Sta-Rite MiniMax CH Installation Manual

Insulating the High Limits
when
REVERSING HEADS
on the
MINIMAX CH, NT & NT LOW NOx HEATERS
On the MiniMax CH, NT Standard and NT Low NOx heaters there is insulation installed on the return head side of the heaters by the factory. This insulation is there so that if the heads are reversed in the field, during initial installation of the heater, the reflected heat from the flue collector will be insulated from the high limits.
Return head in position before removal. This view shows the insulation installed by the factory.
Return head removed and new tube seals installed. Now ready to accept the installation of the main head.
Lift the installation to allow the main head to be installed. When head is placed into position, release the insulation; it will now shield the high limits from the heat produced by the flue collector.