Sterling CFP25-A, CFP05-W, CFP05-30W, CFP30-W, CFP05-A User Manual

...

Specifications and Main Features

  • Models: CFPO5-W to CFP30-W, CFPO5-A to CFP25-A
  • Type: Air Cooled, Water Cooled
  • Horsepower: 5 HP to 30 HP available
  • Voltage: 230/208-3-60, 30/3510-380-3-50, 460-3-60, 515-3-50, 575-3-60
  • Temperature Ranges:
  • R-22 units: 20° to 70° processes
  • Low temperature R-502 Unit: 0° to 30° processes
  • Normal Reservoir Size: 40 gallons
  • Static Fan: Forced for Air Cooled 5 to 15 HP
  • Automatic Make Up System: not mandatory
  • Safety: Freezestat control, cut out high pressure , cut out low pressure , oil pressure switch
  • Shipping: Ready to use packaged and shipped as a complete unit,
  • Servicing: Always includes regularly scheduled cleaning of the air filters and condenser maintenance

Frequently Asked Questions

Q: What are the cooling range for the STERLCOOL Portable Chillers?

A: The cooling range are 20 degrees to 70 degrees for the R-22 charged portable chillers and low temperature R-502 units portable chillers upto 30 degrees more.

Q: Are there any other power supply configurations how can these chillers be supplied?

A: These units can be made to suit 230/208-3-60, 30/3510-380-3-50, 460-3-60, 515-3-50 and 575-3-60 supplies configurations.

Q: Is it possible for chillers to be suitable for outdoor and indoor use?

A: Absolutely Yes, a variety of installation settings can be catered to depending upon the unit (water cooled or air cooled) design.

Q: What kind of safety features have been integrated STERLCOOL?

A: These features include Freezestat control high pressure cut out, low pressure cut out and oil pressure switch.

Q: Is there any type of automatic water make-up system available?

A: Yes, make-up systems are offered as optional extras, and these do include the necessary equipment to ensure smooth functioning.

Q: What is the rough time period for carrying out routine maintenance?

A: In most cases, chillers should function optimally for a period of time which vary, roughly estimated every three months after which routine maintenance should be carried out to ensure longevity.

User Manual

Page 1
Sterling CFP25-A, CFP05-W, CFP05-30W, CFP30-W, CFP05-A User Manual
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
Page 11
Page 12
Page 13
Page 14
Page 15
Page 16
Page 17
Page 18
Page 19
Page 20
Page 21
Page 22
Page 23
Page 24
Page 25
Page 26
Page 27
Page 28
Page 29
Page 30
Page 31
Page 32
Page 33
Page 34
Page 35
Page 36
Page 37
Page 38
Page 39
Page 40
Loading...