Stelp ASIL15, ASIL20, ASIL05, ASIL25, ASILH07 User Manual

...
INSASIL0314
For further information or to consult this guide online, please visit our website at www.stelpro.com
S
Y
S
T
È
M
Q
U
A
L
I
T
C
E
R
T
I
F
I
É
-
R
E
G
I
S
T
E
R
E
D
Q
U
A
L
I
T
Y
S
Y
S
T
E
M
This unit complies with CSA and UL standards
USER’S GUIDE
ASIL SERIES
ELECTRONIC CONVECTOR
REPLACEMENT COMPONENT LIST INCLUDED
8
INSASIL0314
STELPRO DESIGN INC. | Saint-Bruno-de-Montarville | Quebec | J3V 6L7
This limited warranty is offered by Stelpro Design inc. (“Stelpro”) and applies to the following product made by Stelpro: ASIL model. Please read this limited warranty carefully. Subject to the terms of this warranty, Stelpro warrants its products and their components against defects in
workmanship and/or materials for the following periods from the date of purchase: 5 years (3 years on electronic components). This warranty applies only to the original purchaser; it is non-transferable and cannot be extended.
CLAIM PROCEDURE
If at any time during the warranty period the unit becomes defective, you must cut off the power supply at the main electrical panel and contact 1) your installer or distributor, 2) your service center or 3) Stelpro’s customer service department. In all cases, you must have a copy of the invoice and provide the information written on the product nameplate. Stelpro reserves the right to examine or to ask one of its representatives to examine the product itself or any part of it before honoring the warranty. Stelpro reserves the right to replace the entire unit, refund its purchase price or repair a defective part. Please note that repairs made within the warranty period must be authorized in advance in writing by Stelpro and carried out by persons authorized by Stelpro.
Before returning a product to Stelpro, you must have a Stelpro authorization number (RMA). To obtain it, call the customer service department at: 1-800-363-3414 (electricians and distributors - French), 1-800-343-1022 (electricians and distributors - English), or 1-866-766-6020 (consumers). The authorization number must be clearly written on the parcel or it will be refused.
CONDITIONS, EXCLUSIONS AND DISCLAIMER OF LIABILITY
This warranty is exclusive and in lieu of all other representations and warranties (except of title), expressed or implied, and Stelpro expressly disclaims
and excludes any implied warranty of merchantability or implied warranty of fi tness for a particular purpose.
Stelpro’s liability with respect to products is limited as provided above. Stelpro shall not be subject to any other obligations or liabilities whatsoever, whether based on contract, tort or other theories of law, with respect to goods or services furnished by it, or any undertakings, acts or omissions relating thereto. Without limiting the generality of the foregoing, Stelpro expressly disclaims any liability for property or personal injury damages,
penalties, special or punitive damages, damages for lost profi ts, loss of use of equipment, cost of capital, cost of substitute products, facilities or
services, shutdowns, slowdowns, or for other types of economic loss or for claims of a dealer’s customers or any third party for such damages. Stelpro
specifi cally disclaims all consequential, incidental and contingent damages whatsoever.
This warranty does not cover any damages or failures resulting from: 1) a faulty installation or improper storage; 2) an abusive or abnormal use, lack of maintenance, improper maintenance (other than that prescribed by Stelpro) or a use other than that for which the unit was designed; 3) a natural
disaster or an event out of Stelpro’s control, including, but not limited to, hurricanes, tornadoes, earthquakes, terrorist attacks, wars, overvoltage, fl ooding, water damages, etc. This warranty does not cover any accidental or intentional losses or damages, nor does it cover damages caused by
negligence of the user or owner of the product. Moreover, it does not cover the cost of disconnection, transport, and installation.
The warranty is limited to the repair or the replacement of the unit or the refund of its purchase price, at the discretion of Stelpro. Any parts replaced or repaired within the warranty period with the written authorization of Stelpro will be warranted for the remainder of the original warranty period. This warranty will be considered null and void and Stelpro will have the right to refuse any claims if products have been altered without
the written authorization of Stelpro and if the nameplate numbers have been removed or modifi ed. This warranty does not cover scratches, dents,
corrosion or discoloration caused by excessive heat, chemical cleaning products and abrasive agents. It does not cover any damage that occurred during the shipping.
Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some of them do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you. This warranty gives you specifi c legal rights and you
may have other rights which vary from state to state or from province to province.
LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY
LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY
LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY
LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY LIMITED WARRANTY
LIMITED WARRANTY
2
INSASIL0314
Before installing and operating this product, the user and/or installer must read, understand and follow these instructions and keep them handy for future reference. If these instructions are not followed, the warranty will be considered null and void and the manufacturer deems no further responsibility for this product.
This product must be installed by a qualifi ed person and connected by a certifi ed electrician, according to the electrical and building codes effective in your region.
The following instructions must be adhered to in order to avoid personal injuries or property damages, serious injuries and potentially fatal electric shocks.
Protect the heating unit with the appropriate circuit breaker or fuse, in accordance with the nameplate.
Make sure the line voltage (volt) is consistent with that indicated on the unit’s nameplate.
This unit must be grounded.
Switch off the power at the circuit breaker/fuse before installing, repairing and cleaning the unit.
Make sure the unit is appropriate for the intended use (if needed, refer to the product catalog or a representative). Use this heater only as described in this
manual. Any other use not recommended by the manufacturer may cause fi re, electric shock, or injury to persons. Do not use outdoors.
RECOMMENDED HEATING CAPACITY:
1.25 W/cubic foot (0.03 m³)
It corresponds to 10 W/square foot (0.09 m²) based on a standard ceiling height of 8 feet (2.44 m). The recommended capacity is usually suffi cient for normal heating needs. Please note that the insulation quality of walls and windows are some of the factors that infl uence heat losses, which modify the required capacity to heat a room. If needed, refer to a specialist who will be able to calculate these heat losses and optimize the required capacity or
consult the “Online heating calculation” section of the Stelpro Design Web site (residential buildings). To heat a large room and to increase your comfort, it is recommended to install several units instead of one. For example, 2 X 1000 W rather than 1 X 2000 W.
Do not install the unit where objects or pieces of furniture could be heat damaged.
If the unit’s capacity is insuffi cient for the size of the room, it will be in operation continuously, and may become defective earlier and turn yellow.
Respect distances and positions indicated in the installation section.
If the installer or user modifi es the unit, they will be held responsible for any damage resulting from this modifi cation, and the CSA certifi cation could be void.
This unit must not come into contact with a water source and must be protected from splashes (e.g. a wet mop). Do not use it if any part has been immersed. Moreover, do not turn it on or off when standing in water or if your hands are wet.
When mounting the unit, make sure that the anchorage used can support the total weight of the unit with the mounting brackets.
When cutting or drilling into a wall, do not damage electrical wiring and other hidden utilities.
When starting up the unit for the fi rst time or after a long period, it is normal that it produces some temporary odours and whitish smoke.
Because this unit is hot when in use, it may pose risks even in normal operation. Therefore, be careful and responsible when using it. To avoid burns, do not let bare skin touch hot surfaces. Let the unit cool down for a few minutes before handling it (it stays warm for some time after shut-down). Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
The bottom of this unit must be installed at least 4 inches (10.2 cm) from any adjacent surfaces. However, make sure objects or pieces of furniture such as, but not limited to, pillows, bedding, blankets, towels, beds, laundry baskets, clothing, papers, curtains, etc., do not come into contact with the unit and keep them at least 3 feet (0.9 m) from the front of the heater and keep them away from the sides, since they are more fl ammable than walls and fl oors. Failure
to comply with this warning could lead to a fi re. Some materials are more heat-sensitive than others, so make sure those near the unit can withstand heat.
Do not install on a wall behind a door.
Never block air vents (with objects or other items). You risk damaging the heater and the obstruction could lead to electric shock or overheating, which could
result in a fi re.
