Star Manufacturing CSD-2NHC, CSD-2NH Parts List

DOUBLE PERISTALTIC
CHEESE DISPENSER
MODEL
CSD-2-H SERIES
Installation and
Operation
Instructions
CSD-2-H
1
SAFETY SYMBOL
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change specifi cations and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the specifi cations contained in this sheet are subject to change without notice. While Star Manufacturing exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifi cations. By using the information provided, the user assumes all risks in connection with such use.
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to
ensure a faster service.
Model No.
Serial No.
Voltage
Purchase Date
Authorized Service Agent
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com E-mail Service@star-mfg.com Telephone: (800) 807-9054 Local (314) 781-2777
The Star Service Help Desk
Business 8:00 am to 4:30 p.m. Central Standard Time Hours:
Telephone: (800) 807-9054 Local (314) 781-2777
Fax: (800) 396-2677 Local (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com Warranty@star-mfg.com
Website: www.star-mfg.com
Mailing Address: Star Manufacturing International Inc.
10 Sunnen Drive St. Louis, MO 63143 U.S.A
2
2
SPECIFICATIONS
Double Peristaltic Cheese Dispenser, Model CSD-2-H
Capacity: Four 6 pound bags (Four 2.7kg Bags) Electrical: 120V; 1050 Watts; 60 Cycle; single phase - or - 230V; 1050 Watts; 50 Cycle; single phase Dimensions: 18 1/4" W x 18 1/4" D x 25 3/8" H (46.3 W x 46.3 D x 64.4 H cm) Net Weight: 45 lbs. (20.4kg)
CAUTION
This equipment is designed and sold for commercial use only by personnel trained and
experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations.
Before using your new equipment, read and understand all the instructions & labels
associated with the unit prior to putting it into operation. Make sure all people associated with its use understand the units operation & safety before they use the unit.
All shipping containers should be checked for freight damage both visible and concealed.
This unit has been tested and carefully packaged to insure delivery of your unit in perfect condition. If equipment is received in damaged condition, either apparent or concealed, a claim must be made with the delivering carrier.
Concealed damage or loss - if damage or loss is not apparent until after equipment is
unpacked, a request for inspection of concealed damage must be made with carrier within 15 days. Be certain to retain all contents plus external and internal packaging materials for
inspection. The carrier will make an inspection and will supply necessary claim forms.
-IMPORTANT­Read this manual completely before attempting installation.
INSTALLATION
This cheese dispenser is equipped for the voltage and wattage indicated on the nameplate mounted on the back of the unit, and is designed for use on alternating current (AC) only.
NOTE: The cheese dispenser should not be installed without the four-inch (10cm) legs provided with the machine. The legs screw into the nuts on the bottom of the dispenser.
WARNING
DO NOT CONNECT TO DIRECT CURRENT (DC).
GENERAL OPERATING INSTRUCTIONS
This cheese dispenser is designed to be used with a 9” x 14” (22.8 x 35.5cm) poly bag with a 1 inch (2.5cm) outlet fi tment. The peristaltic pump is designed to be used with 1/4 inch id. (.6cm) to 1/2 inch id. (1.3cm) tubing with 1/16 inch (.16cm) wall thickness.
The dispenser is designed with a preset non-adjustable thermostat. It is designed to maintain a product temperature of between 140°F to 160°F.
3
Loading Product:
1. Turn dispenser OFF.
2. Unhook the tension spring from the catch.
3. Slide the pump block away from the pump head.
4. Insert the new bag into tray and route the tube around the rollers. (NOTE: Make sure hose is not twisted)
5. Place the end of the hose in the slot of the bottom bracket.
6. Slide the pump block towards the pump head.
7. Hook the tension spring onto the catch.
8. Install the tube cover back onto the dispenser, extending the tube through the cover. Leave 1/2" of the tube below the cover.
9. Dispense a small amount of product to insure the tube is seated correctly, and the product is fl owing.
Operation Notes:
The product should be preheated according to the manufacturer’s instructions. The product should be a minimum of 140°F before dispensing.
The thermometer reading will vary with the heating cycle of the dispenser over a range of 20°F. The thermometer should read between 135°F and 180°F during normal dispenser operation. Do not open the door during operation because heat will escape resulting in lower product temperature.
The pump will not function correctly if the product is not at the correct temperature.
The dispenser is designed to operate 24 hours a day. Once the product is placed in the dispenser it should not be removed until the pouch is empty, or the holding period of the product has expired.
NOTE: To increase the evacuation of thicker products, open the dispenser and pull the product towards the outlet fi tment once or twice during operation.If the pump drips
or does not dispense product check to make sure the hose is routed correctly and that the spring is latched onto the catch. Run the dispenser for a short period of time.
CHECKING PRODUCT TEMPERATURE
The machine should be plugged in and turned on with product in the dispenser for a least 5 hours.
1. Dispense at least 3 inches of product into an insulated cup.
2. Without hesitation, insert a thermometer to the bottom of the cup and stir the product gently with the stem of the thermometer.
3. Position the tip of the thermometer in the center of the product mass.
4. The temperature should read between 140°F and 165°F.
4