State EPX-60DHPT User Manual

S TAT E P R E M I E R®H Y B R I D E L E C T R I C H E AT P U M P WAT E R H E AT E R S
MORE EFFICIENCY. MORE SAVINGS.
WITH UP TO 2.4 ENERGY FACTOR (EF), THEY USE LESS THAN HALF
.
THE ELECTRICITY OF STANDARD ELECTRIC WATER HEATERS
For years, there have been few high efficiency options for homeowners that have an electric water heater. That’s because there were few technological advances in electric water heating.
But all that changes now, with State Premier
®
Hybrid Electric Heat Pump Water Heaters. Our new advanced design integrates heat pump technology to create a product that is twice as efficient as a standard electric water heater. It’s the most versatile and energy-efficient option for homeowners looking for cost savings and performance.
Premier Hybrid Electric Heat Pump Water Heaters offer up to a 2.4 Energy Factor (EF). The design features an integrated heat pump with high efficiency compressor and external coil heat exchanger, with back-up electric elements. This combination provides greater energy efficiency and more energy savings, while providing multiple modes of operation for greater flexibility. Also, these models come with a powered anode rod that protects the tank for the entire life of the heater and allows better performance in a variety of water conditions.
Designed to cut energy costs by more than half.
If you were to combine the energy used by a household’s refrigerator, dishwasher, clothes washer and clothes dryer, all of those appliances together would still use less energy than the standard water heater.
That’s why State developed its Premier Hybrid Electric Heat Pump Water Heaters. They actually create more hot water than a standard electric water heater, but use significantly less energy. It’s a product that plumbers, wholesalers and homeowners can appreciate.
In fact, State Premier Hybrid Electric Heat Pump Water Heaters can save the average household about $360 per year on their electricity bills compared to a standard electric water heater. That’s a savings of more than $4,200 over a 12-year period. With a payback period
Typical U.S. Household Energy Use
29% Heating 17% Cooling
14% Water Heater
13% Appliances 12% Lighting 11% Other 4% Electronics
of three years or less, State Premier Hybrid Electric Heat Pumps are a great solution for an energy-efficient upgrade.
Compare the energy costs with State Premier Hybrid Electric Heat Pumps.
STANDARD ELECTRIC
$
ENERGY STAR QUALIFIED HYBRID ELECTRIC
®
360
In Savings
$0 $100 $200 $300 $400 $500 $600
Annual Energy Costs ($/year)
Based on average household of 2.6 occupants. U.S. Census, 2006 Source: DOE website—www.energystar.gov/index.cfm?c=heat_pump_savings_benefits
HOW THEY WORK.
In “Efficiency” mode, State Premier Hybrid Electric Heat Pump Water Heaters operate automatically to heat water in the following manner:
1. A fan brings air through the top air filter.
1.
3.
4.
2.
2. Heat in the air is absorbed by the refrigerant inside the evaporator coil.
3. The refrigerant is pumped through a compressor, which raises the temperature.
4. Hot refrigerant is circulated through the copper coil and transfers heat to the water.
5. The copper coil and storage tank are surrounded by 2 inches of “Environmentally-Friendly” Non-CFC foam insulation to reduce standby heat loss.
5.
GREATER STORAGE CAPACITY TRANSLATES TO MORE ENERGY SAVINGS.
State Premier Hybrid Electric Heat Pump Water Heaters have higher capacity, designed to optimize the impact of the efficient heat pump technology. More storage capacity lets you store more of the hot water that was created by the heat pump. This capacity also enables the unit to operate in the maximum efficiency mode more often than other models with lower capacities.
Large capacity allows use across all geographic zones.
State Premier Hybrid Electric Heat Pump Water Heaters can be effectively used in all areas of the U.S. Based on ambient conditions, hybrid mode allows both of the heating components – heat pump and traditional heating elements – to operate in order to provide optimal performance.
Region 1: Heat pump will be used most
of the year
Region 2: Majority heat pump operation
Region 3
Region
Region 1
Region 3: Combination heat pump and
electric heating elements
2
Savings Are Greater Where Electricity Rates Are Highest
The greatest savings and quickest payback can often be in regions where the average temperatures are colder.
Operating 5 months out the year in the heat pump mode where electricity rates are two to three times higher will
yield more savings than operating 10 months in the heat pump mode where electricity rates are lower.
ADVANCED ELECTRONIC CONTROL.
USER INTERFACE
• Large LCD touch pad display in plain English provides easy interaction.
• Safety lock feature prevents unwanted access.
• Status icons clearly indicate current operating mode.
• Three-line display communicates current status in
plain English.
• Individual buttons allow homeowner to choose from
four operating modes: Efficiency, Hybrid, Electric and Vacation.
Choose from four operational modes.
Choose the right efficiency setting, based on climate, demand and installation.
Efficiency Mode – The most energy-efficient setting utilizes only the heat pump to extract warmth from the surrounding air and transfer it to the water. This mode provides up to 2.4 Energy Factor (EF). This extra capacity allows it to operate in the efficiency mode more frequently than smaller capacity units.
Hybrid Mode – When hot water demand is at its peak, this setting utilizes both the heat pump and conventional electric element to provide the needed amount of hot water. This mode will provide a highly efficient 2.33 EF.
Electric Mode – In electric mode, the unit operates as a conventional electric model utilizing the elements only to provide quick recovery.
Vacation Mode – One touch operation maintains tank temperatures of 60oF (15.6oC) during vacation or extended absense to reduce operating costs and provide freeze protection.
TAT E P R E M I E R
S
®
Y B R I D E L E C T R I C H E AT P U M P WAT E R H E AT E R S
H
State Premi er Hybrid Ele ctric Heat Pump Water Heaters
ODEL
M
NUMBER
EPX-60DHPT 60
EPX-80DHPT
ALLON
G
CAPACITY
80
ENERGY FACTOR BY MODE FIRST HOUR RATING BY MODE
EFFICIENCY HYBRID ELECTRIC EFFICIENCY HYBRID ELECTRIC
2.40 2.33 .88 51
2.30 2.33
.85 70 84 76
ENERGY STAR®QUALIFIED.
State Premier Hybrid Electric Heat Pump Water Heaters meet
®
ENERGY STAR
qualifications.
68
EIGHT
H
(INCHES)
66 67-1/3 24-1/2 365
81-1/2
IAMETER
D
(INCHES)
24-1/2
SHIPPING
WEIGHT
(LBS)
410
Contact your sales representative for more information.
State Water Heaters 500 Tennessee Waltz Pkwy., Ashland City, TN 37015
800-365-0024 Toll-free USA statewaterheaters.com
Part #SRXBR00110 Revised 2012