Do not insert or allow foreign objects to enter any air vent as this may cause electric shocks, a fi re or damages to the unit.
This unit has hot and arcing or sparking parts inside. It is not designed to be used or stored in wet areas or areas containing fl ammable liquids, combustible materials or corrosive, abrasive, chemical, explosive and fl ammable substances such as, but not limited to, gasoline, paint, chlorine, sawdust and cleaning
products.
Some areas are dustier than others. Thus, it is the user’s responsibility to evaluate if the unit must be cleaned based on the amount of dirt accumulated on and inside air vents. Accumulated dirt can lead to a component malfunction or give a yellowish colour to unit. Failure to install and maintain unit in accordance
with these instructions poses a fi re hasard.
Thermal protection activation indicates that the unit has been subjected to abnormal operating conditions. If the thermal protection remains activated or
activates and deactivates repeatedly, it is recommended that a qualifi ed electrician or a certifi ed repair centre examine the unit in order to make sure it is not
damaged. (Refer to the limited warranty.)
Before unplugging the unit, all controls must be in the “OFF” position and the current from the main breaker panel should be cut. (The general switch may be
used also, if included.) If the unit is damaged or defective, discontinue use, cut off power supply at circuit breaker and contact a certifi ed electrician or certifi ed
repair centre. (Refer to the limited warranty)
This heater includes a visual alarm to warn that parts of the heater are getting excessively hot. If the alarm illuminates, immediately turn the heater off and
inspect for any objects on or adjacent to the heater that may have blocked the airfl ow or otherwise caused high temperatures to have occurred. DO NOT OPERATE THE HEATER WITH THE ALARM ILLUMINATED.
WARNING
Note: When a part of the product specifi cation must be changed to improve operability or other functions, priority is given to the product specifi cation itself. In such
instances, the instruction manual may not entirely match all the functions of the actual product. Therefore, the actual product and packaging, as well as the name
and illustration, may differ from the manual. The screen/LCD display shown as an example in this manual may be different from the actual screen/LCD display. This
unit must be used with the provided thermostat.
IMPORTANT INSTRUCTIONS
SAVE THESE INSTRUCTIONS
7
INSASIL0314
PROBLEM DEFECTIVE PART OR PART TO CHECK
Overheating
- Defective thermostat or wrong thermostat setting
The unit cycles under control of the thermal protection (overheat indicator)
- Blocked air vents
The heater is on and the breaker trips
- Faulty connections
- Voltage higher than that indicated on the nameplate
The unit does not heat
- One or more defective elements
N.B. If you do not solve the problem after checking these points, cut off the power supply at the main electrical panel and contact our customer service (please refer to the limited warranty to obtain the phone numbers)
