SteriPEN Protector Opti User Manual

Thank you for selecting SteriPEN® Protector
Opti
. Years of careful research, development and testing have gone into this unique UV water purification product.
Directions for Use 40 C.F.R. §156.10(i)(2)
SteriPEN® purifiers meet or exceed U.S. EPA Guide Standard and Protocol for Testing Microbiological Water Purifiers, destroying over 99.9999% of bacteria,
99.99% of viruses, and 99.9% of protozoa (giardia & cryptosporidium) when used as directed. SteriPEN® Protector
Opti
is not a sterilizer.
SteriPEN® Protector
Opti
requires use in bottles or containers with a minimum
opening of 4.4 cm (1.75 in.).
Operating the SteriPEN® Protector
Opti
Safety
SteriPEN® Protector
Opti
may be used in glass, plastic, ceramic or metal containers. They all absorb and reflect UV light, thereby shielding the user from UV exposure. Protector
Opti
should not be used in quartz containers. The air/ water interface at the top of any drinking container is highly reflective to UV and reflects UV back into the container.
Optical Water Sensor
SteriPEN
®
Protector
Opti
features an advanced proprietary optical water sensing technology. This is an important safety feature intended to prevent UV exposure by permitting operation only when lamp is completely immersed in water. Never attempt to bypass this featur e. If the St eriPEN
®
Protector
Opti
does not detect
water within 15 seconds of being activated, it will deactivate.
Agitation of Water
Agitation of the water by stirring with Protector
Opti
or rock ing the container throughout the dose is essential for proper operation as this insures uniform exposure of all water to germicidal UV light.
Cold Weather Considerations
Bri ng Protector
Opti
up to a temperature above 32°F/0°C before using. B attery performance may be adversely affected by cold weather.
Lamp Life
Lamp Life = 8,000 Treatments, lamps must be replaced by manufacturer or SteriPEN® technician.
Hydro-Photon, Inc.
PO Box 675
262 Ellsworth Road
Blue Hill, ME 04614 USA
Toll Free USA: 1-888-SteriPEN
(+1) 207-374-5800
info@steripen.com
www.steripen.com PRO.UG.1106
SteriPEN® Protector
Opti
User’s Guide
Instructions for Using SteriPEN® Protector
Opti
Operating Signals
Green, fast flashing (after button push)
Green, slow flashing: 1 second on, 1 second off (after dose completion)
Green, steady (after dose completion)
Green blinks for 15 seconds followed by a quick Red flash
Red, steady
Battery Warnings
Red, fast flashing
Green slow blinking with Red flashes
Green, steady with Red flashes
LED will not come on
Lamp Warnings
Red 2 flashes, Green 2 flashes (repeating)
Red 3 flashes, Green 1 flash (repeating)
Normal indicator LED function, yet UV lamp emits no visible light
No LED indicator and UV lamp emits no visible light
Unit is armed and ready to treat water
32 fl. oz. (1 L) dose completed
16 fl. oz. (0.5 L) dose completed
Time expired, try again. The user has 15 seconds to put the SteriPEN
®
purifier in water after activation. Dose incomplete. Repeat treatment.
Low battery warning; replace or recharge batteries
32 fl. oz. (1 L) dose completed; low battery
16 fl. oz. (0.5 L) dose completed; low battery
(1) Check battery orientation (2) Charge or replace batteries (3) Clean battery contacts (4) Return SteriPEN
®
purifier for repair
Over 7,900 treatments completed; lamp replacement needed in under 100 doses
Lamp failure; replace lamp
Lamp failure. Do not consume water.
Battery issue or Lamp failure; Try fresh batteries, then contact support
SteriPEN® Protector
Opti
LED (Light Emitting Diode) Signals
LED Color and Pattern Display Indication
SteriPEN® Protector treats two ranges of water volume: A—between 0.5 – 1 L (16 – 32 fl. oz.)
B—up to 0.5 L (16 fl. oz.)
