
COMMERCIAL
™
PATRIOT
LIGHT-DUTY
COMMERCIAL ELECTRIC WATER HEATERS
Designed for use as recovery heaters for
light-duty hot water supply service.
™
Patriot
with tank capacities from 6 through 119
gallons. They can be installed for nonsimultaneous and single element operation
(maximum input up to 6 KW), or for
simultaneous dual-element operation
(maximum input up to 12 KW).
Zinc-Plated Copper Sheath
Heating Elements Standard
• Medium watt density design disperses
• Element options from 1.5 KW to 6
Standard Voltages for
Easy Installation
• 120V, 277V single-phase, and 208V,
• Easily converted to single-phase at ter-
• Single-element heater, single-phase only
Factory-Installed
Terminal Block
• Provides electrical service to heater and
Factory-Wired Controls
PCE water heaters are available
element temperature over larger
surface contact area to minimize scale
buildup, maximize efficiency and prolong element life
KW (non-simultaneous or simultaneous operation), recoveries from 6 gph
to 49 gph at 100°F rise
240V and 480V unbalanced 3-phase
delta
minal block (except for 208V with
6000 watt elements
(see chart for dual-element options)
connects to block
• Manual reset high temperature cutoff
per element (dual-element models)
• Factory wired for non-simultaneous
operation; easily converted to simultaneous operation
Glass-Lined Tank with
Anode Rod
• Provides long-lasting protection against
corrosion
Maximum Hydrostatic Working
Pressure: 150 psi
Meets or exceeds the thermal
efficiency and/or standby loss
requirements of the U.S.
Department of Energy and current
edition of ASHRAE/IESNA 90.1
Other Patriot™ PCE
Series Features
• Simplified, color-coded circuitry for
ease of service
• Bonderized undercoat on cabinet with
baked enamel finish
• Top inlet and outlet openings
• Foam insulation
• Drain valve
• UL-approved field conversion program
Three-Year Limited Tank
Warranty
• Consult written warranty shipped with
water heater, or contact State for
complete information
For more information on State® contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free USA
www.statewaterheaters.com
SCESS00106 August 2008R
• Temperature control (adjustable from
110°F to 170°F on single-element;
120°F to 180°F on dual-element models)
Page 1 of 4 ©2007 State Water Heaters Company

WATTAGE, RECOVERY AND ELECTRICAL CHARACTERISTICS
UPPER
AND
RECOVERY – GALLONS
PER HOUR AT °F RISE
FULL LOAD CURRENT IN
AMPERES
LOWER
ELEMENT
WATTAGE
40°F
100°F
140°F
208V
240V
NON-SIMULTANEOUS AND SINGLE-ELEMENT OPERATION–SINGLE-PHASE POWER
1500
2000
2500
3000/3000
4000/4000
4500/4500
5000/5000
6000/6000
15
20
25
30
41
46
51
61
20
24
6
8
10
12
16
18
4
5
7
8
11
13
14
17
7.2
9.6
12.0
14.4
19.2
21.6
24.0
28.8
6.3
8.3
10.4
12.5
16.7
18.8
20.8
25.0
SIMULTANEOUS DUAL-ELEMENT OPERATION–THREE-PHASE POWER
(Both elements on when entire tank is cold)
61
3000/3000
4000/4000
4500/4500
24
81
32
91
36
23
26
17
25.0/14.4*
33.3/19.2*
37.5/21.6*
21.7/12.5*
28.9/16.7*
32.5/18.8*
480V
3.1
4.2
5.2
6.3
8.3
9.4
10.4
12.5
10.8/6.3*
14.4/8.3*
16.2/9.4*
HEATING ELEMENT AVAILABILITY
INPUT
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
120V
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
WATTS
*Not available in PCE 10 10MSA, PCE 17 10MSA and PCE 30 20RTA.
**A6 non-simultaneous circuit only.
PCE 6 10MSA not available above 2500 W.
PCE 6 10MSA not available in 480V.
208V
YES
YES
YES
YES
NO
YES
YES
YES*
NO
YES**
240V
YES
YES
YES
YES
YES
YES
YES
YES*
ES
Y
YES
277V
YES
YES
YES
YES
NO
YES
YES
YES*
NO
YES
480V
NO
NO
YES
YES
NO
YES
YES
YES*
NO
YES
5000/5000
6000/6000
*Terminal L2 Amperage/Terminals L1 and L3 Amperage
101
122
49
41
29
35
TANK CAPACITY, DIMENSIONS AND WEIGHTS
MODEL
NUMBER
PCE 6 10MSA
PCE 10 10MSA
PCE 17 10MSA
PCE 20 10MSA
PCE 30 20LSA
PCE 40 20LSA
PCE 50 20LSA
PCE 30 20RTA
PCE 40 20RTA
PCE 52 20RTA
PCE 66 20RTA
PCE 82 20RTA
PCE 120 20RTA
GALLON
CAPACITY
6
10
15
20
30
40
50
30
40
50
66
80
119
NUMBER
OF
ELEMENTS
1
1
1
1
2
2
2
2
2
2
2
2
2
41.6/24.0*
N/A
DIMENSIONS IN INCHES
A
15-1/2
18-1/4
26
22-1/4
30-7/8
32-1/4
32-1/4
34-1/2
45-1/8
54-7/8
60-3/4
59-3/8
62-7/16
B
14-1/4
18
18
21-3/4
21-3/4
24
26-1/2
20-1/2
20-1/2
20-1/2
21-3/4
24
29-3/8
36.1/20.8*
43.3/25.0*
C
11
12-1/2
20-1/2
15-3/8
24-1/8
25-9/16
25-1/8
N/A
N/A
N/A
N/A
N/A
N/A
18.0/10.4
21.7/12.5
D
N/A
N/A
N/A
N/A
8
8
8
8
8
8
8
8
8
APPROX
SHIPPING
WEIGHT
(LBS.)
35
54
58
73
100
125
166
98
113
131
176
211
326
SCESS00106 August 2008R
Page 2 of 4 ©2008 State Water Heaters Company

