Star Manufacturing FSF, FS1 Parts List

Page 1
FAST
STEAMER
MODEL
FS1R, FS1D, FS1RT, FS1DT FS2R, FS2D, FS2RT, FS2DT
FSFR, FSFD, FSFRT, FSFDT
Installation and
Operation
2M-Z10887 Rev. A 10/29/2007
FS2DT
FSFRT
1
Page 2
SAFETY SYMBOL
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change specifi cations and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the specifi cations contained in this sheet are subject to change without notice. While Star Manufacturing exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifi cations. By using the information provided, the user assumes all risks in connection with such use.
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to
ensure faster service.
Model No.
Serial No.
Voltage
Purchase Date
Authorized Service Agent
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com E-mail Service@star-mfg.com Telephone: (800) 807-9054 Local (314) 781-2777
The Star Service Help Desk
Business 8:00 am to 4:30 p.m. Central Standard Time Hours:
Telephone: (800) 807-9054 Local (314) 781-2777
Fax: (800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com Warranty@star-mfg.com
Website: www.star-mfg.com
Mailing Address: Star Manufacturing International Inc.
10 Sunnen Drive St. Louis, MO 63143 U.S.A
2
2
Page 3
SPECIFICATIONS
C
C
B
A
B
IL1361
A
FRONT LOADING TOP LOADING
FAST STEAMERS SPECIFICATIONS
FRONT LOADING
Model "A" Width "B" Height "C" Depth Approx. Capacity (inches) Direct (D) No. Inches/CM Inches/CM Inches/CM Shp Weight W_x_D_x_H Reservoir (R)
FSFR 23in. / 58.4cm 9.5in / 24.1c, 21.5in / 54.4cm 48lbs / 21.8kg 13.75" x 13.75" x 3" R FSFD 23in. / 58.4cm 9.5in / 24.1c, 21.5in / 54.4cm 48lbs / 21.8kg 13.75" x 13.75" x 3" D FSFRT 23in. / 58.4cm 9.5in / 24.1c, 21.5in / 54.4cm 48lbs / 21.8kg 13.75" x 13.75" x 3" R FSFDT 23in. / 58.4cm 9.5in / 24.1c, 21.5in / 54.4cm 48lbs / 21.8kg 13.75" x 13.75" x 3" D
TOP LOADING Pan Size
FS1R 18.8in / 47.8cm 10.5in / 26.7cm 17.2in / 43.7cm 48lbs / 21.8kg 1/2 R FS1D 18.8in / 47.8cm 10.5in / 26.7cm 17.2in / 43.7cm 48lbs / 21.8kg 1/2 D FS1RT 18.8in / 47.8cm 10.5in / 26.7cm 17.2in / 43.7cm 48lbs / 21.8kg 1/2 R FS1DT 18.8in / 47.8cm 10.5in / 26.7cm 17.2in / 43.7cm 48lbs / 21.8kg 1/2 D FS2R 22.4in / 56.9cm 10.5in / 26.7cm 17.2in / 43.7cm 58lbs / 26.4kg 2/3 R FS2D 22.4in / 56.9cm 10.5in / 26.7cm 17.2in / 43.7cm 58lbs / 26.4kg 2/3 D FS2RT 22.4in / 56.9cm 10.5in / 26.7cm 17.2in / 43.7cm 58lbs / 26.4kg 2/3 R FS2DT 22.4in / 56.9cm 10.5in / 26.7cm 17.2in / 43.7cm 58lbs / 26.4kg 2/3 D
ELECTRICAL SPECIFICATIONS
Front Loading Certifi cation
Model No. Voltage Wattage Amps Nema Plug UL CUL
FSF 208V 3,300 15.9 6-20P X X FSF 240V 3,600 15.0 6-20P X X
Top Loading
Model No. Voltage Wattage Amps Nema Plug
FS1/FS2 120V 1,800 15.0 5-15P X ­ FS1/FS2 120VC 1,800 15.0 5-20P X X
3
Page 4
GENERAL INFORMATION
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and
experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations.
Before using your new equipment read and understand all the instructions & labels
associated with the unit prior to putting it into operation. Make sure all people associated with its use understand the units operation & safety before they use the unit.
All shipping containers should be checked for freight damage both visible and concealed.
This unit has been tested and carefully packaged to insure delivery of your unit in perfect condition. If equipment is received in damaged condition, either apparent or concealed, a claim must be made with the delivering carrier.
Concealed damage or loss - if damage or loss is not apparent until after equipment is
unpacked, a request for inspection of concealed damage must be made with carrier within 15 days. Be certain to retain all contents plus external and internal packaging materials for
inspection. The carrier will make an inspection and will supply necessary claim forms.
These models are equipped for the voltage and wattage indicated on the nameplate. These units are designed to operate on alternating current (A.C.), two wire single phase service only and are equipped with an approved lead in cord set with a three prong grounding type plug.
DO NOT CONNECT TO DIRECT CURRENT (D.C.).
UNPACKING
Carefully remove the steamer from the shipping and packing & protective material. Remove all removable parts and clean with hot water and mild detergent. Wipe the unit using damp cloth. Never hose down the unit with water, this steamer has
Unit should also contain:
• Operations manual & Authorized Service Agent Listing Packet
• Inlet Hose Assembly (non-reservoir units only)
• Spatula tray (front loading units only)
Purchasers Responsibility
• To see that the electric & water services for the unit are installed on site in accordance with the manufacturer's specifi cations and municipal codes.
• A water pressure regulator must be used, failure to operate this unit without a regulator will result in situations that will damage the unit.
4
Page 5
INSTALLATION
ELECTRICAL CONNECTION
For your protection, we recommend that a qualifi ed electrician install this appliance. The electrician should be familiar with electrical installations and your local electrical requirements. Proper connections and power supply are essential for effi cient performance. The supply circuit should be properly fused as required by local electrical code.
WARNING
Before making any electrical connection be sure to read data plate which is located on the rear of the unit.
Electrical Grounding Instructions
This unit is equipped with a 3-prong (grounded) plug for your protection against shock hazard and must be plugged directly into a properly grounded 3-prong receptacle.
