STEAM BATH GENERATOR USER GUIDE
BLACK SERIES
6KW
7.5KW 9KW
10.5KW 12KW
V2.1
TABLE OF CONTENTS
PROLOGUE ....................................................................................................................... 4
USER INSTRUCTIONS ......................................................................................................... 4
CHOOSING THE RIGHT LOCATION .......................................................................................... 4
INSTALLATION DRAWING OF STEAM GENERATOR ..................................................................... 5
PLUMBING INSTALLATION ................................................................................................... 8
STEAM GENERATOR SPECIFICATIONS ................................................................................... 10
ELECTRICAL REQUIREMENTS ............................................................................................. 11
ASSEMBLY GRAPH FOR POWER WIRE .................................................................................. 12
INSTALLATION OF THE TOP LIGHT ........................................................................................ 14
STEAM GENERATOR DISSECTION DIAGRAM ........................................................................... 15
CARE & USE FOR THE CONTROL PANEL ................................................................................ 16
CONTROLLER BOX CONTENT .............................................................................................. 16
CONTROL PANEL INSTALLATION INSTRUCTIONS ..................................................................... 17
TESTING THE MACHINE ..................................................................................................... 18
CONTROL PANEL DIAGRAM ................................................................................................ 18
CONTROL PANEL OPERATION ............................................................................................. 19
STEAM GENERATOR MAINTENANCE ..................................................................................... 25
TECHNICAL PARAMETERS .................................................................................................. 29
WIRING DIAGRAMS .......................................................................................................... 30
IMPORTANT!
PRIOR TO INSTALLATION, LET WATER RUN THROUGH THE WATER PIPE TO CLEAN ANY POSSIBLE
DEBRIS BEFORE CONNECTING THE GENERATOR.
INSTALLATION & USER GUIDE
SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.com
Page 3
PROLOGUE
Thank You for choosing SteamSpa for health, beauty and relaxation. Now you can enjoy your own private sanctuary in the comfort of your own home. Let your stress melt away as you relax in your state of the art Steam Room.
For Centuries people have recognized the health benefits of saunas. Leave your stress behind and enter a world of total relaxation, ridding you of pain, toxins, and sore muscles as well as increasing your blood circulation etc., leaving your skin glowing. Besides these physical effects, a SteamSpa Session will leave you totally relaxed by providing you a peaceful and relaxing environment away from all.
Our advanced technology, engineering, and product development provides Steam Generators that enhance the lifestyles of people throughout the world. SteamSpa is continuously refining, updating and developing their products assuring the optimum quality and performance of their products. Working with the industries top engineers we have developed the most efficient, dependable and highest quality products.
USER INSTRUCTIONS
1. Check for visible damages upon delivery of Generator. Any damages to packaging should be reported immediately to shipping company delivery representative and SteamSpa’s Customer Service Dept.
2. Check model and accessories are correct, including voltage input. Any discrepancies are to be reported to SteamSpa’s Customer Service Dept. within 48 hours of delivery.
3. Read installation instructions in detail for a secure and effective installation of SteamSpa generators.
4. SteamSpa recommends the use of a licensed plumber and electrician for proper installation of SteamSpa generators.
5. SteamSpa shall not be responsible for product damage or malfunction caused by self-installation or installation procedures which do not comply with user manual.
6. SteamSpa generators should be installed indoors only.
CHOOSING THE RIGHT LOCATION
1. The generator should be less than 25ft from the steam room for best performance.
2. The steam generator should not be installed in the steam room
3. Do not install outdoor or in any places that will influence the performance of the machine by the environment.
4. Do not install in a frigid location or any places where the water will freeze.
5. Do not install near flammable chemicals.
6. Install in a dry place where the ventilation is good.
7. Install an exhaust fan outside of the steam room for the excess steam to be expelled from the shower room.
8. The steam generator has a hanging groove for wall installations..
9. Both sides and the top of the steam generator need to reserve at least 12 inches space.
10. The area where the machine is installed must be easily cleaned up and convenient for the disassembly of the machine.
11. The installation area must be convenient for the steam generator draining system.
12. The steam tube, safety valve, drain valve, water tube and steam outlet remain very heated after the steam generator has stopped working for some time.
13. The controller panel should be installed away from the steam head to avoid false readings,please read the instructions for the controller’s installation and operation.
Page 4
INSTALLATION & USER GUIDE
SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.com
INSTALLATION DRAWING OF STEAM GENERATOR
ATTENTION! The drawing is only for explanation purposes. As for practical design of steam room, please consult with a qualified
designer, architect or builder.
Page 5
INSTALLATION & USER GUIDE
SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.com
ATTENTION! The drawing is only for explanation purposes, please consult with a qualified designer, architect or builder.
IMPORTANT! All pipe connections should have unions and adapters for easy disconnect.