* Add W for white, A for almond, SS for stainless steel
REPLACEMENT COMPONENT LIST
MODEL ENCLOSURE
FRONT COVER
FRONT
GRILL
WALL
BRACKET
ELEMENT
(TYPE X)
LINEAR THERMAL
PROTECTION
(AUTO.) (L220)
ELECTRONIC THERMOSTAT
PERFORATED
JUNCTION
BOX COVER
PILOT LIGHT
250V (RED)
1 2 3 4 5 6 7 8 9
ASIL05 M-SIL0500A* M-SIL0513Z* M-SIL0500B* M-SIL0500C0 ELF-SILH0508X PROT-185
ST-214 M-ASIL12Z1 PL-240
ASIL07 M-SIL0700A* M-SIL0713Z* M-SIL0700B* M-SIL0500C0 ELF-SIL0708X PROT-185
ASIL10 M-SIL1000A* M-SIL1013Z* M-SIL1000B* M-SIL1000C0 ELF-SIL1008X PROT-186
ASIL12 M-SIL1200A* M-SIL1213Z* M-SIL1200B* M-SIL1000C0 ELF-SIL1208X PROT-186
ASIL15 M-SIL1500A* M-SIL1513Z* M-SIL1500B* M-SIL1000C0 ELF-SIL1508X PROT-186
ASIL17 M-SIL1700A* M-SIL1713Z* M-SIL1700B* M-SIL1000C0 ELF-SIL1708X PROT-179
ASIL20 M-SIL2000A* M-SIL2013Z* M-SIL2000B* M-SIL2000C0 ELF-SIL2008X PROT-179
ASIL25 M-SIL2500A* M-SIL2513Z* M-SIL2500B* M-SIL2000C0 ELF-SIL2508X PROT-180
ASIL30 M-SIL3000A* M-SIL3013Z* M-SIL3000B* M-SIL2000C0 ELF-SIL3008X PROT-180
ASILH07 M-SILH0700A* M-SILH0713Z* M-SILH0700B* M-SILH0700C0 ELF-SILH0708X PROT-185
ASILH10 M-SILH1000A* M-SILH1013Z* M-SILH1000B* M-SILH1000C0 ELF-SILH1008X PROT-185
ASILH12 M-SILH1200A* M-SILH1213Z* M-SILH1200B* M-SILH1200C0 ELF-SILH1208X PROT-186
ASILH15 M-SILH1500A* M-SILH1513Z* M-SILH1500B* M-SILH1200C0 ELF-SILH1508X PROT-186
ASILH17 M-SILH1700A* M-SILH1713Z* M-SILH1700B* M-SILH1200C0 ELF-SILH1708X PROT-179
ASILH20 M-SILH2000A* M-SILH2013Z* M-SILH2000B* M-SILH2000C0 ELF-SILH2008X PROT-179
ASILH25 M-SILH2500A* M-SILH2513Z* M-SILH2500B* M-SILH2000C0 ELF-SILH2508X PROT-187
ASILH30 M-SILH3000A* M-SILH3013Z* M-SILH3000B* M-SILH2000C0 ELF-SILH3008X PROT-180
ASILL07 M-SILL0700A* M-SILL0713Z* M-SILL0700B* M-SILL0700C0 ELF-SILL0708X PROT-185
ASILL10 M-SILL1000A* M-SILL1013Z* M-SILL1000B* M-SILL0700C0 ELF-SILL1008X PROT-186
ASILL12 M-SILL1200A* M-SILL1213Z* M-SILL1200B* M-SILL0700C0 ELF-SILL1208X PROT-186
ASILL15 M-SILL1500A* M-SILL1513Z* M-SILL1500B* M-SILL0700C0 ELF-SILL1508X PROT-179
ASILL17 M-SILL1700A* M-SILL1713Z* M-SILL1700B* M-SILL0700C0 ELF-SILL1708X PROT-179
ASILL20 M-SILL2000A* M-SILL2013Z* M-SILL2000B* M-SILL2000C0 ELF-SILL2008X PROT-187
ASILL25 M-SILL2500A* M-SILL2513Z* M-SILL2500B* M-SILL2000C0 ELF-SILL2508X PROT-180
ASILL30 M-SILL3000A* M-SILL3013Z* M-SILL3000B* M-SILL2000C0 ELF-SILL3008X PROT-181
2
5
1
4
7
6
3
9
8
TROUBLESHOOTING & REPLACEMENT COMPONENT LIST
3
INSASIL0314
TECHNICAL DRAWINGS
Add W for white, A for almond or SS for stainless steel (1000 W, 1500 W and 2000 W models only) Thermostat included
SPECIFICATIONS
TYPE WATTS VOLTS
LENGTH
MM IN. KG LB
HIGH MODELS - HEIGHT : 648 mm (25 1/2 in.)
ASILH07 750/560 240/208 419 16 1/2 7.38 16.27
ASILH10 1000/750 240/208 457 18 7.94 17.5
ASILH12 1250/940 240/208 559 22 9.41 20.75
ASILH15 1500/1125 240/208 673 26 1/2 11.04 24.34
ASILH17 1750/1315 240/208 743 29 1/4 12.02 26.5
ASILH20 2000/1500 240/208 819 32 1/4 13.22 29.15
ASILH25 2500/1875 240/208 978 38 1/2 15.21 33.54
ASILH30 3000/2250 240/208 1143 45 17.52 38.63
LOW MODELS - HEIGHT : 330 mm (13 in.)
