State Industries 200, 201 User Manual

®
SELECT
Residential Gas Water Heaters
High Efficiency
Models Will Qualify
for the Upcoming 2009
Energy Star Program
State Select® gas water heaters feature FVIR Gas Water Heater design, which meets the ANSI Z21.10.1-CSA 4.1 standards for flammable vapor ignition resistance. Select water heaters are available in a variety of heights which can accommodate situations with limited installation space.
• Reduces lime and sediment buildup, maximizes hot water output
• Made from State PEXAN long-term exposure to temperatures up to 400ºF
Green Choice® Gas Burner
• Patented design reduces NOx emissions
• Complies with SCAQMD Rule 1121, Southern California and Texas Approved
RESIDENTIAL
, a cross-linked polymer that can withstand
200/201 Series shown
Easy-to-Light Piezo Ignitor
• For fast “one-hand” pilot ignition
Glass-Lined Tank with Aluminum Anode Rod
• For long-lasting protection against rust and corrosion
Durable Brass Tamper-Resistant Drain Valve
CSA Certified and ASME Rated T&P Relief Valve
Design-Listed by CSA International
• Certified at 300 PSI test pressure and 150 PSI working pressure
• Listed according to ANSZ21.10.1-CSA 4.1 standards governing storage-type water heaters
• Additional code compliance: UBC, CEC, SBCC, CABO, HUD, BOCA National Codes and 2004 NAECA
FVIR Gas Water Heater Design
Simplifies Service
• Uses industry standard thermocouple
• Burner operation may be viewed through new enlarged sight glass
6-Year Limited Tank and Parts Warranty
Consult written warranty or contact State Water Heaters for
complete information
For more information on Select® contact: State Water Heaters 500 Tennessee Waltz Parkway, Ashland City, TN 37015
800.365.0024 Toll-free USA www.statewaterheaters.com
SRGSS02408
August 2008R
®
SELECT
Residential Gas Water Heaters
RESIDENTIAL
MODEL
NUMBER
TALL MODELS
GS6 50 YBRT
SHORT MODEL
GS6 40 YBRS
HIGH EFFICIENCY MODELS
GS6 40 YOCT
GS6 50 YOCT
Recoveries are rounded to nearest gallon. For 10-Year Tank and 6-Year Parts Warranty, change "6" to "X" in Model Number (GSX 40 YBRT). Water Connections – 3/4" male on all models. When ordering Propane, change "Y" to "H" in model number (GS6 40 HBRT). External heat tra p nipples are factory installed on all models. † Propane Gas – 37,000 input for 50-gallon models, 36,000 input for 40-gallon models.
SERIES
200
200
200
200
200
PEAK
DEMAND
OUTPUT
(1st Hour
Rating
Gallons)
88
70
88
ENERGY FACTOR
.62
.62
GALLON
CAPACITY
50
BTU INPUT RECOVERY
PER HOUR 90°F RISE
NATURAL† GALLONS
40,000
41
41
FOAM
THICK-
NESS
(Inches)
1
14140,00050.58
14140,00040.59
2
24140,000
A B C D E F
61-3/4
60-3/4
51-1/2
61-3/4 58-1/4
When or dering top-mounted T&P Valve, add "G" to model number (GS6 40 YBRT G).
Propane (LP) models are Series 201
58-1/4
57
47-3/4
57-1/4
61
DIMENSIONS IN INCHES
18 13 51-3/4
20
20
20
22
13
13 8 41 3 or 4
13
13
8 50-1/4
8 50-1/4
DRAFT
HOOD
OUTLET
3 or 4
51-3/4
3 or 4
3 or 4
Flammable Vapor Ignition Resistant Water Heaters
State FVIR design meets or exceeds the American National Standards Institute standards (ANS Z21.10.1) that deal with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.
Feature a sealed combustion chamber with air intake filter and a flame arrestor built into the water heater base. In addition, a thermal cutoff (TCO) device, is designed to shut off gas flow to the burner and pilot if poor combustion is detected.
ANODE ROD*
OT
H
CONNECTION
APPROX
SHIPPING
WEIGHT
(LBS)
138
153
135
150
165
D
A
B
If flammable vapors accidentally enter the combustion chamber, the arrestor is designed so flames burn off the top surface and can not escape down through the arrestor.
C
A. Industry standard thermocouple B. Large View Port for easy burner inspection C. 3600 combustion air filter D. Thermal Cutoff (TCO) with manual reset
For complete information on limited warranties, consult written warranty, or contact the State Customer Care Center, 1-800-365-0024.
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
For more information on Select® contact: State Water Heaters 500 Tennessee Waltz Parkway, Ashland City, TN 37015
800.365.0024 Toll-free USA www.statewaterheaters.com
SRGSS02408
August 2008R
COLD CONNECTION
E
C
D
T&P VALVE
1/2" GAS CONNECTION
D
*Location for optional top-mounted T&P Valve if ordered from factory.
Maximum Hydrostatic Working Pressure: 150 PSI.
A
B
F