RCR-4
SAFETY SYMBOL
Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and
without notice. While Star International Holdings Inc., Company exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions
These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE
provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to ensure a faster service.
Authorized Service Agent Listing
Model No.
Serial No.
Voltage
Purchase Date
Reference the listing provided with the unit
or
for an updated listing go to:
Website: www.star-mfg.com E-mail customerservice@star-mfg.com
Service Help Desk
Business 8:00 am to 4:30 p.m. Central Standard Time Hours:
Telephone: (800) 264-7827
Fax: (314) 781-2714
E-mail customerservice@star-mfg.com
Website: www.star-mfg.com
Mailing Address: Star Manufacturing International Inc.
265 Hobson Street Smithville, TN 37166 U.S.A
ELECTRICAL SPECIFICATIONS
Model No Voltage Watts HP Amps Ph Power Supply Refrigerant
RCR-4 120V 240 1/6 2 1 NEMA 5-15P 134A
GENERAL INSTALLATION INSTRUCTIONS
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations.
Before using your new equipment, read and understand all the instructions & labels associated with the unit prior to putting it into operation. Make sure all people associated with its use understand the units operation & safety before they use the unit.
All shipping containers should be checked for freight damage both visible and concealed. This unit has been tested and carefully packaged to insure delivery of your unit in perfect condition. If equipment is received in damaged condition, either apparent or concealed, a claim must be made with the delivering carrier.
Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked, a request for inspection of concealed damage must be made with carrier within 15 days. Be certain to retain all contents plus external and internal packaging materials for inspection. The carrier will make an inspection and will supply necessary claim forms.
Any procedure which requires the use of tools must be performed by a qualied technician.
These refrigerated condiment rails are equipped for the voltage and wattage indicated on the nameplate. These units are designed to operate on alternating current (AC) only. DO NOT CONNECT TO DIRECT
CURRENT (DC).
AGENCY LISTING INFORMATION
This appliance is U Listed under UL File SA12649 for 120VAC 60Hz only.
All servicing requiring access to non-insulated electrical components must be performed by a factory authorized technician.
WARNING
DO NOT open any access panel which requires the use of tools. Failure to follow this warning can result in severe electrical shock.
p/n 2M-Z19984 Owners Manual Refrigerated Condiment Rail, RCR-4
1
FEATURES & BENIFITS
NAMEPLATE
(4) 1/6 PANS (INCLUDED)
S/S PAN DIVIDER
(INCLUDED)
ON/OFF SWITCH
REAR VIEW
15.125”
1/6 1/6
1/61/6
12” OPN'G
TOP VIEW
POWER
CORD
25.5”
CLEARANCE
1” SIDE & REAR
OPTIONAL S/S NIGHT COVER
10.5
2/3
FRONT VIEW
1/3
1/3
1/6 1/6
1/3
1/6 1/6
1/9 1/9 1/9
SIDE VIEW
1/9 1/9 1/9
1/9 1/9 1/9
VARIOUS OTHER PAN ARRANGEMENTS
(PANS BY OTHERS)
2
IL2877
p/n 2M-Z19984 Owners Manual Refrigerated Condiment Rail, RCR-4
INSTALLATION
UNPACKING & INSPECTION
Carefully remove the appliance from the carton. Remove all protective plastic lm, packing materials and
accessories from the Appliance before connecting electrical power or otherwise performing any installation procedure.
Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the appliance before starting any installation.
Read and understand all labels and diagrams attached to the appliance.
Carefully account for all components and accessories before discarding packing materials. Store all accessories in a convenient place for later use.
IMPORTANT
This unit should NEVER be positioned upside down or on its side. If the unit arrived or was stored in any position other that “THIS END UP” as marked on the shipping container, then allow the unit to set upright 24 hours before applying power or turning on the unit. Failure to do this will cause the unit to function incorrectly. The unit will not be able to cool to the desired temperature.
COMPONENTS
4 ea 1/6 PANS
SET-UP NOTES
1. Setup the appliance only on a rm, level, non-combustible surface. Verify local codes for requirements.
Concrete, tile, terrazzo or metal surfaces are recommended. Metal over combustible material may not meet code for non-combustible surfaces.
