Star systems Platino WF2014 User Manual

Platino Handheld Reader
User Guide
Revision 1.1
STAR Systems International Limited
Unit A01, 24/F, Gold King Industrial Building 35-41 Tai Lin Pai Road, Kwai Chung New Territories, Hong Kong SAR Tel: +852-3691-9925
www.star-int.net technical@star-int.net
Page 1
Reader Overview
1. ENTER
2. READ
3. SETTING
4. POWER
5. DIRECTIONS (UP, DOWN, LEFT, RIGHT)
6. NUMBER PAD (1,2,30,*,#)
7. FUNCTION 1 (F1)
8. FUNCTION 2 (F2)
9. FUNCTION 3 (F3)
10. Hard Reset Button (Under the rubber grip)
Revision 1.1
STAR Systems International Limited
Unit A01, 24/F, Gold King Industrial Building 35-41 Tai Lin Pai Road, Kwai Chung New Territories, Hong Kong SAR Tel: +852-3691-9925
www.star-int.net technical@star-int.net
Page 2
Basic Operations
Starting up Platino
Press the POWER button for a 2 seconds to power up the device. A beep sound should be heard and the main screen with the above information is shown when Platino is booted up.
Reading tags
Press the READ button while Platino is ON. Put an ISOC tag near the antenna area and you should be able to read the tags EPC number.
Wireless Connectivity
Platino offers 2 types of wireless connectivity: WiFi and Bluetooth (BLE). User can check the connection type by the icon displayed next to the battery sign.
Bluetooth (BLE)
WiFi
Shutting down Platino
Press the POWER button for 2 seconds while Platino is ON. The main screen will shut down and a short been will be heard.
Revision 1.1
STAR Systems International Limited
Unit A01, 24/F, Gold King Industrial Building 35-41 Tai Lin Pai Road, Kwai Chung New Territories, Hong Kong SAR Tel: +852-3691-9925
www.star-int.net technical@star-int.net
Page 3
Read/Write Mode Selection
Press ENTER in any of the read/write mode to enter the read/write mode selection menu. Use the UP or DOWN button to navigate through different mode options and press ENTER to enter any of the available read/write mode.
Read Single Tag
Read data in different memory banks of a single tag. Data from only 1 tag will be displayed at a time. The data will also be automatically store in the reader memory and transmitted to the mobile app if available.
Read Multiple Tag
Read EPC from multiple tags in the reader vicinity. User can manually save the tags EPC to the reader memory with the function button. Up to 100 tags can be saved at a time.
Write Tag
Write data to different memory banks of a tag.
Lock/Kill Tag
Change the lock state of different memory banks of a tag with access password or disable a tag permanently with the kill password.
Block Read Lock
Custom command for Alien H3 chip which allows user to “read lock” different
memory blocks of the user memory bank in a tag. Read locked data can only be viewed if the correct access password is provided.
Read Barcode
Read 1D barcode with the build-in barcode reader. User can manually save the barcode data to the reader memory with the function button.
Revision 1.1
STAR Systems International Limited
Unit A01, 24/F, Gold King Industrial Building 35-41 Tai Lin Pai Road, Kwai Chung New Territories, Hong Kong SAR Tel: +852-3691-9925
www.star-int.net technical@star-int.net
Page 4
Reading Different Memory Banks
Platino starts in Read Single Tag mode. In this mode user can read a single tag by pressing the READ button. User can press LEFT and RIGHT button to select different memory banks to read. The following options are available:
1. Read EPC
2. Read TID
3. Read User Data
4. Read EPC + TID
5. Read EPC + User Data
6. Read All Data
User can press UP or DOWN button to select the Access Password field. The field will be highlighted in blue once it is selected. Press F1 to switch between different input methods (number/alphabet) for the Access Password field. Access Password can be used to read memory bank that is “read-locked”.
Tag data read in this mode will be automatically stored in the file SINGLE.TXT in the reader memory. Please refer to the Collecting Data section of this manual for more information.
NOTE: Reading TID, User Memory and All Data may require more energy than reading the EPC number only. Please place the tag in close proximity to the antenna while attempting to read the TID, User Memory and All Data.
Revision 1.1
STAR Systems International Limited
Unit A01, 24/F, Gold King Industrial Building 35-41 Tai Lin Pai Road, Kwai Chung New Territories, Hong Kong SAR Tel: +852-3691-9925
www.star-int.net technical@star-int.net
Page 5
Reading Multiple Tags
Read Multiple Tag mode allows user to read multiple tags EPC simultaneously.
Press and hold the READ button to start reading tags. Any tag that is read will generate and new entry on the screen
with the tag’s EPC and read count shown. The total
number of distinct tags is shown at the bottom of the screen.
Maximum of 9 tags can be displayed simultaneously on the screen, user can press the UP or DOWN button to go through the tag list and view the tags in the next page (e.g. if a total number of 27 tags are read, there will be 3 pages of data available).
Press F1 to save the data into MULTIPLE.TXT in the reader memory. Please refer to the Collecting Data section of this manual for more information. The tag list on the screen will be cleared afterwards.
If user selected one of the tag with UP or DOWN button, pressing F2 will pass the selected EPC to the WRITE TAG mode so user can write data to the tag with specific EPC.
Press F3 to clear the tag list on screen.
Revision 1.1
STAR Systems International Limited
Unit A01, 24/F, Gold King Industrial Building 35-41 Tai Lin Pai Road, Kwai Chung New Territories, Hong Kong SAR Tel: +852-3691-9925
www.star-int.net technical@star-int.net
Page 6
Writing Data to Tag
Write Tag mode allow user to write data to different memory bank of a specific tag.
Target EPC
User need to input a Target EPC through one of the following methods:
1. Press F1 in Write Tag mode to read a new tag. The tag’s EPC will
be displayed in the Target EPC field.
2. Read a tag in Read Single Tag mode, then press F2 to pass the
EPC of that tag to Write Tag mode
3. Read tags in Read Multiple Tag mode, use UP or DOWN button
to select one of the tag, then press F2 to pass the EPC of that tag to Write Tag mode
4. Manually input the Target EPC using the keyboard
Memory Bank
Once a target EPC is established, user can choose among the following field to write
1. Kill Password
2. Access Password
3. EPC
4. TID (not available)
5. User
Start Pointer
The start position of memory bank to write. Each pointer represent 16 bit (4 hexadecimal word) of data. Please note that Point 0 of EPC (checksum) is not available for writing.
Loading...