Service
D
STEINEL-Schnell-Service Dieselstraße 80–84 33442 Herzebrock-Clarholz Tel.: +49/52 45/4 48-1 88 www.steinel.de e-mail: info@steinel.de
A
I. MÜLLER Peter-Paul-Str. 15 A-2201 Gerasdorf bei Wien Tel.: +43/22 46/21 46 Fax: +43/22 46/2 54 66 e-mail: info@imueller.at
PUAG AG Oberebenestrasse 51 CH-5620 Bremgarten Tel.: +41/56/6 48 88 88 Fax: +41/56/6 48 88 50 e-mail: info@puag.ch
STEINEL U.K. LTD. 37, Manasty Road Orton Southgate GB-Peterborough PE2 6UP Tel.: +44/17 33/2 38-2 65 Fax: +44/17 33/2 38-2 70 e-mail: steinel@steineluk.com
SOCKET TOOL COMPANY 8, Queen Street IRL-Dublin 7 Tel: +3 53/1/8 72 54 33 Fax: +3 53/1/8 72 51 95 e-mail: sockettool@eircom.net
F
DUVAUCHEL S. A. 86/108 Avenue Louis Roche F-92230 Gennevilliers Cedex Tel.: +33/1 41 47 20 40 Fax: +33/1 47 99 44 09
HEGEMA PRESENT B.V. Christiaan Huygensstraat 4 NL-3291 CN Strijen Tel.: +31/78/6 74 44 44 Fax: +31/78/6 74 31 13 e-mail: info@hegema-present.nl
B
PRESENT Handel s.p.r.l. Toekomstlaan 6 Industriezone Wolfstee B-2200 Herentals Tel.: +32/14/25 74 74 Fax: +32/14/25 74 75 e-mail: info@present.be
L
A. R. Tech. 70, Millewee Boite Postale 1044 L-1010 Luxembourg Tel.: +3 52/49/33 33 Fax: +3 52/40/26 34 e-mail: com@artech.lu
I
THOELKE DISTRIBUZIONE S.N.C. Via Adamello 2/4 I-22070 Locate Varesino (Como) Tel.: +39/3 31/83 69 11 Fax: +39/3 31/83 69 13 thoelke.distribuzione@thoelke.it
E
SAET-94 S.L. Polig. Industrial Cova Solera C/Atenas, 5 E-08191 Rubi (Barcelona) Tel.: +34/93/5 88-67 25 Fax: +34/93/5 88-68 46 e-mail: saet94@retemail.es
P
F. Fonseca, S.A. Estrada de Taboeira, 87/89-Esgueira, Apartado 3003 3801-997 AVEIRO Tel.: +3 51/2 34/30 39 00 Fax: +3 51/2 34/30 39 10 e-mail: ffonseca@ffonseca.com
S
KARL H STRÖM AB Verktygsvägen 4 S-553 02 JÖNKÖPING Tel.: +46/36/31 42 40 Fax: +46/36/31 42 49 www.khs.se e-mail: kontakt@karlhstrom.se
BROMMANN Ellegaardvej 18 DK-6400 Sønderborg Tel.: +45/74 42 88 62 Fax: +45/74 42 88 62 e-mail: brommann@brommann.dk
Hedengren Yhtiöt Oy Hedtec Ab, Mänkimiehentie 4 FIN-02780 Espoo Tel.: +3 58/9/68 28 81 Fax: +3 58/9/67 49 18 www.hedtec.fi e-mail: hedtec@hedtec.fi
N
STAUBO ELEKTRO­MASKIN A.S. Bjørnerudveien 12c 1266 Oslo Tel.: +47/23 75 35 00 Fax: +47/22 75 35 01 e-mail: post@staubo.no
ELNAS s.r.o. Oblekovice 394 CZ-67181 Znojmo Tel.: +4 20/5 15/22 01 26 Fax: +4 20/5 15/26 15 25 e-mail: info@elnas.cz www.elnas.cz
LANGE ¤UKASZUK Sp.j. Byków 25a PL-55-095 Mirków Tel.: +48/71/3 98 08 00 Fax: +48/71/3 98 08 02 e-mail: info@langelukaszuk.pl
KVARCAS 17-4 A. Mickeviciaus LT-3000 Kaunas Tel.: +3 70/37/32 88 23 Fax: +3 70/37/32 88 22 e-mail: kvarcas@kaunas.omnitel.net
FORTRONIC Plc. Tähe str. 108 EST-50113 Tartu Tel.: +3 72/7/47 52 08 Fax: +3 72/7/36 72 29 e-mail: fortron@online.ee
LOG Zabnica D.O.O. Podjetje Za Trgovino SLO-4209 Zabnica Tel.: +3 86/42/31 20 00 Fax: +3 86/42/31 23 31 e-mail: info@log.si
PANOS Lingonis + Sons O. E. 8, Aristofanous GR-10554 Athens Tel.: +30/2 10/3 21 20 21 Fax: +30/2 10/3 21 86 30 e-mail: lygonis@otenet.gr
