Star
Manufacturing
International Inc.
10 Sunnen Drive
St. Louis, MO 63143
Installation
and
Operating
Instructions
Phone: (314) 781-2777
Fax: (314) 781-2714
2M-Z8343 Rev. B 6/03/2008
DOUBLE CONVEYOR
TOASTER
MODEL
DT14SH
2
These symbols are intended to alert the user to the presence of
important operating and maintenance instructions in the manual
accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves the
manufacturer of all liability.
Star reserves the right to change specifi cations and product design without
notice. Such revisions do not entitle the buyer to corresponding changes,
improvements, additions or replacements for previously purchased
equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specifi cations contained in this sheet are subject to change
without notice. While Star Manufacturing exercises good faith efforts to provide
information that is accurate, we are not responsible for errors or omissions
in information provided or conclusions reached as a result of using the
specifi cations. By using the information provided, the user assumes all risks in
connection with such use.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model
number, serial number, voltage and purchase date in the area below and have it ready when you call to
ensure faster service.
SAFETY SYMBOL
Model No.
Serial No.
Voltage
Purchase Date
Business 8:00 am to 4:30 p.m. Central Standard Time
Hours:
Telephone: (800) 807-9054 Local (314) 781-2777
Fax: (800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com
Warranty@star-mfg.com
Website: www.star-mfg.com
The Star Service Help Desk
Authorized Service Agent
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com
E-mail Service@star-mfg.com
Telephone: (800) 807-9054 Local (314) 781-2777
Mailing Address: Star Manufacturing International Inc.
10 Sunnen Drive
St. Louis, MO 63143
U.S.A
2
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for
use directly by the general public in food service locations. For equipment to be used by the
general public, please contact the factory.
INSTALLATION
This toaster is equipped for the voltage indicated on the nameplates mounted on the side
panel. It will operate on alternating current only.
CAUTION
DO NOT CONNECT TO DIRECT CURRENT (DC)
Installation of the toaster should conform to the National Electric Code and all local electric
codes and ordinances and the local electric company rules and regulations.
For your protection we recommend that a qualied electrician install the toaster. The electrician should be familiar with electrical installations and electrical codes. Proper connections
and power supply are essential for efcient performance.
External wiring to the unit should be in conduit or and approved type of exible calbe. Wir-
ing must be #6 AWG minimum with copper conductors. Insulation must be suitable for at
least 90°C (194°F). The supply circuit should be properly fused and equipped with a means
of disconnection as required by the local elecctrical code. THE BODY OF THE TOASTER
SHOULD BE GROUNDED (DO NOT GROUND TO A GAS SUPPLY LINE). The toaster is
wired for operation on single-phase power only. A terminal block is provided for supply con-
nection inside the left side panel. Level the unit using the adjustable feet provided.
CAUTION
DO NOT INSTALL THE TOASTER CLOSER THAN 3 INCHES TO REAR AND
SIDE WALLS. DO NOT INSTALL WITHOUT LEGS
GENERAL OPERATING PROCEDURES
The toaster is supplied with removable discharge chute that can be installed for either front
or rear operation. A removable loading chute is also provided for each conveyor. The top
conveyor opening is equipped with an adjustable front heat shutter to minimize heat loss.
To adjust the shutter, loosen the screw on the front of the top cover and slide the shutter to
the desired position. Tighten the screw to lock the shutter in place. Crumb trays are located
below each conveyor.
CAUTION
DO NOT OPERATE THE TOASTER WITH THE CRUMB TRAYS REMOVED
Operation without the crumb trays will cause the unit to overheat and shut down. The top
toasting chamber has heating elements above and below the conveyor to
allow two-sided toasting. The lower chamber has heating elements above the conveyor for
one-sideed toasting. Each chamber has an individual conveyor speed control for toasting
a wide range of products and a power switch that will completely shut off each chamber or
provide 1/4 input during idel times. A fan is provided in the control box to reduce the temperature of electrical compents and to provide convection toasting. This fan will come on
when the toasting chamber is at operating temperature and remain on until the power switch
is turned to the off position and the toasting chamber has cooled. The cooling fan stays on
after the power switch is turned off until the toasting chamber has cooled. Do not block the
air intake on the bottom sideof the control box. This area must be kept clean and clear of
obstructions. Blockage of the cooling fan will cause the unit to overheat and shut down.
3
CLEANING PROCEDURES
Take care when cleaning to prevent burns and bodly injury. Clean the unit daily to prevent
the buildup of food particles, grease and oils, which will carbonize and become difcult to
remove.
1) Turn the power switch to the off position and allow the unit to cool.
2) Turn the power switch to standby and the speed control to the fastest position.
For light soil removal wipe the conveyor with a damp cloth. For heavy soil removal wipe
the conveyor with a dry light abrasive pad.
3) Turn the power switch to the off position and allow the unit to cool.
4) A wire brush can be used to clean the surface of the conveyor extensions.
5) The crumb trays, discharge chute and loading trays can be removed and washed in a
dishwasher or sink using a mild non-abrasive cleaner and a damp cloth.
CAUTION
DO NOT OPERATE THE TOASTER
WITH THE CRUMB TRAYS
REMOVED
6) Using a damp cloth and a mild
detergent wipe the exterior of the unit.
Stubborn soils can be removed using
a dry light abrasive pad.
To avoid damaging the nish, only rub
in the direction of the grain.
7) Wipe the air intake grill located on the
bottom of the control box with a damp
cloth to remove any accumulation
of foreign matter
regularly to prevent a restriction of air
movement.
, this must be done
4