Steamist TSG-12, TSG-15 Installation Instructions Manual

Electrical Installation Instructions
®
®
C
US
Steambath Generators
The Steamist “TSG” Generator operates with only “TSC” series controls mounted inside and an optional TSX or TSR remote control located outside the steamroom. It’s small enough in size to be tucked away using very little space in a vanity, closet, or basement, but large enough to provide steam for most residential baths.
The Steamist “TSG” Steambath Generator comes factory assembled, carefully wired and tested.
NOTE: A “TSC” series control is required to operate the "TSG"
generator.
1. Pre-Installation
a) Proper electrical supply (208 or 240 Volt): See rating
label on Steam Generator and Chart on page 4. Determine proper size of wire, voltage, amperage, and phase for the Steam Generator. 90°C copper wire is required for generator connection.
b) In-line fuse/circuit breaker required: Fuse/circuit breaker
to be installed must be sized in accordance with chart on back page. Do NOT install a GFI (Ground Fault Interrupter) to this equipment (per article 210-8 in the National Electric Code).
c) Route power supply cable to the location where the
Steam Generator will be installed (before walls are closed).
2. Electrical Rough-in
a) Route appropriate power cable to the location the Steam
Generator will be installed. If receptacle is desired, mount the box for the receptacle near the location of the Steam Generator.
NOTE: The plug and receptacle require a rating of no
less than 250V and proper amperage. Refer to chart on page 4 for amperage rating.
After the walls are complete, the Steam Generator and
Control can be wired.
3. Steam Generator Electrical Installation
WARNING: All power to the Steam Generator must be
turned off.
a) Remove the four screws holding the electrical access
cover and remove cover.
b) Locate the supply line knockout. Mount proper strain
relief into knockout hole.
Model: TSG-12 & TSG-15
c) Strip back power cable’s outer insulation jacket
eight inches and insert into Steam Generator. Strip back insulation ½" from the three (3) incoming wires (two power and one ground).
d) Insert ground wire into grounding lug located
on the right side of the electrical compartment and secure.
CAUTION: Be sure the ground wire does not
come in contact with a live electrical part.
e) Locate the terminal/fuse block in the upper portion
of the electrical compartment. Insert power wires into the power lugs on the front of the terminal/fuse block and secure.
4. Optional Auto Drain Valve Connection
a) Open knockout for Auto Drain Valve conduit
connection.
b) Route flexible conduit from valve to knockout and
secure.
c) Connect two wires from valve to the auto drain
connection J8 on the printed circuit board (see Figure 2).
Figure 1 - Steam Generator
Knockouts for
Electrical
Panel Cover
Install Upright
and Level
Control Cable
Knockouts for
Electrical
Supply Line
Water Inlet
" Compression
¾" Safety
Relief Valve
¾" Steam
Optional Auto
Drain Installed
Model TSG-AD
Outlet
WARNING: Elderly persons, pregnant women, or those suffering from heart disease, high blood pressure, diabetes, or
who are otherwise not in good health, do not use this device unless directed to do so by a physician. Also, do not use steambath while under the influence of alcohol. For additional Important Safety Information, please see a separate
!
instruction sheet Pub. No. 199.
IMPORTANT: The warranty of this product is voided if it is used in a commercial application or for anything other than a residential
steambath installation. All electrical connections must be performed by a licensed electrician in accordance with Local and National Electric Codes. This product is not intended for use with Home Automation systems.
05/11
- 1 -
Pub. No. 200-G
Electrical Installation Instructions
Model: TSG-12 & TSG-15
5. Ganging Mulltiple Steam Generators
IMPORTANT: When ganging 2 to 4 steam generators
together an additional 3199 steam head and 5158 control cable must be purchased for each additional generator.
a) Locate the Control Cable knockout at top of steam
generator. Mount proper strain relief into knockout hole.
Checklist
Before starting, insure that the conditions of the following checklist have been met:
The proper size Steam Generator has been selected by using the sizing page in the “Full Line Brochure,” “Pricing Guide,” or “The Generator Sizing Guide” in the Residen­tial Systems/Steambath Product Information section of the Steamist website - www.steamist.com.
CAUTION: An improperly sized Steam Generator will
NOT produce the amount of steam necessary to reach selected temperature.
The proper voltage Steam Generator has been selected (i.e., 208V or 240V). A 208V Generator operating on 240V will damage the heating element, and a 240V Generator operating on 208V will result in a 25% loss of power.
b) Route 5158 control cable from any one of the 4 Modular
Jacks located on the circuit board to the steam genera­tor to be ganged (see Figure 3).
c) Set DIP Switches on each additional Steam Generator's
main PCB as shown in the Gangable Generators chart (see Figure 3).
The Steam Generator is installed in an upright position.
The proper sized 90°C copper wire and circuit breaker have been used.
The circuit breaker is NOT a GFI (Ground Fault Interrupter) type.
The Steam Generator is properly grounded.
The circuit breaker or disconnect switch is on.
Water supply is open to the Steam Generator.
Figure 2 - Internal Electrical Connections
Knockouts for
Control Cables
DIP Switches for Ganging Generators
Water Level Probe
Optional Auto Drain Connection
208/240 Volt incoming power connections
Modular Jacks
Knockouts for electrical supply line
Power Supply
Ground
PC Board
Knockouts for
Control Cables
Water Inlet " Compression Fitting
Safety Relief Valve
¾" Steam Outlet
Optional Auto Drain shown installed
05/11
- 2 -
Pub. No. 200-G