If viewing 3 3 ntu water in a clear 1 liter bottle, one might characterize the
water as follows: Much closer to clear than opaque, Obviously not clear,
Obviously cloudy, Objects viewed through the water are visible but blurry, As
cloudy as weak lemonade.
Care and Cleaning
When not in use, Protector
Opti
should be kept in a clean, dry, non-ab rasive
area or container. Protector
Opti
should not be exposed to ambient
temperatures above 140°F/60°C or below -4°F/-20°C. When storing
Protector
Opti
for long periods, remove batteries.
To clea n Protector
Opti
, wash with a soft cloth and a mild soap solution. Rinse
soap from device and dry with a clean, soft cloth. Note that while the battery
compartment of Protector
Opti
is designed to be water resistant, it is not
guaran teed t o be i mpermeable and should therefore never be submerged.
Troubleshooting
If flashing green indicator LED (Light Emitting Diode) shows that Protector
Opti
is armed, but the lamp does not light when immersed in water, check to be
sure UV lamp and optical sensor is completely immersed.
If fresh batteries have been installed, but low battery LED warning appea rs, low
battery temperature may be the cause. Remove batteries from device and
warm them (i.e. in your pocket).
If after initiating a dose, UV lamp shuts off and indicator LED does not co me on
at all, the batteries may be drained and in need of replacement or charging.
See “IMPORTANT NOTE” in Battery Selection section.
Technical Support
For technical support, please contact Hydro-Photon, Inc. via phone:
(+1) 207-374-5800; USA: 1-888-SteriPEN or email: support@steripen.com.
Repair Information
Any repairs to your Protector
Opti
should be done by a SteriPEN technici an.
For repairs, contact Hydro-Photon directly at info@steripen.com or
1-888-SteriPEN; (+1) 207-374-5800. For additional troubleshooting and repair
information, visit www.steripen.com
Product Registration & Warranty Information
Hydro-Photon, Inc. provides a limited warranty such that the enclosed SteriPEN
Defender is under warranty for any manufacturing defect for whichever situation
occurs first: (1) the life (8,000 treatments) of the UV lamp or (2) three years from
date of purchase. Warranty will be voided if SteriPEN Defender is (a) altered in
any way, (b) used for purposes inconsistent with product’s intended function, or
(c) if product instructions and warnings are not followed.
For product registration and complete warranty information, please visit www.
steripen.com/support or contact Hydro-Photon Inc. at (+1) 207.374.5800 or info@
steripen.com.
Warnings for Safe Use
• Improper operation of Protector
Opti
may cause injury. Read and understand all
warnings prior to operating Protector
Opti
.
• As with any water treatment system, you should always have
a backup method and an extra set of fresh batteries available.
• Do not allow water to enter Protector
Opti
through the battery compartment. While
the battery compartment seal is designed to be water resistant, it is not guaranteed
to be impermeable.
• Do not submerge the battery compartment end of the device.
• Do not operate
Protector
Opti
in quartz containers such as quartz laboratory beakers.
• Protector
Opti
should not be used by children.
•
Protector
Opti
is a high voltage device. Removal or tampering with the electronic
circuit board or lamp assembly may cause personal injury, or damage Protector
Opti
.
• Do not open, expose, modify or touch internal circuitry; this can lead to high voltage
shock.
• Do not attempt to bypass optical sensor: this is an important safety feature.
•
Protector
Opti
is not intended to disinfect surfaces of a drinking container, i.e.
those that typically contact the mouth when drinking. Be certain that your drinking
contain er has been properly cleaned/washed prior to using
Protector
Opti
.
•
Protector
Opti
is not intended to disinfect water above the surface of the water in the
container, i.e., droplets of water suspended on the side of the glass. Remove/dry
these droplets prior to drinking.
• Protector
Opti
is intended for use with clear water but in emergencies may be used
in moderately turbid water. See “Treating Turbid, Murky or Cloudy Water” section
above before deciding to use SteriPEN
®
on turbid water.
•
Protector
Opti
is designed to treat 0.5 or 1.0 liter (16 or 32 fl. oz.) of cle ar water. I f in doubt
about volume of wat er to b e treat ed, confirm volume with a measuring device such as a
measuring cup.
• Do not store Protector
Opti
for long periods with batteries installed. Batteries may in
rare instances leak or corrode and cause damage to device.
• When operating properly, the Protector
Opti
’s UV lamp will emit visible light as well
as UV. If UV lamp is not em itting v isible light, it is not functioning properly, and
should not be used until repaired.
• The Protector
Opti
lamp assembly must be clean prior to use.
• If Protector
Opti
is below 32°F/0°C it should be warmed above 32°F/0°C before
operating.