2. The adjustable legs come installed from the factory, with a spirit level, check that the appliance is level
front-to-back and side-to-side. Verify that the unit sits rmly ON ALL FOUR LEGS.
3. The lower portions of the legs are adjustable by turning; adjust as required to level the appliance. All
four legs must be adjusted to rmly contact the counter.
4. Avoid storing ammable or combustible materials in, on or near the appliance.
ELECTRICAL HOOK-UP
1. Refer to the nameplate. Verify the electrical service power. Voltage and phase must match the
nameplate specications. Plugging the warmer into the wrong voltage can severely damage the unit or
cause noticeable decreased performance.
2. Your unit is equipped with a grounded electrical cord. This cord must be plugging into a properly grounded electrical receptacle.
Installation procedures must be performed by a qualied technician with
full knowledge of all applicable electrical and plumbing codes. Failure
WARNING
IMPORTANT:
This appliance must be plugged into a properly grounded receptacle. Contact a licensed electrician to install and connect a proper receptacle.
IMPORTANT:
Damage due to being connected to the wrong voltage or phase is NOT covered by warranty.
p/n 2M-Z19984 Owners Manual Refrigerated Condiment Rail, RCR-4
can result in personal injury and property damage.
3
OPERATION
SUGGESTIONS: Inspect each pan insert for thorough cleaning. Additional hand cleaning may be necessary
to insure complete food removal.
If detergent is used, items must be rinsed with clean water prior to use.
PRE-CHILLING THE SERVER
1. Turn power switch on.
2. Place desired pan(s) or inset(s) with appropriate adapter top on server.
3. Allow unit to run for approximately 30 minutes
OPERATION
1. Always use an inset. DO NOT place food directly into the server.
2. DO NOT use metal tools, steel wool, or caustic or abrasive cleanser to any metal surface on the unit.
IMPORTANT:
DO NOT put water or ice in the well of the server.
CLEANING INSTRUCTIONS
PREPARATION Turn power switch OFF
Unplug from electrical power
Remove Removable Pans
FREQUENCY Daily, or as needed
TOOLS Bottle Brush, Soft Bristle Brush
Soft Cloth or Sponge
CLEANING
1. Turn power switch OFF and unplug unit.
2. Remove (optional) cover., clean using warm water and mild detergent.
3. Remove pans and pan support, clean using warm water and mild detergent.
4. Clean the stainless steel using mild detergent, warm water and soft cloth or sponge. Dry using a
clean cloth. DO NOT use any abrasive pads or wire brushes.
Procedure is complete.
Turn power switch OFF and disconnect unit from electric power before cleaning.
WARNING
IMPORTANT:
NEVER use any corrosive cleaners, use only cleaners approved for stainless steel.
p/n 2M-Z19984 Owners Manual Refrigerated Condiment Rail, RCR-4
4
TEMPERATURE ADJUSTMENT
TEMPERATURE ADJUSTMENT
RCR-4
1. The temperature has been preset at the factory to meet most applications.
2. If temperature adjustments are required, the pressure switch, located on the condensing unit, is adjustable. Temperature adjustment must be
performed by a qualied refrigeration
personnel only.
3. Normal temperature setting would be 28ºF.
The LCD Display provides a readout of the sensor temperature during normal operation. Use the following to change the set-point temperature:
1. To start programming, press SET key once. This will access the Fahrenheit/ Celsius mode. The readout will show the current status, either F (degrees Fahrenheit) or C (degrees Celsius). Press either “up arrow” (é) or “down arrow” (ê) to toggle between F and C designation.
LCD READOUT
“SET” KEY
” KEY (INCREASE)
” KEY (DECREASE)
IL2878
2. Press SET again to access the set-point. The LCD will display the current set-point, and the S1 annunciator will blink off and on to indicate that control is in the set-point mode.
Press either “up arrow” (é) to increase the set-point, or “down arrow” (ê) to decrease the set-
point to the desired temperature. Factory set-point is 21ºF.
IMPORTANT:
DO NOT adjust the differential settings of the refrigeration system. Field adjustments of the differential settings must be made by qualied refrigeration personnel only. Unauthorized adjustment of the differential settings
will void the warranty.
The temperature setting of the NSF-7 Refrigerated Cold Pan has been pre-set at the factory to meet most applications. An electronic temperature control maintains food temperature between 33ºF and 44ºF.