CAUTION
DO NOT CUT OR REMOVE THIS PLUG OR GROUNDED PRONG FROM THE PLUG. CONNECT/PLUG UNIT INTO DEDICATED A.C. LINE ONLY SPECIFIED ON THE DATA
PLATE OF THE UNIT.
WATER CONNECTION
These units come equipped with either a direct connect, rear mounted quick disconnect fl uid control valve, or a 12 cup water tank with tank drain and supply pump. It is vital that all water supply lines be thoroughly fl ushed with clean water before being connected to the steamer.
The Star Fast-Steamer has a water injection system, to ensure your new equipment works at its premium, we recommend that a water softener is used in areas where hard water is present. Contact your local water equipment system provider to assist you in determining your specifi c water quality, or contact Star Technical support for assistance, 1-800-807-9054.
Direct Connect Water Supply Installation
1. Turn off water valve that will be suppling the unit.
2. Connect the 1/4" I.D. fl exible tubing to the outlet side of the water pressure regulator
(not provided) and secure with clamp provided.
3. Holding the end of the Water Filter Supply Line over a bucket, turn the water valve on
until there is a good consistent supply of water (this removes any air from the system and fl ushes it of any particles that may be present. Note the reading on the water pressure regulator gauge, it should read 20-25 PSI. If it reads more of less, adjust regulator until it falls into the proper range.
4. Push the check valve fi tting into the water inlet located on the rear of the unit.
Make certain the connection is securely attached by lightly tugging on it.
Reservoir Water Units
1. With unit in fi nal position, open reservoir cover.
2. Check and make sure the reservoir is free of debris and material that may interfere
with operation.
3. Pour tap water into reservoir unit the water level is 1/4" from the top.
4. Slide door closed.
5. Check water level during daily operation and fi ll when needed.
PRESET TIME
If adjustments are required, please refer to the time programming section in this manual.
°F/°C CONVERSION
To change the temperature display from °F to °C or from °C to °F, hold the TEMP button while the unit is turned off. While holding the TEMP button, turn the unit on. The display
will be the changed temperature mode. To change back, repeat the procedure.
5
Page 6
OPERATING PROCEDURE
Connect your unit to a wall outlet which will supply the unit with the proper voltage specifi ed on the data plate. If you have a reservoir unit, verify the water level, add if water is low.
CAUTION
KEEP HANDS AND FACE A WA Y FROM THE UNIT WHEN OPENING OR REMOVING THE SPATULA FROM THE UNIT. STEAM ESCAPING IS VERY HOT.
MANUAL CONTROL
• Turn unit on
Wait 20 - 30 minutes for the unit to reach its operating temperature before using.
Note: The Temperature Set Point is factory fi xed at 400°F (204°C) and is not adjustable.
• Place product in cooking chamber and hit the Steam Shot button to steam the product.
Steam Shot:
and will instantly produce steam. Water will only stop when the button is released. Flooding of the steam generator may occur if the Steam Shot button, or the SST is set to high. When this occurs wait for the
unit to work through the water before applying more water to the steam generator.
ELECTRONIC CONTROL
• Turn unit on
Current Temperature will Flash on LED, PRESS the TEMP button to see current temperature
TCT will FLASH until TSP (Temperature Set Point) is reached,
Alarm will sound 3-times when TSP is reached.
Pressing the Green Steam Shot Green Button will release water in to the steam generator
PROGRAMMING DEFINITIONS
TCT Total Cook Time SIT Shot Interval Time SST Steam Shot Time TSP Temp Set Point
Note: The Temperature Set Point is factory xed at 400°F (204°C) and is not adjustable.
• Place product in cooking chamber and choose one of the 4 pre-determined programmed settings, or hit the Steam Shot steam button to steam the product.
• When program timing is completed, an alarm will sound.
Steam Shot:
will instantly produce steam. Water will only stop when the button is released. Flooding of the steam generator may occur if the Steam Shot button, or the SST is set to high. When this occurs wait for the
unit to vaporize all of the water before applying more water to the steam generator.
Pressing the Green Steam Shot Button will release water in to the steam generator and
TIMER & STEAMER CONTROLLER OPERATION SPECIFICATIONS Startup:
1. The preset time will fl ash until the operating temperature is reached.
2. When the control reaches preset temperature, time display, "Heat On" indicator and
program indicator will stop fl ashing and the alarm will beep three times.
Temperature:
1. To view the actual steam generator temperature, press and hold "Temp Button."
6
Page 7
OPERATION continued
90 degrees
60 degrees
Cover
Stop
IL1366
To Program Time:
The program buttons factory pre-set are listed below. If changes are required follow
PROGRAMMING SPECIFICATIONS / RANGE
TCT Total Cook Time 0 to 99.59 minutes SIT Shot Interval Time .5sec to 10 minutes SST Steam Shot Time .1 sec to 5.minutes TSP Temp Set Point
these simple steps. Note, any changes to these settings are stored in the units memory until changed. Returning to the factory pre-sets
is not available automatically.
1. Press and hold "TEMP"
(actual temperature displays).
2. While holding "TEMP," press and hold any
program button for one second, to begin
TCT 20 sec 40 sec 1 min 1.30 min
SIT 20 sec 40 sec 40 sec 40 sec
SST .5 sec .5 sec .5 sec .5 sec
Program Button Factory Presets
1234
programming
3. TCT (Total Cook Time) will display, adjust time with the "3 or 4" buttons.
• Press the #1 button to move to between minutes and seconds.
• Press the #1 button to move to SIT.
4. SIT (Shot Interval Time) will display, adjust time with the "3 or 4" buttons.
• Press the #1 button to move to between minutes and seconds.
• Press the #1 button to move to SST.
5. SST (Steam Shot Time) will display, adjust time with the "3 or 4" buttons.
• Press the #1 button to move to seconds.
6. Press the "TEMP" button to save time settings and to exit programming mode for this program.
Your program will not be saved if this step is not done within 10 seconds.
7. Repeat process to program for additional programming
Hi-Limit Reset
A hi-limit reset monitors the temperature of the steam generator and will turn the power off to the unit to prevent it from overheating. If this occurs, the unit will automatically reset when it has had enough time to cool prior to returning to operation. If this occurs on a regular basis it may be a sign of a larger problem, call your service agent or Star Manufacturing at
1-800-807-9054.
