Step 4 : Mounting the Assembled Adapter
Plate to Screen
Modify the Assembled Adapter Plate
Slide the Adapter Brackets onto Assembled Adapter
Plate rods. Place the assembled Adapter Plate on the
back of the display with one Adapter Bracket aligned
with a set of vertical mounting holes. Then, slide the
other Adapter Bracket in or out until it aligns with the
second set of vertical mounting holes. The Adapter Plate
should be horizontally centered on the back of the at
panel display.
Use four M6x12 screws and four metal washers and tighten
Adapter Brackets to Adapter Plate rods with a Phillips Head
Screw Driver.
NOTE: There are eight positions for exibility. Move
the Adapter Brackets to desired location. Adapter
Brackets can be ipped around (if required).
Attach the Adapter Brackets using four mounting screws
and four square washers (size will depend on thread pattern on at panel being installed). Once aligned, tighten
all screws down with a Phillips Head Screw Driver.
Adapter
Plate
M8 Hex head
screws w/washers
Adapter
Bracket
Metal Washer
(6 x 13 x 1.2)
M6 x 12
Screw
Mounting
Screw
Square
Washer
SM-CS-ART2-L
Strong™ Contractor Series Universal
Articulating Mount With Dual Arms
For Large Displays
Insert two M8 Hex head screws on the top of the Adapter
Plate with the M6 Allen Wrench. DO NOT IMMEDIATELY
TIGHTEN DOWN!
Step 5: Attaching Screen to Wall Arm Assembly
Lift the display and hook the two Hex head screws with
metal washers in grooves on top of the Mounting Head.
Insert two more Hex head screws with washers in bottom two holes of the Mounting Head, securing it to the
Adapter Plate. Then tighten all four screws with the
Allen Wrench.
NOTE: For demonstration purposes, the wall has been
omitted from the illustrations.
NOTE: This procedure will require two persons.
Ensure that the arm is set to its maximum negative
tilt prior to attaching the display.
Step 6: Running Cables
Run as shown and install Wire Management Caps.
NOTE: Make sure cords have enough slack to allow
full movement of the arm.
Back of
Display
Mounting
Head
Tilt Levers
M8 Hex head
screws w/washers
Lifetime Limited Warranty
Strong™ Mounts have a Lifetime Limited Warranty. This warranty
includes parts and labor repairs on all components found to be
defective in material or workmanship under normal conditions of
use. This warranty shall not apply to products which have been
abused, modied or disassembled. Products to be repaired under
this warranty must be returned to Snap AV or a designated service
center with prior notication and an assigned return authorization
number (RA).
For customer assistance call 1.866.838.5052
Lifetime
Wire Management
Caps
INSTRUCTION MANUAL
ASSEMBLY INSTRUCTIONS
WARNINGS:
• Make sure these instructions are read and thoroughly understood before attempting installation. If you are unsure of any part of the installation
process, contact a professional installer for assistance.
• The wall or mounting surface must be capable of supporting the combined weight of the mount and the display; otherwise the structure must be
reinforced. Installer is responsible for verifying the wall/mounting surface and the anchors used can support the total load of the installation.
• Safety gear and proper tools must be used. Failure to do so can result in property damage and/or serious injury.
• A minimum of two people is required for this installation. Do not attempt to install this mount alone under any circumstance. We highly recom-
mend this product be installed by a qualied professional person.
• Follow all instructions and recommendations regarding adequate ventilation and suitable locations for mounting your display. Consult the
owner’s manual for your display for more information.
SPECIFICATIONS:
• Maximum Load: 150 lbs. (68.04 kg)
• Display Size: 42” to 63”
• Maximum Extension: 30-5/8”
• Wire management
• Pan/Swivel Range: 180°
• Tilt Range: -5° /+ 15°
CAUTION: This wall mount is
intended for use only with
the maximum weight of 150 lbs
BOX CONTENTS:
• Wall Arm Assembly (1)
• Adapter Bracket (2)
• Adapter Panel (1)
• Hardware kit (1)
TOOLS REQUIRED:
• Power Drill
• 1/4” & 5/16” Drill Bits
• Level
• 13mm (1/2”) Socket Wrench or Shifter
(S) Allen Key (x1)
INSTALLATION
Step 1: Use template to mark mounting
hole locations for ange bolts
Note: Corners fold up to catch debris, if needed.
