PTC FAN HEATER
18.02.2020 | Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.
PRODUCT CATALOG - STEGO, Inc.
CSF 028 |
CSF 028 with DIN clip
CSF 028 with screw mount tabs
250 W, 400 W
> Compact size > Integrated pre-set thermostat > Quiet operation
> Heating power adjusts to ambient
temperature
> DIN rail or screw tab mount available
The CSF 028 fan heater prevents formation of condensation and provides evenly distributed interior air temperature in enclosures. The touch-safe plastic housing and the small size makes it ideal for use in enclosures with a high packing density. The heater is equipped with a fixed set point thermostat and is easily wired via external pressure clamps. Two different mounting options are available – DIN rail or screw tabs. The robust screw tab mounting is particularly suitable for applications with high vibration.
TECHNICAL DATA
Heating element PTC resistor, temperature limiting
Overheat protection built-in temperature limiter
Axial fan, ball bearing service life 40,000 h at 104 °F (+40 °C)
Axial fan, free blowing 32 cfm (54 m³/h) @ AC 120 V
Connection 2-pole dual pressure clamp for solid wire AWG 14 max. (2.5mm²),
Housing plastic, UL 94V-0, black
Mounting clip for 35 mm DIN rail, EN 60715 or screw mount (Ø 5.5 mm),
Mounting position vertical airflow (air outlet up)
Dimensions models with DIN clip: 4.13 x 3.35 x 4.65" (105 x 85 x 118 mm),
Weight 17.6 oz. (500 g)
Operating / Storage temperature -40 to +158 °F (-40 to +70 °C) / -49 to +158 °F (-45 to +70 °C)
Operating / Storage max. 90 % RH (non-condensing)
Protection class / Protection type II (double insulated) / IP20
26 cfm (45 m³/h) @ AC 230 V
stranded wire (with wire end ferrule) AWG 16 max. (1.5 mm²)
clamping torque 2 Nm max., washers must be used
models w/ screw tabs: 4.13 x 4.53 x 4.25" (105 x 115 x 108 mm)
Part No.
DIN mount
02821.9-06 02821.9-08 AC 120 V, 50/60 Hz 250 W 6.0 A 10.0 A 59 °F (15 °C) 41 °F (5 °C) UL File No. E234324 - EAC
02821.9-09 02821.9-11 AC 120 V, 50/60 Hz 250 W 6.0 A 10.0 A 77 °F (25 °C) 59 °F (15 °C) UL File No. E234324 - EAC
02820.9-06 02820.9-08 AC 120 V, 50/60 Hz 400 W 9.0 A 10.0 A 59 °F (15 °C) 41 °F (5 °C) UL File No. E234324 - EAC
02820.9-09 02820.9-11 AC 120 V, 50/60 Hz 400 W 9.0 A 10.0 A 77 °F (25 °C) 59 °F (15 °C) UL File No. E234324 - EAC
02821.0-06 02821.0-08 AC 230 V, 50/60 Hz 250 W 9.0 A 10.0 A 59 °F (15 °C) 41 °F (5 °C) UL VDE EAC
02821.0-09 02821.0-11 AC 230 V, 50/60 Hz 250 W 9.0 A 10.0 A 77 °F (25 °C) 59 °F (15 °C) UL VDE EAC
02820.0-06 02820.0-08 AC 230 V, 50/60 Hz 400 W 15.0 A 16.0 A 59 °F (15 °C) 41 °F (5 °C) UL VDE EAC
02820.0-09 02820.0-11 AC 230 V, 50/60 Hz 400 W 15.0 A 16.0 A 77 °F (25 °C) 59 °F (15 °C) UL VDE EAC
¹ at 68 °F (20 °C) ambient temperature; ² tolerance of ±5 K
Note: Other Switch-off and Switch-on temperatures on request.
Part No.
screw tab mount
Operating
voltage
Heating
Inrush current
max.
Recommended
pre-fuse
T (time-delay)
Switch-off
temperature²
Switch-on
temperature²
Approvals
4.53“ (115mm)
1.77” (45mm)
DIMENSIONED DRAWINGS
18.02.2020 | Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.
HEATING
27
27
DIN RAIL MOUNT
3.35“ (85mm)
3.54“ (90mm)
4.13“ (105mm)
4.45“ (113mm)
4.65“ (118mm)
View: back side
SCREW TAB MOUNT
3.35“ (85mm)
Wiring example
Fan heater CSF 028
3.54“ (90mm)
4.13“ (105mm)
4.06“ (103mm)
4.25“ (108mm)
View: back side
4.06” (103mm)
Heating Power (W)
Ambient Temperature
ACCESSORIES
Air guide for improved heat distribution
The air guide is an accessory part for use with the fan heater CSF 028. It can easily be clipped onto the protective grill of the fan heater without use of any tools, and diverts the exiting warm air by 45°. This results in an overall improved heat distribution within an enclosure or cabinet. The temperature above the protective grill is reduced by up to 68 °F/20 °C (measured approx. 3.9”/100 mm above protective grille) and may make the use of custom heat ducts obsolete.
Part No. Dimensions² Plastic 1 Packing unit Weight (approx.)
252017 3.3 x 3.3 x 0.5“ (85 x 85 x 12 mm) UL 94V-0, black 1 piece 1.2 oz. (35 g)
2
Dimensions when mounted on fan heater.
Air guide Part No. 252017
Fan heater with air guide