TOP LOADING COVER STOP
SETTINGS
Top Loading Fast Steamer models
(FS1 & FS2) are designed with
adjustable cover stops located on
the back of the units. As shown
here you can adjust your unit's
top cover between an opening
of 60° - 90°.
7
Page 8
CLEANING
CAUTION
DO NOT USE CAUSTIC CLEANERS, USE A MILD DETERGENT T O WIPE DOWN EXTERIOR SURFACES, CLEAN WITH DAMP
CLOTH
Daily
1. Turn the unit OFF & unplug the unit from its power source before proceeding with any service or cleaning procedure.
2. Remove and clean the removable items listed on the maintenance components illustration for your specifi c model. Clean using warm water and mild detergent. DRY parts completely.
3. Wipe the exterior or the steamer with a damp cloth, then wipe dry . Note: drying all pieces
after cleaning will protect your fi nish from discoloration, any discoloration as a result from not drying the equipment is not covered under warranty
4. Reinstall the unit, beginning with the Steam Vent.
Monthly
The Star Fast Steamer generates instant steam by means of its open generator, however the mineral deposits in the water are left behind. A certain amount of deposits are needed for proper operation, but a build-up of calcium & mineral deposits may cause poor performance. It is important to properly maintain you steamer to ensure quality operation. Depending on your specifi c water conditions and possibly any water fi ltration systems, you may need to clean your steamer more or less frequently.
CAUTION
DO NOT IMMERSE OR LET THE UNIT STAND IN WATER. DO NOT HOSE DOWN THE UNIT. KEEP THE UNIT AWAY FROM RUNNING WATER.
DO NOT SPLASH THE CONTROL HOUSING CERTAIN WATER CONDITIONS MAY REQUIRE MORE FREQUENT CLEANING.
WARNING
BEFORE CLEANING MAKE SURE POWER IS TURNED OFF AND UNIT IS UNPLUGGED.
CAUTION
IF A CHEMICAL CLEANER / DELIMER IS USED, BE CERTAIN IS IT SAFE FOR CAST ALUMINUM. FOLLOW PROCEDURES, PRECAUTIONS PROVIDED WITH THA T SPECIFIC PRODUCT.
8
Page 9
Cleaning Steam Generator
1. Turn the unit OFF & unplug the unit from its power source.
2. Remove and clean the removable items listed on the maintenance components illustration for your specifi c model. Clean using warm water and mild detergent. DRY parts completely.
3. With the steam generator cool, use a wire brush or scrapper to loosen the mineral/ calcium deposits on the generator surface and steam ports. Remove the loose built-up particles from the surface and wipe area clean with damp cloth and reassemble the unit.
NOTE: A certain amount of calcium deposits are needed on the steam generator to ensure proper steaming characteristics. If during cleaning, the surface becomes free of all calcium/mineral deposits, add tap water to the generator surface and allow it to boil off. In soft water conditions, a small amount of lime will season it. (Seasoning Mixture, .75 oz. baking soda, .75 oz. lime, 1 quart water), use enough to cover bottom of the steam generator, turn unit on and allow to evaporate.
Excessive Mineral Build-up
4. Use a delimer solution, which is safe for cast aluminum, on the steam generator surface. Follow the instruction provide with the delimer solution.
5. Use a dry towel or sponge to remove the delimer solution, then rinse with clean water.
6. Install the diffuser, generator cover secure with the wing nut as shown here.
6. Plug the steamer power cord into the power supply, and turn unit on.
7. Allow unit to reach operating temperature.
Steam Generator
Steam Ports
Water Inlet
IL1359
Above: Inspect these area making sure they are clean of deposits.
Below: Reinstall these parts before foperating the steam feature during the cleaning procedure.
Wing Nut Generator
Cover
Diffuser
IL1377
CAUTION
KEEP HANDS AND F ACE A W A Y FROM THE UNIT WHEN OPERA TING THE UNIT. STEAM ESCAPING IS VERY HOT.
8. Push the Green "Steam Shot" button several times to operate the steamer.
This removes any delimer solution from the generator surface.
9. Turn unit off, reinstall all remaining parts and return unit to operation.
9
Page 10
CLEANING FRONT LOADING STEAMER COMPONENTS ILLUSTRATION
Top Cover
Wing Nut
Generator Cover
Steam Generator
Food Compartment
Liner
Steam Vent
Diffuser
Steam Ports
IL1352
Rack
Spatula
Drip Pan
Typical Front Loading Steamer Shown
10
Page 11
OPERATION TROUBLESHOOTING
DIAGNOSTICS FOR ELECTRONIC CONTROL STEAMERS
Shorted Temperature Probe
Open-Circuit Temperature Probe
No Heat/No Steam
Relay Malfunction
Heat / No Steam Temperature T o Cool
Less than 50 Ohms of resistance, if
a temperature probe is detected, the
output power will be shut-off to all relays.
if a temperature probe is detected, the
output power will be shut-off to all relays.
If relay malfunction is detected when the
temperature is below 150°F (66°C) for 30 minutes or reaches 500°F (260°C).
The output power will be shut-off to both
relays unit the error no longer occurs.
Probe Temperature is 200°F (93°C) less
than the programmed set point.
Press the “TEMP” switch,
the LED will display
Press the “TEMP” switch,
the LED will display
The display will blink
Program & Heat Indicator
Light will Flash.
If unit still does not operate contact the factory or one of its representatives or a local service company for service or required maintenance.
“PrOB”
“PrOB”
“rELY”
11
Page 12
Visit our Website at: www.star-mfg.com Email: service@star-mfg.com
This unit has been tested for proper operation before leaving our plant to insure delivery of your unit in perfect condition. However, there are instances in which the unit may be damaged in transit. In the event you discover any type of damage to your product upon receipt, you must immediately contact the transportation company who delivered the item to you and initiate your claim with same. If this procedure is not followed, it may affect the warranty status of the unit.
All workmanship and material in Star products have a one (1) year limited warranty on parts & labor in the United States and Canada. Such warranty is limited to the original purchaser only and shall be effective from the date the equipment is placed in service. Star's obligation under this warranty is limited to the repair of defects without charge, by the factory authorized service agency or one of its sub-agencies. Models that are considered portable (see below) should be taken to the closest Star service agency, transportation prepaid.
