Stavoklima DITRONIC User Manual, Instructions For Mounting

USER MANUAL
USER MANUAL USER MANUAL
USER MANUAL
INSTRUCTIONS FOR MOUNTING
INSTRUCTIONS FOR MOUNTING
INSTRUCTIONS FOR MOUNTINGINSTRUCTIONS FOR MOUNTING
STAVOKLIMA v.o.s 1
DITRONIC-MANUAL
Icon of external contact or remote control
ENTER button (confirmation and
REGULATOR AND SYSTEM DESCRIPTION
Regulator Ditronic and Ditronic plus is processor regulator intended for air curtains control. The regulator is intended only for wall mounting for basic environment without a humidity.
Button ON/OFF
Fan button (listing up) + button (listing right)
Heating button (listing down)
- button (listing left)
Icon of time regime activation
connection
Medium temperature / outlet air
signalisation
Requested / room temperature
signalisation
Icon of automatic regime activation Icon of keyboard lock
entering the setting part)
Technical conditions for the regulator running:
max. environment temperature 35°C / degree of prote ction IP 20
running voltage of the regulator 12V DC running unit voltage 230V(400V) - 50Hz (if not ordered differently)
STAVOKLIMA v.o.s 2
Icon of the door position (door contact)
Setting of fan grade Icon of heating regime activation
Icon of parallel air curtain connection (y)
Heating grade setting
Icon of associated failure
DITRONIC-MANUAL
pic. 4 - regulator placement on the wall
mounting on the wall and
pic. of the regulator
event. securing the screws with the key
STAVOKLIMA v.o.s 4
Attention !!! Before regulator connection (connection under voltage) check the
righteness of all cabels in the unit electronic. Also check the rightness of the
preliminary element according to the project documentation.
DITRONIC-MANUAL
SHORTENED INSTRUCTIONS FOR QUICK CONTROL
ON - OFF
With the button ON-OFF you can switch ON/OFF the unit. The setting of the fan and heating grade will be saved afterwards and unchanged. This button is superior before all other functions incl. the keyboard lock.
FAN
You can choose the fan grade via the buttons "+" and "-" ; selected grade is indicated by the symbol " _ " , after 1 sec it will be saved automatically into the memory.
HEATING
You can choose the heating grade (for water heated version - control by electrothermic valve /if it is used/ ; for electric version control of electric heater) via the buttons "+" and " -" ; selected grade is indicated by the symbol " _ " , after 1 sec it will be saved automatically into the memory. The heating is activated only if it is needed from the achieved temperatures.
REMOTE RADIO CONTROL
This function is active only if it was permited in the user level. It allows to remote control the unit ON/OFF wireless (key-rack). Active contact is indicated via lighting icon, disconnection by this contact - blinking icon. Activation of this function eliminates the control via external contact.
SUPERIOR SYSTEM - BMS
This function is active only if it was permited in the user level (UU). All the hand controls (fan and heating buttons) is blocked. All the setting are controled by superior system BMS. If there was activated in "UU" the button BMS-hand, it is possible to switch off the system BMS for a short time and control the unit in hand mode. The hand mode activation is made by pressing the button " - " for 5 s. Active control BMS is indicated via lighting icon, control in hand mode - blinking icon.
STAVOKLIMA v.o.s 5
DITRONIC-MANUAL
PARALEL UNIT(S)
The system automatically supports the paralel connection of other units to one control. If other unit is connected into the control electronic, the icon "master/ slave" is activated. All paralle "slave" units follows the unit "Master". Protective functions on the units "slave" are active autonomously.
KEYBOARD LOCK
Against undesirable change-over or unit control it is possible to lock the keyboard. Locking and unlock is made by pressing the buttons "+" and "-" for 6 s at the same time. The lock activation is indicated via light up icon. For the safety reason the button "ON/OFF" is not brought to the lock.
HEAT UP REGIME
This function is active only if it was permitted in the user level. It allows casual covering of the losses in the room (immediate heating). By pressing the button " - " for 5 s, + ENTER it will activate the heat up regime for the time setted in the UU. By pressing any button it will change over to standard regime.
TEMPERATURE OF OUTLET AIR
This icon signals the air temperature coming out of the unit. From this sensor is also activated the anti-frost protection of the heat exchanger. The sensor also restricts the minimum outlet temperature.
STAVOKLIMA v.o.s 6