Very low noise
Functional design
Time-saving installation
Weather proof and UV resistant
Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localized heat pock­ets and protects the electronic components from overheating. The plastic used for the hood of this filter fan series is highly weather proof, as well as impact and UV light resistant.
Axial fan, ball bearing service life min. 50,000h at 77°F (25°C) and 65% RH
aluminum fan body, plastic rotor
Connection 2 wires w/ cage clamps, AWG 14 (2.5mm²), length 4” (100mm)
Housing (filter fan and exhaust filter) Plastic, UL 94V-0, light grey
Hood (filter fan and exhaust filter) Plastic, UL 94V-0, light grey;
weather proof and UV light resistant according to UL 746C (f1)
Mounting frame with double-sided industrial adhesive for mounting to the
outside of enclosure; certain operating circumstances may
make the additional use of screws necessary; cut-out
template included
Filter media rating G4 acc. to DIN EN 779, filtering degree 94%
Filter material synthetic fiber with progressive construction, temperature
resistant to 212°F, self-extinguishing class F1;
moisture resistant to 100% RH, reusable - can be cleaned by
washing or vacuuming
Operating / Storage temperature -49 to +158°F (-45 to +70°C)
Protection class I (grounded)
Protection type IP54*
*Using fine filter media type F5 increases the protection type to IP55, but reduces the air volume
Part No.
Operating
voltage
Air volume,
free blowing
Air volume
with
exhaust filter
Power
consumption
Average noise level
(DIN EN ISO 4871)
Mounting
depth
Enclosure
cut-out
Weight
(approx.)
Approvals
01800.0-00 230VAC, 50Hz1)12 cfm (21m³/h ) 9 cfm (16m³/h) 13W 31dB (A) 1.8” (45mm) 3.8 x 3.8” 1.3 lbs. (0.60kg) UL File No. E234324, VDE
01800.0-01 120VAC, 60Hz 14 cfm (24m³/h) 11 cfm (18m³/h) 13W 31dB (A) 1.8” (45mm) 3.8 x 3.8” 1.3 lbs. (0.60kg) UL File No. E234324
01801.0-00 230VAC, 50Hz1)32 cfm (55m³/h) 25 cfm (42m³/h) 15W 40dB (A) 2.3” (58mm) 4.9 x 4.9” 2.2 lbs. (1.0kg) UL File No. E234324, VDE
01801.0-01 120VAC, 60Hz 37 cfm (63m³/h) 28 cfm (48m³/h) 15W 40dB (A) 2.3” (58mm) 4.9 x 4.9” 2.2 lbs. (1.0kg) UL File No. E234324
01802.0-00 230VAC, 50Hz1)60 cfm (102m³/h) 40 cfm (68m³/h) 15W 39dB (A) 3.4” (86mm) 6.9 x 6.9” 2.9 lbs. (1.30kg) UL File No. E234324, VDE
01802.0-01 120VAC, 60Hz 69 cfm (117m³/h) 46 cfm (78m³/h) 15W 39dB (A) 3.4” (86mm) 6.9 x 6.9” 2.9 lbs. (1.30kg) UL File No. E234324
Special features
The self-adhesive seal of the mounting frame prevents dust and water from entering the cabinet.
Functional design of the intake and exhaust fan hoods very effectively prevents direct infiltration of falling water and dust. The advantage is that the filter mat does not rapidly become contaminated with dirt
and therefore does not need to be exchanged as often.
The air channelling makes the filter fan particularly quiet in operation.
All filter fan models are also available with integrated airflow monitor.
The direction of air flow can easily be switched by reversing the axial fan.
EMC versions and other voltages are available upon request.
FF 018 Filter Fan 14 - 69 cfm
Enclosure ventilation using a filter fan and exhaust filter
1)
air volume increases by 15% when operating 230VAC filter fans at 60Hz
Ventilating
FF 018 Filter Fan 14 - 69 cfm
FF018/06-08/US
Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application.
STEGO, Inc. · 1395 South Marietta Parkway · Building 800 · Marietta, GA 30067 · Tel: (770) 984-0858 · Fax: (770) 984-0615
Toll free: 1-888-783-4611 (US & Canada only) · www.stegousa.com
Time-saving assembly and maintenance
STEGO's filter fans are easily installed by one person from outside the cabinet.
