Filter fans are used to provide "cooling" by forced air-circulation in enclosures and cabinets containing eletrical/ electronic and other components. The interior temperature of an enclosure can be reduced by channelling cooler, filtered outside air into the enclosure, thus expelling hot inside air. The resulting airflow prevents formation of localized hot pockets and protects electronic components from overheating.
The Filter Fan Plus series encompasses a new air-flap technology on the air outlet side, thereby reaching an unparalleled high degree of airflow. A unique ratchet mechanism is used for easy installation. It provides safe and secure mounting while guaranteeing a tight seal. Depending on the requirements, there are two optional systems available – the FPI or the FPO system (FPI = "in", FPO = "out"). The FPI system is the more commonly known installation system, where a filter fan located in the lower part of the enclosure draws cleaner, cooler air into the enclosure (airflow direction "In"). This system consists of a filter fan and exhaust filter. On opposite, with the newer FPO system, the filter fan will be located in the upper area of the enclosure to draw warmer air out of the enclosure (airflow direction "Out"). The FPO system consists of an intake filter and exhaust filter fan. The Filter Fan Plus series may also be used outdoors with appropriate protective measures or when equipped with weather proof accessories, e.g. Hose-proof Hood FFH 086.
> Two optional systems for optimal
airflow (FPI/FPO)
> Industry-common enclosure cut-out
sizes (5 sizes)
> Single filter mat system design
TECHNICAL DATA
SYSTEM FPI
warmcold
Air-flaps
Filter mat
Exhaust Filter FPI 118
Filter Fan FPI 018
Connection 2 stranded wires, 11.8" (300 mm) long
Housing, hood, flaps plastic UL 94V-0, light grey;
Enclosure cut-out 3.6 x 3.6
Mounting frame 4 built-in ratchet push levers for mounting (6 ratchet stops to
Filter mat ISO coarse 55% acc. to ISO 16890 (G3), init. grav. arrestance 57%
Filter material synthetic mesh with progressive construction,
Operating/Storage temperature -40 to +158 °F (-40 to +70 °C)
Operating/Storage humidity max. 90 % RH (non-condensing)
Protection type/Protection class IP54 / I (grounded)
Environmental rating UL/NEMA UL TYPE 12 / NEMA 12
Approvals UL File No. E234324, VDE, EAC
Note other voltages on request
1
Drilling hole markings for screw mounting are indicated on mounting frame.
fan body aluminum, metal impeller
UV light resistant according to UL 746C (f1)
+0.04
inches (92 x 92+1 mm)
accommodate for wall thicknesses Gauge 9 to 19 or 1-4 mm). Additional screw mounting possible if needed
temperature resistant to +212 °F (+100 °C), self-extinguishing class F1, moisture resistant to 100 % RH, reusable
1
.
AIRFLOW DIRECTION "IN": FILTER FAN FPI 018
Part No. Operating voltage Air volume,
free blowing
01870.0-30 AC 230 V, 50/60 Hz 11.2 cfm (19 m³/h) 7.7 cfm (13 m³/h) 70 mA 12 W 39 dB (A) 2.6" (66 mm) 1.3 lbs. (0.6 kg) G3
01870.9-30 AC 115 V, 50/60 Hz 13.5 cfm (23 m³/h) 9.4 cfm (16 m³/h) 115 mA 11 W 43 dB (A) 2.6" (66 mm) 1.3 lbs. (0.6 kg) G3
Air volume
with exhaust filter
Current consumption
(50/60 Hz)
Power
consumption
Average noise level
(DIN EN ISO 4871)
Mounting depth Weight
(approx.)
Filter mat
AIRFLOW DIRECTION "IN": EXHAUST FILTER FPI 118
Part No. Mounting depth Weight (approx.) Air outlet
11870.0-00 1.1" (29 mm) 0.4 lbs. (0.2 kg) air-flap outlet technology
4.72" (120mm)
0.87"
1.14"
0.87"
4.72" (120mm)
3.62" (92mm)
2.6"
(66mm)
0.87"
(22mm)
3.62" (92mm)
1.14"
(29mm)
0.87"
(22mm)
4.72" (120mm)
3.62" (92mm)
2.84"
(72mm)
0.87"
(22mm)
0.87"
(22mm)
0.87"
(22mm)
3.62" (92mm)
4.72" (120mm)
2.84"
0.87"
0.87"
0.87"
3.62" (92mm)
COOLING
28.07.2020 | Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.
SYSTEM FPO
Filter Fan FPO 018
warmcold
AIRFLOW DIRECTION "OUT": FILTER FAN FPO 018
Part No.
