![](/html/1a/1a43/1a4341306b387e0d45e176d07e1269ee4b2bca6530a03f7c4d0618afdf530890/bg1.png)
Owner's Henuel
91)01)
It Generator
_iiiii
SP-GGgOOE
tonSEnVlCECALL:888-89S-S881
PARA SERVICIO LLAME:
![](/html/1a/1a43/1a4341306b387e0d45e176d07e1269ee4b2bca6530a03f7c4d0618afdf530890/bg2.png)
Topic Page
Limited Warranty 2
Safety Guidelines 4
General Precautions 5
Battery 11
Assembly 12
Operation 15
Inspection, Cleaning and Maintenance 19
Installation 20
Compliance 21
Specifications 22
Parts List 23
_ WARNING! READ AND UNDERSTAND ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE
OPERATING. FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL
INJURY, PROPERTY DAMAGE, AND/OR VOIDING OFYOUR WARRANTY. STEELE® PRODUCTS WILL NOT
BE LIABLE FORANY DAMAGE BECAUSE OF FAILURE TO FOLLOW THESE INSTRUCTIONS.
![](/html/1a/1a43/1a4341306b387e0d45e176d07e1269ee4b2bca6530a03f7c4d0618afdf530890/bg3.png)
Steele@warrantsto the originalpurchaserwhousestheproductin aconsumerapplication(personal,
residentialor householdusage)thatall productscoveredunderthis warrantyarefreefrom defectsin
materialandworkmanshipfor oneyearfromthedateof purchase.All productscoveredbythis limited
warrantywhichareusedin commercialapplications(i.e.incomeproducing)arewarrantedto befreeof
defectsin materialandworkmanshipfor 90daysfrom thedateof originalpurchase.Productscoveredunder
thiswarrantyincludeaircompressors,air tools,serviceparts,pressurewashersandgenerators.
Steele@will repairor replace,at Steele's@soleoption,productsor componentswhichhavefailedwithinthe
warrantyperiod.Servicewill bescheduledaccordingto thenormalworkflow andbusinesshoursatthe
servicecenterlocation,andtheavailabilityof replacementparts.Alldecisionsof Steele@with regardtothis
limitedwarrantyshallbefinal.
Thiswarrantygivesyouspecificlegalrights,andyoumayalsohaveotherrightswhichvaryfrom stateto
state.
RESPONSIBILITYOFORIGINALPURCHASER(initial User):
Toprocessa warrantyclaimonthis product,DONOTreturnitemto theretailer.Theproductmustbe
evaluatedbyanAuthorizedWarrantyServiceCenter.Forthe locationofthenearestAuthorizedWarranty
ServiceCentercontacttheretaileror placeofpurchase.
Retainoriginalcashregistersalesreceiptasproofof purchasefor warrantyto work.
Usereasonablecarein theoperationandmaintenanceoftheproductasdescribedin theOwner'sManual(s).
Deliverorshiptheproductto theAuthorizedWarrantyServiceCenter.Freightcosts,if anymust bepaidby
thepurchaser.Ifthe purchaserdoesnotreceivesatisfactoryresultsform theAuthorizedWarrantyService
Center,thepurchasershouldcontactSteele@toll free888-896-6881.
THISWARRANTYDOESNOTCOVER:
Merchandisesoldas reconditioned,usedasrentalequipment,orflooror displaymodels.
Merchandisethathasbecomedamagedorinoperativebecauseof ordinarywear,misuse,cold,heat,rain,
excessivehumidity,freezedamage,useof improperchemicals,negligence,accident,failureto operatethe
productin accordancewiththeinstructionsprovidedintheOwner'sManual(s)suppliedwiththeproduct,
impropermaintenance,theuseofaccessoriesorattachmentsnot recommendedbySteele@,or
unauthorizedrepairoralterations.
oRepairandtransportationcostsof merchandisedeterminenot to bedefective.
Costsassociatedwithassembly,requiredoil,adjustmentsorotherinstallationandstart-upcosts.
Expendablepartsor accessoriessuppliedwiththeproductwhichareexpectedto becomeinoperativeor
unusableaftera reasonableperiodof use.
