Star Manufacturing DT14SH, DT 14SH Installation Manual

®
Star Manufacturing International Inc.
10 Sunnen Drive St. Louis, MO 63143
Installation
and
Instructions
Phone: (314) 781-2777 Fax: (314) 781-2714
2M-Z8343 Rev. B 6/03/2008
DOUBLE CONVEYOR
TOASTER
MODEL
DT14SH
2
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change specifi cations and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the specifi cations contained in this sheet are subject to change without notice. While Star Manufacturing exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifi cations. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to
ensure faster service.
SAFETY SYMBOL
Model No.
Serial No.
Voltage
Purchase Date
Business 8:00 am to 4:30 p.m. Central Standard Time Hours:
Telephone: (800) 807-9054 Local (314) 781-2777 Fax: (800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com Warranty@star-mfg.com
Website: www.star-mfg.com
The Star Service Help Desk
Authorized Service Agent
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com E-mail Service@star-mfg.com Telephone: (800) 807-9054 Local (314) 781-2777
Mailing Address: Star Manufacturing International Inc.
10 Sunnen Drive St. Louis, MO 63143 U.S.A
2
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and ex­perienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. For equipment to be used by the general public, please contact the factory.
INSTALLATION
This toaster is equipped for the voltage indicated on the nameplates mounted on the side panel. It will operate on alternating current only.
CAUTION
DO NOT CONNECT TO DIRECT CURRENT (DC)
Installation of the toaster should conform to the National Electric Code and all local electric codes and ordinances and the local electric company rules and regulations. For your protection we recommend that a qualied electrician install the toaster. The electri­cian should be familiar with electrical installations and electrical codes. Proper connections
and power supply are essential for efcient performance.
External wiring to the unit should be in conduit or and approved type of exible calbe. Wir-
ing must be #6 AWG minimum with copper conductors. Insulation must be suitable for at
least 90°C (194°F). The supply circuit should be properly fused and equipped with a means of disconnection as required by the local elecctrical code. THE BODY OF THE TOASTER SHOULD BE GROUNDED (DO NOT GROUND TO A GAS SUPPLY LINE). The toaster is wired for operation on single-phase power only. A terminal block is provided for supply con-
nection inside the left side panel. Level the unit using the adjustable feet provided.
CAUTION
DO NOT INSTALL THE TOASTER CLOSER THAN 3 INCHES TO REAR AND SIDE WALLS. DO NOT INSTALL WITHOUT LEGS
GENERAL OPERATING PROCEDURES
The toaster is supplied with removable discharge chute that can be installed for either front or rear operation. A removable loading chute is also provided for each conveyor. The top conveyor opening is equipped with an adjustable front heat shutter to minimize heat loss. To adjust the shutter, loosen the screw on the front of the top cover and slide the shutter to the desired position. Tighten the screw to lock the shutter in place. Crumb trays are located
below each conveyor.
CAUTION
DO NOT OPERATE THE TOASTER WITH THE CRUMB TRAYS REMOVED
Operation without the crumb trays will cause the unit to overheat and shut down. The top toasting chamber has heating elements above and below the conveyor to allow two-sided toasting. The lower chamber has heating elements above the conveyor for one-sideed toasting. Each chamber has an individual conveyor speed control for toasting a wide range of products and a power switch that will completely shut off each chamber or provide 1/4 input during idel times. A fan is provided in the control box to reduce the tem­perature of electrical compents and to provide convection toasting. This fan will come on when the toasting chamber is at operating temperature and remain on until the power switch is turned to the off position and the toasting chamber has cooled. The cooling fan stays on after the power switch is turned off until the toasting chamber has cooled. Do not block the air intake on the bottom sideof the control box. This area must be kept clean and clear of
obstructions. Blockage of the cooling fan will cause the unit to overheat and shut down.
3
CLEANING PROCEDURES
CLEAN
OPERATE
IL1513
Take care when cleaning to prevent burns and bodly injury. Clean the unit daily to prevent
the buildup of food particles, grease and oils, which will carbonize and become difcult to
remove.
1) Turn the power switch to the off position and allow the unit to cool.
2) Turn the power switch to standby and the speed control to the fastest position. For light soil removal wipe the conveyor with a damp cloth. For heavy soil removal wipe the conveyor with a dry light abrasive pad.
3) Turn the power switch to the off position and allow the unit to cool.
4) A wire brush can be used to clean the surface of the conveyor extensions.
5) The crumb trays, discharge chute and loading trays can be removed and washed in a dishwasher or sink using a mild non-abrasive cleaner and a damp cloth.
CAUTION
DO NOT OPERATE THE TOASTER WITH THE CRUMB TRAYS REMOVED
6) Using a damp cloth and a mild detergent wipe the exterior of the unit. Stubborn soils can be removed using a dry light abrasive pad.
To avoid damaging the nish, only rub
in the direction of the grain.
7) Wipe the air intake grill located on the
bottom of the control box with a damp cloth to remove any accumulation of foreign matter regularly to prevent a restriction of air
movement.
, this must be done