THOROUGHLY INSPECT YOUR UNIT ON ARRIVAL
LIMITED EQUIPMENT WARRANTY
> Star will not assume any responsibility for loss of revenue. > On all shipments outside the United States and Canada, see International Warranty. * The warranty period for the JetStar six (6) ounce & Super JetStar eight (8) ounce series popcorn machines is two (2) years. * The warranty period for the Chrome-Max Griddles is ¿ ve (5) years on the griddle surface. See detailed warranty provided with unit. * The warranty period for TeÀ on/Dura-Tec coatings is one year under normal use and reasonable care. This warranty does not apply if damage occurs to
TeÀ on/Dura-Tec coatings from improper cleaning, maintenance, use of metallic utensils, or abrasive cleaners, abrasive pads, product identi¿ ers and point-of-sale attachments, or any other non-food object tha comes in continuous contact with the roller coating. This warranty does not apply to the “non-stick” properties of such materials.
> This warranty does not apply to "Special Products" but to regular catalog items only. Star's warranty on "Special Products" is six (6) months on parts
and ninety (90) days on labor.
> This warranty does not apply to any item that is disassembled or tampered with for any purpose other than repair by a Star Authorized Service Center or
the Service Center's sub-agency.
> This warranty does not apply if damage occurs from improper installation, misuse, wrong voltage, wrong gas or operated contrary to the Installation and
Operating instructions.
> This warranty is not valid on Conveyor Ovens unless a "start-up/check-out" has been performed by a Factory Authorized Technician.
Parts that are sold to repair out of warranty equipment are warranted for ninety (90) days. The part only is warranted. Labor to replace the part is chargeable to the customer.
1. Travel time and mileage rendered beyond the 50 mile radius limit
2. Mileage and travel time on portable equipment (see below)
3. Labor to replace such items that can be replaced easily during a daily cleaning routine, ie; removable kettles on fryers, knobs, grease drawers on griddles, etc.
4. Installation of equipment
5. Damages due to improper installation
6. Damages from abuse or misuse
7. Operated contrary to the Operating and Installation Instructions
8. Cleaning of equipment
9. Seasoning of griddle plates
Star will not honor service bills that include travel time and mileage charges for servicing any products considered "Portable" including items listed below. These products should be taken to the Service Agency for repair:
* The Model 510FD Fryer. * The Model 526TOA Toaster Oven. * The Model J4R, 4 oz. Popcorn Machine. * The Model 518CMA & 526CMA Cheese Melter. * The Model 12MC & 15MC & 18MCP Hot Food Merchandisers. * The Model 12NCPW & 15NCPW Nacho Chip/Popcorn Warmer. * All Hot Dog Equipment except Roller Grills & Drawer Bun Warmers. * All Nacho Cheese Warmers except Model 11WLA Series Nacho Cheese Warmer. * All Condiment Dispensers except the Model HPD & SPD Series Dispenser. * All Specialty Food Warmers except Model 130R, 11RW Series, and 11WSA Series. * All QCS/RCS Series Toasters except Model QCS3 & RCS3 Series.
SERVICES NOT COVERED BY WARRANTY
PARTS WARRANTY
10. Voltage conversions
11. Gas conversions
12. Pilot light adjustment
13. Miscellaneous adjustments
14. Thermostat calibration and by-pass adjustment
15. Resetting of circuit breakers or safety controls or reset buttons
16. Replacement of bulbs
17. Replacement of fuses
18. Repair of damage created during transit, delivery, & installation OR created by acts of God
PORTABLE EQUIPMENT
ALL: * Pop-Up Toasters * Butter Dispensers * Pretzel Merchandisers
(Model 16PD-A Only)
* Pastry Display Cabinets * Nacho Chip Merchandisers * Accessories of any kind * Sneeze Guards * Pizza Ovens
(Model PO12 Only)
* Heat Lamps * Pumps-Manual
The foregoing warranty is in lieu of any and all other warranties expressed or implied and constitutes the entire warranty.
FOR ASSISTANCE
Should you need any assistance regarding the Operation or Maintenance of any Star equipment; write, phone, fax or email our Service Department.
In all correspondence mention the Model number and the Serial number of your unit, and the voltage or type of gas you are using.
