
Installation Instructions
®
®
C
US
Steambath Control
Important: Locate Publication No. 199 “Steam Bath Important Safety Instructions”. This publication includes a Warning
label that the contractor must install on the wall near the entrance to the steam room in a highly visible location. This
label and its additional safety information are packaged with the generator in the envelope containing the installation
!
instructions. If it is lost or missing contact Steamist (201-933-0700) for a replacement Publication No. 199. This publication along with all documents must be left with the owner.
Control Features
1. Timer control
2. Temperature control
3. Multiple user settings
4. AudioSense™ control
5. ChromaSense™ control
6. AromaSense™ control
7. ShowerSense™ control
8. Other Miscellaneous settings
NOTE: For more details see separate operating instructions.
IMPORTANT: Control MUST be installed inside the steam room
for proper operation of the system.
Installation Instructions
1. Pre-Installation - Control Location
The TSC-450 Control must be installed inside the steam
room. For convenience the recommended height from the
floor is four feet. If a TSSH is also installed we recommend a height of 4½" feet when used for both steam and
shower. Provide a 1½" hole in the wall at this location (see
Figure 1).
IMPORTANT: Multi-conductor cable must be installed so
that the end will not be buried inside the wall. The unit will
Figure 1
IMPORTANT: Run the
Control Cable through
a ¾” conduit.
Required Inside
Installation
TSC-450 Control.
Locate away from the
direct line of shower
spray and do NOT
locate above
steamhead.
To Steam Generator
Coupler
Model: TSC-450
Total Sense Touch Control
IM
9:31
1
1
Cleaning Instructions: Use a damp cloth and mild soap.
Do NOT use abrasive cleaners which might scratch the
surface or the base of the control.
not operate unless the control is installed.
STEAMSHOWERSTEAM
2. Electrical Rough-in
Remove the multi-conductor cable from the control
packing box. Carefully route the multi-conductor control
cable from the steam generator to the TSC-450 located
inside the steamroom (see Figure 1). Route multiconductor cable through a ¾" conduit to protect the cable
from damage and to facilitate replacement if necessary.
Figure 2 - Cable Installation on Generator
¾" Conduit
To Control
2
2
SHOWER
1½“ Hole
located four feet
from the floor
Double-Sided
Adhesive Pad
IMPORTANT: The TSC-450 Control will only function with the current TSG steam generators.
12/15
- 1 -
Modular Jacks:
All four modular jacks are
identical and work in
any combination.
Connect to any jack.
Pub. No. 290-D

Installation Instructions
Installation Instructions Model: TSC-450
3.
Control and Cable Installation
a) Locate the previously installed cable and black plastic
strain relief clamp which is in the control packing box.
Locate the knockout on the steam generator for the
control cable (see Figure 2).
b) Place strain relief around cable about seven inches
from the end and insert into the hole. Remove the
protective covering labeled “Remove Before Installation” from the modular jack found on the PC board.
c) Remove the protective cap from the multi-conductor
cable plug. Connect the cable to the modular jack.
d) Close and secure generator cover.
e) Locate Telco Jack at female coupler, on back of the
TSC-450 control. Remove the protective covering
labeled “Remove Before Installation”. Remove protec-
tive cap from cable and plug into jack. Check that the
orientation of the plug properly aligns with the jack. A
snap will indicate the plug is installed correctly (see
Figure 3).
WARNING: Test the control for operation before
continuing on to the next step.
Figure 3
Adhesive Liner
Figure 4
.
A
.S
.
0
U
2
5
.
N
1
I
Z
3
O
.
E
.
o
L
D
N
F
A
R
2
m
/
A
M
e
1
t
E
I
t
L
e
N
C
NOCILISE
Silicone
Channel
Coupler
Control Cable
to Generator
f) Peel adhesive liner from back of the control. Apply
silicone (supplied) into channel around the back of the
control to form a watertight seal (see Figure 3).
g) Apply the control to the wall. Press firmly and hold for a
few seconds. Wipe the excess silicone from around the
control.
The TSC-450 Touch Control has a built in temperature sensor
and therefore must be installed inside the steam room.
Temperature settings: 60ºF min to 125ºF max
Max Time setting: 60 Minutes
Figure 5 - Installation Suggestions
TSX-220 Auxilary
Outside Control
STOP
1
2
Steamhead Installation
Steamhead should be mounted
12" to 18" above the finished floor
or 6" above the rim of the tub as
far from the bather as possible
IMPORTANT: The adhesive on the back of the TSC-450
control will NOT seal this control. It is the responsibility of
the installer to seal this control to the wall with the supplied
silicone. Water damage to the control is not covered by the
warranty.
TSC-450 inside control
required. Locate away from the
direct line of shower spray and
do NOT locate above steam-
IM
9:31
2
112
SHOWER
STEAMSHOWERSTEAM
head.
East Coast Office: 25 E. Union Ave., East Rutherford, NJ 07073 • Tel: 800-577-6478 • Fax: 201-933-0746
®
West Coast Office: Tel: 800-355-6478 • Fax: 661-940-1617
12/15
All Instructions must be given to the homeowner for future use.
- 2 -
Pub. No. 290-D