01880.0-00 AC 230 V, 50/60 Hz 14.1 cfm (24 m³/h) 8.8 cfm (15 m³/h) 70 mA 12 W 38 dB (A) 2.8" (72 mm) 1.3 lbs. (0.6 kg) air-flaps
01880.9-00 AC 115 V, 50/60 Hz 18.8 cfm (32 m³/h) 11.2 cfm (19 m³/h) 115 mA 12 W 41 dB (A) 2.8" (72 mm) 1.3 lbs. (0.6 kg) air-flaps
Air-flaps
Intake Filter FPO 118
Filter mat
Operating voltage Air volume, free
blowing
Air volume
with intake filter
Current consumption
(50/60 Hz)
Power
consumption
Average noise level
(DIN EN ISO 4871)
Mounting depth Weight
(approx.)
Air outlet
47
47
AIRFLOW DIRECTION "OUT": INTAKE FILTER FPO 118
Part No. Mounting depth Weight (approx.) Filter mat
11880.0-30 0.9" (22 mm) 0.4 lbs. (0.2 kg) ISO coarse 55 % acc. to ISO 16890 (G3), initial gravimetric arrestance 57 %
FILTER MAT FM 086
Filter class 3.31 x 3.31" (84 x 84 mm) Initial gravimetric arrestance 1 packing unit
ISO coarse 55% acc. to ISO 16890 (G3) Part No. 08633.0-00 57 % 5 pieces
DIMENSIONED DRAWINGS
2.6"
3.62" (92mm)
(66mm)
(22mm)
(29mm)
3.62" (92mm)
(22mm)
(72mm)
3.62" (92mm)
(22mm)
(22mm)
(22mm)
FPI 118FPI 018 FPO 118FPO 018
3.6" (92 mm)
3.6" (92 mm)
ENCLOSURE CUT-OUT ENCLOSURE CUT-OUT
FILTER FAN PLUS
28.07.2020 | Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.
PRODUCT CATALOG - STEGO, Inc.
FPI/FPO 018 |
up to 68.9 cfm (4.9 x 4.9")
> New air-flap outlet technology for
high airflow > Easy mounting > Protection type/Environmental
ratings by independent testing
agencies (VDE & UL)
Filter fans are used to provide "cooling" by forced air-circulation in enclosures and cabinets containing eletrical/ electronic and other components. The interior temperature of an enclosure can be reduced by channelling cooler, filtered outside air into the enclosure, thus expelling hot inside air. The resulting airflow prevents formation of localized hot pockets and protects electronic components from overheating. The Filter Fan Plus series encompasses a new air-flap technology on the air outlet side, thereby reaching an unparalleled high degree of airflow. A unique ratchet mechanism is used for easy installation. It provides safe and secure mounting while guaranteeing a tight seal. Depending on the requirements, there are two optional systems available – the FPI or the FPO system (FPI = "in", FPO = "out"). The FPI system is the more commonly known installation system, where a filter fan located in the lower part of the enclosure draws cleaner, cooler air into the enclosure (airflow direction "In"). This system consists of a filter fan and exhaust filter. On opposite, with the newer FPO system, the filter fan will be located in the upper area of the enclosure to draw warmer air out of the enclosure (airflow direction "Out"). The FPO system consists of an intake filter and exhaust filter fan. The Filter Fan Plus series may also be used outdoors with appropriate protective measures or when equipped with weather proof accessories, e.g. Hose-proof Hood FFH 086.
> Two optional systems for optimal
airflow (FPI/FPO)
> Industry-common enclosure cut-out
sizes (5 sizes)
> Single filter mat system design
TECHNICAL DATA
SYSTEM FPI
warmcold
Air-flaps
Filter mat
Exhaust Filter FPI 118
Filter Fan FPI 018
Axial fan, ball bearing service life L10 at +104 °F (+40 °C): min. 37,000 h
Connection 2 stranded wires, 11.8" (300 mm) long
Housing, hood, flaps plastic UL 94V-0, light grey;
Enclosure cut-out 4.9 x 4.9
Mounting frame 4 built-in ratchet push levers for mounting (6 ratchet stops to
Filter mat ISO coarse 55% acc. to ISO 16890 (G3), init. grav. arrestance 57%
Filter material synthetic mesh with progressive construction,
Operating/Storage temperature -40 to +158 °F (-40 to +70 °C)
Operating/Storage humidity max. 90 % RH (non-condensing)
Protection type/Protection class IP54 / I (grounded)
Environmental rating UL/NEMA UL TYPE 12 / NEMA 12
Approvals UL File No. E234324, VDE, EAC
Note other voltages on request
1
Drilling hole markings for screw mounting are indicated on mounting frame.
fan body aluminum, metal impeller
UV light resistant according to UL 746C (f1)
+0.04
inches (124 x 124+1 mm)
accommodate for wall thicknesses Gauge 9 to 19 or 1-4 mm). Additional screw mounting possible if needed
temperature resistant to +212 °F (+100 °C), self-extinguishing class F1, moisture resistant to 100 % RH, reusable
1
.