EGE SENSÖRLÜ
$<',1/$70$I7+I+5 7I&9(3$=/WG67I *HUVDQ6DQD\L6LWHVL 6RNDN1R 75%DWL6LWHVL$QNDUD 7HO  )D[  HJHD\GLQODWPD#VXSHURQOLQHFRP
7863000 Technische Änderungen vorbehalten.
Page 2
1110
y Before undertaking any
work on the unit discon­nect the mains supply!
y The supply lead to be
connected must not be live during assembly. Therefore, first switch off the power and check that the circuit is dead by using a voltage tester.
y The installation of these
units involves connecting them to the mains supply. The work must therefore be carried out in a profes­sional manner in accor­dance with the regulations involving installation and connection of electrical appliances specific to each country (IEE Wiring Regulations). If in doubt contact a qualified electri­cian.
y
Do not mount the unit on surfaces that are normally easily inflammable.
y The halogen fixture must
not be aligned to face the wall on which it is moun­ted.
y The halogen fixture must
be in a horizontal position (± 15°).
y
The spotlights must be mounted in such a way that in all possible setting angles they are at least 1 metre from the surface at which they are directed.
y The halogen spotlights are
only intended for wall mounting and not for cei­ling mounting. They must not be installed less than 1 m from the ceiling.
y
In the event that the pro­tective glass is broken, it is imperative that a new protective glass is instal­led before the light is ope­rated again.
y To avoid inflammation of
the skin and eyes do not expose yourself for any length of time to a HalogenSensorFixture being operated at 10% over the nominal voltage.
y The floodlight housing
becomes very hot during operation. Only align the floodlight when the hou­sing has cooled down.
Safety Notifications
GB
Installation Instructions
The Principle
Any movement will activate the light, the alarm and much more, all for your con­venience and security. These HalogenSensor
Fixtures can be mounted quickly anywhere and are immediately ready for opera­tion, whether they are to be used for private purposes to
illuminate your property and home or for commercial pur­poses to illuminate business premises.
The HS 150, HS 300 and the microprocessor controlled HS 500 halogen fixtures are equipped with two 120° pyro sensors that detect the invi­sible heat radiation emitted by moving bodies (such as people or animals etc.). The
thermal radiation detected in this way is converted elec­tronically and activates the fixture. No thermal radiation is detected through barriers such as walls or panes of glass and therefore no swit­ching operation is triggered.
With the aid of the two pyro sensors an angle of covera­ge of 240° with an angle opening of 180° is achieved.
Detection zone HS 150 = approx. 300 m
2
HS 300 = approx. 300 m
2
HS 500 = approx. 800 m
2
N.B: The most reliable mo­tion detection is achieved by mounting or aligning the unit laterally to the direction of movement and ensuring that no obstacles (such as trees, walls etc.) obstruct the line of sight.
approx. 5 m approx. 12 m
GB
Reach: HS 150 = max. 12 m
HS 300 = max. 12 m HS 500 = max. 20 m
Halogen_Duo_10spr 16.02.2004 12:12 Uhr Seite 12
Page 3
1312
Installation
Mount the unit on a firm sur­face to avoid any switching errors.
Connection of supply lead
L = phase conductor (usually black or brown) N = neutral conductor (usual­ly blue) PE = if applicable, protective­earth conductor (green/ yellow)
N.B: If the connections are reversed, this will lead to a subsequent short-circuit eit­her in the unit or in your fuse box, in which case the indivi­dual wires must be identified and reconnected correctly. A mains power switch can also be installed, of course, in the supply lead to switch the power ON and OFF.
Exposed wiring
For exposed wiring, two lugs are provided at the bottom of the mounting plate
2
. Snap off one of the two lugs. Close off the mounting plate cable entry with the sealing plug. Pierce the sealing plug and push the cable through. Once the cable has been pushed through, you can screw the mounting plate into position and complete the connection.
230 VOLT
1
Zugang für Aufputzmontage
2
6 mm
3 6
N
L
PE
N
L
4
5
lugs for exposed wiring
7
Functions
Reach setting / Calibration
Time setting (period of illu-
mination for the Halogen SensorFixture 10 secs. - 15 mins.).
Adjustment control set to number 1 = shortest time (approx. 10 secs.)
Adjustment control set to number 6 = longest time (approx. 15 mins.).
