Staray A-250RGP User Manual

Laser Show System
- 1 -
1. General instructions
Thank you for purchasing this product. Please read user guide for safety and operations information before using the
product for better use and safety operation. Keep this manual for future reference. This product can create perfect laser
programs and effects since it has passed a series of strictly tests before delivery.
Please handle with care after recei ving the unit and check the attach ments listed on the page after o pening the carton. In
department.
Attachments:
1. Laser Light 1PCS 2. Power Cable 1PCS 3. User Guide 1PCS
2. Notice:
1. Do not exposure the human eye direct to laser beam.
2. Do not turn on and off the unit frequently.
3. Before using this unit makes sure the power supply is ground.
4. This unit is intended for indoor use only and should be prevented form water, moisture and shake. The working
temperature of this unit is 1830, do not use this continuously over 4 hours, otherwise it shortens the lifetime of the
unit.
5. Use cleaning tissue to remove the dust absorbed on the external lenses periodically to optimize light output.
6. Do not remove or break the warranty label, otherwise it void the warranty.
7. Always replace with the exact same t ype fuse, replacement with anything other than the specified fuse can cause fire
or electric shock and damage your unit, and will void your manufactures warranty.
This product installation operation and maintenance should be by professional.
Warn ing Do not exposure the human eye direct to laser beam.
3. Installation
1. Before installation, please make sure power voltage is proper as the one marked on the unit.
2. This product should be installed by professional to make sure it is fixed safely and have adjusted suitable shining
angel.
3. When installing this unit, pleas e make sure there is nothing flammab le or explosive 0.5 meter near th e unit. Make
sure there is 15 mm distance between t he unit and the wall. Please make su re to use safety rope which can supp ort
tenfold weight of the unit to assist fitting.
Laser Show System
- 2 -
4. Front Panel
NPL-1892 GREEN
POWER
MUSIC
MICRO
exposure to direct or scattered radiation.
Visible or invisible radiation,avoid eye
1. Laser Aperture 2. Sound Active Microphone
3. Sound Active Indicator 4. Power Indicator
Rear Panel
4 5 6
9
7
8
SL-3438
100V-240V/AC/2A 50-60Hz
MIN
MAX
FUNCTI0N SETTING
0N
OFF
POWER SWITCH
SERIAL No.
ILDA
PATTERN SIZE
ILDA INTERFACE
MIN
MAX
12345678910
DMX
IN
OUT
MIN
ILDA INTERFACE
ILDA
POWER SWITCH
OFF
0N
1
2
3
1 Address Code On/ Off 2 DMX Connector 3 Sound Active Knob
4 Fan 5 Pattern Knob 6 Switch
7 ILDA Connector 8 Power supply 9 Fuse
5. Function Setting
Dipswitches #10 are use to set 4 working modes as Sound active, Automatic, Slave/Master and DMX mode.
DMX MODE have DMX control channel address for setting, Namely DMX Address, see the function setting chart.
When dipswitch 10# selected ON, Function of #1#9 as below: 0OFF 1=ON X=OFF or ON
Laser Show System
- 3 -
DIPSWITCH CHART
FUNCTION
#1 #2 #3 #4 #5 #6 #7 #8 #9 #10
0 0 0 X X X X X X 0 SOUND ACTIVE
1 0 0 X X X X X X 0 AUTO-BEAM
1 1 0 X X X X X X 0 AUTO-ANIMATION
0 0 1 X X X X X X 0 SLAVE MODE
SET DMX ADDRESS 1 DMX MODE
6. Stand-Alone Operation (Sound Active, AUTO mode)
1. Set dipswitch to select Sound Active or AUTO mode.
2. The unit will react to the low frequencies of music via the internal microphone. Adjust the audio sensitivity knob on
the back of the unit to make the unit more or less sensitive in sound active.
7. Master-Slave Operation
1. Choose a unit to function as Master mode, set dipswitch to select Sound Active or AUTO mode. The others must be
set to Slave mode, set dipswitch to select Slave mode.
2. Use standard XLR microphone cable chain your units together via the XLR connector on the rear of the units. For
longer cable runs we suggest a terminator at the last fixture.
3. Turn on the all units' power, the units begins reset, and then the unit begins working. The slave units will action the
same as the master unit.
Master/Slave mode no need DMX controlled, There should be only one master unit in Master-Slave operation. For
working time of slave and the master unit should at the same time, we suggest Master and Slave unit run from one power
switch.
8. Master-Slave Connection
120
PIN2
PIN3
MASTER
SLAVE SLAVE
PATTERN SIZE
MIN
MAX
ILDA INTERFACE
SERIAL No.
FUNCTI0N SETTING
MAX
MIN
OUT
IN
DMX
100V-240V/AC/2A 50-60Hz
10987654321
0N
OFF
POWER SWITCH
PATTERN SIZE
MIN
MAX
ILDA INTERFACE
SERIAL No.
FUNCTI0N SETTING
MAX
MIN
OUT
IN
DMX
100V-240V/AC/2A 50-60Hz
10987654321
0N
OFF
POWER SWITCH
PATTERN SIZE
MIN
MAX
ILDA INTERFACE
SERIAL No.