ASILL07
750/560
240/208 654 25 3/4 6.88 15.16
ASILL10
1000/750
240/208 724 28 1/2 7.55 16.64
ASILL12
1250/940
240/208 800 31 1/2 8.28 18.25
ASILL15
1500/1125
240/208 940 37 9.63 21.23
ASILL17
1750/1315
240/208 997 39 1/4 10.18 22.44
ASILL20
2000/1500
240/208 1086 42 3/4 11.24 24.77
ASILL25
2500/1875
240/208 1245 49 12.60 27.79
ASILL30
3000/2250
240/208 1410 55 1/2 14.18 31.27
STANDARD MODELS - HEIGHT : 440 mm (17 3/8 in.)
ASIL05
500/375
240/208 457 18 6.11 13.46
ASIL07
750/560
240/208 527 20 3/4 6.89 15.2
ASIL10
1000/750
240/208 597 23 1/2 7.75 17.08
ASIL12
1250/940
240/208 673 26 1/2 8.6 18.97
ASIL15
1500/1125
240/208 743 29 1/4 9.39 20.7
ASIL17
1750/1315
240/208 819 32 1/4 10.25 22.59
ASIL20
2000/1500
240/208 895 35 1/4 11.25 24.8
ASIL25
2500/1875
240/208 1054 41 1/2 12.76 28.14
ASIL30
3000/2250
240/208 1257 49 1/2 15.13 33.36
SPECIFICATIONS & TECHNICAL DRAWINGS
DEVANT
3 15/16" 101mm
MIN.
LONGUEUR
O
7/8" 22mm
KO
13 1/4" [338mm] SIL
8 15/16'' [227mm] SILL
21 7/16'' [545mm] SILH
1 5/16" 34mm
1 1/16" 26mm
CONNECTEUR ÉLECTRIQUE
2 15/16" 75mm
f f
f
f
CÔTÉ
1 3/16" 31mm
3 3/16" 80mm
3 15/16" 100mm
17 7/16" [440mm] SIL
13'' [330mm] SILL
25 1/2'' [648mm] SILH
6
INSASIL0314
In order to obtain a precise and optimal ambient temperature reading,
the unit must operate on a regular basis, i.e. without signifi cant
temperature variation for at least an hour. (This amount of time
increases if a temperature change of more than 4 degrees is requested.
Add approximately 15 minutes for every degree above 4).
ANTIFREEZE PROTECTION
In order to protect your home against freezing and limit energy consumption during long absences, put the thermostat on ANTIFREEZE
mode. To enter this mode, lower the day temperature to between 3°C and 5°C. A snowfl ake icon
( ) is displayed. This icon indicates that the
economic and secure ANTIFREEZE mode is on.
THE OFF MODE
To turn the unit off, you must lower the day temperature to less than
3°C. The inscription “OFF” is displayed (note that there is still electrical
current to the unit, meaning that there is a risk of electrical shock).
WITH AN ELECTRONIC WALL THERMOSTAT
This unit has been designed to be used with the electronic wall thermostat included in the box.
PRECISE ELECTRONIC CONTROL
Equipped with a proportional tension variation, the thermostat maintains a precise temperature, thus increasing your comfort level. The elimination of temperature fl uctuations combined with the use of the programmed heat lowering function (PT model) allows for energy savings.
COMPLETE FACTORY INSTRUCTIONS FOR TE AND PT THERMOSTATS ARE INCLUDED IN THEIR RESPECTIVE PACKAGING .
All other repairs and maintenance other than those described in
this guide should be performed by qualifi ed service per sonnel. In
order for the warranty to be valid, the unit must be cleaned regu­larly. Cut off power supply at circuit breaker/fuse and wait for the unit to cool down before cleaning.
Use a soft rag for dusting. When cleaning, use only a damp rag and non-abrasive dish soap. Do not use abrasive or chemical cleaners
because they may damage the fi nishing. If the unit is used in a very
dusty location, use a vacuum brush to remove dust and other foreign objects from the grilles. Note that cigarette smoke could yellow the discharge grille and that the best way to prevent it is to clean the unit on a regular basis.
