State Industries SMESS00107 User Manual

RESIDENTIAL
®
SCOU T
HUD CODE AND COMPACT ELECTRIC WATER HEATERS
HUD Code Models comply with HUD Standards for Manufactured Housing Installation.
Also complies with National Appliance Energy Conservation Act (NAECA) energy-efficiency standards effective January 20, 2004.
Side-Mounted 3/4" Cold Water Inlet and Hot Water Outlet – Easy-to-install when cold
water supply originates below the structure.
Side-Mounted Electrical Junction Box – Simplifies
installation.
30, 40 and 50-Gallon Models Available with One or Two Heating Elements –
One element only on 20-gallon
model Available 120V inputs: 1650 and
2000 watts Available 240V inputs: 3800,
4500 and 5500 watts.
Glass-Lined Tank – Provides
long-lasting protection against rust and corrosion.
All Scout Electric Water Heaters are equipped with factory-installed Temperature & Pressure (T&P) Relief Valve and foam insulation to protect against radiant heat loss.
Compact Electric Water Heaters feature compact design, versatile plumbing and electrical connections -
Designed for installation under a counter, in a crawl spsace or in other tight spaces. tank capacities from 6 through 40 gallons. Single heating element standard.
1-Year Limited Tank and Parts Warranty
Code Compliance – All models meet or exceed federal minimum energy standards effective January 20, 2004, according to latest
editions of the National Appliance Energy Conservation Act (NAECA). They also comply with the latest editions of the B.O.C.A. National Codes, C.E.C., U.B.C., S.B.C.C., C.A.B.O. and the H.U.D. standards. All models U.L. Listed according to safety specifications outlined in Underwriters' Laboratories, Inc. Standards for Safety (U.L. 174).
For more information on the Scout Compact Electric Water Heaters contact: State Water Heaters 500 Tennessee Waltz Parkway, Ashland City, TN 37015
800 365-0024 Toll-free USA www.statewaterheaters.com
SMESS00107 January 2008R © 2007 State Industries
RESIDENTIAL
AB B
ELECTRICAL OPENING
T & P VALV E
COLD INLET
HOT OUTLET
C
T & P VALV E
®
SCOU T
HUD CODE AND COMPACT ELECTRIC WATER HEATERS
MODEL PEAK DEMAND OUTPUT ENERGY GALLON RECOVERY R SHIPPING
NUMBER (1st Hour Rating Gallons) FACTOR CAPACITY
TABLE TOP MODELS
HUD CODE MODELS
STANDARD VOLTAGE/WATTAGE DIMENSIONS IN INCHES APPROXIMATE
VOLTAGE WATTAGE
90°F RISE VALUE A B C WEIGHT
HEIGHT DIAMETER (LBS.)
SCI 30 DHMS 43 .93 30 240 3800 17 16 37-1/2 28-1/4 20-1/2 90
SCI 40 DHMS 51 .93 40 240 3800 17 16 46 38-1/4 20-1/2 115
SCI 52 DHMT 58 .93 50 240 3800 17 16 56 47-3/4 20-1/2 140
MODEL PEAK DEMAND OUTPUT ENERGY GALLON RECOVERY R SHIPPING
NUMBER (1st Hour Rating Gallons) FACTOR CAPACITY STANDARD MAXIMUM 90°F RISE VALUE A B C WEIGHT
JUNIOR MODELS
COMPACT MODELS
ELEMENT WATTAGE DIMENSIONS IN INCHES APPROXIMATE
120V 240V HEIGHT T&P DIAMETER (LBS.)
SCI 6 SOMS N/A N/A 6 1650 3000 8 8 15-1/4 10-3/4 14-1/8 31
SCI 10 SOMS N/A N/A 10 1650 4500 8 8 18-1/4 12-1/4 16 45
SCI 20 SOMS N/A N/A 19 1650 4500 8 8 25 18-1/2 18 65
SCI 20 SOMT N/A N/A 19.9 1650 4500 8 8 31-3/4 25-3/4 16 62
SCI 30 SOMS K 37 .93 29 1650 6000 8 16 30 22-1/2 22 111
SCI 40 SOMNS K 43 .92 38 1650 6000 8 12 31-1/8 24-5/8 23 12
Add suffix “E” for 240 volts (SCI 20 SOMT E) Recoveries are rounded to nearest gallon Water Connections – 3/4" on HUD Code and Compact models. †Top mounted T&P adds approximately 3" additional to overall height
HUD CODE MODELS
A
OO
A
I
O
ES6 6 SOMS
T
O
I
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
Inlet
I
OutletTT&P
O
D
For more information on the Scout Compact Electric Water Heaters contact: State Water Heaters 500 Tennessee Waltz Parkway, Ashland City, TN 37015
800 365-0024 Toll-free USA www.statewaterheaters.com
SMESS00107 January 2008R © 2007 State Industries
C
*
O
Drain
I
*
T
D
B
Plugged Inlet
I*
Plugged Outlet
O*
COMPACT MODELS
*
A
O
T
O
I
ES6 10 SOMS
AO*I*
A
*
O
D
I
D
ES6 20 SOMS
O
I
*
T
T
I
D
ES6 20 SOMT
Loading...