USER MANUAL
USER MANUAL USER MANUAL
USER MANUAL
INSTRUCTIONS FOR MOUNTING
INSTRUCTIONS FOR MOUNTING
INSTRUCTIONS FOR MOUNTINGINSTRUCTIONS FOR MOUNTING
STAVOKLIMA v.o.s 1
DITRONIC-MANUAL
![](/html/1e/1e9e/1e9e987518744d4d70ce783374749953df72d866651e43a7c71a04e120d5c4fa/bg2.png)
Icon of external contact or remote control
ENTER button (confirmation and
REGULATOR AND SYSTEM DESCRIPTION
Regulator Ditronic and Ditronic plus is processor regulator intended for air curtains
control. The regulator is intended only for wall mounting for basic environment
without a humidity.
Button ON/OFF
Fan button (listing up)
+ button (listing right)
Heating button (listing down)
- button (listing left)
Icon of time regime activation
connection
Medium temperature / outlet air
signalisation
Requested / room temperature
signalisation
Icon of automatic regime activation Icon of keyboard lock
entering the setting part)
Technical conditions for the regulator running:
max. environment temperature 35°C / degree of prote ction IP 20
running voltage of the regulator 12V DC
running unit voltage 230V(400V) - 50Hz (if not ordered differently)
STAVOKLIMA v.o.s 2
Icon of the door position (door contact)
Setting of fan grade
Icon of heating regime activation
Icon of parallel air curtain connection (y)
Heating grade setting
Icon of associated failure
DITRONIC-MANUAL
![](/html/1e/1e9e/1e9e987518744d4d70ce783374749953df72d866651e43a7c71a04e120d5c4fa/bg4.png)
pic. 4 - regulator placement on the wall
pic. of the regulator
event. securing the
screws with the key
STAVOKLIMA v.o.s 4
Attention !!! Before regulator connection (connection under voltage) check the
righteness of all cabels in the unit electronic. Also check the rightness of the
preliminary element according to the project documentation.
DITRONIC-MANUAL
![](/html/1e/1e9e/1e9e987518744d4d70ce783374749953df72d866651e43a7c71a04e120d5c4fa/bg5.png)
SHORTENED INSTRUCTIONS FOR QUICK CONTROL
ON - OFF
With the button ON-OFF you can switch ON/OFF the unit. The setting of the fan and
heating grade will be saved afterwards and unchanged. This button is superior
before all other functions incl. the keyboard lock.
FAN
You can choose the fan grade via the buttons "+" and "-" ; selected grade
is indicated by the symbol " _ " , after 1 sec it will be saved automatically
into the memory.
HEATING
You can choose the heating grade (for water heated version - control by
electrothermic valve /if it is used/ ; for electric version control of electric
heater) via the buttons "+" and " -" ; selected grade is indicated by the
symbol " _ " , after 1 sec it will be saved automatically into the memory.
The heating is activated only if it is needed from the achieved
temperatures.
REMOTE RADIO CONTROL
This function is active only if it was permited in the user level. It allows to
remote control the unit ON/OFF wireless (key-rack). Active contact is
indicated via lighting icon, disconnection by this contact - blinking icon.
Activation of this function eliminates the control via external contact.
SUPERIOR SYSTEM - BMS
This function is active only if it was permited in the user level (UU). All the
hand controls (fan and heating buttons) is blocked. All the setting are
controled by superior system BMS. If there was activated in "UU" the
button BMS-hand, it is possible to switch off the system BMS for a short
time and control the unit in hand mode. The hand mode activation is made
by pressing the button " - " for 5 s. Active control BMS is indicated via
lighting icon, control in hand mode - blinking icon.
STAVOKLIMA v.o.s 5
DITRONIC-MANUAL
![](/html/1e/1e9e/1e9e987518744d4d70ce783374749953df72d866651e43a7c71a04e120d5c4fa/bg6.png)
PARALEL UNIT(S)
The system automatically supports the paralel connection of other units to
one control. If other unit is connected into the control electronic, the icon
"master/ slave" is activated. All paralle "slave" units follows the unit
"Master". Protective functions on the units "slave" are active autonomously.
KEYBOARD LOCK
Against undesirable change-over or unit control it is possible to lock the
keyboard. Locking and unlock is made by pressing the buttons "+" and "-"
for 6 s at the same time. The lock activation is indicated via light up icon.
For the safety reason the button "ON/OFF" is not brought to the lock.
HEAT UP REGIME
This function is active only if it was permitted in the user level. It allows
casual covering of the losses in the room (immediate heating). By pressing
the button " - " for 5 s, + ENTER it will activate the heat up regime for the
time setted in the UU. By pressing any button it will change over to
standard regime.
TEMPERATURE OF OUTLET AIR
This icon signals the air temperature coming out of the unit. From this sensor is also
activated the anti-frost protection of the heat exchanger. The sensor also restricts
the minimum outlet temperature.
STAVOKLIMA v.o.s 6
DITRONIC-MANUAL