Steinel XLED PRO slave, XLED PRO Wide slave, XLED PRO Wide XL slave, XLED PRO Square slave, XLED PRO Square XL slave User Manual

DGBS
RUS CN BG LV LT EST HR SLO RO PL SK CZ H TR GR N FIN DK S P E I NL F GB D
STEINEL Vertrieb GmbH
D
Dieselstraße 80-84 33442 Herzebrock-Clarholz Tel: +49/5245/448-188 Fax: +49/5245/448-197 www.steinel.de
Steinel Austria GmbH
Hirschstettner Strasse 19/A/2/2 A-1220 Wien Tel.: +43/1/2023470 Fax: +43/1/2020189 info@steinel.at
PUAG AG
CH
Oberebenestrasse 51 CH-5620 Bremgarten Tel.: +41/56/6488888 Fax: +41/56/6488880 info@puag.ch
STEINEL U.K. LTD.
GB
25, Manasty Road · Axis Park Orton Southgate GB-Peterborough Cambs PE2 6UP Tel.: +44/1733/366-00 Fax: +44/1733/366-701 steinel@steinel.co.uk
Socket Tool Company Ltd
IRL
Unit 714 Northwest Business Park Kilshane Drive · Ballycoolin · Dublin 15 Tel.: 00353 1 8809120 Fax: 00353 1 8612061 info@sockettool.ie
STEINEL FRANCE SAS
F
ACTICENTRE - CRT 2 Rue des Famards - Bât. M - Lot 3 F-59818 Lesquin Cedex Tél.: +33/3/20 30 34 00 Fax: +33/3/20 30 34 20 info@steinelfrance.com
Van Spijk B.V.
NL
Postbus 2 5688 HP OIRSCHOT De Scheper 402 5688 HP OIRSCHOT Tel. +31 499 571810 Fax. +31 499 575795 info@vanspijk.nl www.vanspijk.nl
VSA Belgium
B
Hagelberg 29 B-2440 Geel Tel.: +32/14/256050 Fax: +32/14/256059 info@vsabelgium.be www.vsabelgium.be
Minusines S.A.
L
8, rue de Hogenberg L-1022 Luxembourg Tél. : (00 352) 49 58 58 1 Fax : (00 352) 49 58 66/67 www.minusines.lu
SAET-94 S.L.
E
C/ Trepadella, n° 10 Pol. Ind. Castellbisbal Sud E-08755 Castellbisbal (Barcelona) Tel.: +34/93/772 28 49 Fax: +34/93/772 01 80 saet94@saet94.com
STEINEL Italia S.r.l.
I
Largo Donegani 2 I-20121 Milano Tel.: +39/02/96457231 Fax: +39/02/96459295 info@steinel.it www.steinel.it
Pronodis -
P
Soluções Tecnológicas, Lda.
Zona Industrial Vila Verde Sul, Rua D, n.º 11 P-3770-305 Oliveira do Bairro Tel.: +351 234 484 031 Fax: +351 234 484 033 pronodis@pronodis.pt www.pronodis.pt
KARL H STRÖM AB
S
Verktygsvägen 4 S-55302 Jönköping Tel.: +46/36/31 42 40 Fax: +46/36/31 42 49 www.khs.se
Roliba A/S
DK
Hvidkærvej 52 DK-5250 Odense SV Tel.: +45 6593 0357 Fax: +45 6593 2757 www.roliba.dk
Oy Hedtec Ab
FI
Lauttasaarentie 50 FI-00200 Helsinki Tel.: +358/207 638 000 Fax: +358/9/673 813 lighting@hedtec.fi www.hedtec.fi/valaistus
Vilan AS
N
Olaf Helsetsvei 8 N-0694 Oslo Tel.: +47/22725000 post@vilan.no www.vilan.no
PANOS Lingonis + Sons O. E.
GR
Aristofanous 8 Str. GR-10554 Athens Tel.: +30/210/3212021 Fax: +30/210/3218630 lygonis@otenet.gr
SAOS Teknoloji Elektrik Sanayi ve
TR
Ticaret Limited Şirketi
Halil Rıfat Paşa mahallesi Yüzerhavuz Sokak PERPA Ticaret Merkezi A Blok Kat 5 No.313 Şişli / İSTANBUL Tel.: +90 212 220 09 20 Fax: +90 212 220 09 21 iletisim@saosteknoloji.com.tr www.saosteknoloji.com.tr
ELNAS s.r.o.
