These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves the
manufacturer of all liability.
Star reserves the right to change specications and product design without
notice. Such revisions do not entitle the buyer to corresponding changes,
improvements, additions or replacements for previously purchased
equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specications contained in this sheet are subject to change
without notice. While Star International Holdings Inc., Company exercises
good faith efforts to provide information that is accurate, we are not
responsible for errors or omissions in information provided or conclusions
reached as a result of using the specications. By using the information
provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance.
Please record the model number, serial number, voltage and purchase date in the area below and have it ready when
you call to ensure a faster service.
SAFETY SYMBOL
Model No.
Serial No.
Voltage
Purchase Date
Business8:00 am to 4:30 p.m. Central Standard Time
Hours:
This equipment is designed and sold for commercial use only by personnel trained and experienced
in its operation and is not sold for consumer use in and around the home nor for use directly by the
general public in food service locations.
Before using your new equipment read and understand all the instructions & labels associated with
the unit prior to putting it into operation. Make sure all people associated with its use understand the
units operation & safety before they use the unit.
All shipping containers should be checked for freight damage both visible and concealed. This
unit has been tested and carefully packaged to insure delivery of your unit in perfect condition. If
equipment is received in damaged condition, either apparent or concealed, a claim must be made
with the delivering carrier.
Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked, a
request for inspection of concealed damage must be made with carrier within 15 days. Be certain to
retain all contents plus external and internal packaging materials for inspection. The carrier will make
an inspection and will supply necessary claim forms.
These models are equipped for the voltage and wattage indicated on the nameplate. These units
are designed to operate on alternating current (A.C.), two wire single phase service only and are
equipped with an approved lead in cord set with a three prong grounding type plug.
DO NOT CONNECT TO DIRECT CURRENT (D.C.).
UNPACKING
Carefully remove the steamer from the shipping and packing & protective material. Remove all
removable parts and clean with hot water and mild detergent. Wipe the unit using damp cloth. Never
hose down the unit with water, this steamer has
Unit should also contain:
• Operations manual & Authorized Service Agent Listing Packet
• Inlet Hose Assembly (non-reservoir units only)
• Spatula tray (front loading units only)
Purchasers Responsibility
• To see that the electric & water services for the unit are installed on site in accordance with
the manufacturer's specications and municipal codes.
• A water pressure regulator must be used, failure to operate this unit without a regulator will
result in situations that will damage the unit.
2M-Z10887 Owners Manual Fast Steamers
4
WARNING
CAUTION
INSTALLATION
ELECTRICAL CONNECTION
For your protection, we recommend that a qualied electrician install this appliance.
The electrician should be familiar with electrical installations and your local electrical requirements.
Proper connections and power supply are essential for efcient performance. The supply circuit should
be properly fused as required by local electrical code.
Before making any electrical connection be sure to read data plate which is located on the rear
of the unit.
Electrical Grounding Instructions
This unit is equipped with a 3-prong (grounded) plug for your protection against shock hazard and must
be plugged directly into a properly grounded 3-prong receptacle.
DO NOT CUT OR REMOVE THIS PLUG OR GROUNDED PRONG FROM THE
PLUG.
CONNECT/PLUG UNIT INTO DEDICATED A.C. LINE ONLY SPECIFIED ON THE
DATA PLATE OF THE UNIT.
PRESET TIME
If adjustments are required, please refer to the time programming section in this manual.
°F/°C CONVERSION
To change the temperature display from °F to °C or from °C to °F, hold the TEMP button while the
unit is turned off. While holding the TEMP button, turn the unit on. The display will be the changed
temperature mode. To change back, repeat the procedure.
2M-Z10887 Owners Manual Fast Steamers
5
INSTALLATION continued
Filter
Regulator
To Steamer
Guage
Water
Source
26 psi
IL1532
Lid
Strainer
Water Inlet
IL1537
WATER CONNECTION
These units come equipped with either a direct connect, rear mounted quick disconnect uid control
valve, or a 12 cup water tank with tank drain and supply pump. It is vital that all water supply lines be
thoroughly ushed with clean water before being connected to the steamer.
