S TAT E P R E M I E R®H Y B R I D E L E C T R I C H E AT P U M P WAT E R H E AT E R S
MORE EFFICIENCY.
MORE SAVINGS.
WITH UP TO 2.4 ENERGY FACTOR (EF), THEY USE LESS THAN HALF
.
THE ELECTRICITY OF STANDARD ELECTRIC WATER HEATERS
A NEW ERA IN ELECTRIC WATER HEATING.
For years, there have been few high efficiency
options for homeowners that have an electric
water heater. That’s because there were few
technological advances in electric water heating.
But all that changes now, with State Premier
®
Hybrid Electric Heat Pump Water Heaters. Our new
advanced design integrates heat pump technology
to create a product that is twice as efficient as a
standard electric water heater. It’s the most versatile
and energy-efficient option for homeowners looking
for cost savings and performance.
Premier Hybrid Electric Heat Pump Water
Heaters offer up to a 2.4 Energy Factor (EF). The
design features an integrated heat pump with high
efficiency compressor and external coil heat
exchanger, with back-up electric elements. This
combination provides greater energy efficiency
and more energy savings, while providing multiple
modes of operation for greater flexibility. Also,
these models come with a powered anode rod that
protects the tank for the entire life of the heater and
allows better performance in a variety of water
conditions.
Designed to cut energy costs
by more than half.
If you were to combine the energy used by a
household’s refrigerator, dishwasher, clothes
washer and clothes dryer, all of those appliances
together would still use less energy than the
standard water heater.
That’s why State developed its Premier Hybrid
Electric Heat Pump Water Heaters. They actually
create more hot water than a standard electric
water heater, but use significantly less energy.
It’s a product that plumbers, wholesalers and
homeowners can appreciate.
In fact, State Premier Hybrid
Electric Heat Pump Water
Heaters can save the average
household about $360 per year
on their electricity bills compared
to a standard electric water
heater. That’s a savings of more
than $4,200 over a 12-year
period. With a payback period
Typical U.S. Household
Energy Use
29% Heating
17% Cooling
14% Water Heater
13% Appliances
12% Lighting
11% Other
4% Electronics
of three years or less, State
Premier Hybrid Electric Heat Pumps are a great
solution for an energy-efficient upgrade.
Compare the energy costs with State Premier Hybrid Electric Heat Pumps.
STANDARD
ELECTRIC
$
ENERGY STAR
QUALIFIED
HYBRID ELECTRIC
®
360
In Savings
$0$100$200$300$400$500$600
Annual Energy Costs ($/year)
Based on average household of 2.6 occupants. U.S. Census, 2006
Source: DOE website—www.energystar.gov/index.cfm?c=heat_pump_savings_benefits
HOW THEY WORK.
In “Efficiency” mode, State Premier Hybrid Electric
Heat Pump Water Heaters operate automatically to
heat water in the following manner:
1. A fan brings air through the top air filter.
1.
3.
4.
2.
2. Heat in the air is absorbed by the refrigerant
inside the evaporator coil.
3. The refrigerant is pumped through a compressor,
which raises the temperature.
4. Hot refrigerant is circulated through the copper
coil and transfers heat to the water.
5. The copper coil and storage tank are surrounded
by 2 inches of “Environmentally-Friendly”
Non-CFC foam insulation to reduce standby heat
loss.
5.
GREATER STORAGE CAPACITY TRANSLATES
TO MORE ENERGY SAVINGS.
State Premier Hybrid Electric Heat Pump Water
Heaters have higher capacity, designed
to optimize the impact of the efficient heat pump
technology. More storage capacity lets you store
more of the hot water that was created
by the heat pump. This capacity also enables the
unit to operate in the maximum efficiency mode
more often than other models with lower capacities.
Large capacity allows use across
all geographic zones.
State Premier Hybrid Electric Heat Pump Water
Heaters can be effectively used in all areas
of the U.S. Based on ambient conditions, hybrid
mode allows both of the heating components –
heat pump and traditional heating elements –
to operate in order to provide optimal performance.
Region 1: Heat pump will be used most
of the year
Region 2: Majority heat pump operation
Region 3
Region
Region 1
Region 3: Combination heat pump and
electric heating elements
2
Savings Are Greater Where Electricity Rates Are Highest
The greatest savings and quickest payback can often be in regions where the average temperatures are colder.
Operating 5 months out the year in the heat pump mode where electricity rates are two to three times higher will
yield more savings than operating 10 months in the heat pump mode where electricity rates are lower.
ADVANCED ELECTRONIC CONTROL.
USER INTERFACE
• Large LCD touch pad display in plain English
provides easy interaction.
• Safety lock feature prevents unwanted access.
• Status icons clearly indicate current operating mode.
• Three-line display communicates current status in
plain English.
• Individual buttons allow homeowner to choose from
four operating modes: Efficiency, Hybrid, Electric
and Vacation.
Choose from four operational modes.
Choose the right efficiency setting, based on climate,
demand and installation.
Efficiency Mode – The most energy-efficient setting
utilizes only the heat pump to extract warmth from
the surrounding air and transfer it to the water.
This mode provides up to 2.4 Energy Factor (EF).
This extra capacity allows it to operate in the efficiency
mode more frequently than smaller capacity units.
Hybrid Mode – When hot water demand is at its
peak, this setting utilizes both the heat pump and
conventional electric element to provide the needed
amount of hot water. This mode will provide a highly
efficient 2.33 EF.
Electric Mode – In electric mode, the unit operates as a
conventional electric model utilizing the elements only
to provide quick recovery.
Vacation Mode – One touch operation maintains tank
temperatures of 60oF (15.6oC) during vacation or
extended absense to reduce operating costs and provide
freeze protection.
TAT E P R E M I E R
S
®
Y B R I D E L E C T R I C H E AT P U M P WAT E R H E AT E R S
H
State Premi er Hybrid Ele ctric Heat Pump Water Heaters
ODEL
M
NUMBER
EPX-60DHPT60
EPX-80DHPT
ALLON
G
CAPACITY
80
ENERGY FACTOR BY MODEFIRST HOUR RATING BY MODE
EFFICIENCYHYBRIDELECTRIC EFFICIENCYHYBRIDELECTRIC
2.402.33.8851
2.302.33
.85708476
ENERGY STAR®QUALIFIED.
State Premier Hybrid Electric Heat Pump Water Heaters meet
®
ENERGY STAR
qualifications.
68
EIGHT
H
(INCHES)
6667-1/324-1/2365
81-1/2
IAMETER
D
(INCHES)
24-1/2
SHIPPING
WEIGHT
(LBS)
410
Contact your sales
representative for more information.
State Water Heaters
500 Tennessee Waltz Pkwy., Ashland City, TN 37015
800-365-0024 Toll-free USA
statewaterheaters.com
Part #SRXBR00110 Revised 2012
May
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.