现货库存、技术资料、百科信息、热点资讯,精彩尽在鼎好!
Timing from Microseconds to Hours
Direct Replacement for Signetics NE555 Timer
BEIJING ESTEK ELECTRONICS CO.,LTD
Description
These devices are monolithic timing circuits capable of producing accurate time delays or oscillation.
Inthe time delaymode of operation, the timed interval is controlled by a single external resistor and capacit
or network. In the astable mode of operation, the frequency and duty cycle may
controlled with twoexternal resistors and a si ngle external capacitor.
be independently
Features
•
•
Astable or Monostable Operation
•
Adjustable Duty Cycle
•
TTL - Compatible Output Can Sink or Source Up to 200 mA
•
Temperature Stability of 0.005% per
•
o
C
DIP-8
SOP-8
•
Precision timing
•
Pulse generation
•
Sequential timing
•
Time delay generation
•
Pulse width modulation
•
Pulse position modulation
•
Missing pulse detector
(TA=25°C, unless otherwise specified)
Input Voltage (control,reset, threshold and trigger)
Storage Temperature Range,
Electrical characteristics
BEIJING ESTEK ELECTRONICS CO.,LTD
CC
(TA=25°C, VCC=+5V to +15V, unless otherwise specified)
Operating Supply Voltage Range 4.5 16 V
Threshold Voltage Level VCC=15V 8.8 10 11.2 V
Threshold Current (Note 1) (see Note 1) 30 250 nA
Trigger Voltage Level VCC=15V 4.5 5 5.6 V
Trigger Current Trigger at 0V 0.5 2 µA
Reset Voltage Level 0.3 0.7 1 V
Reset Current Reset at V
Discharge Leakage Current 20 100 nA
Control Voltage Level VCC=15V 9 10 11 V
Low-level Output Voltage VCC=15V IOL=10mA 0.1 0.25
High-level Output Voltage VCC=15V IOL=-100mA 12.75 13.3
Supply Current Output Low, VCC=15V 10 15 mA
Parameter Test conditions
VCC=5V 2.4 3.3 4.2
VCC=5V 1.1 1.67 2.2
CC
Reset at 0V -0.4 -1.5
VCC=5V 2.6 3.3 4
VCC=5V IOL=5mA 0.25 0.35
VCC=5V IOL=-100mA 2.75 3.3
No Load VCC=5V 3 6
Output High, VCC=15V 9 13
No Load VCC=5V 2 5
(Note 2)
IOL=50mA 0.4 0.75
IOL=100mA 2 2.5
IOL=200mA 2.5
IOL=8mA 0.3 0.4
IOL=-200mA 12.5
Min Typ Max Units
0.1 0.4 mA
(Note4)
astable
of Timing Interval astable 150 500
Supply Voltage Sensitivity of monostable
Timing Interval astable 0.3 1
Output Pulse Rise Time
Output Pulse Fall Time 100 300
Note 1: This parameter influences the maximum value of the timing resistors RAand RBin the circuit on Fig 1. For example, when
VCC=5V, the maximum value is R=RA+RB=3.4 MΩ, and VCC=15V, the maximum value is 10 MΩ.
Note 2: For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
Note 3: Timing interval error is defined as the difference between the measured value and the average value of a random sample from
each process run.
Note 4: Values specified are for a device in a monostable circuit similar to Fig. 2, with component values as follow: RA=2KΩto 100 KΩ,
C=0.1µF.
Note 5: Values specified are for a device in an astable circuit similar to Fig. 1, with component values as follow: RA, RB=1KΩto 100 KΩ,
TA=25°C
CL=15pF, TA=25°C
0.1 0.5 %/V
100 300 ns