Electrical Installation Instructions
®
®
C
Auto Drain Ready Steambath Generators Models: SM-5, SM-7 and SM-9
US
The Steamist “SM” Generator operates with one or two controls
appropriately located inside and/or outside the steamroom. It’s
small enough in size to be tucked away using very little space in
a vanity, closet, basement, or an insulated attic, but large enough
to provide steam for most residential baths.
The Steamist “SM” Steambath Generator comes factory
assembled, carefully wired and tested.
NOTE: The SMC-120, SMC-150, TC-125, TC-150, TC-110,
TC-135, DSC-425, and DSP Controls are designed to work with
all Steamist “SM” Generators.
1. Pre-Installation
a) Proper electrical supply (208 or 240 Volt): See rating label
on Steam Generator and Chart on back page. Determine
proper size of wire, voltage, amperage, and phase for the
Steam Generator. Only UL rated 90°C wire can be used.
b) Dedicated overcurrent protection device, such as an
in-line fuse/circuit breaker required: Fuse/circuit breaker
to be installed must be sized in accordance with chart
on back page. Do NOT install a GFI (Ground Fault
Interrupter) to this equipment (per article 210-8 in the
National Electric Code).
c) Route power supply cable to the location where the
Steam Generator will be installed (before walls are
closed).
2. Electrical Rough-in
a) At this time read through the installation instructions for
the selected control(s).
b) Route appropriate power cable to the location the
Steam Generator will be installed. If receptacle is
desired, mount the box for the receptacle near the
location of the Steam Generator (see Figure 3: Typical
Installation).
NOTE: The plug and receptacle require a rating of no
less than 250V and proper amperage. Refer to chart on
page 4 for amperage rating.
After the walls are complete, the Steam Generator and
Control can be wired.
3. Steam Generator Electrical Installation
WARNING: All power to the Steam Generator must be
turned off.
a) Remove the two screws holding the electrical
access cover and remove cover.
b) Locate the supply line knockout. Mount proper
strain relief into knockout hole (see Figure 2:
Internal Electrical Connections).
c) Strip back power cable’s outer insulation jacket
eight inches and insert into Steam Generator.
Strip back insulation ½" from the three (3)
incoming wires (two power and one ground).
d) Connect incoming ground wire to floating green
pigtail labeled “GND.”
CAUTION: Be sure the ground wire does not
come in contact with a live electrical part.
e) Connect incoming power to floating black pigtail
leads labeled “L1” and “L2” (see Figure 2: Internal
Electrical Connections).
f) The Steam Generator is ready for operation once
the installation of the controls is completed (refer to
separate Installation and Operating Instructions).
Figure 1 - Steam Generator
Knockouts for
Control Cables
Electric Panel
Cover
Securing
Screws
¾" Safety
Relief Valve
Identification
Plate
Install Upright
and Level
Knockouts for
Electrical Supply Line
Knockouts for
Control Cables
Water Inlet ⅜"
Compression
Fitting
¾" Steam
Outlet
Auto Drain Ready
½" Capped line
WARNING: Elderly persons, pregnant women, or those suffering from heart disease, high blood pressure, diabetes, or
who are otherwise not in good health, do not use this device unless directed to do so by a physician. Also, do not use
steambath while under the influence of alcohol. For additional Important Safety Information, please see a separate
!
instruction Pub. No. 199.
IMPORTANT: The warranty of this product is voided if it is used in a commercial application or for anything other than a residential
steambath installation. All electrical connections must be performed by a licensed electrician in accordance with Local and National
Electric Codes. This product is not intended for use with Home Automation systems.
06/10
- 1 -
Pub. No. 280-A

Electrical Installation Instructions
Checklist Models: SM-5, SM-7 and SM-9
Before starting, insure that the conditions of the following checklist have been met:
The proper size Steam Generator has been selected by
using the sizing page in the “Full Line Brochure,” “Pricing
Guide,” or “The Generator Sizing Guide” in the Residential Systems/Steambath Product Information section of
the Steamist web site - www.steamist.com.
CAUTION: An improperly sized Steam Generator will
NOT produce the amount of steam necessary to reach
selected temperature.
The proper voltage Steam Generator has been selected
(i.e., 208V or 240V). A 208V Generator operating on
240V will damage the heating element, and a 240V
Generator operating on 208V will result in a 25%
loss of power.
Figure 2 - Internal Electrical Connections
Optional Steamist
Splitter for Two
Controls
Black Plastic
Strain Relief
Clamp
Multi-Conductor
Control Cable
(25 feet)
The Steam Generator is installed in an upright position.
The proper sized 90°C wire and circuit breaker have
been used.
The circuit breaker is NOT a GFI (Ground Fault
Interrupter) type.
The Steam Generator is properly grounded.
The circuit breaker or disconnect switch is on.
Water supply is open to the Steam Generator.
Protective
Plug
Covering
(Remove)
Modular Jack
Ground
Connection
Terminal Strip
for Auto Drain
Connection
Test Switch
L1 & L2 Power
Connections
Optional Auto
Drain Connection
Electrical
Supply Wire
208/240V
Steam Outlet
Safety Valve
½" Outlet
When not equipped
with Optional Auto
Drain this line should
remain capped
06/10
- 2 -
Pub. No. 280-A