Step 2: Pre-drilling
For Mounting on a Stud Wall
Pre-drill holes into studs using a 1/4” drill bit.
WARNING:
Tighten screws so that wall plate is rmly attached,
but do not overtighten. Overtightening can damage
the screws, greatly reducing their holding strength.
Make sure that mounting screws are anchored into
the center of the studs. The use of a stud nder is
highly recommended.
For Mounting on a Concrete Wall
Pre-drill holes into concrete using 5/16” drill bits.
Insert concrete wall anchors and tap in with hammer,
if necessary.
Correct
plaster/
drywall
ange bolts
Incorrect
plaster/
drywall
PACKAGE CONTENTS:
Wire Management
Caps
Wall Arm Assembly (x1)
Adapter Bracket (x2)
Adapter Panel (x1)
(A) M4 x 15mm Philips
Head Screw (x4)
(B) M5 x 15mm Philips
Head Screw (x4)
(C) M6 x 15mm Philips
Head Screw (x4)
(D) M8 x 15mm Philips
Head Screw (x4)
(E) M4 x 35mm Philips
Head Screw (x4)
(F) M5 x 35mm Philips
Head Screw (x4)
(G) M6 x 35mm Philips
Head Screw (x4)
(H) M8 x 35mm Philips
Head Screw (x4)
(I) M4 x 45mm Philips
Head Screw (x4)
(J) M5 x 45mm Philips
Head Screw (x4)
(K) M6 x 45mm Philips
Head Screw (x4)
(L) M8 x 45mm Philips
Head Screw (x4)
(M) Flange Bolt (x6)
(N) M6 x 12mm Philips
Head Screw (x4)
(O) M8 x 15mm Philips
Head Screw (x4)
(P) 36.2 x 36.2 x 2.5mm
Square Washer
(Q) M10 x 70 Concrete
Wall Anchors (x6)
(R) 6 x 13 x 1.2mm
Metal Washer (x4)
(T) Recessed Hole
Spacer (x4)
(U) Spacer (x4)
Template (x1)
Now Includes:
M4 x 20 Philips
Head Screw (x4)
M5 x 20 Philips
Head Screw (x4)
M6 x 20 Philips
Head Screw (x4)
M8 x 20 Philips
Head Screw (x4)
WARNING:
When installing wall arm assembly on cinder block,
verify rst that you have a minimum of 1-3/8” of
concrete thickness to be used for the concrete
anchors. Do not drill into mortar joints! Be sure
to mount in a solid part of the block, generally1”
minimum from the side of the block. Cinder block
must meet ASTM C-90 specications. It is suggested
that a standard electric drill on slow setting is used
to drill the hole instead of a hammer drill to avoid
breaking out the back of the hole when entering a
void or cavity.
Concrete must be 2000 psi density minimum.
Lighter density concrete may not hold concrete anchor.
Make sure that the supporting surface will safely
support the combined load of the equipment and
all attached hardware and components.
Step 3: Mount the Arm Assembly
For Mounting on a Stud Wall or Concrete Wall
Insert ange bolts through the wall plate into the studs
or the wall anchors. When Installing on concrete, 6 bolts
are needed. Insert four through top set of holes; two on
the far holes, and two near the center. Insert the remaining two bolts on the bottom set of holes.
Cutaway View
Drill holes and
insert anchors.
Place wall assembly
arm with plate
over anchors and
ange bolt
secure bolts.
Tighten all
fasteners.
wall plate
concrete
wall plate
CONCRETE WALL
wall anchor
concrete
wall
concrete