INSTALLATION & USER GUIDE
Page 6
SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.com
110
ATTENTION! The illustration is just an example; the practical installation must comply with the nation’s electrical criteria, and be
done by a professional electrician.
The steam generator maybe installed in these location.
1. In closet located behind the shower.
2. In Attic
3. In basement etc.
INSTALLATION & USER GUIDE
ATTENTION! If the installation of the steam generator will be more then 10 to 15 feet away from the steam room. It is
recommended to increase the size of the generator 1 or 2 kilowatts higher to increase the steam flow.
SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.com
Page 7
PLUMBING INSTALLATION
WARNING! The installation of all water supply lines should be in accordance to all national and local codes by a licensed plumber.
1. Use unions when connecting pipes.
2. Use brass pipes or copper pipe only.
3. Do not use black and galvanized or PVC pipes.
WATER SUPPLY PIPE (1/2’’)
1. Connect hot water or cold water pipes. However it should not exceed 160F.
2. Install a shut off valve in the water supply line.The shut off valve should be installed in a place where it is easily accessible in case of an emergency.
3. Flush the water supply line completely before connecting the water pipe to the steam generator, to remove any sediments in the water.
4. Use a 3/8” steel braded flex hose with a shut off valve to connect the main waterline to the generator. See page 5 illustration
1.2.
5. The shut off valve should be open approximately 25% to reduce water pressure to the generator. The water pressure to the generator should be between 15 to 20 PSIG if necessary, decrease the pressure accordingly.
6. It is highly recommended to install a pressure reducing valve to reduce the water pressure between 15 to 20 PSI.
STEAM PIPE (3/4’’)
1. Do not install any stop valves in the steam pipes. The steam can never be obstructed.
2. Install a ¾” copper pipe between the steam generator and the steam nozzle for all generators, except the 4.5KW which requires a ½” copper pipe.
3. If needed, the heat insulation material used to insulate the steam pipe should be resistant to temperatures as high as 240F or higher.
4. The shorter the distance, the better. Use curved elbows when connecting pipes to allow the steam to flow smoothly through the steam pipe.
STEAM HEAD (3/4’’)
ATTENTION! Steam Head and the steam outlet gets very hot, try to avoid installing the steam head in a position which will easily
come into contact with the person bathing.
1. Install the steam head approximately 12 inches above the ground floor. If the steam room material is acrylic or non-heat­resistant sheet, please consult with material manufacturer about steam room applications.
2. The steam head outlet should be installed face down. To prevent scalding bather with steam or water.
ATTENTION! Tighten steam head by hand. Do not use a spanner or other tools, use a little soap water and soft sponge to wipe,
and do not use erosive chemical solutions or crude cleaning tools.
IMPORTANT!
1. Please consult manufacturer of materials like acrylic, fiber glass or other anti-heat sheet about the installation of the steam head.
2. In the entire steam room, it is required that steam does not leak out. The pipes, its accessories and the holes should be air proof by applying sealant so that no steam will enter the holes in the wall.
INSTALLATION & USER GUIDE
SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.com
Page 8
DRAINPIPE (1/2’’)
ACCORDING TO THE NATIONAL AND LOCAL PLUMBING CODES: The steam generator drain valve should be equipped with
a drainpipe. The steam generator drains the water by gravity.Check local code requirements for drain valves. Do not connect the safety valve or steam line to drain line.
SAFETY VALVE (3/4’’)
1. Safety valve is an automatic system that is actuated by pressure in order to prevent steam pressure increasing in the interior of the generator .
2. The pressure limit range of the safety valve is 15 PSIG and the pressure will begin to decrease if pressure should come over this value.
3. If it is allowed by local codes, provide the safety valve with exterior drainpipe.
4. Do not dismantle the pressure relief valve while generator is in operation..
5. To maintain the proper automatic operation of the safety valve, make sure the safety valve connection pipe is smooth.
Page 9
INSTALLATION & USER GUIDE
SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.com
STEAM GENERATOR SPECIFICATIONS
20 6m m
18 8m m
15 1m m
Power wi re hol e
142mm
43mm
32mm
62mm
72mm
Fuse for wire power supply
C on tr oll e r w ir e and l ight wire hole
Fuse for wire power supply
St eam outlet
Sa fet y valve
Wate r i nlet
Wate r drainage
395mm 304mm
302mm
266 mm
4.5kW
37 0mm
26 0m m
Pow er w ire hole
Steam outlet
18 0mm
30mm
30 mm
10 0m m
16 0m m
Fus e for wire powe r suppl y
Fuse for wire power supply
S a f e ty valve
Wat er inl et
Wat er drai nage
C on tro lle r wire an d lig ht wi re hole
6kW/7.5kW/9kW
INSTALLATION & USER GUIDE
40 0m m
SteamSpa PHONE: 800-856-0172 FAX: 866-560-1060 http://steamspa.com info@steamspa.com
Page 10