3. Press the SET key again to access the differential. The LCD will display the current differential, and the DIF1 annunciator will blink off and on to indicate that control is in the differential mode.
IMPORTANT: DO NOT adjust the differential settings of the refrigeration system. Field
adjustments of the differential settings must be made by qualied refrigeration personnel only.
Unauthorized adjustment of the differential settings will void the warranty.
Press either “up arrow” (é) to increase the differential, or “down arrow” (ê) to decrease the
differential to the desired setting. Factory differential is 3ºF.
4. Press the SET key again to access the Heating / Cooling mode. The LCD will display the current mode. Either “C1” for cooling or “H1” for heating. The control must be set to C1 for proper
p/n 2M-Z19984 Owners Manual Refrigerated Condiment Rail, RCR-4
operation of the cold pan.
5. Press the SET key again to complete programming. Programming ends automatically if no keys are pressed for 30 seconds. Any settings that have been input to the control will be accepted at that time.
5
TEMPERATURE ADJUSTMENT continued
6. Control settings are stored in non-volatile memory. Loss of power to the unit will not require reprogramming.
IMPORTANT:
DO NOT adjust the differential settings of the refrigeration system. Field adjustments of the differential settings must be made by qualied refrigeration personnel only. Unauthorized adjustment of the differential settings
will void the warranty.
NOTE:
The controller has both “heating” and “cooling” modes. Heating mode is not used on the RCTS-series units. The control must be set to “cooling” (C1) for proper operation of the cold pan.
TROUBLESHOOTING
SYMPTOM PROBABLE CAUSE SUGGESTED REMEDY
No power to unit Unit unplugged or circuit breaker tripped
Power switch off Turn switch ON
Unit will not run
Damaged power cord Replace power cord
Damaged power switch Replace switch
Damaged motor Replace motor
Plug unit into appropriate receptacle
Reset circuit breaker
p/n 2M-Z19984 Owners Manual Refrigerated Condiment Rail, RCR-4
6
RCTS WIRING DIAGRAM
WIRING DIAGRAM
COMPRESSOR FAN
ELECTRONIC
TEMPERATURE
p/n 2M-Z19984 Owners Manual Refrigerated Condiment Rail, RCR-4
CONTROL
SWITCH
POWER
SUPPLY CORD
7
SK2882, Rev. -, 2/12/15
Model: RCR-4
Refrigeration Countertop Server
10
18
12
8
1
3
1
2
11
9
14
7
8
4
17
19
13
5
6
15
21
22
20
8
p/n 2M-Z19984 Owners Manual Refrigerated Condiment Rail, RCR-4
PARTS LIST February 12, 2015, Rev. -
Model: RCR-4, REFRIGERATED COUNTER TOP SERVER
Fig. No. Part No. Qty Description
1 1 TOP
2 1 PAN
3 1 SIDE PANEL, LEFT
4 1 SIDE PANEL, RIGHT
5 1 BOTTOM PANEL
6 1 BOTTOM PANEL ANGLE
7 1 ENCLOSURE PANEL
8 1 LOUVERED PANEL
9 1 LOUVERED PANEL
10 1 NIGHT COVER
11 2V-Z19295 1 DIVIDER BAR
12 2L-Z19296 4 PAN, 6”D X 6.9375” L X 6.375” W
13 2U-Z19297 1 COMPRESSOR
14 3E-Z17505 1 TEMP CONTROL
15 2E-Z3808 1 SWITCH, ROCKER ON-ON
16 2R-Z19299 4 FOOT, ADJUSTABLE
17 2E-Z19300 1 4FT CORD w/NEMA 5-15P PLUG
18 1 HANDLE
19 1 STRAIN RELIEF
20 2U-Z19301 1 FAN
21 1 CONDENSER COIL
22 2R-Z19302 1 FAN GRILL
23 2M-Z19987 1 RCR OVERLAY
p/n 2M-Z19984 Owners Manual Refrigerated Condiment Rail, RCR-4
9
STAR MANUFACTURING INTERNATIONAL INC.
Star - Holman - Lang - Wells - Toastmaster
265 HOBSON ST. SMITHVILLE, TN 37166
(800) 264-7827
www.star-mfg.com