Part# 2M-4497-2 12/06 RMS
12
Page 13
PUSH BUTTON
SK2250 Rev. C 8/30/2007
RTD PROBE
HEATING
ELEMENT
TRANSFORMER
120V/10V
COM
N02
NC3
10
10
10
CONTROL PANEL
10
MOUNTING PLATE
6
5
E4
E3
E1
E2
E11
E12
CONTROL
POWER
ELECTRONIC
(BACK SIDE)
3
7
E7 E6 E5
SWITCH
3
7
HEATER RELAY
THERMOSTAT
HIGH LIMIT
2
3
1
1
2
2
8
B
2
1
1
9
B
Sheet 1 of 8
6
5
3
8
SOLENOID
RELAY
1
A
4
CONTROL BOX
MOUNTING PLATE
SOLENOID
120V
4
2
A
WHITE WIRE (TYP)
BLACK WIRE (TYP)
CORDSET
(SHOWN)
120V: NEMA 5-15P
(NOT SHOWN)
120VC: NEMA 5-20P
B
COMPLETE
FS1DT & FS2DT
WIRING DIAGRAM
13
Page 14
PUSH BUTTON
SK2250 Rev. C 8/30/2007
RTD PROBE
HEATING
ELEMENT
TRANSFORMER
120V/10V
COM
N02
NC3
10
10
10
CONTROL PANEL
10
MOUNTING PLATE
6
5
E4
E3
E1
E2
E11
E12
CONTROL
POWER
ELECTRONIC
(BACK SIDE)
3
7
E7 E6 E5
SWITCH
3
7
HEATER RELAY
120V PUMP
2
3
1
1
1
1
9
2
2
2
6
Sheet 2 of 8
5
B
8
B
3
1
8
CONTROL BOX
MOUNTING PLATE
PUMP
RELAY
2
2
PART OF PUMP
DIODE AND WIRE
HIGH LIMIT
THERMOSTAT
B
WHITE WIRE (TYP)
BLACK WIRE (TYP)
CORDSET
(SHOWN)
120V: NEMA 5-15P
(NOT SHOWN)
120VC: NEMA 5-20P
14
COMPLETE
FS1RT & FS2RT
WIRING DIAGRAM
Page 15
PUSH BUTTON
SK2250 Rev. C 8/30/2007
HEATING
ELEMENT
COM
N02
NC3
1
4
C
STEAM GENERATOR
THERMOSTAT
CONTROL PANEL
MOUNTING PLATE
POWER
SWITCH
2
1
1
BLACK WIRE (TYP)
2
B
WHITE WIRE (TYP)
CORDSET
(SHOWN)
120V: NEMA 5-15P
2
(SHOWN ON SIDE)
120V SOLENOID
2
4
(NOT SHOWN)
120VC: NEMA 5-20P
3
3
1
B
A
CONTROL BOX
MOUNTING PLATE
HIGH LIMIT
A
THERMOSTAT
C
WIRING DIAGRAM
Sheet 3 of 8
FS1D & FS2D
15
Page 16
PUSH BUTTON
SK2250 Rev. C 8/30/2007
HEATING
ELEMENT
COM
N02
NC3
1
CONTROL PANEL
MOUNTING PLATE
POWER
SWITCH
2
1
1
BLACK WIRE (TYP)
2
B
WHITE WIRE (TYP)
2
2
B
3
1
3
Sheet 4 of 8
CONTROL BOX
MOUNTING PLATE
STD MOUNTING BELOW THERMOSTAT
CORDSET
(SHOWN)
120V: NEMA 5-15P
(NOT SHOWN)
120VC: NEMA 5-20P
STEAM GENERATOR THERMOSTAT
STD MOUNTED ABOVE HIGH LIMIT
16
STEAM GENERATOER HIGH LIMIT THERMOSTAT
FS1R & FS2R
WIRING DIAGRAM
Page 17
RTD PROBE
HEATING
ELEMENT
SK2250 Rev. C 8/30/2007
10
CONTROL PANEL
10
MOUNTING PLATE
6
5
5
E4
E3
E1
E2
E11
E12
CONTROL
POWER
ELECTRONIC
(BACK SIDE)
PUSH BUTTON
3
7
E7 E6 E5
SWITCH
COM
N02
NC3
230V/10V
TRANSFORMER
10
10
3
7
HEATER RELAY
THERMOSTAT
HIGH LIMIT
2
3
1
1
1
2
2
2
5
6
STD
POSITION
SOLENOID
MOUNTING
(SHOWN ON
9
SIDE).
1
SOLENOID
B
Sheet 5 of 8
RELAY
A
5
8
B
6
3
8
4
4
CONTROL BOX
MOUNTING PLATE
SOLENOID
12 V
CORDSET
WHITE WIRE (TYP)
BLACK WIRE (TYP)
FOR 208/240V
A
FSFDT
WIRING DIAGRAM
NEMA 6-20P
17
Page 18
SK2250 Rev. C 8/30/2007
Sheet 6 of 8
WIRING DIAGRAM
FSFD
NEMA 6-20P
1
1
2
2
B
3
1
A
5
2
NC3
N02
COM
PUSH BUTTON
A
CORDSET FOR
208/240V
B
2
4
3
5
CONTROL BOX
MOUNTING PLATE
HIGH LIMIT
THERMOSTAT
STEAM GENERATOR
THERMOSTAT
HEATING
ELEMENT
POWER
SWITCH
CONTROL PANEL
MOUNTING PLATE
12 V SOLENOID
(SHOWN ON SIDE)
6
6
4
BLACK WIRE (TYP)
WHITE WIRE (TYP)
C
C
18
Page 19
HEATING
ELEMENT
C & D - 3/16" MALE
W/WHITE WIRE LEADS
SK2250 Rev. A 8/3/2007
TRANSFORMER
40 VA 230V/12V
DETAIL A
TRANSFORMER
PUSH BUTTON
INLINE FUSEHOLDER
COM
N02
NC3
W/4AMP FUSE
10
10
6
RTD PROBE
5
5
3
7
2
3
7
12V PUMP
HEATER RELAY
A & B - 1/4" MALE
W/BLACK WIRE LEADS
Sheet 7 of 8
3
E4
E3
E1
E2
E11
10
10
E12
1
E7 E6 E5
1
2
2
1
2
5
B
SEE
A
DETAIL
6
6
1
9
5
CONTROL PANEL
MOUNTING PLATE
CONTROL
POWER
ELECTRONIC
(BACK SIDE)
8
SWITCH
BLACK WIRE (TYP)
B
CORDSET
WHITE WIRE (TYP)
FOR 208/240V
NEMA 6-20P
HIGH LIMIT
THERMOSTAT
19
3
8
PUMP
RELAY
6
PART OF PUMP
DIODE AND WIRE
CONTROL BOX
MOUNTING PLATE
FSFRT
WIRING DIAGRAM
Page 20
PUSH BUTTON
C & D - 3/16" MALE
W/WHITE WIRE LEADS
SK2250 Rev. C 8/30/2007
HEATING
ELEMENT
DETAIL A
DIODE AND WIRE
PART OF PUMP
COM
N02
NC3
INLINE FUSEHOLDER
W/4AMP FUSE
TRANSFORMER
CONTROL PANEL
MOUNTING PLATE
POWER
SWITCH
2
1
1
BLACK WIRE (TYP)
2
B
208/240V
CORDSET FOR
WHITE WIRE (TYP)
1
2
NEMA 6-20P
2
A
SEE
DETAIL
B
3
1
B
3
A & B - 1/4" MALE
W/BLACK WIRE LEADS
Sheet 8 of 8
CONTROL BOX
MOUNTING PLATE
12 V PUMP
FSFR
STD MOUNTING BELOW THERMOSTAT
STEAM GENERATOR THERMOSTAT
STD MOUNTED ABOVE HIGH LIMIT
STEAM GENERATOER HIGH LIMIT THERMOSTAT
WIRING DIAGRAM
20
Page 21
Page 22
19
20
1
2
3
4 5
21
6
18
17
16
MODEL: FSF
Front Loading Steamer Main Body Assembly
8
9
10
11
12
15
STAR MANUFACTURING INTERNATIONAL, INC.
