Cbmp00l
computerized pool systems
REPLACEMENT TIMER MODULE
(Model MOD-TIMER)
APPLICATION
Compatible with all Compool controllers which utilize an LCD timer.
Replaces circuit boards
PROGRAM SWITCH SEll-INGS
An eight position Program Switch is located on the back-side of the Replacement Timer
Module.
This Program Switch will need to be adjusted before Timer Module is installed.
Use a small blunt instrument (such as the flat-blade screwdriver provided) to slide the
appropriate switch to the ON position.
For detailed explanation of switch functions.
REPLACING BOARD #I0467
When replacing Timer Module
should be programmed ON.
REPLACING BOARD #I0756
When replacing Timer Module
Switch setting on the existing board and adjust the Replacement Timer Module to match
STANDARD PROGRAM SWITCH SETrlNGS
Any of the eight switches may be programmed ON for custom features. See over.
However, Controllers are shipped from the factory in the following condition:
CP-2000 (circuit board
Time Master (circuit board
M-42
(circuit board
M-28
(circuit board
M-28
(circuit board
CP-2020 (circuit board
CP-1000 (circuit board
:
#I0467
#10451):
#lorn):
#10847):
#10528):
#10528B):
#10767):
#10724):
and
#10756.
:
see
over.
:
#I0467
(clear circuit board), switches
#1,
:
#I0756
(blue or green circuit board), check the Program
:
#1,
#2, #3, #4
#1,
#2, #3, #4
#1,
#2, #3, #4
#1,
#2, #3, #4
#1,
#2, #3
#1,
#2, #3
#1
programmed ON.
programmed ON.
programmed ON.
programmed ON.
programmed ON.
programmed ON.
programmed ON.
#2, #3,
and
#4
INSTALLATION OF TIMER MODULE
1.
Turn off all power to the system.
2.
At the Controller, remove mounting screw wh~ch is located to the left and just above
the LCD display.
3.
Carefully slide existing Timer Module out of its socket, and remove.
4.
Before installing new Timer Module, check the Program Switch settings. See above.
5.
Carefully slide new Timer Module into socket on circuit board.
6.
Use mounting screw to secure Timer Module to faceplate.
A new mounting screw is provided if the existing screw has been misplaced.
7.
Just before reconnecting power to the system, carefully remove Battery Shield from
Timer Module in order to activate back-up battery.
8.
Reconnect power to the system.
9.
The Controller is now ready to be programmed as desired.
:
PROGRAM SWITCH FUNCTIONS
#1
Filter Off Delay.
#2
Cleaner On Delay.
#3
Cleaner/Filter Interlock.
#4
Spa/Filter Interlock.
#5
"Once" Program.
#6
Countdown Timer.
#7
Eight Programs.
#8
Program Lock.
:
SWITCH
Filter Pump
heater will also be automatically turned OFF. However, the filter pump will continue to
run for a further four minutes to protect the heater from potential damage.
SWITCH
Pool
cleaner will automatically be delayed for a period of four minutes to protect the pump
from potential damage.
SWITCH
Cleaner/Filter Interlock: Whenever the CLNR Equipment Button is switched ON, the filter
pump will automatically be activated, even if the FILTER Equipment Button has not been
switched ON.
Additional Auxiliary Function: If the control system does not incorporate a pool cleaner,
Switches
additional auxiliary function.
SWITCH
Spa/Filter Interlock: Whenever the SPA Equipment Button is switched ON, the filter
pump will automatically be activated, even if the FILTER Equipment Button has not been
switched ON.
Additionally, if Switch
SWITCH
Single Occurrence Program: This feature is convenient for those who do not use their spa
on a daily basis. It enables the pool owner to enter a "once only" program step which will
occur within the following
equipment sequence.
The "once only" program will automatically be canceled once the C
lock reaches its next program step.
SWCH
Countdown Timer: This feature can be used to preset a
piece of equipment. The cycle is activated whenever that Equipment Button is switched
ON (either in Program Mode or Time Mode.) In Program Mode, it eliminates the program
step normally required to turn that equipment OFF.
Typically used for jet pump, air blower, driveway lights, etc.
SWITCH
Eight Programs: If the standard six programs are insufficient for the Pool Owner's
particular programming requirements, this feature will allow an additional two program
steps to be entered.
#1
(For systems which utilize a filter pump.)
Off
Delay. Whenever the FILTER Equipment Button is switched OFF, the
#2
(For systems which utilize a pool cleaner.)
Cleaner
On
Delay: Whenever the CLNR Equipment Button is switched ON, the pool
#3
(For systems which utilize a pool cleaner.)
#2
and
#3
can be turned OFF, and the CLNR Equipment Button used for an
#4
(For pool/spa combination systems.)
#3
is turned ON, the pool cleaner will automatically be disabled.
#5
(For pool/spa combination systems.)
24
hour period, without having to reprogram the daily
#6
#7
10
minute operating cycle for any
SWITCH
Program
twice in order to put the Clock into Program Mode.
This safeguards against someone inadvertently tampering with the daily program.
#8.
Lock:
With this feature, it is necessary to push the PROGRAM Button quickly