCIAL
AND RESIDENTIAL
GARAGE CERTIFIED
ETL LISTED
DIRECT
SPARK IGNITION
RELIABLE BURNER IGNITION
TWO
STAGE GAS
GG SERIES
GG SERIES
GAS-FIRED UNIT HEATER
GAS-FIRED UNIT HEATER
AVAILABLE ON SIZES 60-120
TUBULAR
HEAT EXCHANGER
ALUMINIZED STEEL
Stainless Steel Option Available
SINGLE
ORIFICE BURNER
ONE BURNER TO SERVICE
ONE BURNER TO CONVERT
321 STAINLESS STEEL BURNER BOX
DUAL VENTING
STANDARD UNIT CAN BE FIELD
CONVERTED TO SEPARATED
COMBUSTION WITH OPTIONAL
COMBUSTION AIR INLET KIT
260 NORTH ELM ST. WESTFIELD, MA 01085
(413) 568-9571 • FAX: (413) 562-5311
www.sterlinghvac.com
GAS CONVERSION
KIT INCLUDED
STANDARD WITH EVERY UNIT

STANDARD FEATURES
• 82+% Thermal Efficiency
• Redundant Single -Stage
Gas Valve
• Residential Certification
• 120/24V Control
Transformer
• OSHA Fan Guard
•
115/1/60 Fan Motor with
Internal Overload Protection
• Direct Spark Ignition
• 20-Gauge Cabinet with
Baked Enamel Finish
• 10 Year Heat Exchanger
Warranty
•
Right Hand Control Access Field Convertible to Left Hand
• High Limit Switch
• Air Pressure Switch
OPTIONAL FEATURES
• 409 Stainless Steel Heat
Exchanger
• 2-Stage Gas Control
(Sizes 60-120 Only)
• Stainless Steel Flue
Collector
• Supply Voltage (Field
Mounted Transformers):
— 208/1/60
— 230/1/60
— 208/3/60
— 230/3/60
— 460/3/60
— 575/3/60
DIMENSIONAL DATA
• Natural or Propane Gas
• Gas Conversion Kit
Included
• Field Convertible to
Separated Combustion
• Easy Access Control
Panel
• 321 Stainless Steel
Burner Box
• Vent Caps
• Totally Enclosed Motors
(Sizes 60-120 Only)
• Pressure Regul ator
(1/2-35 psi)
• Single & 2-Stage Mercury
Free Thermostats
• Line Volt Thermostat
• 20-G auge Aluminized
Steel Heat Exchanger
• Power Vented
• Locking Thermostat Cover
• 24V SPST Relay
• Combustion Air Inlet Kits
(For All Separated
Combustion Installations)
DIMENSIONS .XXX STANDARD UNITS
DIMENSIONS IN PARENTHESIS (XXX) MILLIMETERS