1
Install two CR123 batteries with polarities as
shown; or install one double-cell CR123 battery. Tighten coin screw on battery end cap until snug (do NOT over-tighten screw as this may cause damage).
2 Remove lamp cover – pull cover off body.
3A Push Activation button once – green indicator LED
(near button) and white optical sensor (near lamp) will flash for up to 15 seconds indicating Protector is ready to treat up to 1 liter (32 fl. oz.).
3B Push Activation button twice – green indicator LED
(near button) and white optical sensor (near lamp) will flash for up to 15 seconds indicating Protector is ready to treat up to .5 liter (16 fl. oz.).
4 While green indicator LED and white optical sensor
flashes, dip the ultraviolet (UV) lamp into the water to be treated such that lamp and optical sensor are completely immersed. When water is detected, lamp turns on automatically, emitting both UV and visible light. IMPORTANT NOTE: If visible light from UV lamp is not evident, the Protector UV lamp is not on, and water should not be consumed.
5 Agitate the water throughout the dose by stirring with
the Protector until the lamp automatically turns off. Once lamp turns off, green indicator LED will turn on to show that the UV dose is complete. NOTE: If red LED turns on after lamp shuts off, the dose was not complete.
6 Remove Protector from water. Dry off lamp and opti-
cal water sensor with clean cloth. IMPORTANT NOTE: Many brands of CR123 batteries have built-in protec­tion circuitry that instantly disables battery function when batteries reach a specific low charge threshold. If this “disable” function is triggered during operation the Protector will be unable to give the “Low Battery” signal (blinking red LED). Until batteries are replaced or recharged the Protector will not be operational.
7 To activate the flashlight, press and hold the activa-
tion button for 3 seconds. The flashlight will automati­cally be on for 3 minutes; reactivate as needed. To turn off the flashlight, push the activation button once. To protect UV lamp when using the flashlight, operate with lamp cover in place.
Quick Start Guide
Use SteriPEN® Protector
Opti
with clear water. Discolored or dirty water should be pre-filtered until clear prior to SteriPEN® Protector treatment. See also “Treating Turbid, Murky, or Cloudy Water.”
2
3
1
4
5
6
7
1
2
3
4
5
6
7
Guide to SteriPEN® Protector
Opti
Parts
1) UV Lamp Cover
2) UV Lamp Assembly
3) Optical Water Sensor & LED for flashlight
4) Activation Button
5) Indicator LED (Light Emitting Diode): shows activation status
6) Battery Compartment End Cap
7) Battery Compartment End Cap Screw
If viewing 3 3 ntu water in a clear 1 liter bottle, one might characterize the water as follows: Much closer to clear than opaque, Obviously not clear,
Obviously cloudy, Objects viewed through the water are visible but blurry, As cloudy as weak lemonade.
Care and Cleaning
When not in use, Protector
Opti
should be kept in a clean, dry, non-ab rasive
area or container. Protector
Opti
should not be exposed to ambient temperatures above 140°F/60°C or below -4°F/-20°C. When storing Protector
Opti
for long periods, remove batteries.
To clea n Protector
Opti
, wash with a soft cloth and a mild soap solution. Rinse soap from device and dry with a clean, soft cloth. Note that while the battery compartment of Protector
Opti
is designed to be water resistant, it is not
guaran teed t o be i mpermeable and should therefore never be submerged.
Troubleshooting
If flashing green indicator LED (Light Emitting Diode) shows that Protector
Opti
is armed, but the lamp does not light when immersed in water, check to be sure UV lamp and optical sensor is completely immersed.
If fresh batteries have been installed, but low battery LED warning appea rs, low battery temperature may be the cause. Remove batteries from device and warm them (i.e. in your pocket).
If after initiating a dose, UV lamp shuts off and indicator LED does not co me on at all, the batteries may be drained and in need of replacement or charging. See “IMPORTANT NOTE” in Battery Selection section.
