State Select® gas water heaters feature an FVIR Compliant design, which meets the ANSI Z21.10.1-CSA 4.1 standards for flammable vapor ignition resistance. Select water heaters are available in a variety of heights which can accommodate installations with limited space.
Intelligent Control Logic
• The internal microprocessor provides enhanced operating parameters and tighter differentials for precise sensing and faster heating response to optimize performance.
Self-powered Electronic Gas Valve
• Uses a thermopile to generate the power needed to operate the electronic gas control without requiring an external power source.
Diagnostics
• The electronic gas control incorporates an LED status indicator that monitors system operation & service diagnostics.
• Reduces lime and sediment buildup, maximizes hot water output
• Made from State PEXAN long-term exposure to temperatures up to 400ºF
Green Choice® Gas Burner
• Patented “Eco-Friendly” burner design reduces NOx emissions by up to 33% and complies with 40 ng/j requirements for low NOx emissions.
, a cross-linked polymer that can withstand
Low Lead Content
300/301 Series
For more information on Select® contact: State Water Heaters 500 Tennessee Waltz Parkway, Ashland City, TN 37015
800.365.0024 Toll-free USA www.statewaterheaters.com
SRGSS02408
Revised April 2013
Easy-to-Light Piezo Ignitor
• For fast “one-hand” pilot ignition
Glasslined Tank with Aluminum Anode Rod
• For long-lasting protection against build up and corrosion
Durable, Brass Tamper-Resistant Drain Valve
CSA Certified and ASME Rated T&P Relief Valve Design-Listed by CSA International
• Certified at 300 PSI test pressure and 150 PSI working pressure
• Listed according to ANSI Z21.10.1 - CSA 4.1 standards governing storage-type water heaters
• Meets the Federal Energy Efficiency Standards effective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of 1992 and meets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current editions of ASHRAE/IESNA 90.1.
• Additional code compliance: UBC, CEC, SBCC, CABO, HUD and BOCA National Codes
FVIR Compliant Design
Simplifies Service
• Uses industry standard thermopile
• Burner operation may be viewed through new enlarged sight glass
6-Year Limited Tank and Parts Warranty
Consult written warranty or contact State Water Heaters for complete information
SELECT
RESIDENTIAL
®
300/301 Series
Residential Gas Water Heaters
MODEL
NUMBER
TALL MODELS
GS6 30 YORT
GS6 50 YBRT
SHORT MODELS
GS6 30 YORS GS6 40 YBRS
GS6 50 YBRS
Recoveries are rounded to nearest gallon. For 10-Year Tank and 6-Year Parts Warranty, change "6" to "X" in Model Number (GSX 40 YBRT). Water Connections – 3/4" male on all models. When ordering Propane, change "Y" to "H" in model number (GS6 40 HBRT). External heat trap nipples are factory-installed on all models. † Propane Gas – 40,000 for 50-gallon short, 37,000 for the 50-gallon tall, 36,000 input for 40-gallon models and 32,000 for 30-gallon models.
PEAK
DEMAND
OUTPUT
(1st Hour
Rating
Gallons)
67
88
60 66
93
ENERGY FACTOR
.61
GALLON
CAPACITY
50
BTU INPUT RECOVERY
PER HOUR 90°F RISE
NATURAL† GALLONS
40,000 41
THICK-
(Inches)
41
FOAM
NESS
13635,50030.61
1
14140,00050.58
13635,50030.61 14140,00040.59
2
When or dering top-moun ted T&P Valve, a dd "G" to model number (GS6 40 YBRT G).
Propane (LP) models are Series 201
A B C D E F
61-1/2
61-3/4
60-3/4
50
51-1/2 53-1/4
58
58-1/4
57
46-3/8 47-3/4
49-1/2 24
DIMENSIONS IN INCHES
16
18 13 51-3/4
20
18 20
13
13 8 50-1/4 3 or 4
13-1/2 8
13 8
13-1/4
8
8
52
40 41
42-1/2
Low Lead Content
DRAFT
HOOD
OUTLET
3 or 4
3 or 4 3 or 4
3 or 4
Flammable Vapor Ignition Resistant (FVIR) Water Heaters
State FVIR design meets the American National Standards Institute standards (ANSI Z21.10.1 - CSA 4.1) that deal with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.
Feature a sealed combustion chamber with air intake filter and a flame arrestor built into the water heater base. In addition, a thermal cutoff (TCO) device, is designed to shut off gas flow to the burner and pilot if poor combustion is detected.
ANODE ROD (OPTIONAL T&P LOCATION)
HOT CONNECTION
APPROX
SHIPPING
WEIGHT
(LBS)
112
138
153
113 135
175
If flammable vapors accidentally enter the combustion chamber, the arrestor is designed so flames burn off the top surface and can not escape down through the arrestor.
A. Industry standard thermopile B. Large View Port for easy burner inspection C. 3600 combustion air filter D. Thermal Cutoff (TCO) with manual reset
For complete information on limited warranties, consult written warranty, or contact the State Customer Care Center, 1-800-365-0024.
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
For more information on Select® contact: State Water Heaters 500 Tennessee Waltz Parkway, Ashland City, TN 37015
800.365.0024 Toll-free USA www.statewaterheaters.com
SRGSS02408
Revised April 2013
COLD CONNECTION
E
C
VALV E
A
B
1/2" GAS CONNECTION
D
Maximum Hydrostatic Working Pressure: 150 PSI.