AIRFLOW DIRECTION "IN": FILTER FAN FPI 018
Part No. Operating voltage Air volume,
free blowing
01871.0-30 AC 230 V, 50/60 Hz 30.6 cfm (52 m³/h) 24.7 cfm (42 m³/h) 120 mA 19 W 49 dB (A) 2.6" (66 mm) 1.8 lbs. (0.8 kg) G3
01871.9-30 AC 115 V, 50/60 Hz 36.5 cfm (62 m³/h) 30.0 cfm (51 m³/h) 230 mA 18 W 53 dB (A) 2.6" (66 mm) 1.8 lbs. (0.8 kg) G3
Air volume
with exhaust filter
Current consumption
(50/60 Hz)
Power
consumption
Average noise level
(DIN EN ISO 4871)
Mounting depth Weight
(approx.)
Filter mat
AIRFLOW DIRECTION "IN": EXHAUST FILTER FPI 118
Part No. Mounting depth Weight (approx.) Air outlet
11871.0-00 1.4" (35 mm) 0.7 lbs. (0.3 kg) air-flap outlet technology
4.88" (124mm)
2.6"
(66mm)
0.98"
(25 mm)
4.88" (124mm)
1.38"
(35mm)
0.98"
(25mm)
4.88" (124mm)
1.38"
4.88" (124mm)
5.98" (152mm)
2.6"
(66mm)
0.98"
(25 mm)
4.88" (124mm)
1.38"
(35mm)
0.98"
(25mm)
5.98" (152mm)
4.88
"
(124mm)
3.11"
(79mm)
0.98"
(25 mm)
4.88" (124mm)
0.98"
(25mm)
0.87"
(22mm)
4.88
"
(124mm)
3.11"
(79mm)
0.98"
(25 mm)
4.88" (124mm)
0.98"
(25mm)
0.87"
(22mm)
3.11"
4.88" (124mm)
0.98"
COOLING
28.07.2020 | Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.
SYSTEM FPO
Filter Fan FPO 018
warmcold
AIRFLOW DIRECTION "OUT": FILTER FAN FPO 018
Part No.
01881.0-00 AC 230 V, 50/60 Hz 57.1 cfm (97 m³/h) 27.7 cfm (47 m³/h) 120 mA 19 W 49 dB (A) 3.1" (79 mm) 2.0 lbs. (0.9 kg) air-flaps
01881.9-00 AC 115 V, 50/60 Hz 68.9 cfm (117 m³/h) 34.1 cfm (58 m³/h) 230 mA 18 W 52 dB (A) 3.1" (79 mm) 2.0 lbs. (0.9 kg) air-flaps
Air-flaps
Intake Filter FPO 118
Filter mat
Operating voltage Air volume, free
blowing
Air volume
with intake filter
Current consumption
(50/60 Hz)
Power
consumption
Average noise level
(DIN EN ISO 4871)
Mounting depth Weight
(approx.)
Air outlet
49
49
AIRFLOW DIRECTION "OUT": INTAKE FILTER FPO 118
Part No. Mounting depth Weight (approx.) Filter mat
11881.0-30 0.9" (22 mm) 0.4 lbs. (0.2 kg) ISO coarse 55 % acc. to ISO 16890 (G3), initial gravimetric arrestance 57 %
FILTER MAT FM 086
Filter class 4.65 x 4.65" (118 x 118 mm) Initial gravimetric arrestance 1 packing unit
ISO coarse 55% acc. to ISO 16890 (G3) Part No. 08634.0-00 57 % 5 pieces
DIMENSIONED DRAWINGS
2.6"
5.98" (152mm)
(66mm)
0.98"
(25 mm)
4.88" (124mm)
(35mm)
0.98"
(25mm)
5.98" (152mm)
(124mm)
"
4.88
(79mm)
0.98"
(25 mm)
0.87"
(22mm)
(25mm)
FPI 118FPI 018 FPO 118FPO 018
4.9" (124 mm)
4.9" (124 mm)
ENCLOSURE CUT-OUT ENCLOSURE CUT-OUT
FILTER FAN PLUS
28.07.2020 | Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.