7
13
11
14
21
Rev. A 10/31/07SK2276
Page 23
PARTS LIST October 29, 2007, Rev A
FSFR, FSFD, FSFRT, FSFDT, Front Loading Fast Steamer Main Body
MODEL
Number
Key
Number
1 C9-Z10101 1 TOP FRONT LOADING 2 2C-Z10133 2 NUT, WING 10-24 SS FRONT LOADING 3 C9-Z10095 1 COVER, CASTING FRONT LOADING 4 C9-Z10096 1 DISPERSER FRONT LOADING 5 2C-08-07-0285 1 SCREW 10-24X3/4X3/8 TYPE 2 HEX DBL END STL FRONT LOADING 6 C9-Z10069 1 RACK, WIRE STEAMER FRONT LOADING 6 C9-FS0313 1 LINER ASSEMBLY FSF STEAMER FRONT LOADING 7 C9-FS0373 1 SPATULA ASSEMBLY FRONT LOADING 8 2B-Z10069 1 SPATULA WIRE ASSY FRONT LOADING 9 2C-Z11259 1 BOLT CARRIAGE 3/8-16X1" SS FRONT LOADING 10 2A-Z11257 1 SPATULA HANDLE TUBE FRONT LOADING 11 2A-Z11258 2 SPATULA ANGLED WASHER FRONT LOADING 12 C9-Z10103 1 SPATULA FRONT LOADING 13 C9-Z9990 1 SPATULA FRONT FRONT LOADING 14 2R-09-WB-0027 1 HANDLE-BLK 3/8-16 HD698 FRONT LOADING 15 C9-Z10105 1 DRIP TRAY FRONT LOADING 16 2C-Z6925 6 SCREW,#8 X.5 TEK HW SS FRONT LOADING 17 C9-Z11250 1 DRIP TRAY SUPPORT FSF FRONT LOADING 18 2A-Z9989 4 FOOT, 2" STEAMER FRONT LOADING 19 C9-FS0301 1 VENT ASSEMBLY FRONT LOADING 20 C9-FS0344 1 FSF CASTING ASSEMBLY 208V FRONT LOADING 208V 20 C9-FS0345 1 FSF CASTING ASSEMBLY 230V FRONT LOADING 230/240V 21 2C-3033 12 SCREW-MACH 8-32X3/4 NPST FRONT LOADING
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
22
Page 24
23
21
2
1
3
4
5
6
7
8
9
18
21
20
16
17
16
19
15
22
10
11
12
13
14
MODEL FS1 & FS2
Main Body Assembly
STAR MANUFACTURING INTERNATIONAL, INC.
Rev. - 7/31/07SK2281
23
Page 25
PARTS LIST October 29, 2007, Rev A
MODEL
FS1R, FS1D, FS1RT, FS1DT, FS2R, FS2D, FS2RT, FS2DT Top Loading Fast Steamer Main Body
Number
Key
Number
1 2C-4063 AR SCREW 10-24X1/2 SS THP FS1 & FS2 2 C9-FS0364 1 COVER SKIN ASSY FS1 C9-FS0365 1 COVER SKIN ASSY FS2 3 2C-Z9982 1 SCREW 3/8-16X1 PHFHMS SS FS1 & FS2 4 2A-Z9955 1 HANDLE MOUNTING BLOCK FS1 & FS2 5 2R-09-WB-0027 1 HANDLE-BLK 3/8-16X1 PHFHMS SS FS1 & FS2 6 2C-9042 3 SCREW 10-24X.75 FH SS FS1 & FS2 7 C9-FS0315 1 INSIDE COVER INSERT FS2 FS2 C9-FS0316 1 INSIDE COVER INSERT FS1 FS1 8 2I-Z10033 1 FS2 COVER GASKET W/CLIPS FS2 2I-Z10034 1 FS1 COVER GASKET W/CLIPS FS1 9 2B-Z10067 1 BOTTOM GRATE FOR 1/2 PAN FS1 2B-Z5847 1 BUN RACK (SMALL) FS2 10 2D-Z10054 1 1/2 PAN 2.5DP PERF SIDES - FS1 2D-Z10241 1 PAN, 2/3 PERFORATED FS2 11 2C-Z4251 2 SCREW 8-32X3/8 RHP SS FS1 & FS2 12 C9-Z9987 1 COVER DRIP CATCH FS1/2 FS1 & FS2 13 C9-Z10488 1 PROBE HOLDER FS1/FS2 E/C - FS1RT, FS2RT, FS1DT, FS2DT 14 2C-1487 1 SCREW 6-32X1/4 RHP STL NP FS1RT, FS2RT, FS1DT, FS2DT 15 C9-Z10174 1 BOTTOM FS2 FS2 C9-Z10175 1 BOTTOM FS1 FS1 16 2C-Z6925 14 SCREW #8 X 1/2 HEX WB SS FS1 & FS2 2C-Z6925 10 SCREW,#8 X.5 TEK HW SS FS2 17 2A-Z3828 4 1" SOLID LEG FS1 & FS2 18 C9-Z10482 1 ELEMENT INSULATION FS1 FS1D, FS1DT, FS1R, FS1RT C9-Z10483 1 ELEMENT INSULATION FS2 FS2D, FS2DT, FS2R, FS2RT 19 2C-Z2893 4 NUT 10-24 HEX STL ZP 9/16 WASHER FS1 & FS2 20 C9-Z10153 2 STEAM GENERATOR SUPPORT FS1 FS2 STEAMER FS1 & FS2 21 C9-Z10336 2 ELEMENT RETAINER FS1 FS1 C9-Z10337 2 ELEMENT RETAINER FS2 FS2 22 2A-Z6604 4 SPACER, INSULATION PLATE FS1 & FS2 23 2N-Z9983 1 ELEMENT FS1 120V 1800W FS1-120V 2N-Z9984 1 ELEMENT FS2 120V 1800W FS2-120V
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
24
Page 26
32
37
33
32
31
28
36
Top Loading
12
11
13
33
Front Loading
14
16
15
28
1
2
3
28
30
7 8
29
4
28
5
6
1
1
9
10
Electronic Controls
12
11
13
Manual Controls
MODEL Fast Steamer
Control Box Assemblies Direct Connect Water Supply
22
24
16
23
STAR MANUFACTURING INTERNATIONAL, INC.