TOP VIEW
PCE 6 10MSA, PCE 10 10MSA
PCE 17 10MSA, PCE 20 10MSA
OUTLET
3/4" (FEMALE)
NPT
2 1/2"
JUNCTION
BOX
PCE 30 20LSA, PCE 40 20LSA,
TOP VIEW
PCE 50 20LSA
“B”
OUTLET
3/4"(FEMALE)
NPT*
3/4" NPT
RELIEF VALVE
OPENING
ELECTRICAL
CONNECTION
INLET
3/4" (FEMALE)
NPT
PCE 6 10MSA, PCE 10 10MSA
PCE 17 10MSA, PCE 20 10MSA
INLET
3/4" (FEMALE)
NPT
ALTERNATE OUTLET
3/4" (FEMALE) NPT
B
FRONT VIEW
C
OUTLET
3/4" (FEMALE)
NPT
JUNCTION
BOX
A
TOP VIEW
“D”“D”
“B”
INLET
3/4" (FEMALE)
NPT
3/4" NPT
RELIEF VALVE
OPENING
21/2"
3/4" NPT
RELIEF VALVE
OPENING
BRASS
DRAIN
VALVE
3 3/4"
FRONT VIEW
PCE 30 20LSA, PCE 40 20LSA,
PCE 50 20LSA
SCESS00106 August 2008R
“C”
“A”
DRAIN
“A”
VALVE
3 3/4"
FRONT VIEW
PCE 30 20RTA – PCE 120 20RTA
Page 3 of 4 ©2008 State Water Heaters Company

COMMERCIAL
SUGGESTED SPECIFICATION
The water heater(s) shall be State Patriot™ Model(s) ________, rated at _______ KW, _______ volts, _______ -phase, 60
cycle AC. Water heater(s) shall be listed by Underwriters Laboratories and meet or exceed the thermal efficiency and/or standby
loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1 shall be ________ gallon
capacity with a recovery capacity of ______ GPH at a temperature rise of ______°F with ______/______ upper/lower element
wattage. Heater(s) shall have 150 psi working pressure and be equipped with extruded high-density anode rod. All internal
surfaces of the heater(s) exposed to water shall be glass-lined with an alkaline borosilicate composition that has been fused to
steel by firing at a temperature of 1600°F. Electric heating elements shall be medium watt density with zinc-plated copper sheath
or Incoloy sheath _______________.
Each element shall be controlled by an individually mounted thermostat and high-temperature cutoff switch. The outer jacket
shall be a baked enamel finish and provided with a full-size control compartment for performance of service and maintenance
through a hinged front panel and shall enclose the tank with foam insulation.
Electrical junction box with heavy-duty terminal block shall be provided (except on 120V and 277V [no junction box on
PCE 6 10MSA thru PCE 20 10 MSA]). The drain valve shall be located in the front for ease of servicing. Heater tank shall
have a 3-year limited warranty as outlined in the written warranty. Fully illustrated instruction manual will be included.
For more information on State® contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free USA
www.statewaterheaters.com
SCESS00106 August 2008R
Page 4 of 4 ©2008 State Water Heaters Company