![](/html/1a/1a43/1a4341306b387e0d45e176d07e1269ee4b2bca6530a03f7c4d0618afdf530890/bg4.png)
MerchandisesoldbySteele@whichhasbeenmanufacturedbyandidentifiedas theproductof another
company,suchasgasolineengines.Theproductmanufacturer'swarranty,if any,willapply.
ANYINCIDENTAL,INDIRECTORCONSEQUENTIALLOSS,DAMAGE,OREXPENSETHATMAYRESULT
FROMANYDEFECTS,FAILUREORMALFUNCTIONOFTHEPRODUCTISNOTCOVEREDBYTHIS
WARRANTY.Somestatesdonotallowtheexclusion,so it maynotapplyto you.
IMPLIEDWARRANTIES,INCLUDINGTHOSEOFMERCHANTABILITYORFITNESSFORA PARTICULAR
PURPOSE,ARELIMITEDTOONEYEARFROMTHEDATEOFORIGINALPURCHASE.Somestatesdonot
allowlimitationsonhowlonganimpliedwarrantylasts,sotheabovelimitationsmaynot applytoyou.
![](/html/1a/1a43/1a4341306b387e0d45e176d07e1269ee4b2bca6530a03f7c4d0618afdf530890/bg5.png)
Thismanualcontainsimportantinformationthatyou needto knowandunderstandinorderto keepYOU
SAFEandto PREVENTEQUIPMENTPROBLEMS.Thefollowingsymbolshelpyou recognizethis information.
Pleasereadthemanualandpayattentiontothesesections.
SaveTheseImportantSafetyinstructions!Readandunderstandallof thesesafetyinstructions. Be sure to
retain them for future use.
_ WARNING! Warnings indicate a certainty or strong possibility of personal injury or death if
instructions are not followed.
J_ CAUTION Cautions indicate a possibility of equipment damage if instructions are not followed
,_ NOTE: Notes give helpful information
,_ WARNING! Improper operation or maintenance of this product could result in serious injury an
property damage, Read and understand all warnings and operating Instructions before using this equipment.
When using air tools, basic safety precautions should always be followed to reduce the risk of personal
injury.
![](/html/1a/1a43/1a4341306b387e0d45e176d07e1269ee4b2bca6530a03f7c4d0618afdf530890/bg6.png)
Owner's Manua!
Gener Precautions
,_ WARNING! Failure to follow these instructions can result in severe injury or death.
DANGER!
Carbon Monoxide
Using a generator induurs WILL KILL YOU IN MINUTES.
Carbon Monoxide
Generator exhaust contains high levels of carbon monoxide (CO), a poisonous gas you cannot see or smell,
If you can smell the generator exhaust, you are breathing CO, But even If you cannot smell the exhaust, you
could be breathing CO,
• NEVER use a generator inside homes, garages, crawlspaces, or other partly enclosed areas. Deadly levels
of carbon monoxide can build up in these areas. Using a fan or opening windows and doors does NOT
supply enough fresh air.
• ONLY use a generator outdoors and far away from open windows, doors, and vents. These openings can
pull in generator exhaust.
Even when you use a generator correctly, CO may leak into the home. ALWAYS use a battery-powered or
battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air RIGHT AWAY.
See a doctor. You could have carbon monoxide poisoning.
Gasoline and Oil
This product requires oil and fuel, Attempting to start the engine without oil will ruin the engine and void the
warranty, Work in well ventilated area, Keep cigarettes, flames or sparks away from the work area or where
gasoline is stored,
_ WARNING! Gasoline is extremely flammable and is explosive under certain conditions. Keep out of
reach of children.
Gasoline fuel and fumes are flammable and potentially explosive, Use proper fuel storage and handling
procedures, Always have multiple ABC class fire extinguishers nearby,
Keep the generator and surrounding area clean at all times.
Fuel or oil spills must be cleaned up immediately, Dispose of fluids and cleaning materials as per any local,
state, or federal codes and regulations, Store oily rags in a covered metal container,
o Never store fuel or other flammable materials near the generator.
![](/html/1a/1a43/1a4341306b387e0d45e176d07e1269ee4b2bca6530a03f7c4d0618afdf530890/bg7.png)
Donot smoke,orallowsparks,flamesor othersourcesofignitionaroundtheengineandfueltank.Fuel
vaporsareexplosive.