CZ
Oblekovice 394 CZ-67181 Znojmo Tel.: +420/515/220126 Fax: +420/515/244347 info@elnas.cz · www.elnas.cz
„LŁ“ Spółka z ograniczoną
PL
odpowiedzialnością sp.k.
Byków, ul. Wrocławska 43 PL-55-095 Mirków Tel.: +48 71 3980818 Fax: +48 71 3980819 elektro@langelukaszuk.pl
DINOCOOP Kft
H
Radvány u. 24 H-1118 Budapest Tel.: +36/1/3193064 Fax: +36/1/3193066 dinocoop@dinocoop.hu
KVARCAS
LT
Neries krantine 32 LT-48463, Kaunas Tel.: +370/37/408030 Fax: +370/37/408031 info@kvarcas.lt
Fortronic AS
EST
Tööstuse tee 10, EST-61715, Tõrvandi, Ülenurme vald, Tartumaa Tel.: +372/7/475208 Fax: +372/7/367229 info@fortronic.ee www.fortronic.ee
ELEKTRO – PROJEKT PLUS D.O.O.
SLO
Suha pri Predosljah 12 SLO-4000 Kranj PE GRENC 2 4220 Škofja Loka Tel.: 00386-4-2521645 GSM: 00386-40-856555 info@elektroprojektplus.si www.priporocam.si
NECO SK, A.S.
SK
Ružová ul. 111 SK-01901 Ilava Tel.: +421/42/4 45 67 10 Fax: +421/42/4 45 67 11 neco@neco.sk www.neco.sk
Steinel Distribution SRL
RO
Parc Industrial Metrom RO-500269 Brasov Str. Carpatilor nr. 60 Tel.: +40(0)268 53 00 00 Fax: +40(0)268 53 11 11 www.steinel.ro
Daljinsko upravljanje d.o.o.
HR
Bedricha Smetane 10 HR-10000 Zagreb t/ 00385 1 388 66 77 f/ 00385 1 388 02 47 daljinsko-upravljanje@inet.hr www.daljinsko-upravljanje.hr
AMBERGS SIA
LV
Brivibas gatve 195-16 LV-1039 Riga Tel.: 00371 67550740 Fax: 00371 67552850 www.ambergs.lv
ТАШЕВ-ГАЛВИНГ ООД
BG
Бул. Климент Охридски № 68 1756 София, България Тел.: +359 2 700 45 45 4 Факс: +359 2 439 21 12 info@tashev-galving.com www.tashev-galving.com
Best - Snab
RUS
ул.1812 года, дом 12 121127 Москва · Россия Tel: +7 (495) 280-35-53 info@steinel.su www.steinel.su
STEINEL China
CN
Representative Office Shanghai Rm. 25 A, Huadu Mansion No. 838 Zhangyang Road Shanghai 200122 Tel: +86 21 5820 4486 Fax: +86 21 5820 4212 james.chai@steinel.cn info@steinel.cn www.steinel.cn
XLED PRO Wide slave XLED PRO Wide XL slave
XLED PRO Square slave XLED PRO Square XL slave
110047651 06/2016_J Technische Änderungen vorbehalten. / Subject to technical modification without notice.
XLED PRO slave
Information
3
XLED PRO
Square Slave
XLED PRO
Wide Slave
XLED PRO
Wide Slave
4.2
4.3
4.4
4.5
4.6
4.1
...
D � � � � � � � � � � � 6 GB � � � � � � � � � � 9 S � � � � � � � � � � 12
Textteil beachten! Follow written instructions! Följ den skriftliga
montageinstruktionen�
– 2 –
– 3 –
5.1
5.2
5.3
5.4
5.5
5.6
4.3
4.4
4.5
4.6
5.1
5.2
4.7
4.9
4.10
5.3
5.4
4.8
– 4 –
– 5 –
!
!
