Steamist TC-110 Installation And Operating Instructions Manual

Steambath Control
Model: TC-110
®
Installation and Operating Instructions
LISTED 995C
WARNING: Elderly persons, pregnant women, or those suffering from heart disease, high blood pressure, diabetes, or who are otherwise not in good health, do not use this device unless
!
directed to do so by a physician. Also, do not use steambath while under the influence of alcohol.
IMPORTANT: The TC-110 Control will only function with one of the following Steamist Generator models: SM-46, SM-79, SM-4, SM-5, SM-7, SM-8, SM-11, SM-12, and SM-15. (It will not work with Models: System-18, System-24, & System-30 unless used in cunjuction with a Steamist thermostatic controller, such as Model# TC-135 or DSC-425).
Control Features
NOTE: This control may be installed inside or outside the
steam room for operation of the system.
Start/Stop Key Pad: Press key pad and generator will
1. begin producing steam in minutes. The generator will remain on for 30 minutes when used with the model SM-46, SM-79 SM-4, SM-5, SM-7, or SM-8 steam generators and 60 minutes for larger generators.
1
START
STOP
2
Pressing the key pad a second time will stop the Steam Generator.
Start/Stop Light: Indicates the Steam Generator is
2. activated.
US
TC-110
Timer and Start/Stop Switch
Installation Instructions
1. Pre-Installation - Control Location
a)
The TC-110 control may be installed inside or outside the steam room. For convenience the recommended height from the floor is four feet. Provide a 1” hole in the wall at this location (see Figure 1).
IMPORTANT: Multi-conductor cable must be installed so that the end will not be buried inside the wall. The unit will not operate unless the control is installed.
2. Electrical Rough-in
a)
Remove the multi-conductor cable from the control packing box. Carefully route the multi-conductor control cable from the Steambath Generator to the TC-110 located either inside or outside the steamroom (see Figure 2). Route multi-conductor cable though a ¾” conduit to protect the cable from damage and to facilitate replacement if necessary.
Cleaning Instructions: Use a damp cloth and mild soap. Do NOT use abrasive cleaners which might scratch the surface or the base of the control.
IMPORTANT: Run the Control Cable through a ¾” conduit.
1“ Hole
located four feet
from the floor
Double-sided
Adhesive Pad
Figure 1
TC-110 Timer and
Start/Stop Switch
07/07
- 1 -
Pub. No. 526-D
3. Control and Cable Installation
a)
Locate the previously installed cable and black plastic strain relief clamp which is in the control packing box. Locate the knock-out on the steam generator for the control cable (see Figure 2).
b)
Place strain relief around cable about seven inches from the end and insert into the hole. Remove the protective covering labeled, “Remove before installation,” from the modular jack found on the PC
c)
board. If a second control will be installed, plug the splitter into the modular jack, this will allow two cables to be plugged into the PC board.
. A
.
0
S
.
.
2
Z
5
U
O
1
.
3
N
L
R
.
I
F
o
A
E
N
2
E
/
D
1
L
m
t
A
e
C
t
e
I
M
N
S
I
L
I
C
O
N
E
IMPORTANT: The Steamist supplied splitter must be used. Locally purchased telephone splitters will NOT work and void the warranty.
d)
Remove the protective cap from the multi-conductor cable plug. Connect the cable to the modular jack located on the printed circuit board
e)
of the Steam Generator.
f)
Close and secure generator cover. Plug cable into receptacle on the back of the TC-110 control. The receptacle is keyed for proper installation.
WARNING: Test the control for operation before continuing on to the next step.
¾“ Conduit
Multi-conductor
Control Cable
To Control
(25 feet)
Figure 3
g)
Peel adhesive liner from back of the control. Apply the control to the wall. Press firmly and hold for a few seconds.
h)
After the control is in place, apply silicone (supplied) around the control to form a water tight seal (see Figure 3).
IMPORTANT: If the TC-110 is mounted on the inside of the shower, the adhesive backing on the control will NOT seal it to the wall. It is the responsibility of the installer to seal this control to the wall using the silicone sealant provided. Warranty is voided if the control is not completely sealed to the wall.
Optional Splitter
for two controls
Modular Jack
Figure 2
Cable Installation
on Steam Generator
07/07
Printed
Circuit Board
Knock-outs for
Strain Relief
Clamps
Protective Covering
“Remove Before
Installation”
Pub. No. 526-D- 2 -