Keepgroundedconductiveobjects,suchastools,awayfrom exposed,liveelectricalpartsand connections
to avoidsparkingor arcing.Theseeventscouldignitefumesorvapors.
Donot refillthefueltankwhilethe engineis runningorwhiletheengineisstill hot.Donot operatethe
generatorwithknownleaksin thefuel system
Excessivebuildupof unburnedfuelgasesinthe exhaustsystemcancreateapotentiallyexplosivecondition.
Thisbuildupcanoccurafterrepeatedfailedstartattempts,valvetesting,or hotengineshutdown,Ifthis
occurs,openexhaustsystemdrainplugs,if equipped,andallowthe gasesto dissipatebeforeattemptingto
restartthegenerator.
Useonlyenginemanufacturerrecommendedfuelandoil.
HotComponents
,_ WARNING! Engine and exhaust system parts become very hot and remain hot for some time after the
engine is run. Wear insulated gloves or wait until the engine and exhaust system have cooled before
handling these parts.
WorkArea
Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents.
Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases,
or dust. Generators create sparks which may ignite the dust or fumes.
Keep bystanders, children, and visitors away while operating a generator. Provide barriers or shields as
needed.
Electrical Safety
Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all
codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any
adapter plugs.
Grounding provides a low=resistance path to carry electricity away from the user in the event of an electrical
malfunction.
Double insulated tools are equipped with a polarized plug where one blade is wider than the other. This plug
fits in a polarized outlet only one way, If the plug does not fit fully in the outlet, reverse the plug, If it still
does not fit, contact a qualified electrician to install a polarized outlet, Do not change the plug in any way.
Double insulation eliminates the need for the three-wire grounded power cord and grounded power supply
system.
![](/html/1a/1a43/1a4341306b387e0d45e176d07e1269ee4b2bca6530a03f7c4d0618afdf530890/bg8.png)
Avoidbodycontactwith groundedsurfacessuchaspipes,radiators,ranges,andrefrigerators.Thereis an
increasedriskofelectricshockif your bodyis grounded.
Donot exposegeneratorto rainorwetconditions.Waterenteringa generatorwill increasetherisk of
electricshock.
Donot abusethepowercord.Keeppowercordsawayfrom heat,oil, sharpedges,or movingparts.Replace
damagedpowercordsimmediately.Damagedpowercordsincreasethe riskof electricshock.
Whenoperatingapowertooloutside,useanoutdoorextensioncordmarked"W-A"or "W".Theseextension
cordsareratedfor outdooruse,andreducethe riskof electricshock.
All connectionsandconduitsfrom thegeneratorto the loadmustonlybeinstalledbytrainedandlicensed
electricians,andincompliancewith all relevantlocal,state,andfederalelectricalcodesandstandards,and
otherregulationswhereapplicable.
Thegeneratormustbeearth-groundedfor fixedinstallationsinaccordancewithall relevantelectricalcodes
andstandardsbeforeoperation.
Donot attemptto connector disconnectloadconnectionswhilestandinginwater,orwetor soggyground.
Donot touchelectricallyenergizedpartsofthe generatorandinterconnectingcablesor conductorswith any
partof thebody,or withanynon-insulatedconductiveobject.
Connectthegeneratoronlytoaloador electricalsystem(110/120volt)thatiscompatiblewith theelectrical
characteristicsandratedcapacitiesof thegenerator.
Beforeservicingequipmentpoweredbythe generator,disconnectthe equipmentfrom its powerinput.
Keepallelectricalequipmentcleananddry. Replaceanywiringwheretheinsulationiscracked,cutabraded
or otherwisedegraded.Replaceterminalsthatareworn,discolored,orcorroded.Keepterminalscleanand
tight.
Insulateallconnectionsanddisconnectedwires.
Guardagainstelectricshock.Preventbodycontactwithgroundedsurfacessuchaspipes,radiators,ranges,
andrefrigeratorenclosures.
PersonalSafety
Stay alert. Watch what you are doing, and use common sense when operating agenerator. Do not use
generator while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while
operating generators may result in serious personal injury.