9. Technische Daten
Sensor-LED-Strahler XLEDPROSquareXL Slave und XLEDPROSquare Slave
Netzanschluss 220-240 V / 50/60 Hz Leistung XLEDPROSquare XL Slave / Wide XL Slave 48 W
Lichtfarbe 4000 K (neutralweiß) SDCM 3 Farbwiedergabeindex Ra > 80 Lichtstrom XLEDPROSquareXL Slave / Wide XL Slave 4400lm, 91,7lm/W
Grundlicht 10min, 30min (über RC9), ganze Nacht Lebensdauer LED 50.000 h (L70B10 nach LM80) Schwenkbereich LED-Panel 0-90° vertikal
Projizierte Fläche XLEDPROSquare Slave 362 cm
Schutzart IP 54 Schutzklasse I / IK03 Temperaturbereich - 20 °C bis + 40 °C
XLEDPROWideXL Slave und XLEDPROWide Slave
XLEDPROSquare Slave / Wide Slave 24,8 W
XLEDPROSquare Slave / Wide Slave 2400lm, 96,8lm/W
360° horizontal
2
XLEDPROWide Slave 403 cm
2
10. Betriebsstörungen
Störung Ursache Abhilfe
LED-Strahler ohne Spannung
LED-Strahler schaltet nicht ein
n Sicherung defekt, nicht einge-
schaltet, Leitung unterbrochen
n Kurzschluss n bei Tagesbetrieb, Dämme-
rungseinstellung steht auf Nachtbetrieb
n Netzschalter AUS n Sicherung defekt
n Erfassungsbereich nicht
gezielt eingestellt
n neue Sicherung, Netzschalter
einschalten; Leitung mit Span­nungsprüfer überprüfen
n Anschlüsse überprüfen n neu einstellen
n Einschalten n neue Sicherung, evtl. Anschluss
überprüfen
n neu justieren
GB
1� About this document
Please read carefully and keep in a safe place�
– Under copyright. Reproduction either in whole or
in part only with our consent.
– Subject to change in the interest of technical
progress.
Symbols
Hazard warning!
Reference to other information in the
...
document�
2� General safety precautions
Disconnect the power supply before attempting any work on the unit�
• Installing these units involves work on the mains supply voltage; installation must therefore be car­ried out professionally in accordance with the ap­plicable national wiring regulations and electrical operating conditions (D-VDE 0100, a -ÖVE/ ÖNORM E 8001-1, h-SEV 1000)
• The floodlight enclosure heats up when the light is on. Only adjust the angle of the LED head once it has cooled down.
• The light must be positioned so that it is not expected that anybody can stare into the light for any prolonged period from a distance of less than 0.3 m.
3� XLEDPROSquare / Wide Slave
Proper use
– Sensor-switched floodlight with LEDs as light
source.
– Suitable for wall mounting outdoors. – Data line (D-line, optional) for synchronous
switching.
Basic light level function
As an option, main and basic light can be switched ON and OFF in synchrony by means of an ad­ditional data line (D-line) between the XLED PRO sensor-switched LED floodlight and XLED PRO slave LED floodlight (master-slave).
Basic brightness by means of basic light LEDs provides a low level of illumination. The main light is only switched on for the time selected when movement occurs in the detection zone (master). The floodlight then switches to the level of basic brightness selected at the master.
Models
– XLED PRO Square XL Slave – XLED PRO Square Slave – XLED PRO Wide XL Slave – XLED PRO Wide Slave
Package contents
XLEDPROSquare Slave (Fig� 3�1) XLEDPROWide Slave (Fig� 3�3)
Product dimensions
XLEDPROSquare Slave (Fig� 3�2) XLEDPROWide Slave (Fig� 3�4)
Unit components (Fig� 3�5) A Floodlight head B Basic light level LED C Enclosure D Wall mount E Plug connection
4� Electrical installation
Connect the mains power supply lead (Fig� 4�7)
The mains power supply lead is a 3-core cable: L = phase conductor (usually black,
brown or grey)
N = neutral conductor (usually blue) PE = protective-earth conductor (green/yellow) D = D-line (data line) optional
If you are in any doubt, identify the conductors using a voltage tester; then disconnect from the power supply again. Connect phase (L) and neutral conductor (N) to the terminal block.