PRODUCT CATALOG - STEGO, Inc.
FPI/FPO 018 |
up to 184.2 cfm (6.9 x 6.9")
> New air-flap outlet technology for
high airflow > Easy mounting > Protection type/Environmental
ratings by independent testing
agencies (VDE & UL)
Filter fans are used to provide "cooling" by forced air-circulation in enclosures and cabinets containing eletrical/ electronic and other components. The interior temperature of an enclosure can be reduced by channelling cooler, filtered outside air into the enclosure, thus expelling hot inside air. The resulting airflow prevents formation of localized hot pockets and protects electronic components from overheating. The Filter Fan Plus series encompasses a new air-flap technology on the air outlet side, thereby reaching an unparalleled high degree of airflow. A unique ratchet mechanism is used for easy installation. It provides safe and secure mounting while guaranteeing a tight seal. Depending on the requirements, there are two optional systems available – the FPI or the FPO system (FPI = "in", FPO = "out"). The FPI system is the more commonly known installation system, where a filter fan located in the lower part of the enclosure draws cleaner, cooler air into the enclosure (airflow direction "In"). This system consists of a filter fan and exhaust filter. On opposite, with the newer FPO system, the filter fan will be located in the upper area of the enclosure to draw warmer air out of the enclosure (airflow direction "Out"). The FPO system consists of an intake filter and exhaust filter fan. The Filter Fan Plus series may also be used outdoors with appropriate protective measures or when equipped with weather proof accessories, e.g. Hose-proof Hood FFH 086.
> Two optional systems for optimal
airflow (FPI/FPO)
> Industry-common enclosure cut-out
sizes (5 sizes)
> Single filter mat system design
TECHNICAL DATA
Axial fan, ball bearing service life L10 at +104 °F (+40 °C): min. 65,000 h
SYSTEM FPI
Exhaust Filter FPI 118
warmcold
Air-flaps
Filter Fan FPI 018
Filter mat
AIRFLOW DIRECTION "IN": FILTER FAN FPI 018
Part No. Operating voltage Air volume,
free blowing
01872.0-30 AC 230 V, 50/60 Hz 100 cfm (170 m³/h) 81.8 cfm (139 m³/h) 310/250 mA 45 W 55 dB (A) 4.6" (117 mm) 3.5 lbs. (1.6 kg) G3
01872.9-30 AC 115 V, 50/60 Hz 120 cfm (204 m³/h) 110.1 cfm (187 m³/h) 560/470 mA 38 W 58 dB (A) 4.6" (117 mm) 3.5 lbs. (1.6 kg) G3
Connection 3-pole clamp for AWG 14 (2.5 mm²), clamping torque 0.8 Nm max.
Housing, hood, flaps plastic UL 94V-0, light grey;
Enclosure cut-out 6.9 x 6.9
Mounting frame 4 built-in ratchet push levers for mounting (6 ratchet stops to
Filter mat ISO coarse 55% acc. to ISO 16890 (G3), init. grav. arrestance 57%
Filter material synthetic mesh with progressive construction,
Operating temperature 50 Hz: -13 to +122 °F (-25 to +50 °C)
Storage temperature -40 to +158 °F (-40 to +70 °C)
Operating/Storage humidity max. 90 % RH (non-condensing)
Protection type/Protection class IP54 / I (grounded)
Environmental rating UL/NEMA UL TYPE 12 / NEMA 12
Approvals UL File No. E234324, VDE, EAC
Note other voltages on request
1
Drilling hole markings for screw mounting are indicated on mounting frame.
Air volume
with exhaust filter
Current consumption
(50/60 Hz)
Power
consumption
fan body aluminum, metal impeller
UV light resistant according to UL 746C (f1)
+0.04
inches (176 x 176+1 mm)
accommodate for wall thicknesses Gauge 9 to 19 or 1-4 mm). Additional screw mounting possible if needed
temperature resistant to +212 °F (+100 °C), self-extinguishing class F1, moisture resistant to 100 % RH, reusable
60 Hz: -13 to +158 °F (-25 to +70 °C)
Average noise level
(DIN EN ISO 4871)
Mounting depth Weight
(approx.)
1
.
Filter mat
AIRFLOW DIRECTION "IN": EXHAUST FILTER FPI 118
Part No. Mounting depth Weight (approx.) Air outlet
11872.0-00 1.7" (43 mm) 0.9 lbs. (0.4 kg) air-flap outlet technology
Loading...
+ 11 hidden pages