The Star Fast-Steamer has a water injection system, to ensure your new equipment works at its
premium, we recommend that a water softener is used in areas where hard water is present. Contact
your local water equipment system provider to assist you in determining your specic water quality, or
contact Star Technical support for assistance, 314-678-6303.
Direct Connect Water Supply Installation
1. Make certain the water valve that
will be suppling the unit is turned
off.
2. Connect the 1/4" I.D. exible
tubing to the outlet side of the water
source and secure with clamps
provided.
3. Holding the end opposite end
over a bucket, turn the water valve on until there is a good consistent supply of water
(this removes any air from the system and ushes it of any particles that may be present).
urn off the water valve.
4. T
5. Push the check valve tting into the water inlet located on the rear of the unit.
Make certain the connection is securely attached by lightly tugging on it.
6. T
urn on water valve, Turn the knob on the regulator until the guage reads 26 psi.
Check for leaks.
Reservoir Water Units
1. With unit in nal position, open reservoir lid.
2. Check and make sure the reservoir is free of debris
and material that may interfere with its operation.
3. The unit comes with a washer strainer which ts
over the water inlet (see illustration), verify this is
correctly in position. Periodically check strainer and
clean and replace as often as necessary
4. Pour tap water into reservoir until the water level is
1/4" from the top.
5. Closed lid.
Check water level during daily operation and ll as needed.
6.
.
2M-Z10887 Owners Manual Fast Steamers
6
CAUTION
OPERATING PROCEDURE
Connect your unit to a wall outlet which will supply the unit with the proper voltage specied on the
data plate. If you have a reservoir unit, verify the water level, add if water is low.
KEEP HANDS AND FACE AWAY FROM THE UNIT WHEN OPENING OR
REMOVING THE SPATULA FROM THE UNIT. STEAM ESCAPING IS VERY HOT.
MANUAL CONTROL
• Turn unit on
Wait 20 - 30 minutes for the unit to reach its operating temperature before using.
Note: The Temperature Set Point is factory xed at 400°F (204°C) and is not adjustable.
• Place product in cooking chamber and hit the Steam Shot button to steam the product.
Steam Shot: Pressing the Green Steam Shot Green Button will release water in to the steam
generator and will instantly produce steam. Water will only stop when the button is released.
Flooding of the steam generator may occur if the Steam Shot button, or the SST is set to high. When
this occurs wait for the unit to work through the water before applying more water to the steam
generator.
ELECTRONIC CONTROL
• Turn unit on
Current Temperature will Flash on LED, PRESS the
TEMP button to see current temperature
TCT will FLASH until
Alarm will sound 3-times when TSP is reached.
Note: The Temperature Set Point is factory xed at 400°F (204°C) and is not adjustable.
• Place product in cooking chamber and choose one of the 4 pre-determined programmed
settings, or hit the Steam Shot steam button to steam the product.
• When program timing is completed, an alarm will sound.
TSP (Temperature Set Point) is reached,
PROGRAMMING DEFINITIONS
TCT Total Cook Time
Shot Interval Time
SIT
SST Steam Shot Time
TSP Temp Set Point
Steam Shot: Pressing the Green Steam Shot Button will release water in to the steam generator
and will instantly produce steam. Water will only stop when the button is released. Flooding of the
steam generator may occur if the Steam Shot button, or the SST is set to high. When this occurs wait
for the unit to vaporize all of the water before applying more water to the steam generator.
1. The preset time will ash until the operating temperature is reached.
2. When the control reaches preset temperature, time display, "Heat On" indicator and program
indicator will stop ashing and the alarm will beep three times.
Temperature:
1.To view the actual steam generator temperature, press and hold "Temp Button."
2M-Z10887 Owners Manual Fast Steamers
7
OPERATION continued
90 degrees
60 degrees
Cover
Stop
IL1366
To Program Time:
The program buttons factory pre-set are listed below.
If changes are required follow these simple steps.
