1. Set base unit in place and mark locations for
floor anchors. Set unit aside.
NOTE: Consult the building's Engineer of Record
to specify the correct fasteners for attachment to
the building and to ensure that the building has
adequate structure.
2. Install floor anchors per the fastener
manufacturer's specifications. Leave 2-1/4"
of exposed stud for leveling purposes.
3. Thread a nut, then a washer on each
anchor as shown.
4. Set unit on floor anchors. Plumb and
level base unit using the nuts and washers.
5. Secure the unit with a washer, lock washer
and nut, as shown, to secure the plate. Check for plumb and level.
1
3
5
CROSS SECTION
OF FINAL ORDER
MARK HOLE LOCATIONS
NUT
LOCK WASHER
WASHER
FLOOR ANCHOR
NUT
NUT
LOCK WASHER
WASHER
WASHER
FLOOR ANCHOR
PLATE
MFG. RECOMMENDED NUT / WASHER
FLOOR
ANCHOR
Page 3
Page 3 of 15
939549943 Rev G
6. Attach the cantilevers for top installation as
shown (6a) and secure to unit using three (3)
bolts per cantilever (6b).
If installing a transaction top, use the smaller
cantilever (6c).
6a
6b
6c
16" LONG STRAP
36" LONG STRAP
Page 4
Page 4 of 15
939549943 Rev G
7. After holes for floor power are located, install floor
power cable column.
Place the two sides of cable column next to each other
and snap a push rivet into the top two holes (7a). Place
each cable column floor clip as shown (7b). Mark each
hole on each cable column floor clip (7c). Remove cable
column floor clips and cable columns. Drill 3/8" x 5/8"
deep holes and install floor anchors per manufacturer's
specifications (7d).
8. Position cable column floor clips and cable
columns back into place. Secure clips to floor by
installing two (2) sems screws (with lock
washer) for each clip.
CABLE COLUMN FLOOR CLIP
CABLE COLUMN
7a
7b
7c
8
HOLE FOR
FLOOR POWER
7d
PUSH RIVET
1-1/16"
2-1/2"
11-7/8”
10-1/2”
5-13/16”
FLOOR ANCHOR
MARK HOLE
LOCATIONS
SEMS SCREW (WITH LOCK WASHER)
Page 5
Page 5 of 15
939549943 Rev G
9. Lower multipurpose bracket into place, as shown.
10. Secure multipurpose bracket to upper support with
self-tapping screws. Attach cable tray to multipurpose
bracket with screws, as shown.
NOTE: J-boxes or fasteners are not supplied and
can be installed later. Multipurpose bracket has
mounting holes for standard J-boxes.
9
10
5-1/2"
6-1/2"
CABLE TRAY
MULTIPURPOSE
BRACKET
UPPER SUPPORT
WELDMENT
MULTIPURPOSE BRACKET
2-11/16" INSIDE FACEPLATE TO MULTIPURPOSE
BRACKET
CABLE TRAY
MULTIPURPOSE BRACKET
FACEPLATE
NOTE: Blunt J-box screws
not to exceed 1/2" long.
36-3/4", 49-1/4" or 61-3/4"
INSIDE MOUNTING
DISTANCE DEPENDING
ON WIDTH OF PRODUCT
CABLE TRAY
MULTIPURPOSE BRACKET
5-1/2”
Page 6
Page 6 of 15
939549943 Rev G
11. All electrical connections should
be made at this point by a licensed electrician according to the local electrical codes (i.e. junction boxes, receptacles, conduit).
12. Install CPU's by installing the CPU
mount plates. Place each CPU mount plate between the faceplate and faceplate support bracket, as shown (12a). Turn each plate downward (12b) and into a horizontal position (12c).
12a
12b
12c
12-3/16"
J-BOX MOUNTING
RANGE ON INSIDE
OF LEG
CPU MOUNT
PLATE
FACEPLATE
FACEPLATE
SUPPORT BRACKET
Page 7
Page 7 of 15
939549943 Rev G
• Align j-boxes to the mounting holes on furniture covers and measure the distance between the j-boxes to determine conduit length.
• Once conduit length is determined, assemble and wire the entire assembly in preparation for mounting onto Sync bench. Leave enough flex conduit length and wire running out of flex conduit to allow attachment to another j-box mounted on the leg or to the floor.