Technical Support
For technical support, please contact Hydro-Photon, Inc. via phone: (+1) 207-374-5800; USA: 1-888-SteriPEN or email: support@steripen.com.
Repair Information
Any repairs to your Protector
Opti
should be done by a SteriPEN technici an. For repairs, contact Hydro-Photon directly at info@steripen.com or 1-888-SteriPEN; (+1) 207-374-5800. For additional troubleshooting and repair information, visit www.steripen.com
Product Registration & Warranty Information
Hydro-Photon, Inc. provides a limited warranty such that the enclosed SteriPEN Defender is under warranty for any manufacturing defect for whichever situation occurs first: (1) the life (8,000 treatments) of the UV lamp or (2) three years from date of purchase. Warranty will be voided if SteriPEN Defender is (a) altered in any way, (b) used for purposes inconsistent with product’s intended function, or (c) if product instructions and warnings are not followed.
For product registration and complete warranty information, please visit www. steripen.com/support or contact Hydro-Photon Inc. at (+1) 207.374.5800 or info@ steripen.com.
Warnings for Safe Use
• Improper operation of Protector
Opti
may cause injury. Read and understand all
warnings prior to operating Protector
Opti
.
• As with any water treatment system, you should always have a backup method and an extra set of fresh batteries available.
• Do not allow water to enter Protector
Opti
through the battery compartment. While the battery compartment seal is designed to be water resistant, it is not guaranteed to be impermeable.
• Do not submerge the battery compartment end of the device.
• Do not operate
Protector
Opti
in quartz containers such as quartz laboratory beakers.
Protector
Opti
should not be used by children.
Protector
Opti
is a high voltage device. Removal or tampering with the electronic
circuit board or lamp assembly may cause personal injury, or damage Protector
Opti
.
• Do not open, expose, modify or touch internal circuitry; this can lead to high voltage
shock.
• Do not attempt to bypass optical sensor: this is an important safety feature.
Protector
Opti
is not intended to disinfect surfaces of a drinking container, i.e. those that typically contact the mouth when drinking. Be certain that your drinking contain er has been properly cleaned/washed prior to using
Protector
Opti
.
Protector
Opti
is not intended to disinfect water above the surface of the water in the container, i.e., droplets of water suspended on the side of the glass. Remove/dry these droplets prior to drinking.
Protector
Opti
is intended for use with clear water but in emergencies may be used in moderately turbid water. See “Treating Turbid, Murky or Cloudy Water” section above before deciding to use SteriPEN
®
on turbid water.
Protector
Opti
is designed to treat 0.5 or 1.0 liter (16 or 32 fl. oz.) of cle ar water. I f in doubt about volume of wat er to b e treat ed, confirm volume with a measuring device such as a measuring cup.
• Do not store Protector
Opti
for long periods with batteries installed. Batteries may in
rare instances leak or corrode and cause damage to device.
• When operating properly, the Protector
Opti
’s UV lamp will emit visible light as well as UV. If UV lamp is not em itting v isible light, it is not functioning properly, and should not be used until repaired.
• The Protector
Opti
lamp assembly must be clean prior to use.
• If Protector
Opti
is below 32°F/0°C it should be warmed above 32°F/0°C before
operating.
• Do not allow impact to the lamp end. If lamp assembly (lamp or quartz sleeve) is
cracked, chipped or damaged, do not operate. Return to your local distributor/ importer for repair.
• Do not use in liquids other than clear water.
• Do not use in water with ice.
• Do not use in water above 140°F/60°C.
• UV light can be harmful to eyes and skin. Never look at an unshielded UV lamp
during operation.
• Do not operate near skin.
• Do not operate near eyes.
• Do not insert into bodily orifices.
• While carefully controlled microbiological testing has been conducted, use of
Protector
Opti
in non-laboratory conditions may produce results that vary from our
laboratory test data.
• Do not use in any manner other than instructed in this User’s Guide.
• Like most fluorescent-type lamps, the
Protector
Opti
lamp contains a small amount of
mercury. Please return your Protector
Opti
at the end of its productive life to your
distributor/importer to permit correct recycling or safe disposal.
