Statewaterheaters GPO69 700 User Manual

TITAN
Commercial Oil Water Heater
Meets or Exceeds the Thermal Efficiency and/or Standby Loss Requirements of the U.S. Department of Energy and Current Edition of ASHRAE/IESNA 90.1
Titan™ Models Inhibit Lime and Sediment Buildup –
Titan™models are warranted against tank failure due to sediment buildup for three years.
Glasslined Tank – Assures years of rust-free clean hot water. 160 psi working pressure. 180° Adjustable Thermostat – Has upper and lower sensing bulbs to average
water temperatures at top and bottom of heater for maximum temperature control (120°-180°).
Safety Shutoff – Limits temperature buildup. UL Listed Oil Burner – Precision engineered to match the units they are used
with; designed to fire 1.75 to 5.0 gallons of oil per hour. All models equipped with single phase continuous duty motor 120 volt AC 60 Hz, 3450 rpm with overload switch and interrupted ignition. Standard burners equipped with single stage pump with 1 or 2 line capability. Flame retention principle assures high rate of combustion efficiency, yet maintains low operating noise levels. Fuel unit includes pump, strainer, pressure regulating valve and ignition transformer. Transformer rated at 120 volt AC, 60 Hz with high voltage secondary, UL listed for use with No. 1 and 2 commercial grade fuel oil. Burner mounted cadmium cell relay for flame detection - 15 second safety switch timing eliminates the need for RA890F Electronic Safeguard. Complies with UL 296-MP 1192.
Efficient Combustion Chamber – Precast, high temperature combustion chamber
made of alumina silica ceramic fiber. Engineered for maximum insulation and heat reflection. Unique design assures more complete combustion by stabilizing flame pattern.
Interrupted Ignition – Reduces electrical consumption. Oil Solenoid Safety Valve – Standard on GPO75 385, GPO75 455 and GPO69 700.
3/4” Drain Valve – Provided in lower tank for fast draining.
Two Hand-Hole Cleanouts – Allows easy cleaning on standard models GPO75 385
and larger and ASME models.
Anodic Protection – For longer tank life. Flame Observation Port – Permits convenient flame check. Foam Insulation – Saves fuel, helps assure constant temperature, vermin proof. Jacket – Heavy gauge steel with baked enamel finish over bonderized undercoat. Not
approved for installation on combustible flooring.
Easy To Install Burner – Three bolt mounting of burner assures easy installation. Barometric Draft Regulator CSA Certified and ASME Rated T&P Relief Valve
CAUTION: Units must be installed on non-combustible surface.
COMMERCIAL
Limited Warranty:
Limited Warranty Outline
– If the tank should leak any time during the first three
years, under the terms of the warranty, State Water Heaters will furnish a replacement heater; installation, labor, handling and local delivery extra.
– NOTE: This Outline Is NOT
complete information, consult the written warranty or State Water Heaters.
For more information on Titan™ contact: State Water Heaters 500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free USA www.statewaterheaters.com
SCOSS00105 January 2013R
A Warranty.
Other Features:
Two layers of high temperature ceramic fiber insulation in combustion chamber Flame inspection port opening Mounted on rugged channel iron skids Multiple anodes for protection
Optional Features:
– Two Stage Pump – For use with underground oil storage tanks. – ASME Construction – Available on models GPO84 315, GPO75 385, GPO75 455,
GPO69 700. ASME units have 160 psi working pressure.
TITAN
Commercial Oil Water Heater
SPECIFICATIONS
Storage
Model Number
*Based on No.2 fuel oil. Capacity ratings are actual heater performance at 80% thermal efficiency. **These models are available with ASME construction. When ordering ASME construction, add “ A ” to
end of model model. Example: GPO 69 700OE A
NOTE: Above 2000´ altitude, input ratings should be reduced 4% for each 1000´ above sea level.
Capacity
Gallons
U.S.
Input*
BTU/Hr.
Firing
Rate
GPH
80°F Rise 100°F Rise 140°F Rise A B C D E
Recovery
74-3/4 74-3/4 74-3/4 74-3/4 74-3/4 79-3/4
Dimensions In Inches
67-3/4 67-3/4 67-3/4
70-3/8
27 27
27
65
25-1/4
66
25-1/4
30-1/16
COMMERCIAL
etamixorppA)snollaG( tuptuO
Water
Connections
1-1/2 1-1/2
1-1/2 1-1/2
1-1/2 1-1/2
ASME
(ON SELECTED MODELS)
HP
Shipping Wt. (lbs.)
568 557 557
638 647 739
668 730
748 853
Motor
6 8 8 8 8
10
23-1/8 23-1/8 23-1/8 23-3/4 23-3/4 29-3/8
1/8 1/8 1/8
1/8 1/8
1/8
1-1/2 1-1/2 1-1/2
1-1/2 1-1/2 1-1/2
37 ˝
1
2 ˝ NPT INLET &
1
OUTLET OPENINGS
1˝ NPT T& P VALVE OPENING
B
ENTRY
A
D
27 3 ⁄ 4 ˝
ELEC.
C
E
GPO SUGGESTED SPECIFICATION
Water heater(s) shall be commercial oil model number______________or equivalent. Heater(s) shall have a minimum oil firing rate of ______________gph at 100°F temperature rise and a storage capacity of _________________gallons. The 160 psi working pressure tank shall be glasslined with the alkaline borosilicate composition being fused to the steel at 1600° and be equipped with 1-1/3” water inlet and outlet openings, and 2-3/4” x 3-3/4” boiler-type hand-hole cleanout (2) on GPO84 315 and larger or ASME models. The tank shall be insulated with 2˝ of vermin proof fiber glass insulation. The outer jacket shall have baked enamel finish over a bonderized undercoating. The burner shall be Underwriters’ Laboratories listed and have a ___________________(one or two) stage oil pump. The burner shall have flame retention, interrupted ignition and be equipped with primary controls which will provide for 15 second safety shutdown in the event of flame failure. The heater(s) shall be factory equipped with primary controls which will provide for 15 second safety shutdown in the event of flame failure. The heater(s) shall be factory equipped with temperature limiting device, drain valve, flame observation port and 180° adjustable thermostat having upper and lower sensing bulbs which average the water temperatures at the top and bottom of the tank for maximum water temperature control. A pressure and temperature relief valve shall be furnished and installed by the factory. Heater tank shall have a 3 year limited warranty against corrosion and tank failure due to sediment buildup as outlined in the warranty. CAUTION: Unit must be installed on non-combustible surface. MULTIPLE INSTALLATIONS Furnish and install __________________models as specified with a State (2, 3, or 4) heater manifold kit, package number _____________.
For more information on Titan™ contact: State Water Heaters 500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free USA www.statewaterheaters.com
SCOSS00105 January 2013R