PERFORMANCE AND DIMENSIONAL DATA
UNIT CAPACITY (MBH) 30 45 60 75 90 105 120
PERFORMANCE DATA†
Input - BTU/Hr 30,000 45,000 60,000 75,000 90,000 105,000 120,000
(kW) (8.8) (13.2) (17.6) (22.0) (26.4) (30.8) (35.2)
Output - BTU/Hr 24,900 37,350 49,800 61,500 73,800 86,100 98,400
(kW) (7.2) (10.9) (14.5) (18.0) (21.6) (25.2) (28.8)
Thermal Efficiency - % 83 83 83 82 82 82 82
Free Air Delivery - CFM 370 550 740 920 1,100 1,300 1,475
(cu. m/s) (.175) (.260) (.349) (.434) (.519) (.614) (.696)
Air Temperature Rise - °F 60 60 60 60 60 60 60
(°C) (15) (15) (15) (15) (15) (15) (15)
Full Load Amps at 120V 3.2 3.2 4.1 4.1 6.4 6.4 6.4
Maximum Circuit Ampacity 3.7 3.7 4.8 4.8 7.5 7.5 7.5
MOTOR DATA: Motor HP 1/20 1/20 1/12 1/12 1/10 1/10 1/10
Motor (kW) (0.04) (0.04) (0.06) (0.06) (0.075) (0.075) (0.075)
Motor Type ODP†† SP SP SP SP SP SP SP
RPM 1650 1650 1050 1050 1050 1050 1050
Motor Amps @ 115V 1.9 1.9 2.6 2.6 4.2 4.2 4.2
DIMENSIONAL DATA - Inches (mm)
“A” Jacket Height 12-3/8 12-3/8 15-7/8 15-7/8 22-5/8 22-5/8 22-5/8
(314) (314) (403) (403) (574) (574) (574)
“B” Overall Height 13-1/4 13-1/4 16-13/16 16-13/16 23-9/16 23-9/16 23-9/16
(337) (337) (427) (427) (598) (598) (598)
“C” Overall Depth 25-7/8 25-7/8 26-3/16 26-3/16 26-3/8 26-3/8 26-3/8
(632) (632) (665) (665) (670) (670) (670)
“D1” Center Line Height of Flue* 8-1/2 8-1/2 10-3/8 10-3/8 13-5/8 13-5/8 13-5/8
(216) (216) (263) (263) (346) (346) (346)
“D2” Center Line Height of Air Intake 8-1/2 8-1/2 8 8 8-5/8 8-5/8 8-5/8
(216) (216) (203) (203) (219) (219) (219)
“E” Fan Diameter 10 10 14 14 16 16 16
(254) (254) (356) (356) (406) (406) (406)
“F” Discharge Opening Height 10-13/16 10-13/16 14-7/16 14-7/16 21-3/16 21-3/16 21-3/16
(275) (275) (367) (367) (538) (538) (538)
“G” Vent Connection Diameter 4 4 4 4 4 4 4
(102) (102) (102) (102) (102) (102) (102)
“H1” Center Line of Flue Connection From Side
(184) (184) (184) (184) (197) (197) (184)
“H2” Center Line of Air Intake From Side 2-3/4 2-3/4 2-3/4 2-3/4 3-1/2 3-1/2 3-1/2
(70) (70) (70) (70) (89) (89) (89)
VENT SIZE REQUIREMENTS - STANDARD COMBUSTION
Category III Horizontal - Inches (mm) 4 4 4 4 4 4 4
(102) (102) (102) (102) (102) (102) (102)
Category I & III Vertical - Inches (mm) 4 4 4 4 4 4 4
(102) (102) (102) (102) (102) (102) (102)
VENT SIZE REQUIRMENTS - SEPARATED COMBUSTION
Exhaust Diameter - Inches (mm) 4 4 4 4 5 5 5
(102) (102) (102) (102) (127) (127) (127)
Intake Air Diameter - Inches (mm) 4 4 4 4 5 5 5
(102) (102) (102) (102) (127) (127) (127)
Unit Weight - Lbs 60 65 80 85 95 105 110
(kgs) (27) (29) (36) (39) (43) (48) (50)
Shipping Weight - Lbs 70 75 90 95 110 115 120
(kgs) (32) (34) (41) (43) (50) (52) (54)
*For all installations, the flue collar is included with the unit and should be field installed per the instructions included with the unit.
† Ratings shown are for unit installations at elevations between 0 and 2,000 feet (0 to 610m). For unit installations in USA above 2,000 feet (610m), the unit input must be field derated 4% for each
1,000 feet (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223.1
(NFPA No. 54).
For installations in Canada, any reference to deration at altitudes in excess of 2,000 feet (610m) are to be ignored. At altitudes of 2,000 feet to 4,500 feet (610 to 1372m), the unit must be field
derated and be so marked in accordance with the ETL certification. See unit installation, operation and maintenance manual for deration information.
†† LEGEND: ODP = OPEN DRIP PROOF SP = SHADED POLE
7-1/4 7-1/4 7-1/4 7-1/4 7-3/4 7-3/4 7-1/4

260 NORTH ELM ST. WESTFIELD, MA 01085
(413) 568-9571 • FAX: (413) 562-5311
www.sterlinghvac.com