NOTE: The Sync furniture faceplate is a UL approved faceplate. Electrician does NOT need to supply.
NOTE: FACEPLATE IS SHOWN REMOVED FROM BASE UNIT FOR REFERENCE. DO NOT REMOVE FACEPLATE FROM BASE UNIT.
1/2 or 3/4 CONDUIT
EMT CONNECTOR
3" x 2" x 2-1/2" SWITCH BOX
CONDUIT
GROUNDING TAB
GROUNDING TAB
Page 8
Page 8 of 15
939549943 Rev G
• Position j-box assembly onto the faceplate cover and mount assembly to the faceplate. NOTE: The outermost holes are used, with the supplied stainless steel screws, to attach the faceplate to the outlets.
• Install the multi-purpose brackets behind the electrical assembly and attach using blunt screw from back side of multi-purpose bracket into the back of the j-boxes.
MOUNTING LOCATION OF
RECEPTACLE TO FACEPLACE
Page 9
Page 9 of 15
939549943 Rev G
• Finish by securing the set screws for the multi-purpose brackets to keep secure to the faceplate support bracket.
• 4 x 4 j-boxes can be attached to the inside of each leg for additional receptacle locations. These j-boxes can be mounted flat to the leg or mounted perpendicular for extra receptacles. The flex conduit from the desk height assembly can be mounted to these j-boxes or directly to the building power sources.
• The type and amount of circuits is determined by the electrical engineer or customer and is only limited to the size and type of electrical hardwire devices used by the electrician and dictated by the local codes.
J-BOXES MOUNTED
FLAT TO THE LEG
J-BOXES MOUNTED
PERPENDICULAR TO THE LEG
Page 10
Page 10 of 15
939549943 Rev G
13. Thread straps through
slots of each CPU mount plate, as shown.
14. Route straps upward, as
shown, (14a) and secure straps into clips (14b).
13
14a
14b
CPU MOUNT
PLATE
60" LONG STRAP
CLIP
STRAP
Page 11
Page 11 of 15
939549943 Rev G
15. An additional CPU may be
installed next, as shown.
16. For each foot, a foot cover
needs to be installed. Install the RH foot cover so it encompasses the leg column as shown (16a). Install the LH foot cover next to the RH foot cover by sliding downward and engaging the RH foot cover (16b) until it is fully secured into place (16c).
16a
16b
16c
15
15
LEG
COLUMN
RH FOOT
COVER
LH FOOT
COVER
RH FOOT
COVER
Page 12
Page 12 of 15
939549943 Rev G
17. Remove side panel cover so plugs and cords can be
routed through. Once cords have been routed, slide cords into 1/4" gap that exists between notch in worksurface and leg. Replace side panel cover when completed. The monitor arms (if applicable) and the worksurfaces may be installed at this point. There are separate assembly directions for these applications.
17
SIDE PANEL COVER
SUPPLIED STAINLESS STEEL SCREW
SLATWALL
SIDE PANEL COVER
CORDS
Page 13
Page 13 of 15
939549943 Rev G
18. Lower the bottom tile brackets onto
the lower support bar.
19. Connect longest strap.
18
19
LOWER SUPPORT BAR
COUPLER
Page 14
Page 14 of 15
939549943 Rev G
20. Connect short strap. 21a. Snap tile into place by pushing it
very firmly at the upper corners of the tiles until both retention clips fully engage.
20
21a
8-9/16"
COUPLER
TILE
21b. Slightly raise the tile if necessary to
line up the retention clips.
21b
21b
Page 15
Page 15 of 15
939549943 Rev G
22a. Slightly pull the tile outward to make sure retention clips are
fully engaged. If the tile is still loose, repeat steps 21a and 21b. See caution label 22a.
22b. If needed, screws on retention clips behind the upper
corners of the tile could be turned to adjust the tension.
22a
SCREWS
22b
Follow all manufacturers’ instructions for installation and use. Obtain assembly directions from your Steelcase dealer or call 1-888-783-3522.
939500525
CAUTION
ALWAYS CONNECT BOTH SAFETY STRAP BUCKLES WHEN CLOSING TILE to prevent it from falling and causing injury.
Also, push very firmly to fully engage both retention clips at upper corners of the tile and verify the connection. If tile is still loose, it is not fully engaged.
X
RETENSION CLIPS
Loading...