Certifications & Patents
Conforms to EN61010-1:1993 + A1 + A2 and EN 61326 Listed 3058969. Conforms to Standard UL 61010A-1 Certified to CAN/CSA Standard C22.2, No. 1010.1-92 U.S.E.P.A. Company #73679, U.S. EPA Establishment #07369-ME-001 U.S. Patent Numbers 5,900,212 & 6,110,424 & 6,579,495 Patents and patents pending in U.S. and worldwide.
SteriPEN® is a registered trademark of Hydro-Photon, Inc. © 2011 Hydro-Photon, Inc. All rights reserved.
www.steripen.com
Battery Selection & Installation
SteriPEN® Protector
Opti
uses two CR123 batteries. CR123 batteries are nominally 3 volts and are available in both rechargeable and non­rechargeable (disposable) varieties. One double-cell CR123 battery may also be used.
Use high quality name brand batteries. Our testing has shown that a single set of non-rechargeable (disposable) CR123’s will treat approximately 50 liters of water. Testing on rechargeable CR123’s (650mAh) indicates that approximately 30 liters may be treated between battery charges.
Cold ambient temperatures may reduce the number of doses available from batteries. To maximize available battery power keep your batteries in a warm place (i.e. your pocket) when in cold weather conditions.
To replace batteries, loosen screw in battery end cap with a coin and then remove end cap (see diagram 2). Install new or recharged batteries with battery polarity as shown—positive ends of batteries facing out, toward battery compartment end cap (see diagram 1). Replace the battery end cap and tighten screw until snug. Do not over tighten screw as this may damage the device.
Note that if you will be storing your SteriPEN® Protector
Opti
for a long period of time, it is best to remove the batteries from the device. As with all high­tech devices, the batteries must be removed when storing the unit. This will reduce/prevent battery terminal corrosion, spring fatigue and batteries from draining.
IMPORTANT NOTE: Many brands of CR123 batteries have built-in protection circuitry that instantly disables battery function when batteries reach a specific low charge threshold. If this “disable” function is triggered during operation the Protector
Opti
will be unable to give the “Low Battery” signal
(blinking red LED). Until batteries are replaced or recharged the Protector
Opti
will not be operational.
To replace batteries, remove the battery end cap. Install new batteries in the end cap with polarities as shown. Re-install end cap.
Treating Turbid, Murky or Cloudy Water
SteriPEN
®
Protector
Opti
is intended for use, and is most effective, in cl ear water . However, SteriPEN® has been shown to reduce microbial contamination in turbid water. If clear water is not available, first try to filter the water to clarify it– use a SteriPEN pre-filter, coffee filter or clean cloth. If it is necessary to treat turbid, murky or cloudy water in an emergency situation, use SteriPEN® as follows:
• To treat 1 liter of turbid water, use two one-liter treatments.
To accomplish this, push the operating button one time and complete the first treatment. Remove unit from water. Then push the button one time again and complete the second treatment.
• To treat 0.5 liters of turbid water, use a single 1 liter dose.
To accomplish this, push the operating button once and complete the treatment.
Turbidity is a measure of water clarity as effected by the presence of suspended solids. As turbidity increases, the suspended solids and murkines s of the water also increase. It is difficult to communicate a particular level of turbidity with just a written description. Accordingly, please take into account the following when considering the use of SteriPEN® in water that is not clear: Laboratory testing has shown that SteriPEN
®
is effective in water with a turbidity of not less than 30 ntu (Nephelometric Turbidit y Units) as described in the U.S. EPA Guide Standard and Protocol for Testing Microbiological Water Purifiers, section 3.3.4. SteriPEN
®
has
been successfully tested in water with a turbidity measurement of 33 ntu.
SteriPEN® is tested and certified by the Water Quality Association against the US EPA Microbiological Water Purifier Standard.
PROPERLY REPLACING BATTERIES