Do not use cleaning products identifi ed with these symbols:
N.B. Note that there is electrical current linked to the unit even if the thermostat is set off. This means that there is a risk of electric shock as long as the unit is energized.
STAINLESS STEEL CLEANING TIPS
Although stainless steel is, by its very nature, corrosion resistant, its
fi nish is not foolproof. The key to maintaining a nice stainless steel fi nish is preventive cleaning. Clean the metal when it is dirty; do not wait until a full cleaning is required. Since the acidity level and the
chlorine content of regular cleaning agents vary greatly, it is highly recommended to thoroughly rinse the surface with clean water. Alternatively, you can use a stainless steel cleaner or clean water and dish soap. Always follow polish lines.
DO NOT USE
- chlorine
- scrubbing pads or similar scrubbing devices (steel wool)
- abrasive cleaning agents
- hydrochloric acid products such as bleach: they can stain and/or damage stainless steel surfaces
PROBLEM DEFECTIVE PART OR PART TO CHECK
The unit does not work
- Defective thermostat or wrong thermostat setting
- Open circuit breaker or fuse
- Thermal protection activated
- Faulty connections
The unit runs continuously
- Defective thermostat or wrong thermostat setting
- Heat losses greater than the unit capacity
The enclosure is extremely hot
- Defective thermal protection
- Blocked air vents
The desired room temperature cannot be reached
- One or more defective elements
- Defective thermostat or wrong thermosat setting
- Voltage lower than indicated on the nameplate
- Heat losses greater than the unit capacity
MAINTENANCE
TROUBLESHOOTING
OPERATION, MAINTENANCE & TROUBLESHOOTING
IMPORTANT - LIGHT
Activation of the thermal protection is indicated by a light located at the right end, visible trough the louvers. It warns you that the heater has been
subjected to abnormal conditions. If this occurs, it is highly recommended that the unit be disconnected and inspected by a qualifi ed electrician
in order to make sure it is not damaged.
4
INSASIL0314
INSTALLATION OF THE WALL RACK
1. Remove the unit from the wall rack’s hooks.
2. With a pencil, mark the wall at the four anchoring points of the rack.
3. Fasten the rack to the wall, making sure it is level. When drilling into a wall or ceiling, be careful not to damage electrical wiring and other hidden utilities.
N.B. The wall on which the convector will be installed must be straight in order for the wall rack to lie perfectly
fl at without any pressure points. Otherwise, brackets could malfunction.
INSTALLATION OF THE UNIT TO THE WALL RACK
1. Insert the bottom hooks of the rack into the unit.
2. Tip the top of the unit toward the wall.
3. Latch the unit onto the rack by pressing towards the wall.
INSTALLATION
This unit must be connected by a certifi ed electrician. Connect the bare wire (ground) to the green wire of the unit. Connect wires from
the electrical box to the unit’s supply leads.
N.B. This product must be connected by a qualifi ed electrician,
according to the electrical and building codes effective in your region.
ELECTRICAL CONNECTION
TEMPERATURE CONTROL AND DISPLAY
The thermostat has two modes: the DAY mode, identifi ed on the digital screen by a SUN icon and the NIGHT mode, identifi ed by a MOON icon. To switch from one mode to the other, simultaneously press down both buttons once.
N.B. When you select the NIGHT mode, the thermostat will respond accordingly for the duration of the time preprogrammed for this mode (see “Selection of the Duration of the NIGHT Mode”). W hen the preprogrammed time has passed, the thermostat will automatically return to the DAY mode.
THE NORMAL DISPLAY WILL CONTINUOUSLY INDICATE:
- the current mode icon ( or
);
- the ANTIFREEZE mode icon (
), (if applicable, see “Antifreeze Protection”);
- the LOCK icon (
), (if applicable, see “Lock option”);
- the automatic mode icon (
), (if applicable, see “Automatic Mode”);
- the ambient temperature of the room;
- the selected temperature scale (°C or °F).