Wiring diagram (Fig� 4�8)
Note:
A power switch for switching the light ON and OFF can be installed in the mains supply lead. This is a prerequisite for the manual override function.
Important:
Incorrectly wired connections will produce a short circuit later on in the product or your fuse box. In this case, you must identify the individual conduc­tors once again and reconnect them.
GB
– 8 –
– 9 –
The light source of this luminaire cannot be replaced. If the light source needs to be replaced (e.g. at the end of its service life), the complete luminaire must be replaced.
5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Positioning the wall mount (Fig� 4�1)
Mounting procedure
• Switch OFF power supply (Fig� 4�2)
• Undo retaining screws (Fig� 4�3)
• Detach enclosure from wall mount (Fig� 4�3)
• Mark drill holes (Fig� 4�4)
• Drill holes and fit wall plugs – Concealed installation (Abb� 4�5) – Surface-mounted installation (Fig� 4�6)
• Connect conductors (Fig� 4�7)
• Fit enclosure (C) onto wall mount (D). Ensure
correct plug connection (E) (Fig� 4�9)
• Screw in retaining screws (Fig� 4�9)
• Switch ON power supply (Fig� 4�10)
6� Information
– Floodlight head adjustment range (5�1 / 5�2) – Reference to light-distribution curves
(Fig� 5�3 - 5�6)
7� EC Declaration of Conformity
This product complies with the requirements defined in the following standards, legislation and directives:
– Low Voltage Directive 2014/35/EU – EMC Directive 2014/30/EU – RoHS Directive 2011/65/EU – WEEE 2012/19/EU
8� Warranty
All rights are based on our warranty period. We guarantee that your STEINEL Professional sensor product will remain in perfect condition and proper working order for a period of 5 years. We guaran­tee that this product is free from material, manufac­turing and design flaws. In addition, we guarantee that all electronic components and cables function in the proper manner and that all materials used and their surfaces are without defects.
Making Claims
If you wish to make a claim, please send your product complete and carriage paid with the origi­nal receipt of purchase, which must show the date of purchase and product designation, either to your retailer or contact us at STEINEL (UK) Limited,
25 Manasty Road, Axis Park, Orton Southgate, Peterborough, PE2 6UP, for a returns number.
For this reason, we recommend that you keep your receipt of purchase in a safe place until the warranty period expires. STEINEL shall assume no liability for the costs or risks involved in returning a product.
For information on making claims under the terms of the warranty, please go to
www�steinel-professional�de/garantie
9. Technical specifications
Sensor-switched LED floodlights XLEDPROSquareXL Slave and XLEDPROSquare Slave
Mains power supply 220-240 V / 50/60 Hz Output XLEDPROSquare XL Slave / Wide XL Slave 48 W
Colour temperature 4000 K (neutral white) SDCM 3 Colour rendering index Ra > 80 Luminous flux XLEDPROSquareXL Slave / Wide XL Slave 4400lm, 91.7lm/W
Basic light 10min, 30min (via RC9), all night LED life expectancy 50,000 h (L70B10 to LM80) LED panel adjustment range 0-90° tilting
Area illuminated XLEDPROSquare Slave 362 cm
IP rating IP 54 Protection class I / IK03 Temperature range -20°C to +40°C
XLEDPROWideXL Slave and XLEDPROWide Slave
XLEDPROSquare Slave / Wide Slave 24.8 W
XLEDPROSquare Slave / Wide Slave 2400lm, 96.8lm/W
360° swivelling
2
XLEDPROWide Slave 403 cm
2
10. Troubleshooting
Malfunction Cause Remedy
Sensor-switched LED floodlight without power
Sensor-switched LED floodlight will not switch ON
n Fuse faulty, not switched ON,
break in wiring
n Short circuit n Twilight setting in night mode
during daytime operation
n Mains power switch OFF n Fuse faulty
n Detection zone not properly
targeted
n Replace fuse, turn ON mains
switch, check lead with volt­age tester
n Check connections n Adjust setting
n Switch ON n Fit new fuse, check connection
if necessary
n Readjust
GB
– 10 –
– 11 –
Loading...