1.) Make cut-out in the cabinet wall. The cut edge of the cabinet opening should be free of dirt, filings and grease. A template for the enclosure cut-out is included with the filter fan.
2.) Remove protective film from the sealing strips on the mounting frame. Press mounting frame into the cabi­net opening. The frame stays permanently in the cabinet.
3.) Electrically connect the axial fan using the cage clamp connectors. Push the unit into the mounting frame. Affix using screws if necessary.
4.) Insert the filter mat in the hood. Clip on. Finished.
To change the filter mat, simply remove the filter hood, insert the new mat and snap the hood back again. No tools are required. Maintenance of the fan can easily be performed without removing the mounting frame (2).
Installation sketch
Dimensional Drawing
5.1”
5.3”
1.8”
3.8”
6.2”
6.7”
2.3”
4.9”
8.2”
8.9”
3.4”
6.9”
1.4”
1.6”
2.0”
Filter mat 3.5 x 3.5” (89 x 89mm) 4.6 x 4.6” (118 x 118mm) 6.6 x 6.6” (168 x 168mm)
G4 (1 packing unit = 3 pcs.) Part No. 08600.0-00 Part No. 08601.0-00 Part No. 08602.0-00 F5 (1 packing unit = 3 pcs.) Part No. 08603.0-00 Part No. 08604.0-00 Part No. 08605.0-00
Part No. Mounting depth Enclosure cut-out Weight (approx.) Filter mat Protection type Approvals
11800.0-00 0.6” (16mm) 3.8 x 3.8” 0.6 lbs. (0.30kg) G4 acc. to DIN EN 779, filtering degree 94% IP54* UL File No. E234324
11801.0-00 0.6” (16mm) 4.9 x 4.9” 0.8 lbs. (0.40kg) G4 acc. to DIN EN 779, filtering degree 94% IP54* UL File No. E234324
11802.0-00 0.6” (16mm) 6.9 x 6.9” 1.3 lbs. (0.60kg) G4 acc. to DIN EN 779, filtering degree 94% IP54* UL File No. E234324
For technical data regarding the integrated Airflow Monitor, please see LC 013/LCF 013 (Normally Closed, Normally Open)
Drilling template for mounting frame
Part No.
Operating
voltage
Air volume,
free blowing
Air volume
with exhaust filter
Power
consumption
Average noise level
(DIN EN ISO 4871)
Depth in
enclosure
Enclosure
cut-out
Weight
(approx.)
21800.0-00 230VAC, 50Hz1)12 cfm (21m³/h ) 9 cfm (16m³/h) 13W 31dB (A) 1.8” (45mm) 3.8 x 3.8” 1.3 lbs. (0.60kg)
21800.0-01 120VAC, 60Hz 14 cfm (24m³/h) 11 cfm (18m³/h) 13W 31dB (A) 1.8” (45mm) 3.8 x 3.8” 1.3 lbs. (0.60kg)
21801.0-00 230VAC, 50Hz
1)
32 cfm (55m³/h) 25 cfm (42m³/h) 15W 40dB (A) 2.3” (58mm) 4.9 x 4.9” 2.2 lbs. (1.0kg)
21801.0-01 120VAC, 60Hz 37 cfm (63m³/h) 28 cfm (48m³/h) 15W 40dB (A) 2.3” (58mm) 4.9 x 4.9” 2.2 lbs. (1.0kg)
21802.0-00 230VAC, 50Hz1)60 cfm (102m³/h) 40 cfm (68m³/h) 15W 39dB (A) 3.4” (86mm) 6.9 x 6.9” 2.9 lbs. (1.30kg)
21802.0-01 120VAC, 60Hz 69 cfm (117m³/h) 46 cfm (78m³/h) 15W 39dB (A) 3.4” (86mm) 6.9 x 6.9” 2.9 lbs. (1.30kg)
*using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
5.4” (137 mm)
5.4” (137 mm)
Ø1/8” (3mm)
7.4” (188 mm)
7.4” (188 mm)
4.3” (109 mm)
4.3” (109 mm)
Ø1/8” (3mm)
Ø1/8” (3mm)
EF 118 Exhaust Filter
FFLC 218 Filter Fan with Airflow Monitor (Normally Closed)
FM 086 / FFM 086 Filter Mats
Airflow monitor integrated in finger guard of filter fan (Part No. 21800.0-00 shown)
1)
air volume increases by 15% when operating 230VAC filter fans at 60Hz
Loading...