BUTTON FUNCTIONS
WITH A BUILT-IN ELECTRONIC THERMOSTAT
OPERATION
BUTTONS IN DAY MODE IN NIGHT MODE
ONE (1) BUTTON
TO SET THE DESIRED TEMPERATURE
TO SET THE DESIRED TEMPERATURE
TWO (2) BUTTONS, SIMULTANEOUSLY
TO SWITCH TO NIGHT MODE FOR A PRE-DETERMINED TIME
TO SWITCH BACK TO DAY MODE
TWO (2) BUTTONS, SIMULTANEOUSLY FOR 3 SECONDS
TO ACTIVATE OR DEACTIVATE THE BACKLIGHT
TO SELECT THE DURATION OF THE NIGHT
MODE
TWO (2) BUTTONS, SIMULTANEOUSLY FOR 8 SECONDS
TO CHANGE THE TEMPERATURE SCALE (°C OR °F)
N/A
TWO (2) BUTTONS, SIMULTANEOUSLY FOR 13 SECONDS
TO ACTIVATE THE LOCK OPTION
N/A
Unit
Electric
box
Connector (marette)
L1 (black)
L2 (red)
Ground (green)
INSTALLATION, ELECTRICAL CONNECTION & OPERATION
N.B. Cut off power supply at circuit breaker/fuse before proceeding to the installation and wiring connections. This product must be con-
nected by a certifi ed electrician, according to the electrical and building codes effective in your region. Consult the wiring plan found on
the unit.
To reduce the risk of fi re, do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of the heater. Do not mount in
contact with combustible aterial. Do not mount in close proximity to another unit.
DANGER – High temperatures may be generated under certain abnormal conditions. Do not partially or fully cover or obstruct the front of this
heater.
Warning: the heater must be properly installed before it is used.
5
INSASIL0314
DAY MODE
HOW TO SET THE DAY TEMPERATURE
By pressing down the top or bottom button, you will enter the setting
mode indicated by the fl ashing SUN icon. This way, you can see the
DAY temperature setting.
You can change the temperature with these same buttons by increasing (top button) or decreasing (bottom button) the set point. The temperature set point will increase or decrease by increments
of 0.5 °C (or 1 °F) each time you press down a button. If you hold down the button, the temperature will quickly scroll through, allowing a faster and more effi cient setting.
Once the temperature is set, release the button; normal display will resume after three (3) seconds.
NIGHT LIGHT MODE
Normally, the backlight is activated when you press down the button,
and stays on for fi fteen (15) seconds afterwards. To keep the backlight
on, simultaneously press down both buttons for 3 seconds (until the backlight blinks), then release. Repeat this procedure to deactivate the night light mode.
SELECTION OF THE TEMPERATURE SCALE
To change the temperature scale (°C or °F), simultaneously press down both buttons for eight (8) seconds, the °C or °F symbol will blink.
Release the buttons to set the new scale (note that the backlight will blink after 3 seconds).
LOCK OPTION
It is possible to impose a maximum temperature set point by activating this mode. Then, it becomes impossible to exceed this set point,
regardless of the current mode (DAY/NIGHT). However, it is still
possible to lower the temperature at your discretion. All the other functions remain unchanged. For increased security, the power supply needs to be cut off in order to deactivate the lock.
LOCKING PROCEDURE
1. From the DAY mode, adjust the set point to the maximum desired value.
2. Simultaneously press down both buttons for more than 13 seconds,
until the LOCK icon is displayed (note that the backlight will blink after 3 seconds and the °C and °F symbols, after 8 seconds).
3. Release the buttons. The thermostat is now locked.
UNLOCKING PROCEDURE
1. Cut off the power supply of the thermostat at the electrical panel.
2. Wait about 1 minute.
3. Restore the power supply of the thermostat at the electrical panel.
4. The LOCK icon blinks on the thermostat display, meaning that it is
possible to unlock the thermostat.