![](/html/1a/1a43/1a4341306b387e0d45e176d07e1269ee4b2bca6530a03f7c4d0618afdf530890/bg9.png)
Dressproperly.Donotwearlooseclothingor jewelry.Containlonghair.Keepyour hair,clothing,andgloves
awayfrom movingparts.Looseclothes,jewelry,or longhaircanbecaughtin movingparts.
Avoidaccidentalstarting.Makesurethepowerswitchisin its "OFF"position,anddisconnectthesparkplug
wirewhennot in use.
Removeadjustingkeysorwrenchesbeforeturningthegeneratoron. Awrenchora keythatis leftattached
to a rotatingpartof thegeneratormayresultin personalinjury.
Donot overreach.Keepproperfootingandbalanceatalltimes.
Usesafetyequipment.Alwaysweareyeprotection.WearANSIapprovedsafetyimpacteyegoggles.Dust
mask,non-skidsafetyshoes,hardhat,or hearingprotectionmustbeusedfor appropriateconditions.
Donotforcethegenerator.Usethecorrectgeneratorfor yourapplication.Thecorrectgeneratorwill dothe
job betterandsaferatthe ratefor whichit is designed.
Donot usethegeneratorif thepowerswitchdoesnotturn it onoroff.Anygeneratorthatcannotbe
controlledwiththepowerswitchisdangerousandmustbereplaced.
Generator Use and Care
Make sure the power switch is in its "OFF" position and disconnect the spark plug wire before making any
adjustment, changing accessories, or storing the generator. Such preventive safety measures reduce the risk
of starting the generator accidentally.
Store idle generators out of reach of children and other untrained persons. Generators are dangerous in the
hands of untrained users.
Maintain generators with care. Do not use damaged generator. Tag damaged generators "Do not use" until
repaired.
Check for misalignment or binding of moving parts, breakage of parts, and any other condition that may
affect the generator's operation. If damaged, have the generator serviced before using. Many accidents are
caused by poorly maintained generators.
Use only accessories that are recommended by the manufacturer for your model. Accessories that may be
suitable for one generator may become hazardous when used on another generator.
Servicing
Maintain labels and name plates on the generator and engine. These carry important information. If
unreadable or missing, contact Steele® immediately for a replacement.
Generator service must be performed only qualified repair personnel. Service or maintenance performed by
unqualified personnel could result in a risk of injury.
![](/html/1a/1a43/1a4341306b387e0d45e176d07e1269ee4b2bca6530a03f7c4d0618afdf530890/bga.png)
Whenservicingagenerator,useonlyidenticalreplacementparts.Followall appropriateinstructionsinthis
manual.Useof unauthorizedpartsor failuretofollow maintenanceinstructionsmaycreatea riskof electric
shockor injury.
HeartPacemakers
_ WARNING! People with pacemakers should consult their physician(s) before using this product.
Electromagnetic fields in close proximity to a heart pacemaker could cause interference to or failure of the
pacemaker.
installation
Ensure installation meets all applicable safety, and local and national electrical codes. Have installation
performed by a qualified, licensed electrician and building contractor.
All electrical work, including the earth-ground connection, should be completed by a licensed electrician.
Any separate fuel storage or generator supply facility must be built or installed in full compliance with all
relevant local, state, and federal regulations.
If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. It should not
be run outdoors without protection to the generator and wiring conduit.
The generator weighs 220 Ibs. Two or more people should assist when moving or lifting this product. Never
lift the generator using the engine or alternator lifting lugs. Connect lifting equipment to the frame of the
generator.
Before lifting the generator, ensure the lift rigging and supporting structure are in good condition, and are
rated to lift such a load.
Keep all personnel away from the suspended generator during relocating.
The supporting floor/ground surface should be level and strong enough to safely hold the weight of the
generator. If the floor/grounded surface is not level, strong cross members should be placed under the full
length of the generator frame at its low side.
For trailer installation, the generator should be mounted on the center point of the trailer, over the wheels.
The trailer must be capable of supporting the weight of the generator and all contents (tools, etc.)
Install sound-and weather-proofing only when it is not raining or snowing to avoid trapping moisture within
the generator's area.
Mechanical
Always make sure the power switch is in its "OFF" position. Disconnect the spark plug wire, and allow the
engine to completely cool before carrying out maintenance.