With every movement that takes place within the detec­tion zone the set time is reactivated.
Twilight setting (Sensor response threshold 2 - 2000 lux)
Adjustment control set to number 1 = daytime ope­ration (approx. 2000 lux)
Adjustment control set to number 6 = night time ope­ration (approx. 2 lux).
Twilight setting / HS 500 DUO
Important: Due to the extensive sensor reach, undesired switching of the fixture can take place because of objects (i. e. cars) heated by sun light.
We therefore recommend setting at dusk.
Remove attachment ring
80°
80°
approx. 10 sec.–max. 15 min.
Halogen_Duo_10spr 16.02.2004 12:12 Uhr Seite 14
Page 4
1514
Reach setting / Examples
12 m
12 m
6 m
6 m
6 m
12 m*
12 m*
*HS150 -12m / HS300 -12m / HS500 -20 m
Technical Specifications
Maintenance
HalogenSensorFixtures HS 150 HS 300 HS 500
Output: max. 150 Watt max. 300 Watt max. 500 Watt
Assembly: 230–240 V 230–240 V 230–240 V
Detection angle: 240° with 180° 240° with 180° 240° with 180°
angle of aperture angle of aperture angle of aperture
Swivelling range of sensor unit: ± 80° ± 80° ± 80°
Swivelling range of Halogen Sensor Fixture: horizontal ± 40° horizontal ± 40° horizontal ± 40°
vertical + 110 vertical + 110 vertical + 110 to – 40° to – 40° to – 40°
Time setting: 10 secs. – 15 mins. 10 secs. –15 mins. 10 secs. –15 mins.
Twilight setting: 2–2000 lux 2–2000 lux 2–2000 lux
Reach: max. 12 m max. 12 m max. 20 m
Type of enclosure: I P 44 IP 44 IP 44
HalogenSensorFixtures are suitable for activating lights and alarms. The unit is not suitable for burglar alarm systems. Weather conditions may influence the function of the HalogenSensorFixtu­re. Strong gusts of wind,
snow, rain and hail can lead to switching errors as the unit cannot distinguish between sudden changes in temperature and heat sources. If the detector lens becomes dirty, it can be wiped with a damp cloth
(without using any cleaning agents).
Halogen_Duo_10spr 16.02.2004 12:12 Uhr Seite 16
Page 5
1716
Troubleshooting
Malfunction Cause Remedy
HalogenSensorFixture without power
y Defective fuse, not swit-
ched on, break in wiring
y Short-circuit
y Replace fuse, switch on
power switch, check wiring with voltage tester
y Check connections
HalogenSensorFixture will not switch on
y Light threshold set to
night-time operation during daytime operation
y Defective bulb y Power switch OFF y Defective fuse
y Detection zone not pro-
perly targeted
y Change setting
y Replace bulb y Switch on y Replace fuse, check
connection, if necessary
y Recalibrate
HalogenSensorFixture will not switch off
y Continual movement in
detection zone
y Check detection zone and
recalibrate or shroud if necessary
HalogenSensorFixture keeps switching ON and OFF
y Animals moving in detec-
tion zone
y Cover up sensor, change
detection zone, or shroud
HalogenSensorFixture comes on when it should not
y Wind is moving trees and
shrubs in detection zone
y Cars in the street are
being detected
y Sudden temperature
change due to weather (wind, rain, snow) or air discharged from extractor fans or open windows
y HalogenSensorFixture is
moving (swaying) due to gusts of wind or heavy precipitation
y Change detection zone or
shroud
y Alter zone, install at diffe-
rent location
y Mount the HalogenSensor
Fixture on a firm surface
Functional Warranty
This STEINEL product has been manufactured with great care, and its operation and safety have been tested in conformity with the cur­rent regulations. Production is also submitted to final random-sample testing.
The warranty period is 36 months, starting on the date of sale to the user. We undertake to remedy faults caused by material or manufacturing defects. This warranty undertaking shall be performed by the repair or replacement of the defec­tive parts, at to our own cho­ice.
This warranty does not cover damage to wear parts or damage and faults cau­sed by incorrect operation and maintenance. Breakage due to a fall is also not covered. Further conse­quential damage to external items is excluded.
Claims under warranty shall only be accepted if the pro­duct, not disassembled, well packed and complete with sales slip or invoice (date of purchase and dealer's stamp) is sent to the appro­priate Service Centre or handed in to the dealer wit­hin the first six months.
Repair Service: Our customer service department will repair faults not covered by warranty or after the warranty period. Please send the product well packed to your nearest Service Centre.
C
Declaration of Conformity
This product conforms to low voltage directive
73/23/EEC and EMC direc­tive 89/336/EEC.