5. While the LOCK icon is blinking, simultaneously press down both buttons for more than 10 seconds, until the LOCK icon disappears.
6. Release the arrows. The thermostat is now unlocked.
N.B. If the thermostat is not unlocked within 5 minutes after restoring the power supply, the LOCK icon will stop blinking and it will be impossible to unlock the thermostat without cutting off the power supply again.
NIGHT MODE
HOW TO SET THE NIGHT TEMPERATURE
By pressing down the top or bottom button, you will enter the setting
mode indicated by the fl ashing MOON icon. This way, you can see the NIGHT temperature setting.
You can change the temperature with these same buttons by
increasing (HIGH button) or decreasing (LOW button) the set point.
The temperature set point will increase or decrease by increments of
0.5 °C (or 1 °F) each time you press a button. If you hold down the button, the temperature will quickly scroll through, allowing a faster and more effi cient setting.
Once the temperature is set, release the button; normal display will resume after three (3) seconds.
SELECTION OF THE DURATION OF THE NIGHT MODE
By simultaneously pressing down both buttons for three (3) seconds,
you will be able to program the desired duration of the NIGHT mode.
You can decrease or increase the number of hours (1 to 999 hours). If
you hold down the button, the hours will quickly scroll through allowing
a faster setting. Normal display will resume three (3) seconds after releasing the button.
Therefore, you can regulate the unit according to your specifi c needs.
For example, to save energy and increase comfort at night, you can set the number of hours so that the unit automatically switches to DAY mode when you awake (see “Automatic Mode”). Furthermore, if you are going away for some time and wish to save energy during your absence without having to come back to an uncomfortable room, simply indicate the number of hours you will be absent (1 day = 24
hours, 1 week = 168 hours). By setting the NIGHT mode this way
before leaving, the temperature will automatically switch back to DAY mode upon your return, thus ensuring optimal comfort.
AUTOMATIC MODE
To activate or deactivate this mode, you must switch to the “Selection of the
Duration of the NIGHT Mode”. The number of programmed hours must be 23 or less to activate the AUTOMATIC mode. To activate it, simultaneously
press down both buttons for three (3) seconds. To deactivate this mode, simultaneously press down both buttons again for three (3) seconds. If the number of programmed hours is increased to more than 23, the
AUTOMATIC mode will immediately be deactivated (if it was activated). The AUTOMATIC mode icon lights on or off as applicable.
If you do not press down any button for fi ve (5) seconds, you exit the programming mode and return to the NIGHT mode, the programming of the NIGHT mode is re-initialized and the AUTOMATIC mode becomes
effective (if it was activated). After 24 hours, the thermostat returns to
the NIGHT mode automatically.
Then, the night programming is re-initialized and another 24 hours
cycle starts. Even if the thermostat is in AUTOMATIC mode, you can switch from DAY mode to NIGHT mode at your discretion, it will not impact the 24 hours cycle or the automatic return of the NIGHT mode.
N.B. Activation of the OFF mode deactivates the AUTOMATIC mode.
When power is restored (after a power failure for example), the
AUTOMATIC mode is deactivated. If it was activated before the power­down, the AUTOMATIC mode icon blinks. Then, the thermostat will be in
DAY mode. The blinking will cease as soon as you press down a button.
PRECISE ELECTRONIC CONTROL
A chrono-proportional electronic thermostat controls this unit with a high degree of accuracy in order to minimize temperature differences and increase your comfort level. It allows very stable temperature and ensures uniform comfort. It also keeps the casing at a low temperature, making it more secure.
The chrono-proportional electronic thermostat entirely regulates the unit by increasing or decreasing the heating cycle percentage according to the selected temperature. Please note that the unit becomes warmer if the heating demand is higher and that it remains mildly warm when the demand is lower.
N.B. If the unit is set on high or if it is not functioning at all, the temperature gage of the thermostat sensor cannot take a precise reading. However, the reading becomes extremely precise once the heating level has stabilized. Therefore, uniform convection increases the precision of the thermostat.
OPERATION
Loading...