Statron 5359.0 User guide

Page 1
power suppl y type 5359.0
read the inst ruct ion book car ef ul before fi rst use of the power supply. With harm s, t he thr ough non-observ anc e this i nstruct i on ac crue, ex t i ngui shing the c lai m under guar antee pl us cubi t l i ability of the manufacturer f rom t he follow the non-observance.
1. Bestimmungsgemäßer Gebrauch this appliance is for the operational in closed rooms . It's at a saf e fixedplace plus a sufficient ventilation to
observe (ventilating louvres non- uncover!). The applianc e serves the provision a AC v oltage or a d.c. voltage switchable of 2 V to 14 V/max.3A.
Page 2
2. Safety notes 2,1 the power supply unit is in safety class system I as well as in accor dance with VDE 0411 and VDE 0805
(EN60950) structured. The supply transformer is structured and with 3,75 kVeff is primarysecondarily checked according to DI N VDE 0551 as safety insulating transformer . It is radio-screened in accordance with VDE 0875T11 curve B. Es is equipped with a VDE checked main with protective grounding and may therefore only to 230-V-AC input vol tage with protective grounding be operated or attached.
2,2 it is to be made certain that protecti ve groundi ng (yell ow/green) is interr upted neither i n the mai n nor in the
devi ce or in the network, si nce with interrupt ed protectiv e grounding mor tal danger exists. It is to be made
certain further that the isolation i s damaged nor destroyed neither. 2,3 power supply units do not belong into child hands! 2,4 i n com m ercial mechani sms is to be c onsidered the rul es for t he prev enti on of acc idents of the f ederati on of
the commercial professional a ssocia t ion for elec trical system and r esources. 2,5 in schools, training f ac ilities, hobby and self-help workshops. i s by hand possibl e for 2,6 when opening cov ers or remov ing f rom secti ons, except i f thi s, can li ve secti ons be opened. Also inter face
can be live. Before an alignment, maintenance, a repair or an exchange of sections the device m ust be
separate from all voltage supplies, if opening of the device is necessary. If thereafter an alignment,
maint enanc e or a repair at the opened device under voltage are inevitable, may take place onl y by means of
a specialist, who is familiar with the associated dangers or the relevant regulations for it. 2,7 condensers in the device can be still loaded, even if the device were separated from all voltage supplies. 2,8 it i s to be guarant eed that onl y prot ecti ons of t he indi cat ed ty pe and the i ndi cated cal l stromstraer ke are used
as back-up. The use of repaired protections or bridging the fuse holder is il legal. The dev ice is overl oad-
proof and short-circuit-protected. When burning the input protection through a serious error is therefore
present, which must be eliminated by a specialist, before the new intact protection can be used by this
specialist. 2,9 switching it your power supply unit never equivalent if it is brought by a cold into a warm space. The
condensation dev eloping t hereby can destroy your dev ic e under unfav orable ci rcumstances. Let the device
unein switched to room temperatur e c ome. carryi ng of metallic or conductive decoration is forbidden to 2,10 with work with power supply uni ts such as chains, bracelets, rings or the like. 2,11 power supply units are not c er tified for application at humans or ani mals. 2,12 during the seri es connection of the out puts one or several power supply unit s is produced lethal v oltages
(>35 VDC). 2,13 louvers of power supply units may not be taken off! The devices are on hard to place with difficulty
inflammabl e documents so that air can occur t he devices unhindered. The cooling of the devices takes place
predominantly v ia convect ion. 2,14 power supply units and the attached consumers may not be operated unsupervised. Measures are to be
taken to the pr otection and the protec tion of the at tached consumers in relation to effects of the power supply
units (e.g. overvoltages, failure of the power supply unit) and the effects and dangers outgoing from the
consumers themselves (e.g. illegally high power input). Note! Sensitive consumers must be protected
additionally by external measures against destruction! 2,15 in the ev ent of an error can deli v er power supply unit s vol tages ov er 50 V DC v ol tage, f rom which dangers
proceed, also then if the indicated output voltages of t he devices lower is situated. 2,16 with work under voltage f or it expressly certified tools may be only used. 2,17 the outputs of the power supply units (ex it hub/cl amps) and to it at tached lines must be pr otected against
direct contact. In addition the used l ines must suff icient i solation or tension strai n possess and the contact
points be contact-voltage-proof (safety sockets). 2,18 shifting metallically bright lines and contacts i s to be avoided. Al l t hese places are by sui tabl e t o take and t o
protect thus against direct contact with difficulty inflammable insulants or other measures off. Also the
electri call y leadi ng sections of the at tached consumer s are to be protect ed by appropriate measures against
direct c ontact.
2,19 if to assume it is that a safe operation i s no l onger possible, then is the device out of operation to set and against unint entional operati on pr otect. It i s to be assum ed that a safe operation is no longer possible, if ­the dev ice or the mains cable vi si ble damages indicat es, - the devi c e any longer does not operate, - after longer storage under unfavorable conditions, - after heav y transport stresses.
Page 3
3. operating
the appliance becomes a associate to the mains plug St 1 at a earthing contactsocket 230 V / 50 Hertz connected.I s responsible for seeing that t he mai ns cable thus mislays will, that a damage the mai ns cabl e pl us uni- pull down of the apparatus prevents will. With that of the mains switch S1 becomes a the appliance switched on and i s t husaway ready f or operat i on. With t hat of the turn-switch c an the out put voltage ac pl us dc vi a the buil t in bri dge recit if ier associat e subsequent electrol yt c apacitor in 2 V stepped di scontinued will. The decay the v ol t age takes pl ace of t he m arked connec tor . T he output v ol t age are addi ti onal a ther m al aut om ati c circuit breaker provided security for.
4. appl ication
the input v oltage 230V / 50 Hertz i s via the internal f use Si1 plus the mains switch to transf ormer put. All output v oltage are galvanic from the net separate. W ith that of the change-over switch can the on the silk­screen printing stated voltages discontinued will. The built in bridge recitifier associate following charging condenser smooths the d.c. voltage. It I am allowed respective only one the exits charged will. With overcharge detaches the thermal cutout from, this can additional removal of the cause again set will. The appliance is universal usable, particularly in indoctrinate plus schools. For reasons of safety is additionally assistant the vent ilation slot uni- colander welded..
5. security advice
Alternating the built in fuse si 1 : attenti on ! It I am allowed only the prescribed fuse (value see sticker) of a specialist changed will !
The cutout c an additional removal of the ov er load from the user auto- again set will.,
Page 4
Type 5359.0
spezification isolating transformer
*output voltage AC 2-14V bridge rectifier * output voltage DC 2-14V *output current 3A
dimensions (B x H x T): 140 x 130 x 210 mm wigth 3,0 kg Input voltage 230V +/-10% 50 Hz
output voltage DC
display Safty class I mains fuse: Fuse in the side and circuit breaker color RAL 7035 Connection i nput AC power line Connection output 4 mm c lamp Insulati on test volt age EN61010; EN61558-2-4 Operating temperature 0 - 50°C
EMV EN61000-6-3; EN61000-6-2
elko DC output
screenprint
Statron Gerätetechnik GmbH
Ehrenfried-Jopp-Straße 59
15517 Fürstenwalde Tel.: (03361) 37 21 01 Fax: (03361) 37 21 03
e-Mail : statron@statron.de