Note, any changes to these settings are stored in
the units memory until changed. Returning to the
PROGRAMMING SPECIFICATIONS / RANGE
TCT Total Cook Time 0 to 99.59 minutes
SIT
Shot Interval Time .5sec to 10 minutes
SST Steam Shot Time .1 sec to 5.minutes
TSP Temp Set Point
factory pre-sets is not available automatically.
1. Press and hold "TEMP"
(actual temperature displays).
2. While holding "TEMP
," press and hold any
program button for one second, to begin
programming
3. TCT(Total Cook Time) will display, adjust
TCT20 sec40 sec1 min1.30 min
SIT20 sec40 sec40 sec40 sec
SST.5 sec.5 sec.5 sec.5 sec
Program Button Factory Presets
1234
time with the "3 or 4" buttons.
• Press the #1 button to move to between minutes and seconds.
• Press the #1 button to move to SIT.
SIT (Shot Interval Time) will display, adjust time with the "3 or 4" buttons.
.
4
• Press the #1 button to move to between minutes and seconds.
• Press the #1 button to move to SST.
SST (Steam Shot Time) will display, adjust time with the "3 or 4" buttons.
5.
• Press the #1 button to move to seconds.
Press the "TEMP" button to save time settings and to exit programming mode for this
6.
program. Your program will not be saved if this step is not done within 10 seconds.
7. Repeat process to program for additional programming
Hi-Limit Reset
A hi-limit reset monitors the temperature of the steam generator and will turn the power off to the unit to
prevent it from overheating. If this occurs, the unit will automatically reset when it has had enough time to
cool prior to returning to operation. If this occurs on a regular basis it may be a sign of a larger problem,
call your service agent or Star Manufacturing at
314-678-6303.
TOP LOADING COVER STOP
SETTINGS
Top Loading Fast Steamer models (FS1 &
FS2) are designed with adjustable cover
stops located on the back of the units. As
shown here you can adjust your unit's
top cover between an opening of 60°
- 90°.
2M-Z10887 Owners Manual Fast Steamers
8
CLEANING
DO NOT USE CAUSTIC CLEANERS,
CAUTION
WARNING
CAUTION
USE A MILD DETERGENT TO WIPE DOWN EXTERIOR SURFACES, CLEAN
WITH DAMP CLOTH
Daily
1. Turn the unit OFF & unplug the unit from its power source before proceeding with any service
or cleaning procedure.
2. Remove and clean the removable items listed on the maintenance components illustration for
your specic model. Clean using warm water and mild detergent. DRY parts completely
3. Wipe the exterior or the steamer with a damp cloth, then wipe dry. Note: drying all pieces
after cleaning will protect your nish from discoloration, any discoloration as a result from not
drying the equipment is not covered under warranty
4. Reinstall the unit, beginning with the Steam V
ent.
.
Monthly
The Star Fast Steamer generates instant steam by means of its open generator, however the mineral
deposits in the water are left behind. A certain amount of deposits are needed for proper operation,
but a build-up of calcium & mineral deposits may cause poor performance. It is important to properly
maintain you steamer to ensure quality operation. Depending on your specic water conditions and
possibly any water ltration systems, you may need to clean your steamer more or less frequently.
DO NOT IMMERSE OR LET THE UNIT STAND IN WATER. DO NOT HOSE
DOWNTHE UNIT. KEEP THE UNIT AWAY FROM RUNNING WATER.
DO NOT SPLASH THE CONTROL HOUSING
CERTAIN WATER CONDITIONS MAY REQUIRE MORE FREQUENT CLEANING.
BEFORE CLEANING MAKE SURE POWER IS TURNED OFF AND UNIT IS
WARNING
UNPLUGGED.
IF A CHEMICAL CLEANER / DELIMER IS USED, BE CERTAIN IS IT SAFE FOR
CAST ALUMINUM. FOLLOW PROCEDURES, PRECAUTIONS PROVIDED WITH
CAUTION
2M-Z10887 Owners Manual Fast Steamers
THAT SPECIFIC PRODUCT.
9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.