Rev. - 7/31/07SK2277
25
Page 27
17
36
Top Loading
33
32
31
32
Front Loading
34
35
38
33
2
21
20
28
30
28
3
7
29
27
1
26
8
3
12
13
11
Electronic Controls
14
16
15
11
12
13
Manual Controls
1
19
5
6
24
23
16
10
22
MODEL Fast Steamer
Control Box Assemblies Reservoir Water Supply
STAR MANUFACTURING INTERNATIONAL, INC.
Rev. - 7/31/07SK2277
26
Page 28
PARTS LIST October 29, 2007, Rev A
FSFR, FSFD, FSFRT, FSFDT, FS1R, FS1D, FS1RT, FS1DT, FS2R, FS2D, FS2RT, FS2DT
MODEL
Top & Front Loading Fast Steamer Control Box Assemblies
Number
Key
Number
1 2C-Z4063 AR SCREW 10-24X1/2 SS THP 18-8 OR 300 SERIES 2 C9-FS0300 1 CB COVER ASSY DC DIRECT CONNECT FS1DT-120V,FS2DT-120V, FSFDT-208/240V, FS1D-120V, FS2D-120V, FSFD-208/240V C9-FS0305 1 CNTR BOX COVER ASSY STMR W/RES FS1RT-120V, FS2RT-120V, FSFRT-208/240V, FS1R-120V, FS2R-120V, FSFR-208/240V 3 2E-Z10158 2 RELAY, DPST-NO SEALED FS1DT-120V, FS2DT-120V, FSFDT-208/240V, FS1RT-120V, FS2RT-120V, FSFRT-208/240V 4 2V-Z9981 1 SOLENOID VALVE 120V STMR FS1DT-120V, FS2DT-120V, FS1D-120V, FS2D-120V 2V-Z9988 1 SOLENOID VALVE 12V FSFD-208/240V FSFDT-208/240V 5 2T-Z10248 1 THERMOSTAT, 122F-483F FS1D, FS2D, FSFD, FS1R, FS2R, FSFR 2T-Z10839 1 HL THERMOSTAT CAP-570 FSFD-208V 6 2T-Z10839 1 HL THERMOSTAT CAP-570 ALL 7 2E-05-07-0350 1 TRANSFORMER 230V/10V 6VA FSFD-208/240V, FSFDT-208/240V 2E-05-07-0351 1 TRANSFORMER 115/10V 6VA FS1RT-120V, FS2RT-120V, FS1DT-120V, FS2DT-120V 2E-Z10170 1 TRANSFORMER, 40V 12V 115/230 FSFRT-208/240V, FSFR-208/240V 8 C9-FS0317 1 CB BTM ASSY FSF DC EC FSFDT-208/240V C9-FS0335 1 CB BTM ASSY FS1/2 DC MAN FS1D-120V, FS2D-120V C9-FS0339 1 CB BTM ASSY FS1/2 DC EC FS1DT, FS2DT C9-FS0341 1 CB BTM ASSY FS1/2 R EC FS1RT, FS2RT C9-FS0343 1 CB BTM ASSY FS1/2 R MAN FS1R, FS2R C9-FS0351 1 CB BTM ASSY FSF DC MAN FSFD-208/240V C9-FS0352 1 CB BTM ASSY FSF R EC FSFRT-208/240V C9-FS0360 1 CB BTM ASSY R MAN FSFR-208/240V 9 2K-Z10080 1 Q-D FEMALE/3/8 HOSE PANEL FS1DT-120V,FS2DT-120V, FSFDT-208/240V, FS1D-120V, FS2D-120V, FSFD-208/240V 10 C9-FS0311 1 CNTR BOX BACK ASSY FS1RT-120V, FS2RT-120V, FSFRT-208/240V, FS1R-120V, FS2R-120V, FSFR-208/240V C9-FS0314 1 CB BACK PNL ASSY DC FS1DT-120V,FS2DT-120V, FSFDT-208/240V, FS1D-120V, FS2D-120V, FSFD-208/240V 11 2E-Z1858 1 SWITCH-LIGHTED ALL 12 2M-Z10244 1 CNTR PANEL LABEL E/C FS1DT-120V, FS2DT-120V, FSFDT-208/240V, FS1RT-120V, FS2RT-120V, FSFRT-208/240V 12 2M-Z10245 1 CNTR PANEL LABEL MANUAL FS1D-120V, FS2D-120V, FSFD-208/240V, FS1R-120V, FS2R-120V, FSFR-208/240V 13 C9-FS0320 1 CNTR PANEL ASSY E/C FS1DT-120V, FS2DT-120V, FSFDT-208/240V, FS1RT-120V, FS2RT-120V, FSFRT-208/240V C9-Z10484 1 CNTR PANEL ASSY M/C FS1D-120V, FS2D-120V, FSFD-208/240V, FS1R-120V, FS2R-120V, FSFR-208/240V 14 2K-Z1971 4 SPACER .257X.75X.25 NYLON FS1DT-120V, FS2DT-120V, FSFDT-208/240V, FS1RT-120V, FS2RT-120V, FSFRT-208/240V 15 2J-Z9794 1 STMR CNTR BOARD FS1DT-120V, FS2DT-120V, FSFDT-208/240V, FS1RT-120V, FS2RT-120V, FSFRT-208/240V 16 2E-Z9991 1 SNAP PUSHBUTTON ASSY ALL 17 C9-Z10486 1 TANK LID FSF FS1/2 STMR FS1RT-120V, FS2RT-120V, FSFRT-208/240V, FS1R-120V, FS2R-120V, FSFR-208/240V 19 A3-35219 1 CAP & CHAIN FS1RT-120V, FS2RT-120V, FSFRT-208/240V, FS1R-120V, FS2R-120V, FSFR-208/240V 20 2C-Z2893 1 NUT 10-24 HEX STL ZP 9/16 WASHER FSFD-208/240V, FSFDT-208/240V, FSFR-208/240V, FSFRT-208/240V 21 C9-Z10481 1 PROBE/BULD HOLD DOWN BRKT FSFD-208/240V, FSFDT-208/240V, FSFR-208/240V, FSFRT-208/240V
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
2
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
27
Page 29
PARTS LIST October 29, 2007, Rev A
