HIGH-PERFORMANCE FAN HEATER
18.02.2020 | Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.
PRODUCT CATALOG - STEGO, Inc.
DCR 030 |
5.71" (145mm)
5.12" (130mm)
DC 24 V, DC 56 V – 200 W to 800 W
> High DC heating performance
> Integrated adjustable thermostat or
hygrostat
> Small hysteresis
The compact high performance fan heater DCR 030 prevents formation of condensation and frost and provides
an evenly distributed interior air temperature in enclosures with electric/electronic components. The fan heater is
available with an integrated electronic thermostat or integrated electronic hygrostat. The model with thermostat
is available with internal or external sensor. The fan heater with integrated hygrostat is equipped with an external
sensor. The external sensor can be positioned freely anywhere in the enclosure for precise measurements of temperature and humidity. The DCR 030 was designed as a stationary unit for the bottom of the enclosure. For wall fixing
the fan heater DCR 130 is recommended.
TECHNICAL DATA
Heating element high performance cartridge
Overheat protection with automatic reset and second-tier one shot fuse to protect
3.94" (100mm)
4.13" (105mm)
6.51" (166mm)
Heater body extruded aluminium profile
Axial fan, ball bearing service life 50,000 h at +77 °F (+25 °C)
Air flow, free blowing 94 cfm (160 m³/h)
Connection 2-pole „Push-In“ connection clamp stranded wire
Housing plastic, UL 94V-0, black
Mounting M5 screws and washers (not included), torque 2 Nm max.
Mounting position vertical airflow (air outlet up)
Dimensions 3.9 x 5.7 x 6.5" (100 x 145 x 166 mm)
Weight approx. 2.86 lbs. (1.3 kg)
Operating temperature -4 to +167 °F (-20 to +75 °C)
Storage temperature -40 to +176 °F (-40 to +80 °C)
Operating / Storage humidity max. 90 % RH (non-condensing)
Protection type / Protection class IP20 / II (double insulated)
Approvals UL File No. E234324, VDE, EAC
Note other versions (heating capacities, setting ranges) as well as
¹ When connecting with stranded wires, wire end ferrules must be used.
> Integrated switch module
> Screw mounting
> Optical indicator (LED)
against overheating in case of fan failure
(1.5 mm²) with strain relief; max. AWG 12 (2.5 mm²)
operating voltage DC 48 V on request
1
AWG 16
Wiring diagram
M
INT
EXT
39
18.02.2020 | Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.
39
Part No. Model Operating voltage
03092.1-16 Fan heater with integrated thermostat
with internal temperature sensor
03092.1-17
03097.3-16 Fan heater with integrated thermostat with
03097.3-17 Fan heater with integrated thermostat with
03092.1-03 Fan heater with integrated hygrostat with
03095.3-03 Fan heater with integrated hygrostat with
Fan heater with integrated thermostat with
connector for external temperature sensor²
internal temperature sensor
connector for external temperature sensor²
connector for external humidity sensor²
connector for external humidity sensor²
DC 24 V
DC 24 V
DC 56 V
DC 56 V
DC 24 V
DC 56 V
Heating capacity Recommended pre-fuse T
200 W 25.0 A -4 to 104 °F
200 W 25.0 A
800 W 25.0 A -4 to 104 °F
800 W 25.0 A -4 to 104 °F
200 W 25.0 A 40 to 90 % RH
600 W 25.0 A 40 to 90 % RH
(time-delay)
temperature / humidity
² The external sensor needs to be ordered separately.
³ Switching difference temperature: 3 K (±1 K tolerance) at +77 °F (+25 °C), 50 % RH; Switching difference humidity: 4 % RH (±1 % tolerance) at +77 °F (+25 °C), 50 % RH.
ACCESSORIES
The external sensor is not included in the delivery of the DCR 030. It can be ordered separately.
EXTERNAL SENSOR
The external sensor can be positioned freely anywhere in the enclosure for precise measurements of temperature and humidity.
Setting range3
-4 to 104 °F
Part No. Length
267071 3.28 ft (1 m)
267072
267126 9.84 ft (3 m)
6.56 ft (2 m)