RESIDENTIAL
®
SCOU T
HUD CODE AND COMPACT ELECTRIC
WATER HEATERS
HUD Code Models comply with
HUD Standards for
Manufactured Housing
Installation.
Also complies with National
Appliance Energy Conservation Act
(NAECA) energy-efficiency standards
effective January 20, 2004.
Side-Mounted 3/4" Cold
Water Inlet and Hot Water
Outlet – Easy-to-install when cold
water supply originates below the
structure.
Side-Mounted Electrical
Junction Box – Simplifies
installation.
30, 40 and 50-Gallon Models
Available with One or Two
Heating Elements –
One element only on 20-gallon
•
model
Available 120V inputs: 1650 and
•
2000 watts
Available 240V inputs: 3800,
•
4500 and 5500 watts.
Glass-Lined Tank – Provides
long-lasting protection against rust
and corrosion.
All Scout Electric Water
Heaters are equipped with
factory-installed Temperature
& Pressure (T&P) Relief Valve
and foam insulation to protect
against radiant heat loss.
Compact Electric Water
Heaters feature compact
design, versatile plumbing
and electrical connections -
Designed for installation under a
counter, in a crawl spsace or in other
tight spaces. tank capacities from 6
through 40 gallons. Single heating
element standard.
1-Year Limited Tank and Parts
Warranty
Code Compliance – All models meet or exceed federal minimum energy standards effective January 20, 2004, according to latest
editions of the National Appliance Energy Conservation Act (NAECA). They also comply with the latest editions of the B.O.C.A. National
Codes, C.E.C., U.B.C., S.B.C.C., C.A.B.O. and the H.U.D. standards. All models U.L. Listed according to safety specifications outlined
in Underwriters' Laboratories, Inc. Standards for Safety (U.L. 174).
For more information on the Scout Compact Electric Water Heaters contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800 365-0024 Toll-free USA
www.statewaterheaters.com
SMESS00107 January 2008R © 2007 State Industries
RESIDENTIAL
AB B
ELECTRICAL
OPENING
T & P
VALV E
COLD
INLET
HOT
OUTLET
C
T & P
VALV E
®
SCOU T
HUD CODE AND COMPACT ELECTRIC
WATER HEATERS
MODEL PEAK DEMAND OUTPUT ENERGY GALLON RECOVERY R SHIPPING
NUMBER (1st Hour Rating Gallons) FACTOR CAPACITY
TABLE TOP MODELS
HUD CODE MODELS
STANDARD VOLTAGE/WATTAGE DIMENSIONS IN INCHES APPROXIMATE
VOLTAGE WATTAGE
90°F RISE VALUE A B C WEIGHT
HEIGHT DIAMETER (LBS.)
SCI 30 DHMS 43 .93 30 240 3800 17 16 37-1/2 28-1/4 20-1/2 90
SCI 40 DHMS 51 .93 40 240 3800 17 16 46 38-1/4 20-1/2 115
SCI 52 DHMT 58 .93 50 240 3800 17 16 56 47-3/4 20-1/2 140
MODEL PEAK DEMAND OUTPUT ENERGY GALLON RECOVERY R SHIPPING
NUMBER (1st Hour Rating Gallons) FACTOR CAPACITY STANDARD MAXIMUM 90°F RISE VALUE A B C WEIGHT
JUNIOR MODELS
COMPACT MODELS
ELEMENT WATTAGE DIMENSIONS IN INCHES APPROXIMATE
120V 240V HEIGHT T&P DIAMETER (LBS.)
SCI 6 SOMS N/A N/A 6 1650 3000 8 8 15-1/4 10-3/4 14-1/8 31
SCI 10 SOMS N/A N/A 10 1650 4500 8 8 18-1/4 12-1/4 16 45
SCI 20 SOMS N/A N/A 19 1650 4500 8 8 25 18-1/2 18 65
SCI 20 SOMT N/A N/A 19.9 1650 4500 8 8 31-3/4 25-3/4 16 62
SCI 30 SOMS K 37 .93 29 1650 6000 8 16 30 22-1/2 22 111
SCI 40 SOMNS K 43 .92 38 1650 6000 8 12 31-1/8 24-5/8 23 12
Add suffix “E” for 240 volts (SCI 20 SOMT E)
Recoveries are rounded to nearest gallon
Water Connections – 3/4" on HUD Code and Compact models.
†Top mounted T&P adds approximately 3" additional to overall height
HUD CODE MODELS
A
OO
A
I
O
ES6 6 SOMS
T
O
I
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
Inlet
I
OutletTT&P
O
D
For more information on the Scout Compact Electric Water Heaters contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800 365-0024 Toll-free USA
www.statewaterheaters.com
SMESS00107 January 2008R © 2007 State Industries
C
*
O
Drain
I
*
T
D
B
Plugged Inlet
I*
Plugged Outlet
O*
COMPACT MODELS
*
A
O
T
O
I
ES6 10 SOMS
AO*I*
A
*
O
D
I
D
ES6 20 SOMS
O
I
*
T
T
I
D
ES6 20 SOMT