![](/html/1a/1a43/1a4341306b387e0d45e176d07e1269ee4b2bca6530a03f7c4d0618afdf530890/bgb.png)
Checkfor damagedparts.Beforeusingthegenerator,anypartthatappearsdamagedshouldbecarefully
checkedto determinethatit will operateproperlyandperformits intendedfunction.Checkfor alignmentand
bindingof movingparts,anybrokenpartsor mountingfixtures,andanyotherconditionthat mayaffect
properoperationtechnician.
Thegeneratorisdesignedwith guardsfor protectionfrom movingparts.Inanycase,caremuststill betaken
to protectpersonnelandequipmentfrom othermechanicalhazardswhenworkingaroundthegenerator.
Donot operatethegeneratorwith safetyguardsremoved.Whilethegeneratoris running,donotattemptto
reacharoundthesafetyguardfor maintenanceor anyotherreason.
Keephands,arms,long hair,looseclothing,andjewelryawayfrom movingparts.Beawarethatwhenengine
partsaremovingfasttheycannotbeseenclearly.
Keepaccessdoorsonenclosuresclosedandlockedwhenaccessisnot required.
Whenworkingonor aroundthegeneratoralwayswearprotectiveclothingincludingANSIapprovedsafety
gloves,safetyeyegoggles,andsafetyhat.
Donot alteroradjustanypartof thegeneratorthatis assembledandsuppliedbythe manufacturer.
Alwaysfollowandcompletescheduledengineandgeneratormaintenance.
Chemicals
Avoid contact with hot fuel, oil, exhaust fumes, and hot solid surfaces.
Avoid body contact with fuels, oils, and lubricants used in the generator. If swallowed, seek medical
treatment immediately. Do not induce vomiting if fuel is swallowed. For skin contact, immediately wash with
soap and water. For eye contact, immediately flush eyes with clean water and seek medical attention.
Noise
Prolonged exposure to noise levels above 85 DBA is hazardous to hearing. Always wear ANSI approved ear
protection when operating or working around the generator when it is running.
Extension Cord
If an extension cord (not included) is used, make sure to use only UL approved cords having the correct
gauge and length according to the following table:
Nameplate Amps _ Cord Lengths_
(@full load) 0'-50' 20'-100' 100'-150' 150'-200'
O- 5 16AWG 16AWG 12AWG 12AWG
5.1 - 8 16AWG 14AWG 10AWG
8.8 - 12 14AWG 12AWG
![](/html/1a/1a43/1a4341306b387e0d45e176d07e1269ee4b2bca6530a03f7c4d0618afdf530890/bgc.png)
Ma.ua]
Battery
Assembly
To start generator with electric start you will need a battery (not included). You can use a 12v lawn
tractor battery with the following specifications:The dimensions are Wx7.5" Dx5" Hx7"(including
terminals). A rated cranking amperage of 200. Terminals are regular, not reversed. Note: Using a
battery not designed for this unit may void warranty. Also this generator can also be started with
the pull start.
Photos below demonstrate how to install the battery.
1) Screw of the IVI6x12 bolts as shown below.
Open up the plate
2) Screw on one bolt to rivet the battery and screw the bolts to close up the plate as shown below.
Rivet battery Close up the plate
Connect battery and put in the cabin
![](/html/1a/1a43/1a4341306b387e0d45e176d07e1269ee4b2bca6530a03f7c4d0618afdf530890/bgd.png)
Assembly
Unpacking
1. Remove the generator and loose parts box from the carton.
2. Compare the loose parts with the inventory list below.
Loose Parts(Wheel kit and handle)
Check all loose parts against the following list. Contact your dealer toll free at 888.896.6881
if any of the loose parts shown are not included with your generator
HardwareCheck:
Your Hardware Kit should include:
1) 2 Handles with bolts and brackets
2) 4 (six) MSx4Omm bolts, (6mm x 1.0) thread
3) 4 (six) M8 Nuts (6mm x 1.0) thread
4) 2 (two) rubber bushings with 2 nuts
5) 2 (two) axle shafts
6) 2 (two) washers
7) 4 (four) cotter pins
8) 4 (four) bolts and nuts
9) 1 (one) generator leg
10) 2 (two) wheels (not shown)
Manua!
@@@@
5
D ]
@@@@