FSFR, FSFD, FSFRT, FSFDT, FS1R, FS1D, FS1RT, FS1DT, FS2R, FS2D, FS2RT, FS2DT
MODEL
Top & Front Loading Fast Steamer Control Box Assemblies
Number
Key
Number
22 A5-RG2036 1 CORD SET 120V W/TERMINALS, 120V C9-FS0357 1 CORD SET 120VCSA 120VC C9-FS0362 1 CORD SET 12/3 6-20 6' , 208/240V 208/240V 23 2K-Y3240 1 BUSHING HEYCO SR 17-2 FSFD-120V, 2K-Y6764 1 BUSHING - STRAIN RELIEF FSFD-208V 24 C9-FS0359 1 CORD SET 14/3 5-20P 6FT 120V-CUL C9-Z10457 1 CORDSET MTG PLATE .88X.77 FS1D-120V, FS1DT-120V, FS1R-120V, FS1RT-120V, FS2D-120V, FS2DT-120V, FS2R-120V, FS2RT-120V C9-Z10458 1 CORDSET MTG PLATE .88X.844 FSFD-208240V, FSFDT-208/240V, FSFR-208/240V, FSFRT-208/240V 26 C9-Z10220 2 PUMP MOUNTING STRAP FS1RT-120V, FS2RT-120V, FSFRT-208/240V, FS1R-120V, FS2R-120V, FSFR-208/240V 27 2U-Z10070 1 WATER PUMP, STMR 12V FSFRT-208/240V, FSFR-208/240V 2U-Z9980 1 WATER PUMP, STMR 120V FS1RT-120V, FS2RT-120V, FS1R-120V, FS2R-120V 28 2C-Z10240 4 CLAMP, HOSE 7/16-25/32 FS1D-120V, FS1DT-120V, FS1R-120V, FS1RT-120V, FS2D-120V, FS2DT-120V, FS2R-120V, FS2RT-120V 2C-Z10240 8 CLAMP, HOSE 7/16-25/32 FSFD-208/240V, FSFDT-208/240V, FSFR-208/240V, FSFRT-208/240V 29 C9-Z10237 1 PUMP INLET HOSE FS1R, FS1RT, FS2R, FS2RT, FSFR, FSFRT C9-Z10246 1 SOLENOID INLET HOSE FS1DT­ 30 C9-Z10238 1 FSF PUMP OUTLET HOSE FSF STMR FSFRT-208/240V, FSFR-208/240V C9-Z10247 1 FS1/FS2 OUTLET HOSE FS1/FS2 C9-Z10456 1 FSF SOK OUT / TEE OUT HOSE FSFD, FSFDT 31 2K-Z9986 1 UNION TEE, 3/8 SLIP-ON DBL HSE BARB-STMR FSFD-208V 32 C9-Z10456 2 FSF SOL OUT/TEE OUT HOSE FSF STMR FSFD-208/240V, FSFDT-208/240V C9-Z10456 1 FSF SOL OUT/TEE OUT HOSE FSF STMR FSFR-208/240V, FSFRT-208/240V 33 2A-Z9972 2 NIPPLE, PTFE 5.5" FSFD, FSFDT, FSFR, FSFRT 34 2E-Z10855 1 FUSE 4AMP .25X1.25 FSFRT-208/240V, FSFR-208/240V 35 C9-FS0308 1 FUSEHOLDER WIRE ASSY F/F FSFRT-208/240V C9-FS0330 1 FUSEHOLDER WIRE ASSY M/F FSFR-208/240V 36 2K-Z9978 1 HALF NIPPLE 1/8X2.5 FS1D, FS1DT, FS1R, FS1RT, FS2D, FS2DT, FS2R, FS2RT 37 2V-Z10448 1 STMR WATER SUPPLY HOSE FS1DT-120V, FS2DT-120V, FSFDT-208/240V, FS1D-120V, FS2D-120V, FSFD-208/240V 38 2E-Z3278 1 RTD PROBE - 48" LONG WIRE FS1DT, FS2DT, FS1RT, FS2RT, FSFDT, FSFRT
Part
Number
Per
Unit
Description and Model Designation
2
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
2
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
28
Page 30
2
3
1
6
4
5
7
8
9
MODEL FS1 & FS2
Hinge Bracket Assembly
2
STAR MANUFACTURING INTERNATIONAL, INC.
Rev. - 8/28/07SK2315
29
Page 31
PARTS LIST October 29, 2007, Rev A
FS1R, FS1D, FS1RT, FS1DT, FS2R, FS2D, FS2RT, FS2DT
MODEL
Top Loading Fast Steamer Hinge Assemblies
Number
Key
Number
1 2A-Z10454 1 CENTER HINGE PIN FS1 FS1 2A-Z10677 1 CENTER HINGE PIN FS2 FS2 2 2A-Z10214 2 PIN, SPRING STEAMER ALL FS1 & FS2 3 C9-Z10156 2 HINGE/COVER BRACKET ALL FS1 & FS2 4 2C-Z10215 8 COTTER PIN 18-8 5/16 .059 ALL FS1 & FS2 5 2A-Z9992 2 HINGE PIN, OUTSIDE ALL FS1 & FS2 6 2C-Z4063 AR SCREW 10-24X1/2 SS THP 7 2P-Z10217 2 FS1 FS2 HINGE SPRING ALL FS1 & FS2 8 2A-Z10093 8 SCREW SHOULDER 8-32X3/16 ALL FS1 & FS2 9 C9-Z10452 2 COVER STOP FS1 FS2 ALL FS1 & FS2
Part
Number
Per
Unit
Description and Model Designation
1
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE
1
INCLUDE MODEL AND SERIAL NUMBER OF
Some items are included for illustrative purposes only and in certain instances may not be available.
Star Manufacturing International, Inc.
30
Page 32
STAR MANUFACTURING
10 Sunnen Drive, St. Louis, MO 63143 U.S.A.
(800) 807-9054 (314) 781-2777
Parts & Service (800) 807-9054
www.star-mfg.com
Loading...