Electrical Installation Instructions
Figure 3 - Typical Installation Models: SM-5, SM-7 and SM-9
The Electrical Instructions must be given to the homeowner for future use.
NOTE: Unit must be wired with 90°C wire
in a suitable raceway, or, if local codes
allow, provide twist lock plug on a 90°C
wire cord from generator to a 250V
2-pole, 3-wire grounding receptacle
(amperage rating as required).
Inside Installation
Control should be mounted four
feet from the floor. Select a
location convenient to the
bather but not in a direct line of
SMC-120 or TC-125
Auxilary Outside
Control
Shower or Body Sprays and not
directly above the Steamhead.
START
STOP
Appropriately
fuse protected
208/240V field
wiring to Steam
Generator.
Control Cable
Route from
Control to Steam
Generator in a
¾" conduit.
WARNING
HOLD THIS FITTING SECURELY WITH A PIPE
WRENCH WHILE MAKING A PLUMBING
CONNECTION TO THE WATER INLET IN ORDER
TO PREVENT INTERNAL DAMAGE TO THE WATER
SOLENOID VALVE.
009-1054
STEAMBATH GENERATOR
MODEL NO.
®
US
C
SERIAL NO.
LISTED 995C
HEATER LOAD
VOLTS PH MAX AMPS kW
CONTROL CIRCUIT
50/60 HZ
VOLTS AMPS
SERVICE BY AUTHORIZED PERSONNEL ONLY
A PRODUCT OF STEAMIST CO., RUTHERFORD, NJ
SMC-150 or TC-150
Control MUST be
installed inside the
steam room.
TEMPERATURE
START
STOP
IMPORTANT: Run the Control Cable through a ¾" conduit. Remove protective cap when making the
final connection to Control.
06/10
- 3 -
Pub. No. 280-A

Electrical Installation Instructions
Wiring Diagram for Models SM-5 through SM-9 Models: SM-5, SM-7 and SM-9
TEMPERATURE
START
STOP
Typical
Steamist
Control
(Low Voltage)
Multi-Conductor
Cable*
WT
GY
Water
Level
Probe
TANK
LLC-1300-3 Circuit Board
P13
P3P5H
P6
XL
P8
P2
P1
DS1
DS2
P7
DS3
DS4
Fuse 0.15 AMP
P9
BK
Auto Drain
Thermostat
Heating
Elements
See
Chart
OR
P16
P15
OR
Test
Switch
P12
P11
GN
GN
P18
P10
BL
BL
P14
P17
NOTES:
*Supplied with Controller.
**Field connections, use 90ºC wire, gauge
no.See Chart copper.
Water
GN
GND
Solenoid
Valve
Field
Connections**
BK
BK
GN
OR
OR
Terminal
Block
BK
BK
Optional
Auto Drain
Valve
L1
L2
GND
Specication Chart
Max. Cu. Ft.
For Area
Up To
90
210
300
East Coast Office: 25 E. Union Ave., East Rutherford, NJ 07073 • Tel: 800-577-6478 • Fax: 201-933-0746
®
West Coast Office: Tel: 800-355-6478 • Fax: 661-940-1617
KW Volt Phase
240
5
208
240
7
208
240
9
208
1
1
1
1
1
1
Amps
21
24
29
34
38
44
No.
Product
No.
5010
5011
7010
7011
9010
9011
Model
SM-5
SM-7
SM-9
* NM-B type cable does not follow the 90ºC wire guideline. The NEC
requires NM-B type cable max current to be de-rated. Always follow
local and national electrical codes.
*Wire Size
90ºC Copper
AWG
10
10
8
8
8
6
Line
Fuse
30
30
40
45
50
60
LED Color Chart
DS1
GRN
TIMER ON
DS2
YEL
HEAT ON
DS3
AMB
WATER FILL ON
DS4
RED
POWER ON
06/10
- 4 -
Pub. No. 280-A