Star Manufacturing 8C-39D-A Installation Manual

®
JetStar
®
JetStar
®
JetStar
®
COUNTER
JetStar
®
IL1225
POPCORN POPPER
MODEL
39 & 86 Series
Operation
Instructions
2M-Y8397 Rev. O 4/28/11
39 Series
1
2
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
Star reserves the right to change specications and product design without
notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and
regulations, the specications contained in this sheet are subject to change without notice. While Star International Holdings Inc., Company exercises good faith efforts to provide information that is accurate, we are not
responsible for errors or omissions in information provided or conclusions
reached as a result of using the specications. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when
you call to ensure a faster service.
SAFETY SYMBOL
Model No.
Serial No.
Voltage
Purchase Date
Business 8:00 am to 4:30 p.m. Central Standard Time Hours:
Telephone: (314) 678-6303 Fax: (314) 781-2714
E-mail Parts@star-mfg.com
Service@star-mfg.com
Warranty@star-mfg.com
Website: www.star-mfg.com
Service Help Desk
Authorized Service Agent Listing
Reference the listing provided with the unit
or for an updated listing go to:
Website: www.star-mfg.com E-mail Service@star-mfg.com
Mailing Address: Star International Holdings Inc., Company
10 Sunnen Drive St. Louis, MO 63143 U.S.A
2
SPECIFICATIONS
IL1226
DEPTH
WIDTH
HIEGHT
Model
Voltage Amps Watts Width Depth Height Installed Shipped
Electrical
Cord
39 SERIES
8C-39-A-120V 120V 10 1197 NEMA 5-15P 8C-39-A-240V 240V 4.8 1147 NEMA 6-15P
8C-39-A-240VE 230V 4.8 1100 CEE7/VII 8C-39D-A-120V 120V 10 1197 NEMA 5-15P 8C-39D-A-230CE 230V 4.8 1100 CEE7/VII 8C-39D-A-240V 240V 4.8 1147 NEMA 6-15P 8C-39D-A-240VE 230V 4.8 1100 CEE7/VII 8C-39R-A-120V 120V 10 1197 NEMA 5-15P 8C-39R-A-230CE 230V 4.8 1100 CEE7/VII 8C-39S-A-120V 120V 10 1197 NEMA 5-15P 8C-39S-A-240V 240V 4.8 1147 NEMA 6-15P 8C-39S-A-240VE 230V 4.8 1100 CEE7/VII 8C-39S-AS-120V 120V 10 1197 8C-39S-GWP-120V 120V 10 1197
NEMA 5-15P
86 SERIES
8C-86S-120V 8C-86SS-120V 86S-230CE 86SS-230CE
120V 10 1197 NEMA 5-15P
230V 4.8 1100 CEE7/VII
19.5"
49.5 cm
21"
53.3 cm
19.5"
49.5 cm
19.5"
49.5 cm
Size Weight
14.25"
36.2 cm
14.25
36.2 cm
25.125"
63.8 cm
77.5 cm
30.5"
45 lbs
20.41 kg
54 lbs
24.5 kg
56 lbs
25.4 kg
65 lbs
29.5 kg
3
FEATURES
IL1227
BLADE
AGITATOR
MOTOR
AIR INTAKE
CONTROL
SWITCHES
CORN DRAWER
HEAT LAMP
KETTLE
POWER INLET
(Cord not shown)
LOWER DOOR
MAGNETIC
DOOR CATCH
CAUTION
WARNING
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. For equipment to be used by the general public, please contact the factory.
Before using your new equipment, read and understand all the instructions & labels associated with the unit prior to putting it into operation. Make sure all people associated with its use understand the units operation & safety before they use the unit.
All shipping containers should be checked for freight damage both visible and concealed. This unit has been tested and carefully packaged to insure delivery of your unit in perfect condition. If equipment is received in damaged condition, either apparent or concealed, a claim must be made with the delivering carrier.
Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked, a request for inspection of concealed damage must be made with carrier within 15 days. Be certain to retain all contents plus external and internal packaging materials for inspection. The carrier will make an inspection and will supply necessary claim forms.
GENERAL INSTALLATION INSTRUCTIONS
Each machine has been properly wired and inspected at the factory for operation on the voltage and type of
current specied on the nameplate.
DO NOT CONNECT TO ANY OTHER TYPE OF CURRENT OR THE MACHINE WILL BE SERIOUSLY DAMAGED.
120 VOLT MACHINES
Machines with a nameplate stamped 120V are equipped for operation on 120 volt 60 hertz AC single phase service and must be connected to a 3 wire grounded, polarized receptacle.
230 VOLT MACHINES
Machines with a nameplate stamped 230CE are equipped for operation on 230 volt 50 hertz AC single phase service and must be connected to a 3 wire grounded receptacle.
DISPLAY SIGN
The display sign is shipped inside the cabinet. It can be located on the front glass or on the rear doors. If installed on the rear doors, cut the sign after installation to allow the doors to open.
4
CAUTION
CAUTION
GENERAL OPERATING INSTRUCTIONS
The motor air intake hole located on top of the machine must be clear of any obstructions.
DO NOT COVER THIS AIR VENT HOLE AS SERIOUS MOTOR DAMAGE WILL RESULT.
Make sure the corn drawer is in place on the machine before starting the popping cycle. With all switches in the "OFF" (0) position, proceed in the following sequence to pop corn:
1. Turn "ON" (1) the corn warming switch / lamp.
2. Turn "ON" (1) the kettle / motor switch. Allow six or seven minutes to pre-heat the kettle. Thermostat adjustments should not be necessary as it has been preset at the factory for the correct popping temperature.
3. Corn and oil measuring cups are supplied with your machine. Pour a level measuring cup of oil (two ounces) in kettle. Add 6 ounces of raw corn for the 39 Series models or 8 ounces of raw corn for the 86S Series models and 1/2 teaspoon of popcorn salt. Vary the amount of salt and oil to suit taste. If desired, salt may be added after the corn is popped.
4. When the corn stops popping (about 2 1/2 minutes), dump the kettle immediately by turning the handle clockwise approximately 90 degrees to release latch. Recharge as quickly as possible. Screen out unpopped kernels over the perforated section of the corn pan.
5. Turn the kettle switch off (0) when the desired amount of popping is completed.
DO NOT LEAVE THE KETTLE SWITCH "ON" (1) WHEN THE MACHINE IS NOT IN USE. DO NOT IMMERSE KETTLE IN WATER OR ALLOW WATER TO COME IN CONTACT WITH
THE HEATING ELEMENT. POPPING CORN IN DRY KETTLE IS NOT RECOMMENDED.
KEEPING THE POPPING UNIT CLEAN
After each popping period, wipe the inside and outside of the kettle while it is warm (not hot) with a clean cloth. This is important to keep salt, seasoning, oil from forming a carbonized material which not only lowers popping
efciency but can cause excessive smoking or damage the kettle. For retaining the high luster on the stainless
steel kettle shell and lids, use a non-abrasive standard stainless steel cleaner when the kettle is cold. Use a damp cloth and a warm mild soap solution to clean the clear glass and plastic surfaces.
TO REMOVE KETTLE:
Allow kettle to cool or use heat insulated gloves to remove a hot kettle. Turn off the kettle switch. Disconnect the twist lock cap at the end of the kettle conduit, turn kettle handle clockwise 90 degrees to unlatch the kettle. Remove the hitch pin clip from the kettle hinge pin, hold the kettle and pull out the hinge pin. The kettle can now be removed from the unit. Do not place the kettle in water as this will damage the electrical assembly.
MAINTENANCE AND REPAIRS
Contact the factory, a service representative or a local service company for service or required maintenance.
5