FUNCTI0N SETTING
MAX
MIN
OUT
IN
DMX
100V-240V/AC/2A 50-60Hz
10987654321
0N
OFF
POWER SWITCH
9. DMX Control Connection
The System only accepts the DMX512 signal of international standard to control the system mode, the laser beam
ON/OFF, running direction, running speed and twinkle speed etc.
Laser Show System
- 4 -
DMX SIGNAL
120
PIN2
PIN3
PATTERN SIZE
MIN
MAX
ILDA INTERFACE
SERIAL No.
FUNCTI0N SETTING
MAX
MIN
OUT
IN
DMX
100V-240V/AC/2A 50-60Hz
10987654321
0N
OFF
POWER SWITCH
PATTERN SIZE
MIN
MAX
ILDA INTERFACE
SERIAL No.
FUNCTI0N SETTING
MAX
MIN
OUT
IN
DMX
100V-240V/AC/2A 50-60Hz
10987654321
0N
OFF
POWER SWITCH
PATTERN SIZE
MIN
MAX
ILDA INTERFACE
SERIAL No.
FUNCTI0N SETTING
MAX
MIN
OUT
IN
DMX
100V-240V/AC/2A 50-60Hz
10987654321
0N
OFF
POWER SWITCH
10. DMX Control Setting
Channel 512 Value Description
1 Mode
049 Sound active mode
5099 AutoBeam mode
100149 AutoAnimation mode
150199 DMX modeSound active touch off
200255 DMX modeAuto touch off
2
Flickering &
Shut off
0255 shut off –no flickering-mullah flickering -frequently flickering-fastness flickering
3 Pattern change 0~255 128/256 patternstwo/one number allot one pattern
4
Vertical
Moving
0127 Hand control vertical moving
128191 Auto adown moving. moving speed is positive pro rata to handspike value
192255 Auto up moving. moving speed is positive pro rata to handspike value
5
Horizontal
Moving
0127 Hand control horizontal moving
128191
Auto moving towards right hand side. moving speed is positive pro rata to handspike
value
6
Vertically
Overturn
0127 Hand operated vertically reversal
128~255 Automatic vertically reversal. reversal speed is positive pro rata to handspike value
7
Horizontal
overturn
0127 Hand operated horizontal reversal
128255 Automatic horizonta l reversal. reversal speed is positive pro rata to handspike value
8 Rotation
0127 Hand operated rotation
128191 Auto clockwise rotat ed. rotation speed is positive pro rata to handspike value
192255
Automatic counterclockwise rotated. rotation speed is positive pro rata to handspike
value
9 Scale 085 Scale from small to large, scale speed is positive pro rata to handspike value
Laser Show System
- 5 -
11. Technical Parameter
Item
Spec
A-250RGP
Laser Light Red; Green;
Laser Power Red: 100mW /650n m; Green 30mWPurple 100mw
Dimension 212*257*110mm
Net Weight 2.0kg
Scan System
High speed XY Scanner Module (scan speed>15kpps; scan angle±30°; input signal ±5v; linearity
distortion<2%)
System Port DMX512 input and output port, ILDA DB standard port
Control Mode Sound Active, Automatic, DMX512(12 channels), Master/Slave, PC Control
Demo Effect
Blanking, rotating, zoom, retro flexion, moving, strobe, 3D etc, used for words, Cartoon, and beam show
and laser advertisement.
Work Environment 10-35°C Indoor
Power Supply AC100/240V 50-60Hz 100W
Work Place Disco, KTV, Bars, Clubs, Family party, Opera House Advertisement etc.
12. Troubleshooting
1. In Stand-Alone operation, if the power supply indicator is light up and sound active indicator isn't light up, but the
laser is shut off doesn't work, Please check i f unit has been set up in slave mode, then set up in master mode.
2. In Master-Slave operation, slave unit don't function, please check as below.
A. Make sure to there's only one master in t he chain, and the others are set in slave mode.
B. Make sure to control the unit without DMX console controlling.
C. Make sure to take a good quality power cable and connection.
3. In DMX mode operation, the laser is OFF and the DMX signal indicator is unlighted , please check as below
86170 Scan from large to small, scale speed is positive pro rata to handspike value
171255 Alternate scale, scale s peed is positive pro rata to handspike value
10 Size 0~255 0 original,1min,255max
11 Brightness 0~255 0 no brightness ,1min,255max
12 Draw gradually
0127 Auto Draw gradually 1, draw gradually speed is positive pro rata to handspike value
127255 Auto Draw graduall y 2, draw gradually speed is positive pro rata to handspike value
Laser Show System
- 6 -
Make sure to set up the DMX mode, make sure to have a good connection.
4. In DMX operation, the unit can’t be controlled by the DMX console, but the DMX signal indicator is flashing, please
make sure the DMX console and unit have the same channel.
5. If the unit is fail, please turn off the unit, and then turn on again after 5 minutes.
After trying the above solution you still have a problem, please contact your dealer or our company for service.
Trouble manifestation Trouble shooting
If the power supply indicator doesn’t light up and laser
doesn’t work
Please check the power supply and the input voltage
If the sound active indicator isn’t light up with music
active
Please increase the music volume or audio sensitivity with sensitivity knob
In Automatic mode operation, if power supply indicator
is light up, but laser light is not light up
Please check if any trouble with laser machinery
If the laser beam is at rest in working mode Product problem
After trying the above solution you still have a problem, please contact your dealer or our company for service
Loading...