• Do not allow impact to the lamp end. If lamp assembly (lamp or quartz sleeve) is
cracked, chipped or damaged, do not operate. Return to your local distributor/
importer for repair.
• Do not use in liquids other than clear water.
• Do not use in water with ice.
• Do not use in water above 140°F/60°C.
• UV light can be harmful to eyes and skin. Never look at an unshielded UV lamp
during operation.
• Do not operate near skin.
• Do not operate near eyes.
• Do not insert into bodily orifices.
• While carefully controlled microbiological testing has been conducted, use of
Protector
Opti
in non-laboratory conditions may produce results that vary from our
laboratory test data.
• Do not use in any manner other than instructed in this
User’s Guide.
• Like most fluorescent-type lamps, the
Protector
Opti
lamp contains a small amount of
mercury. Please return your Protector
Opti
at the end of its productive life to your
distributor/importer to permit correct recycling or safe disposal.
Certifications & Patents
Conforms to EN61010-1:1993 + A1 + A2 and EN 61326
Listed 3058969. Conforms to Standard UL 61010A-1
Certified to CAN/CSA Standard C22.2, No. 1010.1-92
U.S.E.P.A. Company #73679, U.S. EPA Establishment #07369-ME-001 U.S.
Patent Numbers 5,900,212 & 6,110,424 & 6,579,495
Patents and patents pending in U.S. and worldwide.
SteriPEN® is a registered trademark of Hydro-Photon, Inc.
© 2011 Hydro-Photon, Inc. All rights reserved.
www.steripen.com
Battery Selection & Installation
SteriPEN® Protector
Opti
uses two CR123 batteries. CR123 batteries are
nominally 3 volts and are available in both rechargeable and nonrechargeable (disposable) varieties. One double-cell CR123 battery may also
be used.
Use high quality name brand batteries. Our testing has shown that a single
set of non-rechargeable (disposable) CR123’s will treat approximately 50
liters of water. Testing on rechargeable CR123’s (650mAh) indicates that
approximately 30 liters may be treated between battery charges.
Cold ambient temperatures may reduce the number of doses available from
batteries. To maximize available battery power keep your batteries in a warm
place (i.e. your pocket) when in cold weather conditions.
To replace batteries, loosen screw in battery end cap with a coin and then
remove end cap (see diagram 2). Install new or recharged batteries with
battery polarity as shown—positive ends of batteries facing out, toward
battery compartment end cap (see diagram 1). Replace the battery end cap
and tighten screw until snug. Do not over tighten screw as this may
damage the device.
Note that if you will be storing your SteriPEN® Protector
Opti
for a long period
of time, it is best to remove the batteries from the device. As with all hightech devices, the batteries must be removed when storing the unit. This will
reduce/prevent battery terminal corrosion, spring fatigue and batteries from
draining.
IMPORTANT NOTE: Many brands of CR123 batteries have built-in protection
circuitry that instantly disables battery function when batteries reach a
specific low charge threshold. If this “disable” function is triggered during
operation the Protector
Opti
will be unable to give the “Low Battery” signal
(blinking red LED). Until batteries are replaced or recharged the Protector
Opti
will not be operational.
To replace batteries, remove the battery end cap. Install new batteries in the
end cap with polarities as shown. Re-install end cap.
Treating Turbid, Murky or Cloudy Water
SteriPEN
®
Protector
Opti
is intended for use, and is most effective, in cl ear water .
However, SteriPEN® has been shown to reduce microbial contamination
in turbid water. If clear water is not available, first try to filter the water
to clarify it– use a SteriPEN pre-filter, coffee filter or clean cloth. If it is
necessary to treat turbid, murky or cloudy water in an emergency situation,
use SteriPEN® as follows:
• To treat 1 liter of turbid water, use two one-liter treatments.
To accomplish this, push the operating button one time and complete the
first treatment. Remove unit from water. Then push the button one time
again and complete the second treatment.
• To treat 0.5 liters of turbid water, use a single 1 liter dose.
To accomplish this, push the operating button once and complete the
treatment.
Turbidity is a measure of water clarity as effected by the presence of
suspended solids. As turbidity increases, the suspended solids and murkines s
of the water also increase. It is difficult to communicate a particular
level of turbidity with just a written description. Accordingly, please take
into account the following when considering the use of SteriPEN® in water
that is not clear: Laboratory testing has shown that SteriPEN
®
is effective
in water with a turbidity of not less than 30 ntu (Nephelometric Turbidit y
Units) as described in the U.S. EPA Guide Standard and Protocol for
Testing Microbiological Water Purifiers, section 3.3.4. SteriPEN
®
has
been successfully tested in water with a turbidity measurement of 33 ntu.
SteriPEN® is tested and certified by the
Water Quality Association against the US EPA
Microbiological Water Purifier Standard.
PROPERLY REPLACING BATTERIES