Star Headlight & Lantern 7100 User Manual

Page 1
Model
7100LED
Ultra-High Intensity Lineum Minibar
If you have any questions concerning this or any other product,
please contact our Customer Service Department at (585) 226-9787.
obtain a Returned Material Authorization number (RMA #) before you ship the product back.
Please write the RMA # clearly on the package near the mailing label.
PLIT508 REV. - 4/28/14
Page 2
IMPORTANT: Please read all of the following instructions before installing your new warning light.
Due to continuous product improvements, we must reserve the right to change any specifications a nd information,
NOTICE
contained in this manual at any time without notice. Star Headlight & Lantern Co., Inc. makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Star Headlight & Lantern Co., Inc. shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this manual.
The manufacturer warrants this LED light against factory defects in material and workmanship for five years after the date of purchase. The owner will be responsible for returning to the Service Center any defective item(s) with the transportation costs prepaid. The manufacturer will, without charge, repair or replace at its option, products, or part(s), which its inspection determines to be defective. Repaired or replacement item(s) will be returned to the purchaser with transportation costs prepaid from the service point. A copy of the purchaser's receipt must be returned with the defective item(s) in order to qualify for the warranty coverage. Exclusions from this warranty include, but are not limited to, domes, and/or the finish. This warranty shall not apply to any light, which has been altered, such that in the manufacturer's judgment, the performance or reliability has been affected, or if any damage has resulted from abnormal use or service.
There are no warranties expressed or implied (including any warranty of merchantability or fitness), which extend this warranty period. The loss of use of the product, loss of time, inconvenience, commercial loss or consequential damages, including costs of any labor, are not covered . The manufacturer reserves the right to change the design of the product without assuming any obligation to modify any product previously manufactured.
This warranty gives you specific l egal rights. You might also have additional rights that may vary from state to state. Some states do not allow limitations on how long an implied warranty lasts. Some states do not allow the exclusion or l imitation of incidental or consequential damages. Therefore, the above limitation(s) or exclusion(s) may not apply to you.
LED FIVE YEAR LIMITED WARRANTY
Mounting
M o un ting Su rfac e
Mount the light through a 11/32” hole using the single bolt on the bottom of the light. Secure it with a flat washer, split washer, and nut.
-1-
Page 3
Wiring for Permanent Mount Models
CAUTION: All of our DC powered warning lights are polarity sensitive. These lights are polarity protected only if the appropriate fuse is used. All wires connected to the positive terminal of the battery should be fused at the battery for their rated load. Testing the
light before this fuse is properly installed will void the warranty on the light.
Red - (Power) Connect to +12 VDC through your switch. Be sure to use a 20
amp fuse when connecting the switch to the positive side of the power
Black - (Ground) Connect to the negative side of the battery.
supply.
Green w/Yellow - (Optional - High/Low) Switches the light between High and Low
power.
High Power Only: Leave disconnected (cover wire with wire nut or tape)
Low Power Only: Connect to Ground
High/Low Switching Option: Connect to Ground through a switch
Red w/Green - (Pattern Select) Touch and release to +12 VDC to change patterns
(see next page).
-2-
Page 4
Pattern Programming
To change patterns, briefly touch and release the Red w/Green Stripe wire to +12 VDC.
The cycle repeats after the last pattern.
Pattern Shortcuts: Touch and hold the Red w/Green Stripe Wire to +12 VDC for the length of
time that corresponds to the pattern you would like to jump to. Once you find the pattern you wish to display, connect the Pattern Select wire to ground and deactivate the light. This will store the selected pattern.
Length of Hold Unit Blinks Jumps to Description
3 sec. 6 sec. 9 sec.
1 time 2 times 3 times
Pattern 5
Pattern 19
N/A
Alt. Tripleflash, Pre-Pop Tripleflash w/Flicker
Alt Long Singleflash (Medium W arn)
Intersection Clearing Light Pattern
Patterns
1. Slow Warn
2. Alt. Doubleflash, Flicker
3. All Double, Alt. Pre-Pop Triple, Slow Warn
4. Alternating Doubleflash, Non-Synch
5. Alt. Triple, Alt. Pre-Pop Triple, Flicker *
6. Alt. Quad, Flicker, Alt. Double, Flicker
7. Alt. Pre-Pop Quint, Alt. Quint, Flicker
8. All Tripleflash
9. Alt. Quadflash w/Post Pop
10. All Quadflash w/Post Pop
11. Alt. Quintflash
12. One Side Steady/Other Side Singleflash †
13. Alt. Pre-Pop Quintflash
14. All Flicker
15. Alt. PSU Flicker
16. One Side Steady/Other Side Short-Long †
17. One Side Rapid Fire, Other Side Pop
18. Comet 1
* =
Default Pattern
=
California Title 13 compliant when properly configured
19. Alt Long Singleflash (Medium Warn)
20. Alt. Short - Alt. Long
21. Slow Warn, Alt. Tripleflash
22. Slow Warn, Super Fast Warn
23. All Doubleflash, Alt. Doubleflash
24. All Double, Alt. Double, Flicker
25. Fast Warn
26. Superfast Warn
27. Warn Fade
28. Pre-Pop Warn
29. All Singleflash
30. Alt. Tripleflash
31. All Quintflash
32. One Side Pop, Other Side Rapid Fire
33. Comet 2
34. Delta Omega
35. Cycle All Patterns
Please Note: These instructions are provided as a general guideline only. Specific mounting, wiring, and/or weather-sealing may be necessary and are the sole responsibility of the installer. Star Headlight & Lantern Co., Inc. assumes no responsibility for the integrity of the installation for this or any of its products.